• Title/Summary/Keyword: Airborne

Search Result 1,718, Processing Time 0.03 seconds

An Eight-directional Airborne Chloride Collection Method for the Application of an Appropriate Anti-corrosive Material for Each Side of a Building

  • Cho, Gyuhwan;Yeo, Inhwan;Park, Dongcheon
    • Architectural research
    • /
    • v.18 no.2
    • /
    • pp.75-82
    • /
    • 2016
  • To secure the anticorrosive performance of structures in the oceanic environment it is necessary to select appropriate finishing materials and thickness of cover. However, airborne chloride deposition varies depending on the collector used, and it is difficult to select appropriate finishing materials. For this reason, an eight-directional collector is proposed in this study through reviewing the differences between existing airborne chloride collectors and the new one. To analyze airborne chloride deposition according to the direction from which it flows and verify the performance of the collector proposed in this study, airborne chlorides were deposited on the collector for one year at five different locations in an oceanic environment. From the experiment, it was verified that in terms of direction, there were differences in airborne chloride deposition of up to more than 1.5 times. Based on these research findings, the anti-corrosive method applied can be different for each side of a building's structure, and this is believed to serve as an effective and systemic chloride resistance design.

Distribution Characteristics of Airborne Bacteria in Organic-Waste Resource Facilities (유기성 폐기물 자원화 시설에서 발생되는 부유 세균의 분포 특성)

  • Kim, Ki-Youn;Ko, Han-Jong;Kim, Dae-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.151-158
    • /
    • 2012
  • Objectives: Bioaerosols released by treating organic-waste resources cause a variety of environmental and hygiene problems. The objective of this study was to investigate the distribution characteristics of the airborne bacteria emitted from a pig manure composting plant, a principal site for organic-waste resource facilities. Methods: Three types of pig manure composting plant were selected based on fermentation mode: screw type, rotary type and natural-dry type. Each site was visited and investigated on a monthly basis between September 2009 and August 2010. A total of 36 air samplings were obtained from the pig manure composting plants. The air sampling equipment was a six-stage cascade impactor. Quantification and qualification of airborne bacteria in the air samples was performed by agar culture method and identification technique, respectively. Results: The mean concentrations of airborne bacteria in pig manure composting plant were 7,032 (${\pm}1,496$) CFU $m^{-3}$ for screw type, 3,309 (${\pm}1,320$) CFU $m^{-3}$ for rotary type, and 5,580 (${\pm}1,106$) CFU $m^{-3}$ for natural dry type. The screw type pig manure composting plant showed the highest concentration of airborne bacteria, followed by the natural dry type and the rotary type. The ratio of respirable to total airborne bacteria was approximately 40-60%. The predominant genera of airborne bacteria identified were Micrococcus spp., Staphylococcus spp. and Escherichia spp. Conclusion: Monthly levels of airborne bacteria were highest in August and lowest in November regardless of fermentation mode. There was no significant correlation relationship between airborne bacteria and environmental factors such as temperature, relative humidity and particulate matters in pig manure composting plants.

Characterization of Worker Exposure to Airborne Asbestos in Asbestos Industry (석면취급 사업장 근로자의 석면폭로 특성에 관한 연구)

  • Paik, Nam Won;Lee, Young Hwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.144-153
    • /
    • 1991
  • This study was conducted to evaluate worker exposure to airborne asbestos fibers by industry, and to evaluate polarized-light microscopy for determining airborne asbestos fibers. A total of 11 plants including asbestos textile, brake-lining manufacturing, slate manufacturing, and automobile maintenance shops were investigated. Rsults of the study are summarized as follows. 1. Worker exposure levels to airborne asbestos fibers were the highest in asbestos textile industry, followed by brake-lining manufacturing, slate manufacturing, and automobile maintenance shops, in order. In asbestos textile industry, large variation of asbestos levels was found by plants. The worst plant indicated airborne fiber concentrations in excess of 10 fibers/cc, however, the best plant showed concentrations within 0.50 fibers/cc. 2. Characterization of airborne fibers by industry indicated that fibers from asbestos textile industry were the longest with the largest aspect ratio. Fibers from automobile maintenance shops were the shortest with the smallest aspect ratio. Based on characteristics of fibers and the highest levels of concentrations, it is concluded that workers in the asbestos textile industry are exposed to the highest risk of producing asbestosis, lung cancer, and mesothelioma. 3. Result s obtained using polarized-light microscopy were $43.7{\pm}12.3%$ of the results obtained using phase contrast microscopy. This may be resulted from the worse resolution of polarized-light microscopy than that of phase contrast microscopy. Based on the results, it is recommended that polarized-light microscopy be used for mainly bulk sample analyses and further study be performed to improve the method for determining airborne samples. However, polarized-light microscopy can be used for determining thick fibers.

  • PDF

Concentration of Airborne Fungi in Public Transportation during Operation (운행 중 대중교통차량 내 부유진균 농도 분석)

  • Kim, Hong-Gi;Cho, Eun-Min;Jeon, Bo-Il;Lee, Jeong-Hun;Kim, Ho-Hyun;Kwon, Hyuk-ku
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.757-763
    • /
    • 2020
  • Objectives: The objective of this study was to evaluate the concentrations of airborne fungi in public transportation from autumnl 2016 to summer 2017. Methods: This study measured the concentrations of airborne fungi on six subway lines and intercity buses in Seoul. Results: The concentration of fungi in the air in public transportation was found to be lower than the standard (500 CFU/㎥) for vulnerable group facilities among public use facities. In summer, the concentration of airborne fungi was relatively higher than in autumn. The concentrations of airborne fungi in subway (252.0 CFU/㎥) and train (45.1 CFU/㎥) were high tendency during non-rush hours in summer, while intercity bus was hightendency during rush hours in summer (111.9 CFU/㎥). The major types of airborne fungi in public transportation were Cladosporium, Penicillium, and Aspergillus. Conclusions: The harmful airborne fungus were detected though they did not exceed the standard in all public transportation. As a result, further studies on the analysis of the distribution of airborne fungi by ventilation and the characterization of indoor environments are needed to propose effective management of airborne fungi in public transportation.

Relationship between Office Residents' Activities and Concentration Distribution of Particulate Contaminants Distribution by Operation of Air Cleaner (공기정화기 가동에 따른 사무실 재실자들의 행동성과 입자상 오염물질의 농도 분포 관계에 관한 연구)

  • Kim, Ki-Youn;Park, Jae-Beom;Kim, Chi-Nyon;Lee, Kyung-Jong
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.250-254
    • /
    • 2007
  • The reduction efficiency of air cleaner on particulate contaminants such as dust, airborne bacteria and fungi distributed in the office was relatively higher in case of office with workers than office without workers. This result would be attributed to workers' activities and physical characteristics of particulate contaminants. The air cleaner decreased a concentration of airborne bacteria more than airborne fungi, which implicates that difference of dust adsorption between airborne bacteria and fungi would affect an operation efficiency of air cleaner.

Evaluation of the Distribution Characteristics of Airborne Chlorides by Eight-directional collection method (8방향 포집방식에 따른 대기 중 비래염분의 분포특성 평가)

  • Cho, Gyu-Hwan;Lee, Yong-Jun;Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.98-99
    • /
    • 2014
  • The newly developed eight-directional collector was installed at five different locations in the coastal area after its functionality was verified through experiments. Based on the airborne chloride amount measured for one year, the distribution characteristics of airborne chlorides were examined by direction. In terms of direction, a large amount of airborne chlorides was collected, not only in the direction facing the coast but also in the opposite direction. The amount measured at effective three directions was 1.5 times that measured at non-effective three directions.

  • PDF

Attachment Rate Analysis of Airborne Chlorides by Construction Finish Material to Measure the Amount of Chlorides on the Surface (표면염화물량 산정을 위한 건축마감재별 비래염분 부착율 분석)

  • Cho, Gyu-Hwan;Ji, Dong-Hun;Jung, Jae-Min;Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.57-58
    • /
    • 2014
  • For durability design to protect against chloride-induced corrosion, it is important to estimate the amount of chlorides on the surface. However, it is difficult to estimate the airborne chlorides, a boundary condition, due to the difference between the amount of chlorides attached to a surface of an actual structure and that in the air. Therefore, in this study the attachment rate analysis of airborne chlorides was evaluated for 13 types of finish materials. As a result, despite differences in the amount of airborne chlorides according to the finishing type, it was found that 60 percent of airborne chlorides were attached to mortar, 30 percent were attached to steel, and 25 percent were attached to tiles compared with the amount of chlorides in the air.

  • PDF

Method Development for Estimating Concentration of Airborne Fungi Using a Thermal Imaging Camera (열화상 카메라를 이용한 공기 중 부유 진균 농도 추정방법 개발에 관한 연구)

  • Kim, Ki Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.465-471
    • /
    • 2015
  • Objectives: An objective of this study is to apply a thermal image camera which shows various color according to temperature of indoor surface for estimating concentration of airborne fungi. Materials and Methods: While wall temperature were monitored by applying the thermal image camera, airborne bacteria as well as air temperature and relative humidity have been measured in lecture room and toilet of university for seven months. Results: Based on the results obtained from this study, the ranges of temperature and airborne fungi concentration were $20{\sim}24^{\circ}C$ and $20{\sim}400cfu/m^3 $ for red image, $17.5{\sim}20^{\circ}C$ and $35{\sim}150cfu/m^3$ for orange image, $15.5{\sim}17.5^{\circ}C$ and $25{\sim}650cfu/m^3$ for sky-blue image, and $13.5{\sim}15.5^{\circ}C$ and $50{\sim}200cfu/m^3$ for blue image, respectively. The color of indoor surface taken shot by thermal image camera showed consistent trend with temperature of indoor surface. There is, however, little correlation between color of indoor surface and airborne fungi concentration(p>0.05). Among environmental factors, relative humidity in indoor air showed a significant relationship with airborne fungi concentration(p<0.05). Conclusions: The more measurement data for proving statistically an association between color of indoor surface and airborne fungi concentration should be provided to easily estimate indoor level of airborne fungi.

Investigation on Concentrations and Correlations of Airborne Microbes and Environmental Factors in the General Hospital (종합병원내 부유 미생물 농도 및 환경 요인과의 상관성 조사)

  • Lee, Chang-Rae;Kim, Ki-Yeon;Kim, Chi-Nyon;Park, Dong Uk;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.45-51
    • /
    • 2005
  • This survey was performed to measure concentrations of airborne microbes, utilizing the six-stage cascade air sampler, according to the sampling site and time in the general hospital and to evaluate the degree of correlations between airborne microbes and environmental factors. Besides the main lobby, airborne microbes and environmental factors were not significantly different between the forenoon(9:00-10:00 AM) and afternoon(2:00-3:00 PM). Concentrations of airborne bacteria and fungi were 404 and $156CFU/m^3$ in the main lobby, 188 and $56CFU/m^3$ in the intensive care unit, 323 and $96CFU/m^3$ in the ward, 239 and $127CFU/m^3$ in the laboratory, and 139 and $33CFU/m^3$ in the newborn baby room, respectively. As a result, the level of airborne microbes was significantly highest in the main lobby and lowest in the newborn baby room(p<0.05). Outdoor airborne microbes concentrations were significantly lower than those of the sampling sites in the general hospital except for the newborn baby room(p>0.05). It was observed that temperature, relative humidity and carbon dioxide in the general hospital had generally positive correlation with airborne microbes. However, there was no correlation between the odor index level and airborne microbes.

Profile of airborne microorganisms distributed in general offices (일반 사무실 실내공기 내 부유미생물의 분포 양상)

  • Kim, Ki Youn;Roh, Young Man;Kim, Yoon Shin;Lee, Cheol Min;Sim, In Suk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.1
    • /
    • pp.11-19
    • /
    • 2008
  • Mean levels of airborne bacteria, airborne fungi, temperature, relative humidity and carbon dioxide in total 69 general offices were $426({\pm}83)\;cfu/m^3$, $234({\pm}125)\;cfu/m^3$, $25.9({\pm}1.3)\;^{\circ}C$, $57.7({\pm}8.6)\;%$, $422({\pm}38)\;ppm$, respectively. The I/O ratio of airborne bacteria and fungi was over 1 and there was no significant difference among temperature, relative humidity and carbon dioxide in total 69 general offices. In construction period, a concentration of airborne bacteria and fungi was significantly highest in general offices constructed under one year and over three years since construction, respectively (p<0.05). The concentration of airborne fungi in general offices located at basement was significantly higher than those located at ground (p<0.05). No significant difference of airborne bacteria and fungi in general offices was found regardless of installation of HVAC system (p>0.05). The dominant bacterial genera identified in general offices was Staphylococcus, followed by Micrococcus, Bacillus, and Corynebacterium while usarium, Penicillium, Aspergillus, Alternaria, Rhizopus and Mucor were identified as dominant fungal genera in general offices.