• 제목/요약/키워드: Air-tightness test

검색결과 31건 처리시간 0.025초

광섬유 케이블 접속함체의 사출성형 특성 분석 (Characteristics of Injection Molding in Optical Fiber Splice Closure)

  • 최재영;홍민성
    • 한국생산제조학회지
    • /
    • 제25권6호
    • /
    • pp.434-439
    • /
    • 2016
  • Optical fiber splice closure serves to protect connection parts from external environment. Moreover, it functions as a connection, junction, and distribution in diverse surroundings such as aerial, underground, duct, and pole. In this research, first, the optical fiber splice closure, its configuration, and the design problem were briefly investigated. Second, the design and application for in-line cable closure were studied to satisfy its construction and technical features. The injection molding conditions and optimal design were conducted to save time and cost during the manufacturing process. Third, methods to minimize loss via of optical fiber cable while strongly fixing optical fiber cable with optical cable holder to prevent fracture were researched, and tests such as perfect air tightness and mechanical and environmental performance were conducted.

터보펌프 케이징의 구조해석 및 측정 (Structural Analysis and Measurement of Turbopump Casings)

  • 윤석환;전성민;김진한
    • 항공우주기술
    • /
    • 제5권2호
    • /
    • pp.174-180
    • /
    • 2006
  • 액체로켓엔진에서 연료와 산화제를 가압하는 역할을 하는 핵심부품인 터보펌프는 극저온 산화제와 구동 터빈의 고온 환경이 동일 축에 분포하고 있으며 내부 회전부 간극이 매우 작고 회전속도가 높아 기계적으로 대단히 열악한 환경에서 동작한다. 따라서 사고 위험도를 낮추기 위한 구조 해석 및 시험이 필수적인데, 본 연구에서는 특히 터보펌프 케이징의 구조해석 및 응력 측정이 이루어졌다. 기존의 단품 레벨에서의 해석에서 벗어나 연료펌프와 산화제펌프의 케이징 조립체 레벨에서 내압기밀시험 조건에 대한 구조해석이 이루어졌으며 이를 통하여 케이징 간 체결효과 및 실 부분의 접촉 압력을 성공적으로 고려할 수 있었다. 또한, 연료펌프 케이징에 나타나는 높은 수준의 응력 집중 현상을 해석과 측정을 병행함으로써 성공적으로 예측하였다.

  • PDF

Evaluation of the Residual Performance of Partially Charred Components of Old Wooden Structure I - Use of Ultrasonic Velocity and Testing of the Drilling Resistance -

  • Lee, Hyun-Mi;Hwang, Won-Joung;Lee, Dong-Heub;Kim, Hong Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권2호
    • /
    • pp.193-206
    • /
    • 2014
  • Residual performance of old architectural wood which has been damaged was measured using Nondestructive Evaluation (NDE). The wood Pole Tester was used to assess ultrasonic velocity inside wood and drill resistance was determined using an IML-resistograph. For ultrasonic measurements squared timber and circular timber's measurements were separately conducted with 1,300 m/s as the standard ultrasonic velocity. The standard wood samples divided into two parts; a non-sound area (below the standard), and a sound area (above the standard). Furthermore, schematization of wood was compared with results naked eye observation. The drilling resistance test was performed for both length and thickness direction in wood. The internal of the drilling was set at 30 cm (length direction), 5 cm (width direction) and 30cm (thickness direction). A non-sound area was defined as that 1) amplitude is below 20% and 2) carbonization and deterioration are related.

방출셀을 이용한 액상건축자재 오염물질 방출시험방법 정립에 관한 연구 (Study on establishment of emission cell test method for liquid phase building materials)

  • 임정연;장성기;서수연
    • 분석과학
    • /
    • 제22권3호
    • /
    • pp.191-200
    • /
    • 2009
  • 이 연구는 소형방출챔버와 방출셀을 이용한 총휘발성유기화합물(TVOC) 방출시험결과의 상관성을 규명하여 방출셀을 이용한 액상 건축자재 오염물질 방출시험 방법을 정립하고 활용방안을 제시하기 위한 기초 자료를 확보하고자 수행되었다. 소형방출챔버와 방출셀을 이용한 액상 건축자재 방출시험을 실시하기 위해 방출시험 적합성 여부를 판단하고 최적조건을 확립하기 위하여 방출시험장치, 분석기기에 대한 성능평가를 실시하였다. 방출시험 장치인 소형방출챔버와 방출셀의 배경농도 청정도, 기밀도, 회수율, 분석장치인 열탈착장치 회수율 및 GC/MS 기기재현성, 방법검출한계(MDL) 등을 평가한 결과 방출시험장치와 분석기기의 조건은 안정적이고 재현성과 감도가 양호하여 액상 건축자재에서 방출되는 오염물질에 대한 측정 분석조건이 최적화되었음을 확인할 수 있었다. 페인트, 접착제, 실란트로 구성된 40개의 액상 건축자재를 대상으로 소형방출챔버와 방출셀을 이용하여 오염물질 방출시험을 실시한 결과 방출되는 총휘발성유기화합물의 농도는 소형 방출챔버와 방출셀에서 모두 대수정규분포(log normal distribution)하였으며 시험방법차이에 따른 방출량 분포의 차이는 크지 않았다. 또한 방출셀을 이용하여 오염물질 방출시험을 실시하였을 때, 소형방출챔버를 이용하였을 때보다 약 1.35~1.41배 높은 방출량을 나타내었으며 상관계수(r)가 약 0.91~0.97의 범위를 보여 높은 상관성이 있는 것으로 확인되었다.

고속철도차량 갱웨이 벨로우즈의 비선형 해석 (Nonlinear Analysis of Rubber Bellows for the High Speed Railway Vehicle)

  • 강길현;김철수
    • 한국산학기술학회논문지
    • /
    • 제14권8호
    • /
    • pp.3631-3637
    • /
    • 2013
  • 갱웨이 벨로우즈는 관절형 고속철도차량 객차 끝단부 사이에 다양한 변위차를 고려하여 갱웨이 프레임에 장착된 이중 주름구조 네오프렌 고무부품이다. 실제 운행중의 벨로우즈의 파손은 터널 통과시 기밀 파손으로 인한 이명현상 발생과 함께 소음 증가로 승객의 승차감에 심각한 영향을 미친다. 본 연구에서는 고속철도차량 갱웨이 벨로우즈의 안전성 연구일환으로서, 차량주행시 차량 끝단부의 3축 회전변위(롤링, 요잉, 피칭변위차)를 고려한 갱웨이 벨로우즈의 비선형 해석을 수행하였다. 본 고무의 비선형 재료 특성은 단축인장 및 등2축 인장시험을 수행하여 구하였다. 또한, 비선형 해석결과로부터 회전변위 및 마찰계수의 영향을 평가하였다.

MRT(Moisture Responded Transformable)섬유의 의료용 압박소매 적용에 관한 연구 (A Study on the Application of Medical Compression Arm Sleeves Using a MRT(Moisture Responded Transformable) Fibers)

  • 조대현;정태두;박은희;박영미
    • 한국염색가공학회지
    • /
    • 제33권2호
    • /
    • pp.87-95
    • /
    • 2021
  • In this study, the application of a medical compression sleeve of Moisture Responded Transformable(MRT) fibers to the treatment of lymphedema after surgery in breast cancer patients was investigated. MRT fibers were manufactured with PET and Nylon6 bi-component cross-section yarns, and compression sleeves of sleeves 1, 2, 3, and 4 were knitted in order of size, and then the physical properties and clinical tests were evaluated. As a result, the pressure of compression sleeve in wrinkle was the lowest in sleeve 1 with 3.81 kPa, and the highest in sleeve 4 with 5.22 kPa. Elastic recovery rate is that all parts except the top of the sleeve 1 exhibited 100%. The air permeability was good at 12.1 ~ 16.1 cm3/cm2/sec, and peeling was also comparatively excellent as grade 3. In addition, the weight of the compression sleeves 1, 2, and 3 decreased as 18.3 ~ 23.0 g/m2 depend on size, while the compared sample was heavier with 17.39 ~ 32.61 g/m2. In lymphoscintigraphy test, it was confirmed that the function of remaining lymph node was good in all patients. Although there were no differences between samples in skin irritation and tightness in wearing comfort, the manufactured sleeves showed better fit, lightness, fashion and breathability than the comparable sleeves.

건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선 (Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants)

  • 신우진;이철원;김만구
    • 분석과학
    • /
    • 제20권4호
    • /
    • pp.261-267
    • /
    • 2007
  • 건축자재에서 방출되는 오염물질을 평가하는 20 L 시험챔버법은 챔버 내부에 노출되는 시료의 표면방출만을 측정한다. 일정한 크기로 절단한 시편을 알루미늄 호일로 감싼 후 시편홀더에 고정시켜 20 L 시험챔버 내에 위치시킨 후 방출시험을 실시한다. 이때 시편홀더의 기밀성이 보장되지 못한다면 시료절단면에서 방출되는 오염물질로 인하여 정확한 평가가 이루어질 수 없다. 이러한 절단면의 영향은 표면처리를 하여 표면에서 보다 절단면에서 더 많은 오염물질이 방출되는 판상재(합판, 장판) 시료의 경우 더 크다. 이 연구에서는 바닥재로 사용되는 장판을 대상으로 20 L 시험챔버와 1 L 시험챔버의 방출시험결과를 비교하여 시편홀더의 기밀성을 확인하였다. 또한 가구재로 사용되는 LPM 양면처리한 MDF를 대상으로 현행의 시험방법과 시료절단면을 VOC 저방출 tape으로 밀봉한 방법을 비교하여 시편홀더의 부족한 기밀성의 개선이 가능하지 확인하였다. LPM 양면처리한 MDF의 7일 경과 후 방출강도는 TVOC의 경우 Tape 사용 유무에 따라 각각 $0.009mg/m^2h$, $0.003mg/m^2h$로 기밀성을 보완할 수 있었다. 또한 n=3에서 상대표준편차가 현행의 방법은 $0.004mg/m^2h$, tape을 사용했을 경우 $0.002mg/m^2h$로 현행 방법의 시험편홀더 기밀성 부족으로 인한 절단면의 불균일한 영향을 VOC 저방출테이프 사용으로 배제할 수 있었다.

조습제(燥濕濟)(Art-Sorb)를 이용한 벽부형진열장(壁附形陳列欌) 밀폐도(密閉度) 간접측정(間接測淀) (Air-tightness Test by Silicagel on Museum Cases)

  • 유혜선;김명남;이승은
    • 박물관보존과학
    • /
    • 제3권
    • /
    • pp.71-78
    • /
    • 2001
  • 박물관 진열장의 기밀성은 일반적으로 CO2 추적가스를 이용한 밀폐도를 측정함으로서 조사되어 왔지만 진열장 내부에 구멍을 내야하는 점은 사용전이나 사용 중인 진열장에 대한 밀폐도 측정에 적용하는데 문제점으로 지적되어 왔다. 이에 진열장의 형상을 변화시키지 않고, 진열장의 밀폐도를 간접측정함으로서 사용전이나 필요에 따라서는 전시중인 진열장에 대한 밀폐도를 측정할 수 있는 대안을 제시하고자 하였다. 밀폐도는 간접측정법은 진열장 내부의 온습도변화와 습도조절제(Art-sorb)의 중량변화를 통해 진열장의 기밀도를 간접적으로 알아보는 방법이다. 실험은 동일장소에 시공된 3개의 벽부형진열장을 대상으로 진열장내 조명을 켜지 않고 Art-sorb와 온습도 수집기를 넣고 12일간 진행하였다. 각 진열장내 온도와 습도 변동분을 주변변동분으로 나눠 변동율로 나타냈으며, 그 결과 온도 변동율에서는 벽부장A(0.67)가 벽부장B(0.69)나 벽부장C(0.79)보다 변동율이 적었으며 습도 변동율에서도 벽부장A(0.12)가 벽부장B(0.19)나 벽부장C(0.72)보다 변동율이 적어 기밀도가 가장 양호함을 알 수 있었다. 또한 CO2추적가스를 이용한 직접 밀폐도 측정에서의 공기교환율에 대하여 간접 밀폐도 측정에서의 습도변동율을 대입해 보았다.

나노합성 무기질 폴리머계 표면처리제가 콘크리트의 내구성에 미치는 영향 (The Influence of Nano Synthesized Polymer Paint on Durability of Concrete)

  • 백종명;박용걸
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.56-63
    • /
    • 2016
  • 콘크리트 구조물의 내구성을 향상하기 위해 개발된 통기성이 개선된 나노합성 폴리머 표면처리제를 도포한 콘크리트의 내구성향상 효과를 평가하기 위해 내부 구조와 공극량을 측정하였으며, 염분침투, 탄산화, 동결융해 및 화학적 침식 저항성에 대한 실험을 진행하여 기존 표면처리제와 비교 분석하였다. 공극량과 내부 구조를 측정한 결과, 나노합성 폴리머 표면처리제를 도포한 콘크리트는 $0.3{\mu}m$ 이상의 공극과 $0.1{\mu}m$ 이하의 공극영역에서 세공량이 감소하는 경향을 보였으며, 전자현미경을 통한 촬영된 내부는 수화조직에 의해 치밀함을 보였다. 나노합성 폴리머 표면처리제를 도포한 콘크리트의 염분침투 깊이는 무도포 콘크리트에 비해 약 92% 이상, 수성 에폭시 표면처리제를 도포한 콘크리트보다도 약 70% 이상 감소하였다. 이는 탄산화, 동결융해 및 화학적 침식 저항성 실험에서도 비슷하게 나타났다. 특히 황산 5% 수용액에 침지 실험한 화학적 침식 저항성 실험에서는 침지 12일 이후 무도포 콘크리트와 수성 에폭시 표면처리제를 도포한 콘크리트에서 -4%의 중량감소를 보였지만, 나노합성 폴리머 표면처리제를 도포한 콘크리트는 -1.7%의 중량감소율을 보였으며, Tsivilis et al.에 의한 외관등급 조사법에서도 우수한 결과를 보였다.

소형 벤로형 유리온실에서 적외선등 난방 시스템의 난방효과 분석 (Analysis of Heating Effect of an Infrared Heating System in a Small Venlo-type Glasshouse)

  • 임미영;고충호;이상복;김효경;배용한;김영복;윤용철;정병룡
    • 화훼연구
    • /
    • 제18권3호
    • /
    • pp.186-192
    • /
    • 2010
  • 경상대학교 농장 벤로형 유리온실($280m^2$)에 적외선등 난방 시스템을 설치하였다. 분식물 호접난, 홍콩야자나무, 무늬고무나무, 장미에 대한 적외선등 난방 시스템의 가열효과를 알아보고자 열화상 카메라를 이용하여 온도변화를 측정하였다. 그리고 난방의 효과를 적외선등 난방시스템 'On'과 'Off'로 달리하여 실험을 수행하였고 적외선등 난방 시스템의 경제성을 분석하였다. 온실 내부 설정온도가 $18^{\circ}C$일 때 식물체의 엽온도는 $22.8{\sim}27^{\circ}C$, 화분에 담겨 있는 배지의 온도는 $21.3{\sim}24.3^{\circ}C$이었다. 관엽식물과 같이 키가 큰 작물은 상부의 온도가 홍콩야자나무와 무늬고무나무 각각 $24.0^{\circ}C$$26.9^{\circ}C$로 가장 높았고, 아래 로 내려오면서 점점 온도가 내려가는 경향을 보였다. 열화상 카메라를 이용한 온도 변화 관찰을 통하여 적외선등 난방 시스템을 이용한 온실내 작물의 가열 효과는 충분함을 알 수 있었다. 장미의 경우 적외선등 난방 시스템을 이용한 난방의 경우 밤과 새벽 사이 외부 기온이 많이 떨어지는 시점에도 설정온도($18^{\circ}C$)에 가깝게 유지되고 있었다. 특히 'On' 상태에서 근권부 평균온도는 $21.8^{\circ}C$이었고, 엽의 평균온도는 $17.8^{\circ}C$이었다. 'Off' 상태의 경우 근권부 평균온도가 $20.4^{\circ}C$이었고, 엽의 평균온도는 $15.5^{\circ}C$로 뚜렷한 차이를 보였다. 난방부하량은 약 $24,850{\sim}35,830kcal{\cdot}h^{-1}$ 정도로서 이 때 난방비를 경유로 환산 하면 약 27,000~40,000원 정도였다. 소비전력량과 전력요금은 각각 330~560 kWh 및 8,600~14,800원 정도였다. 즉 전체적으로 단순비교해 볼 때, 적외선등 난방 시스템을 사용할 경우 경유 온수보일러에 비해 난방비용이 약 35%정도 밖에 소요되지 않는 것을 알 수 있다. 적외선등 난방시스템을 이용한 난방의 경우 야간 시간대에 공기온도가 설정온도 보다는 다소 낮게 유지되고 있음을 알 수 있다. 즉, 유리온실의 경우 밀폐성이 좋지 않아서 공기온도를 설정한 온도수준으로 유지되지 못하는 것으로 판단되어 향후 유리온실에서 적외선등 난방 시스템을 이용하는 경우 설치간격, 센서 부착위치 및 공기대류 등에 대한 연구가 더 필요하다고 생각된다.