Abstract
Airborne nanoparticle concentrations in three metrics (particle surface area concentration, particle number concentration, and particle mass concentrations) were measured by task in a laboratory making carbon nanotubes (CNTs) films using three direct reading instruments. Because of the conducted other researcher's experiment before the tasks, airborne nanoparticle surface area and number concentrations are the highest at the first time conducted weighing and mixing by sonication task, respectively. Because of the mist generated during mixing by sonication, the highest airborne nanoparticle surface area and PM1 concentrations were measured in the task among the total. Nanoparticle surface area concentrations at the researchers' breathing zones had high correlation (r=0.93, p<0.01) with those measured at an area in the laboratory. This result indicates that nanoparticles generated during the experiment contaminated the whole room air. When the experiment performed all the fume hoods weren't operated and making CNTs films task were conducted in the out of the fume hoods. In conclusion, researchers performing making CNTs film experiments were exposed to airborne nanoparticles generated during the experiment without adequate controls. We recommend that adequate controls should be implemented so that workers' exposures to airborne nanoparticle are limited to minimum levels.