• Title/Summary/Keyword: Alarm sound

Search Result 66, Processing Time 0.023 seconds

An Predictive System for urban gas leakage based on Deep Learning (딥러닝 기반 도시가스 누출량 예측 모니터링 시스템)

  • Ahn, Jeong-mi;Kim, Gyeong-Yeong;Kim, Dong-Ju
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.41-44
    • /
    • 2021
  • In this paper, we propose a monitoring system that can monitor gas leakage concentrations in real time and forecast the amount of gas leaked after one minute. When gas leaks happen, they typically lead to accidents such as poisoning, explosion, and fire, so a monitoring system is needed to reduce such occurrences. Previous research has mainly been focused on analyzing explosion characteristics based on gas types, or on warning systems that sound an alarm when a gas leak occurs in industrial areas. However, there are no studies on creating systems that utilize specific gas explosion characteristic analysis or empirical urban gas data. This research establishes a deep learning model that predicts the gas explosion risk level over time, based on the gas data collected in real time. In order to determine the relative risk level of a gas leak, the gas risk level was divided into five levels based on the lower explosion limit. The monitoring platform displays the current risk level, the predicted risk level, and the amount of gas leaked. It is expected that the development of this system will become a starting point for a monitoring system that can be deployed in urban areas.

  • PDF

Comparision Between Noise Levels of Hospital Wards and the Nurses Efforts for Noise Management in Selected General Hospital (종합병원 병동별 간호사실의 소음정도와 간호사실들의 소음인지도 및 소음관리노력 비교)

  • Jung, Hyun-Wook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.174-182
    • /
    • 2001
  • This study was performed to find out the differences between noise levels of hospital wards and the nurses efforts for noise management in some general hospitals. The hospital wards selected were the intensive care unit(ICU), the emergency room(ER), the nursery room(NR), the internal medicine(IM), the general surgery(GS) among the 5 general hospitals located in Seoul. The data were collected from August 3 to September 13, 1999 through questionnaire survey and noise measurement in each nursing station of hospital wards. Data analysis was done by SPSS 8.0 package among the 305 questionnaires and 24 hours monitored noise levels. Frequency, Chi-square and ANOVA test were used. The study results were as belows: 1. The noise level measured by 24 hours monitoring survey were exceeded on the standard limit in all the hospital wards. Data also showed that noise levels were significantly different in each ward among the three shifts working duties. 2. The subjects were all female nurses. They were mostly working in the ICU ward(28.9%). They were 26~30 years old (43.9%), junior college graduates(57.0%), working for 1~5 years(55.1%) as staff-nurse(85.6%). There were no significant differences between hospital wards and general characteristics of nurses. 3. The noise levels perceived by nurses were regarded as 'Highly noisy'(56.4%), especially during the 11:30 and 15:30 (30.2%) o'clock. Data also showed that noise education was not ever given to nurses(89.9%). Nurses also responded that they hardly put an effort to reduce noise level(54.8%). However, there were significant differences between wards and noisy working time, experience of noise education and level of effort for noise reduction. 4. Nurses also perceived the ventilator alarm and EKG-alarm as the most disturbing sounds in the ICU, human voice and telephone ringing in the ER, human voice and EKG-alarming in the NR, human voices and telephone ringing in IM and GS both wards respectively in order. There were significant differences between hospital wards and noise making factors. 5. Nurses were shown that they regarded highly 'Sound reduction of the human voice', 'Careful handling on medical instruments', and 'Immediate appliances on alarming materials' as the practical method for noise management. There were significant differences between hospital wards and behavioral practical efforts for noise management. According to that results, the statistical differences were shown in the 24 hour monitored noise levels in each ward. Also, nurses perceived the noise severity differently and they approached variously on the practical efforts for noise reduction in each ward. Thus, author thinks that concrete and systematic endeavor will be necessary for noise reduction and management in hospitals for better working and healing environment for both of patients and staffs.

  • PDF

Development of Hardware for the Architecture of A Remote Vital Sign Monitor (무선 체온 모니터기 아키텍처 하드웨어 개발)

  • Jang, Dong-Wook;Jang, Sung-Whan;Jeong, Byoung-Jo;Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2549-2558
    • /
    • 2010
  • A Remote Vital Sign Monitor is an in-home healthcare system designed to wirelessly monitor core-body temperature. The Remote Vital Sign Monitor provides accuracy and features which are comparable to hospital equipment while minimizing cost with ease-of-use. It has two parts, a bandage and a monitor. The bandage and the monitor both use the Chipcon2430(CC2430) which contains an integrated 2.4GHz Direct Sequence Spread Spectrum radio. The CC2430 allows Remote Vital Sign Monitor to operate at over a 100-foot indoor radius. A simple user interface allows the user to set an upper temperature and a lower temperature that is monitored with respect to the core-body temperature. If the core-body temperature exceeds the one of two defined temperatures, the alarm will sound. The alarm is powered by a low-voltage audio amplifier circuit which is connected to a speaker. In order to accurately calculate the core-body temperature, the Remote Vital Sign Monitor must utilize an accurate temperature sensing device. The thermistor selected from GE Sensing satisfies the need for a sensitive and accurate temperature reading. The LCD monitor has a screen size that measures 64.5mm long by 16.4mm wide and also contains back light, and this should allow the user to clearly view the monitor from at least 3 feet away in both light and dark situations.

Analysis of Ambivalence Differences among Groups for Temporary Firefighting Facilities of Workers at Construction Sites (공사현장 근로자의 임시소방시설에 대한 집단 간 Ambivalence 차이분석)

  • Moon, Pil-Jae;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.765-778
    • /
    • 2021
  • The purpose of this study is to prevent fire accidents in advance by deriving prior knowledge among groups about temporary fire-fighting facilities of workers at construction sites and devising appropriate improvement measures. The findings are as follows.First, in the case of fire extinguishers, statistical attention was paid to the contractor, supervisor, partner worker and fire extinguisher manager between designations. 87% of fire managers and 70% of facility supervisors said fire extinguisher management managers needed to be designated for each type of construction, which requires designation of fire extinguisher management managers, frequently checking and relocating. Second, in the case of simple fire extinguishing facilities, statistical attention was paid to the application of penalties for unauthorized use of fire extinguishing facilities with construction companies, supervisors, and business partners.Third, in the case of emergency alarm measures, statistical attention was paid to the application of emergency alarm sound to temporary broadcasting facilities with construction works, supervisors, and business partners.Fourth, in the case of induction, statistical attention was paid to the application of connection between construction works, supervisors, and partner workers, such as passage guidance, emergency lighting, etc.It was found that 65% of construction workers and 55% of electrical workers had different applications such as aisle guidance and emergency lighting for each type of business partner. In order to resolve blind spots such as evacuation zone guidance due to the structure of the building, it is necessary to easily distinguish the direction of the entrance door from a long distance by applying it in conjunction with passage guidance lights and emergency lighting.

Improving target recognition of active sonar multi-layer processor through deep learning of a small amounts of imbalanced data (소수 불균형 데이터의 심층학습을 통한 능동소나 다층처리기의 표적 인식성 개선)

  • Young-Woo Ryu;Jeong-Goo Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.2
    • /
    • pp.225-233
    • /
    • 2024
  • Active sonar transmits sound waves to detect covertly maneuvering underwater objects and detects the signals reflected back from the target. However, in addition to the target's echo, the active sonar's received signal is mixed with seafloor, sea surface reverberation, biological noise, and other noise, making target recognition difficult. Conventional techniques for detecting signals above a threshold not only cause false detections or miss targets depending on the set threshold, but also have the problem of having to set an appropriate threshold for various underwater environments. To overcome this, research has been conducted on automatic calculation of threshold values through techniques such as Constant False Alarm Rate (CFAR) and application of advanced tracking filters and association techniques, but there are limitations in environments where a significant number of detections occur. As deep learning technology has recently developed, efforts have been made to apply it in the field of underwater target detection, but it is very difficult to acquire active sonar data for discriminator learning, so not only is the data rare, but there are only a very small number of targets and a relatively large number of non-targets. There are difficulties due to the imbalance of data. In this paper, the image of the energy distribution of the detection signal is used, and a classifier is learned in a way that takes into account the imbalance of the data to distinguish between targets and non-targets and added to the existing technique. Through the proposed technique, target misclassification was minimized and non-targets were eliminated, making target recognition easier for active sonar operators. And the effectiveness of the proposed technique was verified through sea experiment data obtained in the East Sea.

A Needs Assessment of People with Hearing Impairment for Hearing Augmentation Technology Development: Focusing on Risk Context Awareness Communication (청각증강 기술 개발을 위한 청각장애인의 욕구조사: 위험상황 인식 및 의사소통 분야를 중심으로)

  • Lee, Jun Woo;Lee, Hyuna;Bach, Jong Mie
    • 재활복지
    • /
    • v.22 no.3
    • /
    • pp.225-257
    • /
    • 2018
  • The purpose of this study is to find the application point of hearing augmentation technology development through examining the risk context experience of people with hearing impairment and the use of assistive device used as an alternative technology. Data of 355 people with hearing impairment with official disability grading was analyzed. The results of this study are first, research participants had no experience of recognizing any sound or vibration in situations highest in the order of means of transportation, material, and nature. Especially the ratio of being unable to recognize the sound and vibration of means of transportation was high, which implies the high possibility of people with hearing impairment experiencing risk. Secondly, the risk context that people with hearing impairment will most likely to experience are highest in the order of traffic accident, pedestrian accident, and daily life at home. Thirdly, the recognition of 2G phone/smart phone, vibrating digital alarm clock, light bar, vibrating wrist watch as assistive device for risk context awareness and notification was high and the satisfaction level of 2G phone/smart phone was the highest. Fourthly, the research participants had high recognition of assistive device for communication in the order of hearing aid, smart phone, videophone, cochlear implant and 2G phone and it was found that the satisfaction level and communication improvement level was the highest using the smart phone. Lastly, for the development of hearing augmentation technology the research participants recognized the importance of portable/wear convenience, price, and motion accuracy and for notification delivery means they preferred the method of using sight(text and light). Based on the results of this study policy and practical plans for hearing augmentation technology development for people with hearing impairment in risk context are proposed.

Design of Parallel Processing of Lane Detection System Based on Multi-core Processor (멀티코어를 이용한 차선 검출 병렬화 시스템 설계)

  • Lee, Hyo-Chan;Moon, Dai-Tchul;Park, In-hag;Heo, Kang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.9
    • /
    • pp.1778-1784
    • /
    • 2016
  • we improved the performance by parallelizing lane detection algorithms. Lane detection, as a intellectual assisting system, helps drivers make an alarm sound or revise the handle in response of lane departure. Four kinds of algorithms are implemented in order as following, Gaussian filtering algorithm so as to remove the interferences, gray conversion algorithm to simplify images, sobel edge detection algorithm to find out the regions of lanes, and hough transform algorithm to detect straight lines. Among parallelized methods, the data level parallelism algorithm is easy to design, yet still problem with the bottleneck. The high-speed data level parallelism is suggested to reduce this bottleneck, which resulted in noticeable performance improvement. In the result of applying actual road video of black-box on our parallel algorithm, the measurement, in the case of single-core, is approximately 30 Frames/sec. Furthermore, in the case of octa-core parallelism, the data level performance is approximately 100 Frames/sec and the highest performance comes close to 150 Frames/sec.

Mobile Guidance System for Evacuation based on Wi-Fi System and Node Architecture

  • Raju, Timalsina;Kim, Woo Sung
    • Journal of Information Technology Applications and Management
    • /
    • v.26 no.5
    • /
    • pp.41-56
    • /
    • 2019
  • Recently great loss of life and property is occurring because of fire, natural disaster, earth quake, tsunami and so on. People spend 80~90% of their time indoor environment like office, supermarket, campus. Therefore Indoor navigation and guidelines system became so essential for most of all. Incase of emergency we must be careful earlier, in such a cases 5G kind of new technology may also cannot work. So immediate action and quick routing notification for guidelines and protection is the most. Considering this issue We proposed indoor evacuating guidance system based on microcontroller Wi-Fi board for Indoor APP using mobile. Focusing various kind of technology like, ok google, voice search APP we purposed node architecture based system. When we listen fire alarm while living inside the room. Then to be safe we connect with server and start Arduino UNO+IoT ESP8266 Wi-Fi shield version1-IoT module to store data in MySQL DB server. We make application to escape out from the building up-to the three exits giving information from source point to destination. Our program can send information to the users emergency location and situations. For this when the user get sound or vibration in their mobile device it indicate fire out near by. At that time we update message from Arduino to DB server for the fixed current position inside the building which give routing signal for that fire out location by changing values from 0 to 1. We have user in point 10 where user is near by. Later we detect Wi-Fi signal form Nodemcu as room of each floor and try to connect with user. Main purpose of this paper is to save life of people in short time and find out the shortest path up to nearest exits in the time of emergencies and rescue them.

Implimentation of Smart Farm System Using the Used Smart Phone (중고 스마트폰을 활용한 스마트 팜 시스템의 구현)

  • Kwon, Sung-Gab;Kang, Shin-Chul;Tack, Han-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.11
    • /
    • pp.1524-1530
    • /
    • 2018
  • In this paper, we designed a product that can prevent environmental pollution, waste of resources, and leakage of foreign currency by commercializing a green IT solution by merging a used smart phone with the IoT object communication technology for the first time in the world. For the experiment of the designed system, various performance and communication condition was experimented by installing it in the actual crop cultivation facility. As a result, when a problem occurs, the alarm sound and video notification are generated by the user's smart phone, and remote control of various installed devices and data analysis in real time are possible. In this study, it is thought that the terminal management board developed for the utilization of the used smart phone can be applied to various fields such as agriculture and environment.

Requirement Analysis of Korean Public Alert Service using News Data (뉴스 데이터를 활용한 재난문자 요구사항 분석)

  • Lee, Hyunji;Byun, Yoonkwan;Chang, Sekchin;Choi, Seong Jong
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.994-1003
    • /
    • 2020
  • In this paper, we investigated the current issues on the KPAS(Korean Public Alert Service) by News analysis. News articles, from May 15, 2005 to April 30, 2020, were collected with the key word of 'KPAS' through the News Big-Data System provided by the Korea Press Foundation. The results of the content analysis are as follows. First, the issues on alert presentation were categorized by alarm sound, message content, alert level, transmission frequency, delay, reception range, time of alert, and language. Issues on inability to receive KPAS messages were categorized into authority, mobile, sending standard, mobile communication infra, etc. For the last two to three years, news on the inability issues had decreased, while news on the presentation issues had increased. This tells us that the public demand for improvement in the KPAS lies in the presentation issues. The demand for societal resolutions to the presentation issues especially on message content, transmission frequency, and reception range has soared.