• Title/Summary/Keyword: Airflow rate

Search Result 223, Processing Time 0.031 seconds

A Numerical Analysis on the Optimum Design of a Duct with Multiple Outlets in a Medium Bus (중형버스 다출구 덕트의 최적설계에 관한 해석적 고찰)

  • 김민호;천인범;이대훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.223-233
    • /
    • 2002
  • The air distribution duct with multiple outlets is an essential part of automotive air-conditioning system In a bus. The estimation of airflow rate in an automotive air-conditioning duct is typically very complicate due to large variations in cross-sectional area and abrupt changes in flow direction, as well as unbalanced distribution of the flow. In this paper, the flow characteristic in a duct with multiple outlets is investigated through experiment, CFD simulation and a one-dimensional simulation. Numerical simulations have been performed for two simplified air conditioning ducts with multiple outlets used in a medium bus. The three dimensional Navier-Stokes code was used to evaluate the overall pressure, velocity Held, and distribution rate at each diffuser according to the change of various design parameters such as ratio of cross-sectional area and radius of bifurcated region. In addition, a one-dimensional program based on Bernoulli equation was developed to obtain optimized diffuser area required to equalize discharge flow rate at each outlet. As a result of this study, optimized diffuser area of design variable by one-dimensional program was very reasonable as compared to the trend deduced from CFD Simulation. Therefore, the simple and convenient one-dimensional analysis developed in this study can be applied in practical design procedure for air-conditioning duct.

Numerical Study on the Supply and Exhaust Port Size and Fire Management Method in the Semi-transverse Ventilation System for Road Tunnel (도로터널 반횡류환기시스템에서 급배기 포트개도 및 화재시 운영방안에 관한 수치해석적 연구)

  • Ryu, Ji-Oh;Kim, Jin-Su;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.68-74
    • /
    • 2016
  • In semi-transverse ventilation system applied for road tunnel, adjustment of the port opening ratio is an essential part for uniform airflow rate per unit length over the entire tunnel. However, it has not been considered decently throughout the design process and operating of the tunnel. Therefore, in this study, we developed a program for the calculation of the opening size ratio of supply or exhaust port in transverse ventilation system and carried out the research to present a management plan for the port. In supply duct system, the opening size of the port had a tendency to increase and then decrease later when it gradually becomes closer toward the bulkhead at the beginning of the duct the minimum opening degree is to appeared as 56%. In the exhaust system, port size is the smallest at the beginning of duct as 15%, has shown a tendency to increase towards the bulk head. As results of estimating the air flow rate for 300 m intervals, the exhaust flow rate in the center of tunnel appeared to be extremely low as 8.1% and 12.5% when port size is constant and is adjusted supply type. Thus, even if the normal ventilation efficiency is declines, yet it is highly recommend adjusting the port size in order to obtain a uniform flow rate at fire accidents.

Energy Performance of Air-side Economizer System for Data Center Considering Supply Temperature and Design Airflow Rate of CRAH(Computer Room Air Handler) (외기냉방시스템이 적용된 데이터센터 CRAH의 급기온도와 설계 풍량에 따른 에너지성능 분석)

  • Kim, Ji-Hye;Aum, Tae-Yun;Jeong, Cha-Su
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.11
    • /
    • pp.181-188
    • /
    • 2019
  • The purpose of this study is to evaluate the cooling energy saving effects of CRAH supply air temperature(SAT) and design flow rate changes when applying air-side economizer in the data center. MLC(Mechanical Load Component), which is cooling performance indicator of data center, was used to assess the effectiveness of cooling energy savings. It was computed with energy simulation (DesignBuilder) to evaluate the cooling energy performance of 8 different alternatives in a data center. The MLC was 0.31~0.32 regardless of CRAH supply temperature without air-side economizer, and 0.15 to 0.19 value with air-side economizer. That is, cooling energy can be reduced by approximately 40~55% when applying economizer. As the CRAH SAT and design flow rate changed, the MLC values were 0.16 to 0.18 and 0.15 to 0.19, respectively.

Venturi Effects Induced by the Local Ventilation Fan in Large-Opening Room-and-Pillar Mining Sites (대단면 갱내 국부 선풍기의 벤츄리(Venturi) 효과 연구)

  • Lee, Chang Woo;Nguyen, Van Duc
    • Tunnel and Underground Space
    • /
    • v.24 no.6
    • /
    • pp.464-472
    • /
    • 2014
  • In large-opening room-and-pillar mining sites, particularly without the devices for the ventilation control, the airflow pattern created by the local fan operation is too complicated to quantify and also shows low ventilation efficiency. This study aims at performing a series of CFD analysis for the so-called venturi effects of the local fans; the effects of increasing airflow rate along the axis downstream of fan resulting from increased kinetic energy and subsequently decreased static pressure in the downstream. Effects of the fan type and installation height are compared. 1 vane-axial fan and 2 propeller fans are analyzed for their venturi effects, while the vane-axial fan was installed at the height of 1.0, 1.5 and 2.0m for comparison. The results can be applied to improve the economy and efficiency of local fans for securing better air quality and work environment management.

Aerodynamic Characteristics of Young and Elderly Adult Patients with Voice Disorders during Continuous Speech (젊은 성인 및 노인 음성장애 환자의 연속발화시 공기역학적 특성 비교)

  • Pyo, Hwa-young
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.12
    • /
    • pp.270-278
    • /
    • 2019
  • This study was performed to compare the aerodynamic characteristics of young and elderly adult male patients with voice disorders during continuous speech. Aerodynamic measurements were obtained after 12 young male patients and 9 elderly male patients read a paragraph. The elderly group showed longer duration, lower airflow rate and air volume than the younger group, but the differences were not significant except phonation time. So, when interpreting the meaning of aerodynamic measures of elderly voice disorder patients in the aspects of airflow and air volume, it should take into account various conditions(e. g. reading materials, pulmonary functions) as well as age.

A Study on the Air Flow Characteristics in an Apartment Complex and Ventilation Performance of an Individual Unit for Improving IAQ (주동형태 변화에 따른 아파트 단지내 기류분석 및 단위주호의 환기성능에 관한 연구)

  • Lee, Jung-Hyun;Lee, Seung-Hee;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.11-16
    • /
    • 2005
  • The recent trends of high-density and high-rise in apartment housing have caused the problems of decrease in ventilation rates and increase of indoor pollutant contaminants. SHS(Sick House Syndrome) has now become a major issue and threats the health of residents. To solve these indoor air problems, increase in ventilation rate is considered as one of the most efficient approach. Thus, the recent housing development is pursuing improvement in the site design and the layout of apartment building blocks to promote natural ventilation is now investigated as one of the fundamental solutions. This study was focused on the air flow characteristics of outdoor environment in an apartment complex to keep the pollutants out of the site. Age of air and pressure difference have been used as indices of the outdoor air quality. Four different types of apartment building layouts have been analyzed by CFD simulation. This study again selected a real apartment housing complex as a case study model. By analyzing the pressure differences between the front and rear of an apartment building block, the ventilation performance in each individual unit was evaluated, and its impact on ventilation performance is investigated by analyzing the stagnant air around the apartment building blocks. During this process, existing patterns of apartment housing layout have been evaluated, and the most appropriate site layout has been chosen to analyze the outdoor airflow patterns. Based on the analysis of airflow patterns of site layout, the possibilities of improving ventilation performance of an individual apartment housing is proposed.

Application of Bypass Flow for Improving Performance of the Vertical Column Pneumatic Separator (수직(垂直)컬럼형(形) 풍력선별기(風力選別機)의 분리효율향상(分離效率向上)을 위한 bypass유로(流路)의 적용(適用))

  • Lee, Gye-Seung;Song, Young Jun;Yotsumoto, Hiroki
    • Resources Recycling
    • /
    • v.22 no.3
    • /
    • pp.65-72
    • /
    • 2013
  • A vertical column pneumatic separator was modified to improve its separation performance. A branch column was installed at the center of the main column, which created a bypass flow and changed the flow rate of the main column before and after the branch column. To separate a mixture comprising light and heavy materials, the airflow in main column after the branch column was set to lift the only light materials and the airflow in main column before the branch column was set to prevent the flow of the light materials from flowing downwards. Materials directed into the branch column were separated from the flow and returned to the feeder through the cyclone linked to the branch column. The performances of the straight-type separator and the modified separator were compared using glass and zirconia beads with a narrow size distribution.

The Time Responses of Spirometric Values in Response to Single Doses of Inhaled Salbutamol (기관지확장제 사용 후 시간에 따른 폐활량 측정치의 변화)

  • Park, Sun Hyo;Choi, Won-Il;Lee, Sang Won;Park, Hun Pyo;Seo, Yong Woo;Ku, Duk Hee;Lee, Mi Young;Lee, Choong Won;Jeon, Young June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.2
    • /
    • pp.144-150
    • /
    • 2004
  • Background : An assessment of the presence and the degree of reversibility of airflow obstruction is clinically important in patients with asthma or chronic obstructive pulmonary disease. However, the time responses of spirometric parameters in response to bronchodilator have not been well investigated. Methods: We studied 15 patients with asthma. Spirometric and mini-Wright peak expiratory flow measurements were performed at 15, 30, 45, and 60 minutes after using single dose($200{\mu}g$) of inhaled bronchodilator, salbutamol. Results : The mean values of forced expiratory volume in one second($FEV_1$) and forced vital capicaty(FVC) were significantly increased at 60 minutes after using bronchodilator in comparison to 15 minutes. And peak expiratory flow rate measured by either mass flow sensor or mini-Wright peak flow meter were significantly increased at 45 minutes after using bronchodilator in comparison to 15 minutes. Conclusions : To appropriate evaluation of the bronchodilator response in patients with reversible airflow limitation, it would be useful measuring either $FEV_1$ or PEF at the later time point 60 or 45 minutes in comparison to 15 minutes after using bronchodilator.

A Study on the Development of Sleep Monitoring Smart Wear based on Fiber Sensor for the Management of Sleep Apnea (수면 무호흡증 관리를 위한 섬유센서 기반의 슬립 모니터링 스마트 웨어 개발에 관한 연구)

  • Park, Jin-Hee;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.89-100
    • /
    • 2019
  • Sleep apnea, a medical condition associated with a variety of complications, is generally monitored by standard sleep polysomnography, which is expensive and uncomfortable. To overcome these limitations, this study proposes an unconstrained wearable monitoring system with stretch-fiber sensors that integrate with the wearer's clothing. The system allows patients to undergo examinations in a familiar environment while minimizing the occurrence of skin allergies caused by adhesive tools. As smart clothing for adult males with sleep apnea, long-sleeved T-shirts embedding fibrous sensors were developed, enabling real-time monitoring of the patients' breathing rate, oxygen saturation, and airflow as sleep apnea diagnostic indicators. The gauge factor was measured as 20.3 in sample 4. The maximum breathing intake, measured during three large breaths, was 2048 ml. the oxygen saturation was measured before and during breath-holding. The oxygen saturation change was 69.45%, showing a minimum measurable oxygen saturation of 70%. After washing the garment, the gauge factor reduced only to 18.0, confirming the durability of the proposed system. The wearable sleep apnea monitoring smart clothes are readily available in the home and can measure three indicators of sleep apnea: respiration rate, breathing flow and oxygen saturation.

THE INTERNAL FLOW ANALYSIS OF AIR INTAKE FOR THE COOLING OF AIRCRAFT POD (항공기 포드 냉각용 공기흡입관 내부 유동해석)

  • Kim, S.T.;Joung, Y.I.;Cho, S.H.;Moon, W.Y.;Kang, I.M.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.81-85
    • /
    • 2009
  • In this paper, the aerodynamic shape of air intake was investigated for the efficient cooling of electronic equipments in aircraft pod. As a first step, ESDU method was applied for the basic shape design of air intake considering the operational environments. The second step was to confirm the performance on design point, so the internal flow field of air intake was analyzed using a commercial Navier-Stokes code(FLUENT). And also the aerodynamic characteristics of internal flow at off-design condition was investigated with the variations of airflow rate. The results show that the air intake meets the requirement of target performance under the mission environments.

  • PDF