• 제목/요약/키워드: Air-side performance

검색결과 333건 처리시간 0.027초

데이터센터의 외기도입 냉방시스템 적용에 따른 경제성 평가 (Economic Evaluation of Air-side Economizer System for Data Center)

  • 박성현;서장후
    • 설비공학논문집
    • /
    • 제26권4호
    • /
    • pp.145-150
    • /
    • 2014
  • Many studies are being conducted with the aim of reducing the energy consumption in data centers, which are one of the highest consumers of energy. The use of an air-side economizer system that uses external air during intermediate and winter seasons is being considered for reducing the energy consumption of air conditioners. In this study, using the energy simulation, we evaluated the energy performance of a central chilled water cooling system and air-side economizer system in domestic data centers. Further, the cost-effectiveness of the air-side economizer was analyzed through Life-Cycle Cost Analysis. The results showed that with the use of air-side economizer systems, the energy costs increased as the applied filter grade increased; however, unlike existing central chilled water systems, it would break even within 2 years.

Impact of Air-side Economizer Control Considering Air Quality Index on Variable Air Volume System Performance

  • Cho, Sang-Hyeon;Park, Joon-Young;Jeong, Jae-Weon
    • 국제초고층학회논문집
    • /
    • 제6권1호
    • /
    • pp.101-111
    • /
    • 2017
  • The objective of this study is to determine the effectiveness of a modified air-side economizer in improving indoor air quality (IAQ). An air-side economizer, which uses all outdoor air for cooling, affects the building's IAQ depending on the outside air quality and can significantly affect the occupants' health, leading to respiratory and heart disease. The Air Quality Index (AQI), developed by the US Environmental Protection Agency (US EPA), measures air contaminants that adversely affect human beings: PM10, PM2.5, SO2, NO2, O3, and CO. In this study, AQI is applied as a control for the operation of an air-side economizer. The simulation is analyzed, comparing the results between the differential enthalpy economizer and AQI-modified economizer. The results confirm that an AQI-modified economizer has a positive effect on IAQ. Compared to the operating differential enthalpy economizer, energy increase in an operating AQI-modified economizer is 0.65% in Shanghai and 0.8% in Seoul.

다공형 전열판의 회전에 의한 열교환시스템의 성능에 관한 연구(Ⅰ) - 환기측과 외기측의 풍량 변화에 대하여 - (Study on the Performance of Total Heat Exchanger with Rotating Porous Plates)

  • 조동현;임태우
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.11-17
    • /
    • 2005
  • This paper reports an experimental study on the performance evaluation of air-to-air heat exchanger with rotary type newly developed in this study. Air flow rate is varied from 10 to 120 m3/h. The range of RPM of the porous rotating discs mounted inside the heat exchanger unit is 0 to 50. The temperature of the return air side is set by adjusting heat supply at heater. The material of the porous rotating discs is cooper and its thickness is 1.0 mm. The heat transfer rate increased with the increase in air flow rate. It was found that the heat transfer rate, as the temperature of the return air side was increased, was improved due to higher temperature difference. The heat exchange performance increased with the increase in the temperature of the return air side at the conditions of the same RPM. The sensible heat exchange efficiency was maximum 68 to 76 percent, and enthalpy exchange efficiency 64 to 74 percent.

  • PDF

외기 온도 변화가 핀-관 열교환기의 공기측 열전달계수와 마찰계수에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of the Air Temperature on the Air-Side Heat-Transfer Coefficient and the Friction Factor of a Fin-and-Tube Heat Exchanger)

  • 김내현;조홍기
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.149-158
    • /
    • 2017
  • In general, the air-side j and f factors of evaporators or condensers are obtained through single-design tests performed under air-dry and wet-bulb temperatures. Considering that the indoor or outdoor air temperatures vary significantly during the operation of an air conditioner, it is necessary to confirm that the experimentally-obtained j and f factors are widely applicable under variable air conditions. In this study, a series of tests were conducted on a two-row slit-finned heat exchanger to confirm the applicability. The results showed that, for the dry-surface condition, the changes of the tube-side water temperature, water-flow rate, and air temperature had virtually no effect on the air-side j and f factors. For the wet condition, however, the f factor was significantly affected by these changes; contrarily, the j factor is relatively independent regarding this change. The formulation of the possible reasoning is in consideration of the condensation behavior underneath the tube. The wet-surface j and f factors are larger than those of the dry surface, with a larger amount for the f factor.

차량용 열제어 관리 시스템의 성능 시뮬레이션 프로그램 개발 (Development of Simulation Program of Vehicle Thermal Managements System)

  • 배석정;허형석;김현철
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.345-348
    • /
    • 2008
  • The computer-aided performance simulation can reduce periods for development of products and cut down on the cost comparing with former trial-and-error procedures. This study has developed a simulation program for a vehicle thermal management system integrating an engine cooling system and an air conditioning system considering interactions and arrangement of air side heat exchangers such as power steering oil cooler, air-cooled transmission oil cooler, condenser, and radiator. The program may be also used for the system performance analysis according to the configuration of the engine coolant side heat exchangers such as water-cooled transmission oil cooler, EGR cooler, and heater core. Experiments utilizing an environmental wind tunnel has been conducted to assess the performance of the system according to the arrangement of air side heat exchangers. Some modification of the coolant loop layout can enhance the heat core performance up to 7% according to the results of the simulations.

  • PDF

Impacts of Fouling and Cleaning on the Performance of Plate Fin and Spine Fin Heat Exchangers

  • Pak, Bock-Choon;Baek, Byung-Joon;Eckhard A. Groll
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1801-1811
    • /
    • 2003
  • An experimental study was conducted to investigate the effects of air-side fouling and cleaning on the performances of various condenser coils used in unitary air-conditioning systems. A total of six condenser coils with different fin geometry and row number were tested. Performance tests were performed at three different conditions: clean-as-received, after fouling, and after cleaning. In all cases, it was observed that the fouling was mostly confined to the frontal face of the heat exchanger as reported in the previous investigations. The amount of deposited dust was more dependent on fin geometry for the single-row heat exchangers than for the double-row heat exchangers. The predominant effect of fouling was to cause a more significant increase in air-side pressure drop than a degradation in heat transfer performance. For the single-row heat exchangers, the pressure drop increased by 28 to 31%, while the heat transfer performance decreased by 7 to 12% at the standard air face velocity of 1.53 m/s depending on fin shape. For the double-row heat exchangers, the pressure drop increased by 22 to 37%, and heat transfer performance decreased by only 4-5% at the same air face velocity. Once the contaminated coils were cleaned according to the given cleaning procedure the original performance of the heat exchangers could almost be recovered completely. The pressure drop could be restored within 1 to 7% and the heat transfer performance could be recovered to within 1 to 5% of the originally clean heat exchangers. Therefore, it is concluded that a periodic application of the specified cleaning technique will be effective in maintaining the thermal performance of the condenser coils.

공기조화기용 열교환기의 공기측 파울링 입자 분석 연구 (Characteristics of the Air-side Particulate Fouling Materials in Finned-Tube Heat Exchangers of Air Conditioners)

  • 안영철;신희수;황유진;이창건;이재근;이현욱;안승표;윤덕현;하삼철
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.611-617
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the characteristics of the air-side particulate fouling materials in finned-tube heat exchangers of air conditioners. Air conditioners being used in the field such as inns, restaurants, and offices are collected in chronological order in use. Typical fouling materials on the heat exchangers include fibers and dusts ranged from 6.6 to 20.9 ${\mu}{\textrm}{m}$ in mass median diameter.

Performance Analysis of an Indoor Heat Exchanger with R-410A for GHP Application

  • Lee, Jong-Ho;Kim, Sung-Soo;Cha, Woo-Ho;Kang, Yong-Tae
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권4호
    • /
    • pp.129-134
    • /
    • 2009
  • The objectives of this paper are to study the effects of thermal and geometric conditions on the performance of indoor heat exchangers with R-410A for Gas Engine Driven Heat Pump (GHP) application and to find the optimum design conditions of indoor heat exchangers by parametric analysis for the key parameters. The key parameters are number of tube row, number of tube pipe, fin pitch and transverse tube pitch. In the air side, moisture out of the humid air condenses on the fin surface while the refrigerant (R-410A) boils inside the smooth tube. Therefore this study uses Log Mean Enthalpy Difference (LMHD) method to analyze the heat transfer from the humid air to the refrigerant. This study determines the heat exchanger size, air side/refrigerant side pressure drop and overall heat transfer coefficient. Optimum design conditions for the key parameters are also determined by the parametric analysis. The results show that number of rows and pipes, fin pitch have significant effect on the heat exchanger size. It is also found that the tube length of the louver fin is $17{\sim}30%$ shorter than that of the plate fin.

변압기용 방열기의 방열판 형상이 방열특성에 미치는 영향에 관한 수치적 연구 (NUMERICAL STUDY ON THE EFFECT OF THE SHAPE OF THE HEAT TRANSFER PLATE ON THE THERMAL PERFORMANCE OF THE RADIATOR)

  • 김영주;두정훈;하만영;손성완;김중경;이승호
    • 한국전산유체공학회지
    • /
    • 제20권1호
    • /
    • pp.65-76
    • /
    • 2015
  • In this study, the natural convection phenomenon of the air side and the forced convection phenomenon of the oil side were simulated in the radiator through a 3-D numerical analysis, and the total heat released by the oil side into the radiator heating plate and then to the air side was evaluated. Also, a quantitative analysis was carried out on the effect of each thermal resistance on the overall heat transfer coefficient through a 1-D thermal circuit analysis on the heat transfer mechanisms of the radiators considered in this study. In addition, for the diverse shapes of the heating plates considered in this study, the pressure drops of the oil side were quantitatively compared and evaluated. The temperatures at the air side and the oil side outlets of the radiators with 8 different fin shapes considered in this study had almost similar values showing a difference of +/-3% and, accordingly, the total heat transfer also showed similar heat dissipation performance in all the models. As a result of the 1-D thermal circuit analysis, in all the models considered in this study, while the thermal resistance of the air side accounted for 92% to 96% of the total, that of the oil side was 5 to 7%, and that of the heating plate showed a very small value of 0.02%.

자동차 냉각수 폐열회수 열전발전 시스템의 성능에 관한 연구 (An Experimental Study on Thermoelectric Generator Performance for Waste Coolant Recovery Systems in Vehicles)

  • 이대웅
    • 설비공학논문집
    • /
    • 제26권7호
    • /
    • pp.329-334
    • /
    • 2014
  • This study indicated the possibility of energy regeneration from waste coolant heat, by using thermoelectric generation integrated with heat pipe. The internal combustion engine rejects more than 60% wasteful energy to the atmosphere by heat. The thermoelectric generator has recently been studied, to convert the energy from engine waste heat into electricity. For coolant waste heat recovery, a thermoelectric generator was investigated, to find out the possibility of vehicular application. Performance characteristics were conducted with various test conditions of coolant temperature, coolant mass flow rate, air temperature, and air velocity, with the thermoelectric generator installed either horizontally or vertically. Experimental results show that the electric power and conversion efficiency increases according to the temperature difference between the hot and cold side of the thermoelectric generator, and the coolant flow rate of the hot side heat exchanger. Performance improvement can be expected by optimizing the heat pipe design.