• Title/Summary/Keyword: Air-tightness

Search Result 119, Processing Time 0.024 seconds

A Study on the Application of Medical Compression Arm Sleeves Using a MRT(Moisture Responded Transformable) Fibers (MRT(Moisture Responded Transformable)섬유의 의료용 압박소매 적용에 관한 연구)

  • Cho, Daehyun;Jung, Taedu;Park, Eunhee;Park, Youngmi
    • Textile Coloration and Finishing
    • /
    • v.33 no.2
    • /
    • pp.87-95
    • /
    • 2021
  • In this study, the application of a medical compression sleeve of Moisture Responded Transformable(MRT) fibers to the treatment of lymphedema after surgery in breast cancer patients was investigated. MRT fibers were manufactured with PET and Nylon6 bi-component cross-section yarns, and compression sleeves of sleeves 1, 2, 3, and 4 were knitted in order of size, and then the physical properties and clinical tests were evaluated. As a result, the pressure of compression sleeve in wrinkle was the lowest in sleeve 1 with 3.81 kPa, and the highest in sleeve 4 with 5.22 kPa. Elastic recovery rate is that all parts except the top of the sleeve 1 exhibited 100%. The air permeability was good at 12.1 ~ 16.1 cm3/cm2/sec, and peeling was also comparatively excellent as grade 3. In addition, the weight of the compression sleeves 1, 2, and 3 decreased as 18.3 ~ 23.0 g/m2 depend on size, while the compared sample was heavier with 17.39 ~ 32.61 g/m2. In lymphoscintigraphy test, it was confirmed that the function of remaining lymph node was good in all patients. Although there were no differences between samples in skin irritation and tightness in wearing comfort, the manufactured sleeves showed better fit, lightness, fashion and breathability than the comparable sleeves.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

Sick Building Syndrome in 130 Underground Workers (지하상가 근무자의 건강 장애에 관한 실태조사)

  • Joo, Ree;SaKong, Joon;Chung, Jong-Hak;Park, Sang-Whan;Kim, Dong-Hee;Kim, Dong-Min;Choi, Eun-Kyong;Cho, Hyun-Geon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.325-340
    • /
    • 1998
  • A cross-sectional study was conducted to evaluate the relationship between sick building syndrome(SBS) and the environmental factors affecting SBS on 130 underground workers and 60 controls. The study consisted of 1) a review of environmental condition 2) measurement of temperature, $O_2$, $CO_2$, CO, and formaldehyde and 3) a questionnaire survey of symptom prevalence and perception of environmental conditions using indoor Air Quality questionnaire recommended by National Institute for Occupational Safety and Health. Bronchitis and dust allergy were more prevalent in underground workers significantly(p < 0.05). Among the 18 symptoms related to the indoor air pollution, the experience rate of dry, itching or irritated eyes, sore or dry throat, chest tightness, tired or strained eyes and dry or itchy skin symptom was significantly different between the underground workers and controls. The diagnostic criteria of SBS was defined as at least 1 symptom is experienced 1-3 times a week during the last 1 month among 18 indoor air pollution related symptoms which can be relieved by moving out of the underground. Applying the criteria, the mean symptom score was significant higher in underground workers than controls significantly (p < 0.05). These resalts indicated that underground workers are under inappropriate ergonomic and physical condition and inadequate ventilation. Their experience rate of symptoms related to indoor air pollution and prevalence of SBS was significantly higher than controls. To reduce the prevalence of SBS of underground workers, the surveillance system of indoor air quality, restriction of using fuel in underground and legislative regulations for the environment are needed to establish a better indoor air quality. Early detection, treatment and prevention of SBS through medical attention is also needed.

  • PDF

Air-tightness Test by Silicagel on Museum Cases (조습제(燥濕濟)(Art-Sorb)를 이용한 벽부형진열장(壁附形陳列欌) 밀폐도(密閉度) 간접측정(間接測淀))

  • Yu, Hei-sun;Kim, Myoung-nam;Lee, Sung-eun
    • Conservation Science in Museum
    • /
    • v.3
    • /
    • pp.71-78
    • /
    • 2001
  • The airtightness of museum cases in museums was measured by using CO2 tracing gas, but it has been pointed that it has a problem with measuring the airtightness of a museum case which has a hole inside before it is used or while is being used. So studies tried to come up with alternatives which make it possible to measure the airtightness of a museum case before it is used or while it is being used if necessary by indirectly measuring the airtightness of the museum case without changing its form. Indirect measuring is done by measuring the change of Art-sorb weight and the change of temperature and humidity inside the museum case. Experiments were made for 12 days with three builtin wall case installed at the same place without turning on the lights but with Art-sorb and the data logger of temperature and humidity put into museum case. The change rate was produced with the change of temperature and humidity inside the museum case divided by that of those around museum case. As a result, the temperature change rate of museum case A(0.67) was lower than that of museum case B(0.69) or museum case C(0.79). The humidity change rate of museum case A(0.12) was lower than that of museum case B(0.19) or museum case C(0.72) showing that its airtightness was the best. Also in the direct airtightness measurement by CO2 tracing gas, the air exchange rate was compared with the humidity change rate by Art-sorb in the indirect measurement.

Analysis of Heating Effect of an Infrared Heating System in a Small Venlo-type Glasshouse (소형 벤로형 유리온실에서 적외선등 난방 시스템의 난방효과 분석)

  • Lim, Mi Young;Ko, Chung Ho;Lee, Sang Bok;Kim, Hyo Kyeong;Bae, Yong Han;Kim, Young Bok;Yoon, Yong Cheol;Jeong, Byoung Ryong
    • FLOWER RESEARCH JOURNAL
    • /
    • v.18 no.3
    • /
    • pp.186-192
    • /
    • 2010
  • An infrared heating system, installed in a small venlo-type glasshouse ($280m^2$) in Gyeongsang National University, Jinju, Korea, was used to investigate its heating effect with potted Phalaenopsis, Schefflera arboricola 'Hongkong', Ficus elastica 'Variegata', and Rosa hybrida 'Yellow King' as the test plants. Temperature changes in test plants with the system turned 'On' and 'Off' were measured by using an infrared camera and the consumption of electricity by this infrared heating system was measured and analyzed. In potted Phalaenopsis, when the set air temperature of the greenhouse was $18^{\circ}C$, temperature of leaves and the growing medium were $22.8{\sim}27^{\circ}C$ and $21.3{\sim}24.3^{\circ}C$, respectively. In such tall plants as Schefflera arboricola 'Hongkong' and Ficus elastica 'Variegata', the upper part showed the highest temperature of 24.0 and $26.9^{\circ}C$, respectively. From the results of temperature change measurements, the plant temperatures were near or above the set point temperatures with some fluctuations depending on the position or distance from the infrared heating system. When air temperature between night and dawn dropped sharply, plant temperatures were maintained close to the set temperature ($18^{\circ}C$). There was a significant difference between 'On' and 'Off' states of the infrared heating system in average temperatures of root zone and leaf: 21.8 and $17.8^{\circ}C$ with the system 'On' and 20.4 and $15.5^{\circ}C$ with the system 'Off', respectively, in a cut rose Rosa hybrida 'Yellow King'. The heating load was about $24,850{\sim}35,830kcal{\cdot}h^{-1}$, which comes to about 27,000~40,000 won in Korean currency when calculated in terms of the cost of heating by a hot water heating system heated by petroleum. The cost for heating by the infrared heating system was about 35% of that of a hot water heating system. With the infrared heating system, the air temperature during the night was maintained slightly lower than the set point air temperature, probably due to the lack of air tightness of the glasshouse. Therefore, glasshouses with an infrared heating system requires further investigation including the installation space of the heat-emitting units, temperature sensor positions, and convection.

The Influence of Nano Synthesized Polymer Paint on Durability of Concrete (나노합성 무기질 폴리머계 표면처리제가 콘크리트의 내구성에 미치는 영향)

  • Beak, Jong-Myeong;Park, Youg-Keol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.56-63
    • /
    • 2016
  • This experiment was compared and analyzed between the original surface paint through chloride penetration, neutralization, freeze-thaw and chemical corrosion resistance measuring internal structure and volume of voids in order to evaluate the effect of increase in durability of the newly modeled nano synthesized polymer paint painted on concrete surface which results improvement on air permeability to increase the durability of concrete structures. The test result of measuring volume of void and inner structure, concrete, spreaded with nano synthesized polymer paint, showed decreasing trend of pore volume in the range of less than $0.1{\mu}m$ and more than $0.3{\mu}m$. Also, using an electron microscope inside showed tightness of hydration texture. Chloride penetration depth of concrete, painted with nano synthesized polymer paint, was decreased more than 92% compared to non-painted concrete and 70% with water-based epoxy painted concrete. Especially, chemical corrosion resistance test set with aqueous solution of 5% sulfuric acid, non-painted concrete and water-based epoxy painted concrete showed weight loss of 4% after dipping for 12 days. On the other hand, concrete painted with nano synthesized polymer paint showed 1.7% weight loss under the same condition. Also, it showed great result of appearance under the criteria of Tsivilis et al.

Effects of Ondol Sleep Environment on the Thermo-physiological Response of the Human Body (온돌 수면환경이 인체의 온열생리반응에 미치는 영향)

  • Kim, Jung-Sook;Sung, Su-Kwang
    • Fashion & Textile Research Journal
    • /
    • v.1 no.2
    • /
    • pp.173-181
    • /
    • 1999
  • The purpose of this study was to investigate actual sleeping environments in Ondol rooms depending on the season. The experiment was performed on five healthy women. The bedroom environments using Ondol were measured in five cases (three apartments and two houses). The environments in bedroom, bedding temperature, skin temperature and thermal sensation were measured continuously through the seven days for each season in real life. This data of sleeping environments were analyzed in the view of seasonal variations and housing types. Annual average bedroom temperatures: $26.2{\sim}31.0^{\circ}C$ in apartments, $15.7{\sim}33.6^{\circ}C$ in houses. Annual average bedroom humidity: 48.3~82.1% RH in apartments, 64.9~87.0% RH in houses. During sleeping, temperatures of contact surfaces like sheets and under quilts ranged between $30.5^{\circ}C$ and $34.1^{\circ}C$ regardless of season or housing type. Annual average rectal temperature was $36.8^{\circ}C$ with no significant difference in season or housing type. In the point of thermal sensation, neutral temperature of the bedroom was $25.9^{\circ}C$ in apartments and $20.3^{\circ}C$ in houses. It was concluded that in spite of thermal environmental variations according to the seasons, skin, bedding and bedroom temperatures in apartments were better and more stable than those of houses. It is regarded that while houses are brick structured, apartments are steel-frame structured. Due to better insulation and air tightness, apartments were affected less from outdoor temperature and maintained higher room temperature than houses.

  • PDF

Development of Door Control Unit for the Electric Plug-in Door of Subway Train (전동차 전기식 플러그도어 출입문 제어 장치 개발)

  • Joung, Eui-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.47-53
    • /
    • 2011
  • The Electric Multiple Unit (EMU) has many types of door system such as sliding door, plug door etc.al. according to customer's requirements. The sliding door is widely used in Korea but has weak point in the noise problem. In the low operation speed, the noise coming from outer side of the EMU is not an important factor. As the speed is higher than before, noise is increased and make a problem. The main cause of noise is the imperfect air tightness in the EMU. The plug door system has advantages for the noise reduction characteristic in the high speed area. We have been developing electric plug-in door. The door is controlled by Door Control Unit(DCU) following the order of Automatic Train Protection (ATP) that is a kind of train signalling system. DCU has to simultaneously open and close the doors and the operation of it is related to the passengers safety. So DCU is a safety device that is important to reliability and safety. DCU is composed of several devices of control, motor driving, Input/Output, communication and power. In this paper, we will describe the functions, characteristic, requirement, subsystem and test results of DCU used for the electric plug-in door.

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.