• 제목/요약/키워드: Al-coated stainless steel

검색결과 30건 처리시간 0.03초

펄스 도금법을 이용한 STS 316L 스테인리스강 상의 저온 염욕 알루미늄 코팅에 관한 연구 (Study of the Al-coating on the STS 316L Stainless Steel by Pulse Plating in the Molten Salts at Room Temperature)

  • 정세진;조계현
    • 한국표면공학회지
    • /
    • 제35권1호
    • /
    • pp.17-32
    • /
    • 2002
  • Electroplating methods by molten salts and non-aqueous melts were employed for aluminium coating on STS 316L stainless steel. After coated with Ni or non-coated surface on stainless steel, Al pulse plating was carried out in two different types of electrolytes at room temperature. The Al layer from $AlCl_3$-TMPAC melts could not obtain appreciable thickness for engineering application due to chemical reactions between deposits and moisture of air. However, The Al coating by pulse plating in the Ethylbenzene-Toluene-$AlBr_3$ systems was found to be solid coating layer with a few $\mu\textrm{m}$ scale. The conductivity of Ethylbenzene-Toluene-$AlBr_3$ electrolyte was as functions of time and agitation. By seven days exposure after mixing of the electrolyte, Al-deposited layer shows uniform and near by pore-free with high current density (higher than 30mA/$\textrm{cm}^2$). The roughness and imperfection of coating layer were decreased with a increasing agitation speed. It was found that the optimum condition for the Al pulse plating on the 316L stainless steel was a 400mA peak current, duty cycle, $t_{on}$ $t_{ off}$=3ms/1ms, and a current density of 30mA/$\textrm{cm}^2$.

고온, 고압 조건에서 n-dodecane 액체연료의 흡열분해를 위한 관벽 내 알루미나 및 촉매 코팅 최적화 연구 (A Study on Optimization of Alumina and Catalysts Coating on Tube Reactor for Endothermic Reaction of n-Dodecane Under Supercritical Conditions)

  • 김성수;이상문;이예환;이동윤;곽지영
    • 한국추진공학회지
    • /
    • 제25권3호
    • /
    • pp.56-61
    • /
    • 2021
  • 본 연구에서는 극초음속 비행체의 냉각제로 사용되는 액체탄화수소 연료와 흡열 촉매의 안정적 사용을 위해 Al2O3와 H-ZSM-5를 stainless steel tube 내벽에 코팅하는 연구를 수행하였다. 액체탄화수소 연료의 흡열분해 반응에서 coke 생성이 불가피하며, stainless steel tube reactor를 냉각채널로 사용하게 됨에 따라 Fe, Ni 금속이 filamentous coke 생성을 유발한다. 이에 따라 stainless steel에 H-ZSM-5를 코팅함으로써, Fe과 Ni 금속이 액체탄화수소 연료에 직접 노출되는 것을 방지하고 filamentous coke 생성을 억제하고자 하였다. 또한 stainless steel과 H-ZSM-5 사이에는 Al2O3을 코팅하여, 부착 강도를 증진 시키고자 하였다.

Al-Si 용융도금된 11%Cr 페라이트 스테인리스강, STS409L GTA 용접부의 미세조직과 경도 (Microstructures and Hardness of Al-Si Coated 11%Cr Ferritic Stainless Steel, 409L GTA Welds)

  • 박태준;공종판;나혜성;강정윤;엄상호;김정길;우인수;이종섭
    • Journal of Welding and Joining
    • /
    • 제28권3호
    • /
    • pp.92-98
    • /
    • 2010
  • Ferritic stainless steels, which have relatively small thermal expansion coefficient and excellent corrosion resistance, are increasingly being used in vehicle manufacturing, in order to increase the lifetime of exhaust manifold parts. But, there are limits on use because of the problem related to cosmetic resistance, corrosions of condensation and high temperature salt etc. So, Aluminum-coated stainless steel instead of ferritic stainless steel are utilized in these parts due to the improved properties. In this investigation, Al-8wt% Si alloy coated 409L ferritic stainless steel was used as the base metal during Gas Tungsten Arc(GTA) welding. The effects of coated layer on the microstructure and hardness were investigated. Full penetration was obtained, when the welding current was higher than 90A and the welding speed was lower than 0.52m/min. Grain size was the largest in fusion zone and decreased from near HAZ to base metal. As welding speed increased, grain size of fusion zone decreased, and there was no big change in HAZ. Hardness had a peak value in the fusion zone and decreased from the bond line to the base metal. The highest hardness in the fusion zone resulted from the fine re-precipitation of the coarse TiN and Ti(C, N) existed in the base metal during melting and solidification process and the presence of fine $Al_2O_3$ and $SiO_2$ formed by the migration of the elements, Al and Si, from the melted coating layer into the fusion zone.

산화물 피복강재의 밀착성과 내식성에 관한 연구 ( 1 ) (Studies on the Adherence and Corrosion Resistance of Oxide Coated Materials ( 1 ))

  • 이종락;임우조
    • 수산해양기술연구
    • /
    • 제32권2호
    • /
    • pp.157-163
    • /
    • 1996
  • To ceramic film, $SiO_2$ and $Al_2O_3$, coated on pure Fe and stainless steel(SUS41O) by RF magnetron sputtering, the adherence between mm and substarte was studied. The adherence index (${\chi}$) was determined by the measure of micro hardness test. Also, the corrosion resistance on oxide coatings was studied using electrochemical measurement. The main results obtained are as the following: 1) In the micro-hardness test, with $1{\mu}m$ thickness mm, it has only one the value of ${\chi}$. Above $2{\mu}$thickness fIlm, however, get another value of ${\chi}$as the cracks in fIlm. 2) The oxide fIlm adhere well on the mild materials such as pure steel than high intensity materials like stainless. 3) Alumina($Al_2O_3$) coated materials have better corrosion resistance than silica($SiO_2$)coated materials

  • PDF

Effectiveness of medical coating materials in decreasing friction between orthodontic brackets and archwires

  • Arici, Nursel;Akdeniz, Berat S.;Oz, Abdullah A.;Gencer, Yucel;Tarakci, Mehmet;Arici, Selim
    • 대한치과교정학회지
    • /
    • 제51권4호
    • /
    • pp.270-281
    • /
    • 2021
  • Objective: The aim of this in vitro study was to evaluate the changes in friction between orthodontic brackets and archwires coated with aluminum oxide (Al2O3), titanium nitride (TiN), or chromium nitride (CrN). In addition, the resistance of the coatings to intraoral conditions was evaluated. Methods: Stainless steel canine brackets, 0.016-inch round nickel-titanium archwires, and 0.019 × 0.025-inch stainless steel archwires were coated with Al2O3, TiN, and CrN using radio frequency magnetron sputtering. The coated materials were examined using scanning electron microscopy, an X-ray diffractometer, atomic force microscopy, and surface profilometry. In addition, the samples were subjected to thermal cycling and in vitro brushing tests, and the effects of the simulated intraoral conditions on the coating structure were evaluated. Results: Coating of the metal bracket as well as nickel-titanium archwire with Al2O3 reduced the coefficients of friction (CoFs) for the bracket-archwire combination (p < 0.01). When the bracket and stainless steel archwire were coated with Al2O3 and TiN, the CoFs were significantly lower (0.207 and 0.372, respectively) than that recorded when this bracket-archwire combination was left uncoated (0.552; p < 0.01). The friction, thermal, and brushing tests did not deteriorate the overall quality of the Al2O3 coatings; however, some small areas of peeling were evident for the TiN coatings, whereas comparatively larger areas of peeling were observed for the CrN coatings. Conclusions: Our findings suggest that the CoFs for metal bracket-archwire combinations used in orthodontic treatment can be decreased by coating with Al2O3 and TiN thin films.

다층 코팅된 Stainless Steel의 고온 내삭마특성 (High Temperature Ablation Behaviors of Multilayer Coated Stainless Steel)

  • 최광수;양원철;김영주;박준식;김민규
    • 한국재료학회지
    • /
    • 제28권3호
    • /
    • pp.135-141
    • /
    • 2018
  • Stainless steel is being used in various industries such as automobile and aerospace for its cheap manufacturing cost and excellent mechanical properties. However, stainless steel failed to stably protect a specimen with a $Cr_2O_3$ protective layer at temperatures above $1000^{\circ}C$. Thus, improving the high temperature flame resistance of the specimen through additional surface coating was needed. In this study, multilayer coatings of YSZ and $Al_2O_3$ were performed on SUS 304 specimens using pack cementation coatings and thermal plasma spray. The multilayer coated specimen showed enhanced thermal properties due to the coated layers. The microstructures and phase stability are discussed together with flame conditions at $1350^{\circ}C$.

페라이트계 스테인리스강의 고온염 부식특성에 관한 연구 (High Temperature Salt Corrosion Property of Ferritic Stainless Steels)

  • 송전영;박중철;안용식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.860-866
    • /
    • 2009
  • It is very important to choose optimal material having good corrosion resistance and capabilities for the part materials such as the automotive exhaust system under a hot salt corrosion atmosphere. Generally, two types of corrosion come into the automotive exhaust system. One is 'Condensate Corrosion', which is occurred by exhaust gas condensate formed at the inner surface of exhaust system heated up during driving, which results in the acid condensate pitting. The other is 'High Temperature Salt Corrosion' occurring from the interaction between the chloride ion coming from salt at the seaside district or snow salt and the outer surface of exhaust system. By the corrosion attack, the main muffler is firstly damaged and the life cycle of an automobile is significantly decreased. It has been investigated that the hot salt corrosion properties of a STS 409L and 436L ferritic stainless steels which are well-known for the materials of the automotive exhaust system. In addition, the corrosion properties of hot dip aluminum coated STS 409L have been compared with uncoated steels. Aluminum coated STS 409L showed a superior corrosion resistance than uncoated STS 409L, and futhermore showed a better corrosion resistance than a STS 436L, which is an expensive ferritic stainless steel having a excellent corrosion resistance caused from more chromium content of an alloying element.

조직생검용 Needle의 세라믹 코팅에 관한 연구 (A Study on the Ceramic Coating of Biopsy Needle)

  • 조성만;정협재;김만태;이경업
    • 한국정밀공학회지
    • /
    • 제26권9호
    • /
    • pp.121-126
    • /
    • 2009
  • Stainless steel 316L (STS 316L) is widely used as a material of biopsy needle. However it has a side effect that tissue can be damaged by electrochemical operation between tissue and STS 316L. Many studies have been made on the ceramic coating of biopsy needle to reduce the side effect. In this study, STS 316L was coated with three bioceramics, $Al_2O_3$, $SiO_2$ and $ZrO_2$ using a RF magnetron sputtering method. The effects of ceramic coating on the electrical conductivity and coating strength of ceramic-coated STS 316L were investigated. The results showed that the electrical conductivity of ceramic-coated STS 316L was much lower than that of uncoated STS 316L. The coating strength of $ZrO_2$-coated STS 316L was 30% and 70% higher, respectively than those of $Al_2O_3$-coated STS 316L and $SiO_2_3$-coated STS 316L.

알루미나이드 확산코팅된 스테인레스 합금의 내산화 및 내삭마 특성 (Oxidation Behaviors and Degradation Properties of Aluminide Coated Stainless Steel at High Temperature)

  • 황철홍;이효민;오정석;황동현;황유석;이종원;최정묵;박준식
    • 한국분말재료학회지
    • /
    • 제28권5호
    • /
    • pp.396-402
    • /
    • 2021
  • Stainless steel, a type of steel used for high-temperature parts, may cause damage when exposed to high temperatures, requiring additional coatings. In particular, the Cr2O3 product layer is unstable at 1000℃ and higher temperatures; therefore, it is necessary to improve the oxidation resistance. In this study, an aluminide (Fe2Al5 and FeAl3) coating layer was formed on the surface of STS 630 specimens through Al diffusion coatings from 500℃ to 700℃ for up to 25 h. Because the coating layers of Fe2Al5 and FeAl3 could not withstand temperatures above 1200℃, an Al2O3 coating layer is deposited on the surface through static oxidation treatment at 500℃ for 10 h. To confirm the ablation resistance of the resulting coating layer, dynamic flame exposure tests were conducted at 1350℃ for 5-15 min. Excellent oxidation resistance is observed in the coated base material beneath the aluminide layer. The conditions of the flame tests and coating are discussed in terms of microstructural variations.

대기용해 시 내화물 도가니의 종류가 가돌리늄(Gadolinium)을 함유한 듀플렉스 스테인레스 강의 미세조직에 미치는 영향 (The Effect of Refractory Crucible on Microstructure of Duplex Stainless Steel Cast with Gadolinium during Air Induction Melting)

  • 안지호;임재한;문병문
    • 한국주조공학회지
    • /
    • 제35권5호
    • /
    • pp.114-119
    • /
    • 2015
  • This paper reports the effect of a refractory crucible type on the microstructure of duplex stainless steel (DSS) cast with the addition of gadolinium using air-induction melting. Grade 4A DSSs with 1 wt% of gadolinium (Gd) were fabricated in various crucibles including alumina ($Al_2O_3$), magnesia (MgO), calcia (CaO) coated with yttria ($Y_2O_3$) and graphite. The standard free energies of the formation of calcium and yttrium oxide were lower than those of gadolinium oxide and other crucible elements based oxide. The yield of Gd in DSS using $Al_2O_3$, MgO, CaO-coated $Y_2O_3$ and graphite was 5, 19, 83 and 96%, respectively. As Gd yield increased, the amount of Gd-based inclusions increased, the size of the inclusions were reduced, and the inclusions became evenly distributed.