• Title/Summary/Keyword: AirQ+

Search Result 297, Processing Time 0.023 seconds

A study of U.S. and European electronic hardware guidelines for aviation system : RTCA DO-254 and ECSS-Q-ST-60-02C (항공 시스템용 전자 하드웨어 개발을 위한 미국 및 유럽의 가이드라인 : RTCA DO-254와 ECSS-Q-ST-60-02C의 비교 분석 연구)

  • Kim, Sung Hoon;Kim, Hyun Woo;Chae, Hee Moon;Kim, Ki Du
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.4
    • /
    • pp.10-16
    • /
    • 2022
  • Since aviation systems are developed as the complex form of software a hardware, the necessity to apply to relevant guidelines is increasing. It is however uncommon that international development guidelines regarding electronic hardware are applied to current domestic aviation systems. In this paper, we compare and analyze DO-254 and ECSS-Q-ST-60-02C, electronic hardware development guidelines with the case of KASS (Korea Augmentation Satellite System) Performance Suitability, based on the project of SBAS (Satellite Based Augmentation System) development and construction.

The Effect of Flow Rate into Room by Natural Convection in Air Conditioner Duct (공조기 덕트 내의 자연대류가 실내 유입유량에 미치는 영향)

  • 공태우;정한식;정효민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.160-166
    • /
    • 2001
  • A numerical analysis has been performed for natural convection in an air conditioner duct system. The governing equations were solved a finite volume method using a SIMPLE algorithm. In the calculation mode of duct, the room temperature was preserved at $25.0^{\circ}C$ and duct wall temperature had a temperature of 15, 20.0, 22.5, 23.75, 26.25, 27.5 30 and $35^{\circ}C$. The results of velocity vectors and contours have been represented for various parameters. Based on the numerical data, the relationships between temperature difference and flow rate into room was represented. In the case of $T_\gamma>T_\omega$, the equation for temperature difference and flow rate was $Q=0.0285\triangleT^0.4005$, and in the case of $T_\gamma>T_\omega$, the equation was $Q=0.0099\triangleT^0.4752$. The duct system has an important relation to room temperature and duct wall temperature.

  • PDF

Prediction of Micro-Bubble Releasing Concentration with the Retention Time of a Micro-Bubble Generating Pump (미세기포 발생펌프 내 체류시간에 따른 미세기포의 발생 농도 예측)

  • Ambrosia, Matthew Stanley;Lee, Chang-Han
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.829-837
    • /
    • 2016
  • The mechanism of micro-bubble generation with a pump is not clarified yet, so the design of water treatment systems with a micro-bubble generating pump is based on trial and error methods. This study tried to explain clearly quantitative relationships of experimental micro-bubble concentration ($C_{air}$) of continuous operation tests with a micro-bubble generating pump and theoretical air solubility. Operation parameters for the tests were discharge pressure ($P_g$), water ($Q_{w0}$) and air ($q_0$) flow rates, orifice diameter ($D_o$), and retention time (t). The experimental micro-bubble concentrations ($C_{air}$) at 4.8 atm of discharge pressure ($P_g$) were in the range of 21.04 to 25.29 mL/L. When the retention time (t) by changing the pipe line length ($L_p$) increased from 1.22 to 6.77s, the experimental micro-bubble concentrations ($C_{air}$) increased from 25.86 to 30.78 mL air/L water linearly. The dissolved and dispersed micro-bubble concentrations ($C_{air}$) are approximately 4 times more than the theoretical air solubility.

Experimental Study on the Channel Type Heat Sink to Maintain Proper Temperature Cycle of Bio-Sample (바이오 시료의 적정온도 사이클 유지를 위한 채널형 히트싱크에 대한 실험적 연구)

  • Jeong-Gyu Hwang;Sang-Hee Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.1
    • /
    • pp.183-191
    • /
    • 2023
  • This study was conducted experimentally to investigate the surface temperature of the heat sink, the air temperature in the flow channel and the sample temperature by changing the channel number of channel type heat sink and the air flow rate when heating and cooling the bio sample. The target temperature of the sample was 15℃ or less as the minimum value and 82℃ or more as the maximum value. In this study, the channel number of the heat sink(N = 1, 2, 4, 5, 10) and the air flow rate(Q=25, 42, 54m3/min) were varied. The bio sample was replaced with water, and the volume of water is 4mL. The size of the heat sink is 80x73x150mm and the material is aluminum. When cooling the sample, the surface temperature, the air temperature and the sample temperature were highly dependent on the number of channels and the flow rate. However, when the sample is heated, the surface temperature, air temperature and sample temperature do not depend on the number of channels and the flow rate. It was found that the conditions for satisfying the minimum temperature of 15℃ or less when cooling the sample were the number of channels N≥5 and the flow rate Q≥42m3/min. When heating the sample, the conditions to satisfy the maximum temperature of 82℃ or more are the number of channels N≤5 and the air flow rate Q≤42m3/min.

A Model for Predicting the Effect of Increasing Air Temperature on the Net Photosynthetic Rate of Quercus mongolica Stands

  • Ihm, Byung-Sun;Lee, Jeom-Sook;Kim, Jong-Wook;Kim, Joon-Ho
    • Journal of Ecology and Environment
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • A model was developed to predict the effects of rising air temperature on net photosynthetic rate of Quercus mongolica stands at Mt. Paekcheok-san, Kangwon-do in South Korea. The PFD (Photon flux density) and air temperature were determined from weather data from the research site and the Daegwallyeong meteorological station and gas exchange or release responses of each tree component were measured. Using these data, we simulated the effects of increases in mean annual air temperatures above current conditions on annual $CO_2$ budget of Q. mongolica stands. If mean annual air temperature is increased by 0.5, 1.0, 1.5, 2.0, 2.5 or $3.0^{\circ}C$, annual net photosynthetic rate will be increased by 8.8, 12.8, 14.5, 12.6, 9.2 and 1.0 ton $CO_2\;ha^{-1}yr^{-1}$ respectively. Simulations indicate that changes in air temperature will have a major impact on gas exchange and release in Q. mongolica stands, resulting in a net increase in the rate of carbon fixation by standing crops.

Development of High-Quality LTCC Solenoid Inductor using Solder ball and Air Cavity for 3-D SiP

  • Bae, Hyun-Cheol;Choi, Kwang-Seong;Eom, Yong-Sung;Kim, Sung-Chan;Lee, Jong-Hyun;Moon, Jong-Tae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.4
    • /
    • pp.5-8
    • /
    • 2009
  • In this paper, a high-quality low-temperature co-fired ceramic (LTCC) solenoid inductor using a solder ball and an air cavity on a silicon wafer for three-dimensional (3-D) system-in-package (SiP) is proposed. The LTCC multi-layer solenoid inductor is attached using Ag paste and solder ball on a silicon wafer with the air cavity structure. The air cavity is formed on a silicon wafer through an anisotropic wet-etching technology and is able to isolate the LTCC dielectric loss which is equivalent to a low k material effect. The electrical coupling between the metal layer and the LTCC dielectric layer is decreased by adopting the air cavity. The LTCC solenoid inductor using the solder ball and the air cavity on silicon wafer has an improved Q factor and self-resonant frequency (SRF) by reducing the LTCC dielectric resistance and parasitic capacitance. Also, 3-D device stacking technologies provide an effective path to the miniaturization of electronic systems.

  • PDF

PD Detection in Air by Capacitive Electric Field Sensor (전계센서의 원리를 이용한 공기중 부분방전신호 검출)

  • Lee, Y.H.;Lee, K.W.;Park, S.H.;Kang, S.H.;Shin, Y.S.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.900-903
    • /
    • 2002
  • Partial discharges(PD) in air, corona discharges, deteriorate the insulation strength. So, it is necessary to detect PD at an early stage before the system failure and extensive damage to the equipment. PD emit signals which can be detected by applying an capacitive electric field diagnosis. In this paper, We measured signals by capacitive electric field sensor and analyzed FFT from PD, and then compared conventional electric PD detecting method to capacitive electric field diagnosis by $\Psi-q-n$, $\Psi-v-n$, $\Psi-n$, $\Psi-q$ distributions.

  • PDF

Comparison of Pigment Content and Photosynthetic Capacity of Quercus mongolica Stands at Namsan, Seoul and Paekcheoksan, Kangwondo (서울 남산과 강원도 백적산의 신갈나무 숲에서 엽록소 함량 및 광합성능의 비교)

  • 임병선;김종욱;이규송;이점숙;김준호;이창석
    • The Korean Journal of Ecology
    • /
    • v.26 no.5
    • /
    • pp.267-271
    • /
    • 2003
  • To elucidate effects of air pollutants on ecophysiological properties of two Quercus mongolica stands at different levels of air pollution, photosynthetic capacity and chloroplast pigment were measured in leaves of Q. mongolica. Photosynthetic capacity, photosynthetic pigment content and SLA (specific leaf area) of Q. mongolica leaves in polluted area were lower than those in nonpolluted area. Also, the chlorosis and mottling in some of leaves were observed in polluted area after August. Except for total carotenoid (P<0.05) the correlations between photosynthetic capacity and pigment content were not significant. Photosynthetic capacity of Q. mongolica leaves in polluted area was decreased after July.

Implementation of High-Q Bondwire Inductors on Silicon RFIC (RFIC를 위한 실리콘 기판에서의 고품질 본드와이어 인덕터 구현)

  • 최근영;송병욱;김성진;이해영
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.12
    • /
    • pp.559-565
    • /
    • 2002
  • Today, because a quality factor of the inductor fabricated on silicon substrate for RFIC is under 12, the realization of inductor haying high-Q is essential. In this paper, two inductors having improved Q-factor are proposed and fabricated using a bondwire on silicon substrate. Also for the PGS is applied to the same inductors, four inductors are fabricated finally The bondwire Inductors have the relatively low conductor loss due to wide cross-section area and they can reduce the parastic capacitance very much because they are located in the air. Simulation and measurement results show that the proposed inductors have much more improved Q-factor, 15, than a conventional spiral inductor at 1.5 GHz. Because of the use of an automatic bonding machine, we can fabricate the high - Q inductors very easily, repeatedly.

The Effect on the Plant Community Decline by the Air Pollutant & Acid Rain in the Metropolitan Area (대기오염 및 산성비가 서울지역 식물군집에 미치는 영향)

  • 유창희;이경재
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.20 no.1
    • /
    • pp.80-94
    • /
    • 1992
  • To inspect the changing of the forest soil and plants community structrure by air plooutand & acid rain during from September to November in 1990, the smapling sites were selected in the Piwon, Namsan and Kwangnung forest. In sites, plots were set up in Q. aliena forest at Piwon, Quercus mongolica and Pinus densiflora forest at Namsan and Q. mongolica and Pinus densiflora forest at Kwangnung. To obtain the individual number of trees, number of species, importance values and species diversity, using the Curtis & McIntosh methods. The results are following that; 1) In Pinus densiflora community, it was almost dominated by Q. spp. in the canopy layer and P. densiflora and Carpinus laxiflora through the subtree to shrub layer at Kwangnung. It wassaid that C. laxiflora is the climax species in moddle temperature zone. On the contrary, in Namsan forest, there is no appearance thesamplings of P. densiflora & C. laxiflora, but Styrax japonica and Stephanandra incisa that are acid-tolerance species are dominant ones. On the other hand, in Q. spp. community, Q. spp. and C. laxiflora are dominant ones. On the other hand, in Q. spp. community, Q. spp. and C. laxiflora are dominant species through all layer, and in addition C. cordata somewhat appear at Kwangnung. But at Namsan and Piwon forest, Q. mongolica & Q. aliena that were dominant species in canopy layer disappeared in the subtreeand shrub layer, and C. laxiflora and Corunus cordata absolutely disappeared. It were similarly dominated by Robinia pseudo-acacia, Styrax japonica, Sorbus alnifolia, Acer pseudo-sieboldianum, Rhododendrn mucronulatum and so on at Namsn and Piwon forest. In the light of these facts, it found out that disclimax was similar between Namsan and Piwon forest. 2) Species diversity and maximum species diversity were decreased in Kwangnumg, Namsan, Piwon in order. It was xpected that vegetational community was affected by environmental pollutant. 3) As the vegetational community structure analyses, using DCA technique among the ordination, ecological successional series are stopped to Q. spp. from P. densiflora at Namsan and Piwon, but that of Kwangnung is on the way that P. densiflora, Q. alena, C. laxiflora. It was obvi ously different from Namsan and Piwon. 4) In Q. spp. & P. densiflora community, the number of woody plants inNamsan & Piwon is much less than that of Kwangnung through all Layer. Especially, Piwon shown very severe difference. Through all community, the number of individuals of Piwon and Namsan are less than that of Kwangnung. Specially, that of the shrub layer is obvious. 5) In the growth rate of trees, it found out that all sites showed the growth decline phenomena. Especially, since in 1975, there have been the micro disclimax phenomena in Q. community of Kwangnung. 6) In the Q. community, soil acidity of Namsan & Piwon measured 4.57, 4.40 respectively. It was very strong acidity and far lower than that of Kwangnung. Also the content amount of Mg++ in Namsan & Piwon forest were still lower than Kwangnung.

  • PDF