• Title/Summary/Keyword: Airborne asbestos

Search Result 50, Processing Time 0.021 seconds

A Study on Worker Exposure Level and Variation to Asbestos in some Asbestos Industries (일부 석면취급사업장의 석면폭로 농도 및 작업환경관리 기준에 관한 연구)

  • Oh, Se Min;Shin, Yong Chul;Park, Doo Yong;Park, Dong Uk;Chung, Kyou Chull
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.100-109
    • /
    • 1993
  • This study was performed to evaluate the asbestos exposure levels and variations in textile, brake lining manufacturing and slate manufacturing industries. For this study, fifteen plants of brake lining manufacturing industry, 7 plants of textile industry, and 2 plants of slate manufacturing industry were selected and surveyed. Geometric means (GMs) of airborne asbestos concentrations in textile, brake lining manufacturing, and slate manufacturing industries were 1.42 f/cc(0.07-6.1O f/cc), 0.19 f/cc(<0.01-2.67 f/cc) and 0.08 f/cc(0.02-0.67 f/cc), respectively. In textile industry overall GMs of airborne asbestos concentrations in plants with less than 50 workers and in plants with more than 50 workers were 1.60 f/cc and 0.3 f/cc, respectively. Therefore, the size of plant showed some difference in the airborne asbestos concentrations. Three out of 7(42.9%) exceed the Korean standard, 2 f/cc, and every plant exceed the USA standard, 0.2 f/cc of the OSHA-Permissible Exposure Level(OSHA-PEL). Especially, one plant showed the highest average concentration of 2.87 f/cc. In brake lining manufacturing industry, the plants with less than 50 workers showed 0.22 f/cc. The plants with more than 50 workers showed 0.18 f/cc. All plants showed the exposure level below the Korean standard. Five of 15 (33.3%) were above the OSHA-PEL. One plant showed the highest average concentraton of 0.84 f/cc. In slate manufacturing industry, the average exposure level was 0.08 f/cc, and all of the plants were below the Korean standard and the OSHA-PEL.

  • PDF

Risk Assessment of Baby Powder Exposure through Inhalation

  • Moon, Min-Chaul;Park, Jung-Duck;Choi, Byung-Soon;Park, So-Young;Kim, Dong-Won;Chung, Yong-Hyun;Hisanaga, Naomi;Yu, Il-Je
    • Toxicological Research
    • /
    • v.27 no.3
    • /
    • pp.137-141
    • /
    • 2011
  • This study was conducted to assess the exposure risk through inhalation to baby powder for babies and adults under simulated conditions. Baby powder was applied to a baby doll and the amount of baby powder consumed per application was estimated. The airborne exposure to baby powder during application was then evaluated by sampling the airborne baby powder near the breathing zones of both the baby doll and the person applying the powder (the applicator). The average amount of baby powder consumed was 100 mg/application, and the average exposure concentration of airborne baby powder for the applicator and baby doll was 0.00527 mg/$m^3$ (range 0.00157~0.01579 mg/$m^3$) and 0.02207 mg/$m^3$ (range 0.00780~0.04173 mg/$m^3$), respectively. When compared with the Occupational Exposure Limit of 2 mg/$m^3$ set by the Korean Ministry of Labor and the Threshold Limit Value (TLV) of 2 mg/$m^3$ set by the ACGIH (American Conference of Governmental Industrial Hygienists), the exposure concentrations were much lower. Next, the exposure to asbestos-containing baby powder was estimated and the exposure risk was assessed based on the lung asbestos contents in normal humans. As a result, the estimated lung asbestos content resulting from exposure to asbestos-containing baby powder was found to be much lower than that of a normal Korean with no asbestos-related occupational history.

A Study on Exposure to Asbestos a Shipbuilding Repair Business (수리조선 작업장에서의 공기중 석면 노출에 관한 연구)

  • Sim, Sang-Hyo;Chung, Hee-Tae;Song, Ki-Min;Kim, Yoon-Shin;Kang, Yong-Seon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.4
    • /
    • pp.279-284
    • /
    • 2008
  • This paper aims to provide basic data for work environment control, prevention of worker exposure to asbestos and improvement of air quality to protect workers ‘health after measuring the level of airborne asbestos and workers' exposure in a shipbuilding repair businesses. For this study, a total of 27 samples were collected from 27 workers who had been exposed to asbestos during engine, piping, boiler and other manufacturing processes in 'A' Shipbuilding Repair Company in Gyeongnam. This research was conducted from Oct. 1 to 30, 2007 and had the following results: The target group (27 workers) consisted of all men with an average age of 35.9 years and 6.6 years of work on average. Among them, fifteen 15 (55.6%) were smokers. In terms of their duties at work, there were 12 plumbing repair engineers (44.4%), 8 boiler repair engineers (29.6%) and 7 engine engineers (25.9%). The geometric mean concentration of airborne asbestos was 0.004 f/cc. A total of 4 samples exceeded the exposure limit. In particular, three exceeded the legal limit by more than double, which means that some workers have been highly exposed to asbestos. In terms of the concentration of asbestos fibres by work process, plumbing repair was the highest (0.0071 f/cc($0.001{\sim}0.57\;f/cc$)) while boiler was the lowest (0.0015 f/cc($0.001{\sim}0.007\;f/cc$)). Based on this study, proper action needs to be taken as soon as possible to protect workers from the threat of asbestos.

Improvement of Image Processing Algorithm of High-Throughput Microscopy for Automated Counting of Asbestos Fibers (석면섬유 자동계수를 위한 고효율 현미경법의 영상처리 알고리즘 개선)

  • Cho, Myoung-Ock;Yoon, Seonghee;Han, Hwataik;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.3
    • /
    • pp.15-19
    • /
    • 2015
  • We developed a high-throughput microscopy (HTM) method which enabled us to replace a conventional phase contrast microscopy (PCM) method that has been used as a standard analytical method for airborne asbestos. We could obtain the concentration of airborne asbestos fibers under detection limit by automated image processing and analysis using HTM method. Here we propose an improved image processing algorithm with variable parameters to enhance the accuracy of the HTM analysis. Since the variable parameters that compensate the difference of the brightness are applied to the individual images in our new image processing method, it is possible to enhance the accuracy of the automatic image analysis method for sample slides with low asbestos concentration that caused errors in binary image processing. We demonstrated that enumeration of fibers by improved image processing algorithm remarkably enhanced the accuracy of HTM analysis in comparison with PCM. The improved HTM method can be a potential alternative to conventional PCM.

Melting Characteristics of Asbestos Cement Slate on Basicity Control (염기도 조절에 의한 석면슬레이트 용융특성)

  • Yun, Jinhan;Keel, Sangin;Min, Taijin;Lee, Chungkyu;Jang, Duhun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.159.2-159.2
    • /
    • 2010
  • Asbestos is the collective name for a group of naturally occurring minerals in their fibrous form and hydrous silicates of magnesium and a mineral fiber that has been used commonly in a variety of building construction materials for insulation and as a fire-retardant. Asbestos has been used for a wide range of manufactured goods, because of its fiber strength and heat resistant properties. Nevertheless harmful of asbestos is quite serious. Exposure to airborne friable asbestos may result in a potential health risk because persons breathing the air may breathe in asbestos fibers. Continued exposure can increase the amount of fibers that remain in the lung. Fibers embedded in lung tissue over time may cause serious lung diseases including asbestosis, lung cancer. In this paper, we carried out as fundamental study for dispose of asbestos cement slate safely and perfectly. Melting Temperature of asbestos need to more than $1,520^{\circ}C$ and specially asbestos cement slate need more energy than that of pure asbestos. We need to decrease melting temperature of asbestos cement slate for economical efficiency. To the purpose, glass and bottom ash were chosen as additives for basicity control. we analyzed about properties of asbestos cements slate, melting characteristics on the additives ratio and temperature. We confirmed about harmlessness of melting slag through analysis of scanning electron microscope(SEM) and x-ray diffractometer(XRD).

  • PDF

Health Risk Assessment and Evaluation of Asbestos Release from Asbestos-cement Slate Roofing Buildings in Busan (부산시내 석면슬레이트지붕 건축물로부터의 석면 노출 및 건강위해성 평가)

  • Jeong, Jae-Won;Cho, Sunja;Park, Geun-Tae;Lee, Sang-Joon
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1579-1587
    • /
    • 2013
  • This study was performed to evaluate the asbestos exposure levels and to calculate excess lifetime cancer risk (ELCR) for the risk assessment of the asbestos fibers released from asbestos-cement slate roofing (ASR) building. Total number of ASR buildings was into 21,267 in Busan, and 82.03 percent of the buildings was residential houses, and 43.61 percent of the buildings was constructed in 1970s. For this study, ten buildings were selected randomly among the ASR buildings. The range of airborne asbestos concentration in the selected ten ASR buildings was from 0.0016 to 0.0067 f/mL, and the concentration around no-admitted ASR buildings was higher than that around admitted buildings. The ELCR based on US EPA IRIS (integrated risk information system) model is within 3.5E-05 ~ 1.5E-04 levels, and the ELCR of no-admitted ASR buildings was higher than 1.0E-04 (one person per million) level that is considered a more aggressive approach to mitigate risk. These results indicate that the cancer risk from ASR buildings is higher than other buildings, and systematic public management is required for control of no-admitted ASR buildings within near future.

The Characteristics of Dispersed Asbestos Fibers Produced From Building Materials (건축재료에서 발생되는 석면입자의 특성 연구)

  • 유성환
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.191-199
    • /
    • 1993
  • This paper describes the results of a systematic study to determine the characteristics of particle generated from various types of asbestos containing material(ACM) and manmade fiber material(MMFM) during operations of cutting and grinding in laboratory and workplace. Tests were conducted with a specially designed glove box which allowed complete sampling of the generated asbestos fibers. Specificially, air measurements were made during ACM and MMFM installation in building. All personal air samples collected were identified by polarized light microscopy(PLM), X-ray diffraction(XRD) and scanning electron microscope with energy dispersive X-ray analysis(SEM/EDXA). Also, the samples were counted by phase contrast microscope(PCM) in order to compare the results with the permissible exposure standard for workplace. Results indicate that the characterisitcs of fibers found in the roofing sheet, the ceiling and the wall insulation boards were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of rock wool. The concentrations of airborne fibers from various building materials cut by a grinder for 5 minutes were in the ranges of 0.09 $\sim$ 1.71 fibers/cc(f/cc). The highest concentration(1.71f/cc) was found during grinding the wall insulation board which also contains rock wool. The airborne fiber concentrations generated by installing at workplace were ranged from 0.0009 to 0.029 f/cc. All asbestos fibers from the ceiling insulation board at workplace were less than 20$\mu$m in length and more than 20% of them had the average aspect ratio greater than 20. Therefore, for the purpose of decreasing asbestos and man-made fiber concentrations at the workplace, the ceiling and wall board should use strong binding material to increase the binding force with fiber. Also, the permissible exposure standard for workplace(2.0f/cc) in Korea should be constituted below the maximum avaiable concentration measured at glove box.

  • PDF

Asbestos Exposure and Health Risk Assessment in Asbestos-Containing Buildings (석면함유 건축물의 석면 노출 및 위해성 평가)

  • Jeong, Jae-Won;Kim, Kwang-Su;Cho, Sun-Ja;Lee, Sang-Joon
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1069-1078
    • /
    • 2012
  • This study was performed to evaluate the asbestos exposure levels and to calculate excess lifetime cacer risks(ELCRs) in asbestos-containing buildings for maintenance and management. The range of airborne asbestos concentration of 33 buildings was 0.0018 ~ 0.0126 f/cc and one site exceeded indoor air-quality recommended limit 0.01 f/cc. And ELCRs based on US EPA IRIS(Integrated risk information system) model are 1.5E-06 ~ 3.9E-05 levels, and there was no site showed 1.0E-04 (one person per million) level or more, and 11 sites showed 1.0E-05 (one person per 100,000 people) level or more. To prevent the release of asbestos fibers, it needs operation and maintenance of asbestos-containing building materials, and there are some methods such as removal, repairment, enclosure and encapsulation. In conclusion, a risk-based air action level for asbestos in air is an appropriate metric for asbestos-containing building management.

Ship Repair Workers' Exposure to Asbestos by a Systematic Review in Korea (문헌 조사를 통한 국내 선박 수리 작업자들의 석면 노출 특성 분석)

  • Choi, Sang-Jun;Kwon, Hyo-Jung;Gwak, Su-Gyeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.135-141
    • /
    • 2012
  • This study was conducted to evaluate the characteristics of exposure to asbestos for ship repair workers in Korea by a systematic review. The number of articles studying asbestos exposure levels from ship repair workplaces was found to be 4. All asbestos concentration reported as either geometric mean and geometric standard deviation or ranges were transformed to arithmetic mean to estimate exposure level. In addition, weighted arithmetic means(WAMs) were calculated by weighing of the different number of samples. The WAM concentrations were 2.746 f/cc during asbestos dismantling work, 0.034 f/cc before asbestos dismantling work and 0.065 f/cc after working respectively. The maximum airborne concentration of asbestos during asbestos removal work was 7.02 f/cc which was 70 times higher than the occupational exposure limit of Korea, 0.1 f/cc. This study recommends that retrospective exposure to asbestos based on various ship types and operations should be assessed.

Characteristics of Generated Fibrous/Particulate Matters from Asbestos-Containing Building Materials(ACBMs) (해체·제거 작업 시 석면함유 건축자재에서 발생되는 섬유 및 입자상 물질의 특성)

  • Choi, Sungwon;Jang, Kwang Myoung;Park, Kyung Hoon;Kim, Dae Jong;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.184-193
    • /
    • 2015
  • Objectives: This study focused on three aspects: characterizing concentrations of airborne particles by size distributions and asbestos fibers generated by various building materials; analyzing the characteristics of fibers produced by each simulation and asbestos fibers released from ACBMs; and investigating correlations of airborne asbestos fibers and particles generated and association of particle and asbestos concentrations. Methods: We selected three ACBMs including an insulation board, cement asbestos slate and wallboard. We constructed 4 scenarios; a) crushing with a hammer; b) cutting with a industrial knife; c) brushing with a metal brush; and d) tightening & loosening with a hand drill. We implemented one simulation for 30 seconds followed by 30 seconds resting period. We repeated a total of 5 cycles for 5 minutes. Results: The highest concentration of particulate & fibrous matters was from crushing with a hammer in each scenario followed by brushing with a metal brush, cutting with a industrial knife, and tightening & loosening with a hand drill. For ACBMs studied, asbestos concentrations were highest from an insulation board followed by cement asbestos slate, and wallboard. No difference in terms of concentration was found between an insulation board and asbestos slate. Fibers with $5{\sim}20{\mu}m$ in length were included in 76~90% of total fibrous matters. The distribution of the straight form fibers was greater than that of the curl form. About 90% of $PM_{Total}$ released from ACBMs was consisted of $PM_{10}$ while only 10% of $PM_{Total}$ was $PM_{2.5}$. Particulate matters like $PM_{2.5}$ was significantly correlated with fibrous matters($R^2=0.81$). Conclusions: We found ACBMs can significantly release asbestos fibers as well as $PM_{2.5}$. Concentrations of asbestos generated by ACBMs were well correlated with $PM_{2.5}$.