• Title/Summary/Keyword: Air-tight

Search Result 91, Processing Time 0.028 seconds

Flexible and Lined Segment Tunnel for Underground Compressed Air Energy Storage(CAES) (복공식 압축공기 지하저장을 위한 가변성 분할 라이닝 터널기술)

  • Kim, Hyung-Mok;Rryu, Dong-Woo;Chung, So-Keul;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.19 no.2
    • /
    • pp.77-85
    • /
    • 2009
  • Flexible and lined segment air-tight tunnelling technology for Compressed Air Energy Storage-Gas Turbine(CAES-G/T) power generation was introduced. The distinguished characteristics of the air-tight tunnel system can be summarized by two facts. One is that the high inner pressure due to compressed air is sustained by surrounding rock mass with allowing sufficient displacement of lining segment. The other is that the air-tightness of storage tunnel was enhanced by adopting a specially designed rubber sheet. The flexible lined air-tight underground tunnel can be constructed at a comparatively shallow depth and near urban area so that the locally distributed CAES-G/T power generation can be accomplished. In addition, this air-tight tunnelling technology can be applied to a variety of energy underground storage tunnels such as Compressed Natural Gas(CNG), Liquifed Petroleum Gas(LPG), DeMethyl Ether(DME) etc.

Study on the Test Methods and Performance Criterion of High Insulated Door (고기밀.고단열 문의 성능평가 및 기준설정에 관한 연구)

  • Kang, Jae-Sik;Choi, Gyoung-Seok;Kim, Kyoung-Woo;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.618-622
    • /
    • 2009
  • About a Structure is performance insulation include air-tight is fundamental performance for energy-saving. The Apartment house of permission balcony enlarged to increase the requirement of market of high-effective door. Since 2001 years the window and wall of insulation performance stronger frailty than keep up performance insulation that increase influence building energy generated heat loss at door. In study on presentation that high-insulation, air-tight door about experimental method and performance standard.

  • PDF

Antioxidative Effects of Some Antioxidants according to Storage Conditions of Cooked Soybean Oil (가열유지의 저장조건에 따른 일부 항산화제의 항산화 효과)

  • Yoon, Soo-Hong;Lee, Myoune-Jin;Park, Byoung-Yoon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.17 no.2
    • /
    • pp.158-163
    • /
    • 1988
  • The changes of the physico-chemical properties and fatty acid compositions of cooked soybean oil, 30 min at $180{\pm}5^{\circ}C$, were investigated to compare the antixidative effects of some antioxidants such as BHA, ${\alpha}-tocopherol$ and sesamol according to various storage conditions(room temperature, room temperature with a air tight in the dark and low temperature with air tight) for 4 weeks. The order of antioxidative effects according to different storage conditions was low temperature with air tight, room temperature with air tight in the dark and room temperature. Acid values, peroxide values and carbonyl values of soybean oil stored under low temperature with air tight after ${\alpha}-tocopherol$ treatment were similar to those of soybean oil stored under room temperature after BHA treatment. The relative contents of linoleic acid and linolenic acid decreased during storage, wheras those of oleic acid and palmitic acid increased. The contents of linoleic acid in soybean oil treated with ${\alpha}-tocopherol$ and BHA under low temperature with air tight storage were $53.61{\sim}50.29%$ and $53.78{\sim}50.68%$, respectively. These contents were very high in comparison with those in untreated oil under room temperature storage, $52.09{\sim}43.96%$.

  • PDF

Determination of the repair grout volume to fill voids in external post-tensioned tendons

  • Im, Seok Been;Hurlebaus, Stefan
    • Structural Engineering and Mechanics
    • /
    • v.42 no.1
    • /
    • pp.25-38
    • /
    • 2012
  • Recently, investigated failures of external post-tensioned (PT) tendons have called attention to the corrosion of strands in PT bridges, and the prevention of ongoing corrosion is required to secure their structural integrity. Since voids inside ducts can be a source for the ingress of water or deleterious chemicals, the vacuum grouting (VG) method and a volumeter for estimating amount of repair grouts were employed to fill voided ducts. However, the VG method is expensive and time-consuming for infield application because it requires an air-tight condition of entire ducts. Thus, latest research assessed three different repair grouting methods, and the pressure vacuum grouting (PVG) method was recommended in the field because it showed good filling capability in voided ducts and did not require an air-tight condition. Thus, a new method is required to estimate the volume of repair grouts because the PVG method is not applied in air-tight ducts. This research assesses the relationship between voided areas on ducts identified with soundings and required grout volume for repair using experimental results. The results show that the proposed equations and assumptions for estimating repair grout volume provide a sufficient amount of repair grouts for filling voided ducts.

Inhibitory effect of ethanol extract of Codonopsis lanceolata against oxidative stress and disruption of tight cell junction in NCI-H441 cells after exposure to urban particulate matter (더덕 에탄올 추출물의 도시미세먼지 노출로 인한 폐 세포 산화스트레스 발생과 세포밀착연접 손상 억제 효과)

  • So, Hee-Jung;Chun, Su-Hyun;Lee, Jin-Won;Lee, Kwang-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.2
    • /
    • pp.165-173
    • /
    • 2021
  • One of the major sources of air pollution is urban particulate matter (UPM), which causes lung diseases involving oxidative stress, inflammation, and cancer. Codonopsis lanceolata (CL) has been used in East Asia as a traditional oriental medicinal ingredient for lung diseases (e.g., asthma and bronchitis). However, the connection between the impact of CL and UPM in the lungs has rarely been investigated. This study aimed to confirm the inhibitory activity of the ethanol extract of CL (ECL) against oxidative stress and disruption of tight cell junctions in human pulmonary epithelial cells after exposure to UPM. As the lung cells were pre-treated with ECL, the UPM-induced increase in cellular reactive oxygen species production suppressed tight junction proteins (e.g., N-cadherin, fibronectin, occludin, zonula occludens-1, and claudin-4). These results suggest that ECL prevents the possible effects of UPM toxicity on the lungs.

A Study on the Environment Planning of Exhibition Space for Conservation of Collection in a Museum (박물관자료의 보존을 위한 전시공간 환경계획에 관한 연구)

  • Jung, Sung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.2
    • /
    • pp.91-101
    • /
    • 2008
  • The purpose of this study is to suggest the design guidelines of exhibition space for conservation of collection in a museum. With the purpose of this study, examined the concept and a condition of conservation which is focused on deterioration in a exhibition space, investigated the actual condition of total 42 facilities and analyzed the specific instance which is excellent by factor of environment plan. Hereupon, the results of this study are as follows. First, exhibition space should be equipped with sufficient 'Filtering Space' before the outdoor and located central territory in a museum facility. Second, exhibition space should be partition off an area into the quality of collection, and then controlled by each of them. Third, in consideration of the annual air fluctuation of our country, the database which is adaptable for setting up the standard of temperature and RH must be prepared. Fourth, it is necessary to establish a 'Reference Exhibition Room' which is formed cellular type and a 'Garnering Exhibition Center'. Fifth, for the prevention of deterioration which is generated in exhibition space, the showcase must be high air-tight. Sixth, it is necessary to reduce a inside space of high air-tight showcase. Seventh, art-sorb is suitable for control the organic matter of collection and a except of fiber optics is not suitable for lighting of showcase. Eighth, wall-type showcase should be have air-chamber which is formed like museum storage and run over 8 hours a day.

Air Change Rate Measurement Methods and Database

  • Lee, Kiyoung;Yukio Yanagisawa
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.E
    • /
    • pp.1-12
    • /
    • 1995
  • In recent years the demand for energy conservation has resulted in "tight" buildings with decreased air change rates. Although a reduction in air change rates can save energy utilized for heating or cooling of dwellings, there is an increased concern for the air quality of the indoor environment where individuals spend most of their lifetime (Schwab et al., 1990).., 1990).

  • PDF

Development of Tight-Fitting Garments with a Portable ECG Monitor to Measure Vital Signs (휴대용 심전도 기기와 직물형 전극을 이용한 생체정보 측정용 밀착 의복 개발)

  • Jeong, Yeon-Hee; Kim, Seung-Hwan;Yang, Young-Mo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.1
    • /
    • pp.112-125
    • /
    • 2010
  • A Holter monitor is used for ECG monitoring of ambulatory daily life in hospital. However, the use of this apparatus causes skin allergies and discomfort in patients because of the attachment gel and tapes used to attach disposable electrodes to the skin. In this study, the development of tight-fitting clothing connected to a portable Holter monitor was proposed. In addition, the use of conductive fabrics as electrodes was proposed; this will enable the use of garments in u-health care for measuring ECG signals. The male subjects were university students in the ages of 20 to 24. Subjective wear sensations of the experimental garments were rated using seven Likert scales. A Likert type scale was used for the evaluation and a 7 point score indicates that it provided the best fit as a tight-fitting upper clothing. Clothing pressure was measured using an air-pack-type pressure sensor (model AMI 3037-2) at 4 locations (the conductive fabric electrode) As results, a male basic sloper for upper clothing was developed and that pattern was manipulated to the tight fit pattern by considering the reduction rate of the percentage stretch in the fabric. The developed tight-fitting garment was superior in terms of subjective sensation and 6t. The mean pressure of the garment with reduction rates of 40% in width and of 50% in length was 8.45gf/$cm^2$. A conductive fabric electrode was developed by considering the sewing method and the developed electrode was detected well. The ECG data were recorded for 13 hr 19 min 44 sec and the artifacts in the ECG signals were recorded for 9 hr 3 min 46 sec (total time: 22 hr 23 min 23 sec). The artifacts data were obtained during heavy activities.

A Study on Buffering Effect of Silicagel to Control Relative Humidity in Air-tight Case (밀폐장내(密閉欌內) 실리카겔의 습도조절(濕度調節) 효과(效果) 연구(硏究))

  • Kim, Myoung-nam;Yu, Hei-sun
    • Conservation Science in Museum
    • /
    • v.2
    • /
    • pp.77-82
    • /
    • 2000
  • The purpose of this study is to evaluate the effect of ART-SORB which is commonly used in museums and galleries at home and abroad including National Museum of Korea, so as to collect useful information to control micro-environment. Experiment was conducted in air-tight condition in order to evaluate only the effect of ART-SORB excluding any influence from outside factors. A certain amount of ART-SORB considering the case size and ART-SORB in cassette type were used to evaluate the humidity controlling capability. The result showed that target humidity was reached in 10~17 hours in case of using corresponding amount of ART-SORB to the cubic volume and in 5~6 hours in case of excessive use of cassette type ART-SORB. And it also showed that humidity can be controlled in the range of RH 50~70%. In addition, ART-SORB was excellent at raising humidity at low humidity and poor at high humidity. Therefore, ART-SORB turned out to be an effective humidity buffer for controlling micro-environment of such artifacts as wooden ware, lacquer ware and paintings, which require high humidity. However, unfortunately, there are some difficulties in applying this result to real condition, given the fact that this study was conducted under firm air-tight case. Therefore, ART-SORB can be fully effective only in firm air-tight case.

Comparison of middle-aged women's bodice pattern using 3D data -focused on the DC Suite program-

  • Cha, Su-Joung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.1
    • /
    • pp.91-102
    • /
    • 2018
  • The purpose of this study is to develop an excellent bodice prototype that is adapted to the body shape of middle-aged women using 3D measurement data. In the evaluation of appearance, S pattern 4.00, B pattern 2.80, E pattern 2.40, L pattern 1.40 were shown in order, and the best fit of S pattern was evaluated as excellent. As a result of looking at the color distribution chart to find out the amount, E pattern and S pattern were not space in the front bust, armhole, and the back waist line. The B pattern and the L pattern were marked in blue because of insufficiency space in the back neck. As a result of evaluation the amount of air gap in the clothing, the air gap of the bust was 0.12, which is the largest pattern of B. Next, the L pattern appears as a tight circle with smallest air gap in the order of the S pattern 0.096, the E pattern 0.08, and the L pattern 0.003. The S pattern was evaluated to be the most appropriate for the body shape of middle-aged women. But the waist and back were slightly tight. Middle-aged women have larger shoulder-related items and larger waist circumference. Therefore, when you set the perimeter item, you should add 1-2cm of space amount and give extra space to the circumference area.