• Title/Summary/Keyword: Airborne monitoring

Search Result 140, Processing Time 1.177 seconds

Airborne HPGe spectrometer for monitoring of air dose rates and surface activities

  • Marcel Ohera;Lubomir Gryc;Irena Cespirova;Jan Helebrant;Lukas Skala
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4039-4047
    • /
    • 2023
  • This contribution describes the application of HPGe detector for the airborne quantitative analysis. The hardware of the airborne HPGe system was designed from the commercial components with only exception of the newly designed AirHPGeSpec special software to control, measure and process the data. The system was calibrated for the local air kerma rates measured on helicopter board and its conversion to the air kerma rates at 1 m above the ground was proposed. Two examples of the air kerma rates measured over the former uranium mining areas are presented and compared with the results of other airborne system on the board. This airborne HPGe system could be also used for measuring the surface activities in a radiation event. The nuclides of 131I, 132Te - 132I, 133I, 134I, 135I, 137Cs, 134Cs, 88Rb and 103Ru were selected from possible nuclear power plant emergency scenarios. The Monte Carlo simulation was used to calculate HPGe detector efficiencies for the flight altitudes from 25 to 300 m for the energies from 300 keV to 3 MeV of the nuclides in question. Also, the detection limits according to the Currie method as well as ISO 11929-2010 for selected nuclides are presented.

From Airborne Via Drones to Space-Borne Polarimetric- Interferometric SAR Environmental Stress- Change Monitoring ? Comparative Assessment of Applications

  • Boerner, Wolfgang-Martin;Sato, Motoyuki;Yamaguchi, Yoshio;Yamada, Hiroyoshi;Moon, Woo-Il;Ferro-Famil, Laurent;Pottier, Eric;Reigber, Andreas;Cloude, Shane R.;Moreira, Alberto;Lukowski, Tom;Touzi, Ridha
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1433-1435
    • /
    • 2003
  • Very decisive progress was made in advancing fundamental POL-IN-SAR theory and algorithm development during the past decade. This was accomplished with the aid of airborne & shuttle platforms supporting single -to-multi-band multi-modal POL-SAR and also some POL-IN-SAR sensor systems, which will be compared and assessed with the aim of establishing the hitherto not completed but required missions such as tomographic and holographic imaging. Because the operation of airborne test-beds is extremely expensive, aircraft platforms are not suited for routine monitoring missions which is better accomplished with the use drones or UAVs. Such unmanned aerial vehicles were developed for defense applications, however lacking the sophistic ation of implementing advanced forefront POL-IN-SAR technology. This shortcoming will be thoroughly scrutinized resulting in the finding that we do now need to develop most rapidly POL-IN-SAR drone-platform technology especially for environmental stress-change monitoring with a great variance of applications beginning with flood, bush/forest-fire to tectonic-stress (earth-quake to volcanic eruptions) for real-short-time hazard mitigation. However, for routine global monitoring purposes of the terrestrial covers neither airborne sensor implementation - aircraft and/or drones - are sufficient; and there -fore multi-modal and multi-band space-borne POL-IN-SAR space-shuttle and satellite sensor technology needs to be further advanced at a much more rapid phase. The existing ENVISAT with the forthcoming ALOSPALSAR, RADARSAT-2, and the TERRASAT will be compared, demonstrating that at this phase of development the fully polarimetric and polarimetric-interferometric modes of operation must be viewed and treated as preliminary algorithm verification support modes and at this phase of development are still not to be viewed as routine modes.

  • PDF

A Study on the Efficient Measurement of Airborne Asbestos Concentrations at Demolition Sites of Asbestos Containing Buildings, etc. in Seoul (서울시내 석면함유 건축물 철거 현장 등에서의 효과적인 공기 중 석면농도 측정을 위한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jeongyeun;Kim, Jihui;Chung, Sooknye;Kim, Jina;Oh, Seokryul;Kim, Iksoo;Shin, Jinho;Eo, Soomi;Jung, Kweon;Lee, Jinsook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.113-121
    • /
    • 2014
  • Objectives: This study is intended to seek credible and efficient measurements on airborne asbestos concentrations that allow immediate action by establishing complementary data through comparative analysis with existing PCM and KF-100 method real-time monitoring equipment in working areas in Seoul where asbestos-containing buildings are being demolished, including living environment surroundings. Materials: We measured airborne asbestos concentrations using PCM and KF-100 at research institutes, monitoring networks, subway stations and demolition sites of asbestos-containing buildings. Through this measurement data and KF-100 performance testing, we drew a conversion factor and applied it via KF-100. Finally we verified the relationship between PCM and KF-100 with statistical methods. Results: The airborne asbestos concentrations by PCM for the objects of study were less than the detection limit(7 fiber/$mm^2$) in three (20%) out of 15 samples. The highest concentration was 0.009 f/cc. The airborne asbestos concentrations by PCM in laboratories, monitoring networks, subway stations and demolition sites of asbestos-containing buildings were respectively $0.002{\pm}0.000$ f/cc, $0.004{\pm}0.001$ f/cc, $0.009{\pm}0.001$ f/cc, and $0.002{\pm}0.000$ f/cc. As a result of KF-100 performance testson rooftops, the conversion factor was 0.1958. Applying the conversion factor to KF-100 for laboratories, the airborne asbestos concentrations ratio of the two ways was nearly 1:1.5($R^2$=0.8852). Also,the airborne asbestos concentration ratio of the two ways was nearly 1:1($R^2$=0.9071) for monitoring networks, subway stations, and demolition sites of asbestos-containing buildings. As a result of independent sample t-tests, there was no distinction between airborne asbestos concentrations monitored in the two ways. Conclusions: In working areas where asbestos-containing buildings are being demolished, including living environment surroundings, quickly and accurately monitoring airborne asbestos scattered in the air around the working area is highly important. For this, we believea mutual interface of existing PCM and a real-time monitoring equipment method is possible.

A Study on Characteristics of Airborne Asbestos Concentrations Using PCM and TEM in Life Environment Surroundings of Seoul (서울지역 생활환경주변의 공기 중 석면분포 특성에 관한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jihui;Oh, Seokryul;Shin, Jinho;Eom, Seokwon;Chae, Youngzoo;Lee, Jinsook;Koo, Jayong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.613-623
    • /
    • 2013
  • This study is purposed to evaluate the airborne asbestos concentrations in life environment surroundings in Seoul. In study, we investigated airborne asbestos concentrations in thirteen subway stations, four monitoring networks and each vicinity roadside, six stream surroundings, four tunnels quarterly and we also investigated relationship between the airborne asbestos concentrations and ambient temperature in monitoring networks and time-based airborne asbestos concentration variability for two typical monitoring networks, two subway stations transferred and used by lots of people through Phase Contrast Microscopy (PCM) and Transmission Electron Microscopy (TEM). The airborne asbestos concentrations by PCM for 4 objects of study were less than the detection limit (7 fiber/$mm^2$) in 111 (50%) out of 223 samples. The highest concentration was 0.0130 f/cc. But additional TEM analysis result for samples exceeding the guideline value for indoor air quality (0.01 f/cc) proposed by the Ministry of Environment (Korea), no asbestos was detected. Similarly TEM analysis result for 124 samples, no asbestos was detected. The average airborne asbestos concentrations by PCM in subway stations, monitoring networks, streams and tunnels were $0.0041{\pm}0.0027$ f/cc, $0.0015{\pm}0.0011$ f/cc, $0.0024{\pm}0.0012$ f/cc and $0.0016{\pm}0.0020$ f/cc. All objects of study were satisfied with the guideline value for indoor air quality. The relationship between the airborne asbestos concentrations and ambient temperature in monitoring networks was generally positive correlation (r = 0.660). The higher ambient temperature was and the more transient population was, the airborne asbestos concentrations by time for two subway stations were increased. While the airborne asbestos concentrations for two monitoring networks showed no variation pattern according to time.

Associations between Airborne Manganese and Blood Manganese in the Korean General Population according to KNHANES 2008-2009 (한국인의 혈중 망간농도와 공기중 망간농도의 관련성)

  • Jung, Kyung Sick;Lee, Jong Dae;Kim, Yong Bae
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1589-1598
    • /
    • 2013
  • The objective of this study was to evaluate associations between airborne manganese and blood manganese in a general population of South Korean adults. The concentrations of airborne manganese in total suspended particulate (TSP) were calculated from data obtained from ambient air-monitoring stations (AAMSs) located in South Korea. Blood manganese data obtained Korean National Health and Nutrition Examination Survey (KNHANES) using a rolling sampling design involving a complex, stratified, multistage, probability cluster survey of a representative sample of the non-institutionalized civilian population of South Korea. Airborne manganese geometric means was 46.10 $ng/m^3$, blood manganese geometric means were 1.19 ${\mu}g/d{\ell}$ for male and 1.40 ${\mu}g/d{\ell}$ for female. In multiple linear regression analysis of log transformed blood manganeseas a continuous variable on airborne manganese, after adjusting for covariates including gender, age, job, smoking and drinking status, education level, BMI (body mass index). Airborne manganese was positively associated with blood manganese with statistical significance. The present study confirms that airborne manganese is a possible contributor to the increase of blood manganese in the adult general population.

Application of a Gas Chromatography/Luminol Detection System for Peroxyacetyl Nitrate Airborne Measurement

  • Khang, Bumju;Ahn, Joon Young;Song, Dasol;Lee, Gangwoong
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.105-113
    • /
    • 2013
  • We constructed and tested an airborne peroxyacetyl nitrate (PAN) monitoring system based on luminol chemiluminescence detection with fast gas chromatography. This system allowed for simultaneous measurement of PAN and nitrogen dioxide ($NO_2$) with a time resolution of <2 min. Actual sample masses within the fixed volume sample loop at various altitudes and temperatures were adjusted to standard atmosphere, using measured pressures and temperatures. The airborne PAN measurement system was evaluated during two field studies above the southern Korean Peninsula in August and October 2009. The detection limit based on the ISO approach was 0.035 ppbv PAN, well below the observed concentrations of 0.185-1.49 ppbv during these studies. Under these conditions, the PAN mixing ratios were positively correlated with $O_x$ ($O_x=O_3+NO_2$), with slopes varying between 0.014 and 0.033 and intercepts between 22.6 and 55.1 ppbv $O_x$. The intercepts corresponded roughly to background $O_x$ mixing ratios in central Europe; however, the slopes were above the range of slopes reported in other studies. We also enhanced the durability, safety, and ease of maintenance of the PAN monitoring system by redesigning the structure of the conventional luminol cell.

Full spectrum estimation of helicopter background and cosmic gamma-ray contribution for airborne measurements

  • Lukas Kotik;Marcel Ohera
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1052-1060
    • /
    • 2023
  • The airborne radiation monitoring has been used in geophysics for more than forty years and now it also has its important role in emergency monitoring. The aircraft background and the cosmic gamma-rays contribute to the measured gamma spectrum on the aircraft board. This adverse effect should be eliminated before the data processing. The paper describes two semiparametric methods to estimate the full spectrum aircraft background and cosmic gamma-ray contribution from spectra measured at altitudes where terrestrial contribution is negligible. The methods only assume to know possible peak positions in spectra and their full width at half maximum, that can be easily obtained e.g. from terrestrial measurement. The methods were applied to real experimental data acquired on Mi-17 and Bell 412 helicopter boards. The IRIS airborne gamma-ray spectrometer, with 4×4 L NaI(Tl) crystals, produced by Pico Envirotec Inc., Canada, was used on helicopters' boards. To obtain valid estimate of the aircraft background and the cosmic contribution, the measurements over sea and large water areas were carried out. However, the satisfactory results over inland were also achieved comparing with those acquired over large water areas.

A Study on Concentration, Identification, and Reduction of Airborne Microorganisms in the Military Working Dog Clinic

  • Kim, Min-Ho;Baek, Ki-Ook;Park, Gyeong-Gook;Jang, Je-Youn;Lee, Jin-Hong
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.517-525
    • /
    • 2020
  • Background: The study was planned to show the status of indoor microorganisms and the status of the reduction device in the military dog clinic. Methods: Airborne microbes were analyzed according to the number of daily patient canines. For identification of bacteria, sampled bacteria was identified using VITEK®2 and molecular method. The status of indoor microorganisms according to the operation of the ventilation system was analyzed. Results: Airborne bacteria and fungi concentrations were 1000.6 ± 800.7 CFU/m3 and 324.7 ± 245.8 CFU/m3. In the analysis using automated identification system, based on fluorescence biochemical test, VITEK®2, mainly human pathogenic bacteria were identified. The three most frequently isolated genera were Kocuria (26.6%), Staphylococcus (24.48%), and Granulicatella (12.7%). The results analyzed by molecular method were detected in the order of Kocuria (22.6%), followed by Macrococcus (18.1%), Glutamicibacter (11.1%), and so on. When the ventilation system was operated appropriately, the airborne bacteria and fungi level were significantly decreased. Conclusion: Airborne bacteria in the clinic tend to increase with the number of canines. Human pathogenic bacteria were mainly detected in VITEK®2, and relatively various bacteria were detected in molecular analysis. A decrease in the level of bacteria and fungi was observed with proper operation of the ventilation system.

Monitoring Airborne Nanoparticle Concentrations by Task in a Laboratory Making Carbon Nanotube Films (탄소나노튜브 필름 제조 실험실의 세부작업별 공기 중 나노입자 노출 농도)

  • Ha, Ju-Hyun;Shin, Yong-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.4
    • /
    • pp.248-255
    • /
    • 2010
  • Airborne nanoparticle concentrations in three metrics (particle surface area concentration, particle number concentration, and particle mass concentrations) were measured by task in a laboratory making carbon nanotubes (CNTs) films using three direct reading instruments. Because of the conducted other researcher's experiment before the tasks, airborne nanoparticle surface area and number concentrations are the highest at the first time conducted weighing and mixing by sonication task, respectively. Because of the mist generated during mixing by sonication, the highest airborne nanoparticle surface area and PM1 concentrations were measured in the task among the total. Nanoparticle surface area concentrations at the researchers' breathing zones had high correlation (r=0.93, p<0.01) with those measured at an area in the laboratory. This result indicates that nanoparticles generated during the experiment contaminated the whole room air. When the experiment performed all the fume hoods weren't operated and making CNTs films task were conducted in the out of the fume hoods. In conclusion, researchers performing making CNTs film experiments were exposed to airborne nanoparticles generated during the experiment without adequate controls. We recommend that adequate controls should be implemented so that workers' exposures to airborne nanoparticle are limited to minimum levels.

Coastal Erosion Time-series Analysis of the Littoral Cell GW36 in Gangwon Using Seahawk Airborne Bathymetric LiDAR Data (씨호크 항공수심라이다 데이터를 활용한 연안침식 시계열 분석 - 강원도 표사계 GW36을 중심으로 -)

  • Lee, Jaebin;Kim, Jiyoung;Kim, Gahyun;Hur, Hyunsoo;Wie, Gwangjae
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1527-1539
    • /
    • 2022
  • As coastal erosion of the east coast is accelerating, the need for scientific and quantitative coastal erosion monitoring technology for a wide area increases. The traditional method for observing changes in the coast was precision monitoring based on field surveys, but it can only be applied to a small area. The airborne bathymetric Light Detection And Ranging (LiDAR) system is a technology that enables economical surveying of coastal and seabed topography in a wide area. In particular, it has the advantage of constructing topographical data for the intertidal zone, which is a major area of interest for coastal erosion monitoring. In this study, time series analysis of coastal seabed topography acquired in Aug, 2021 and Mar. 2022 on the littoral cell GW36 in Gangwon was performed using the Seahawk Airborne Bathymetric LiDAR (ABL) system. We quantitatively monitored the topographical changes by measuring the baseline length, shoreline and Digital Terrain Model (DTM) changes. Through this, the effectiveness of the ABL surveying technique was confirmed in coastal erosion monitoring.