• Title/Summary/Keyword: Air-side

Search Result 1,198, Processing Time 0.026 seconds

Advances In Air-Cooled Heat Exchanger Technology for Residential Air-Conditioning

  • Webb Ralph L.;Kim Nae-Hyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.4
    • /
    • pp.184-195
    • /
    • 2005
  • This paper describes the recent work on advanced technology concepts applied to air cooled heat exchangers for residential air-conditioning. The concepts include vortex generators for the air-side, micro-fin or flat tubes for the refrigerant-side. Advances in understanding of heat transfer mechanisms, predictive models are discussed.

Heat Transfer Analysis of a Heat Exchanger for an Air-Compressor of a Railway Vehicle Based on Cooling Air Flow Measurement (냉각공기 유속 측정에 기반한 철도차량용 공기압축기 열교환기의 열전달 특성 분석)

  • Ahn, Joon;Kim, Moo Sun;Jang, Seongil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.447-454
    • /
    • 2017
  • In this study, local velocity distribution of cooling air in a heat exchanger used in an air compressor for a railway car was measured and heat transfer characteristics of the heat exchanger were analyzed. First, heat transfer coefficient and fin performance of the cooling air side were predicted and was checked if the fin of the heat exchanger was effectively used. Distribution of air flow rate at high temperature side was predicted through pipe network analysis and heat resistance at high temperature and low temperature side were predicted and compared. Spatial distribution of temperature in the interior and surface of the square channel constituting high-temperature side was predicted and appropriateness of the size of the heat exchanger was examined. As a result of the analysis, the present size of the heat exchanger could be reduced and it could be effective to promote heat transfer inside the heat exchanger rather than outside to improve performance of the heat exchanger.

New Crash Discrimination Algorithm and Accelerometer Locations (새로운 충돌 판별 알고리즘과 가속도 센서의 위치)

  • 정현용;김영학
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.182-193
    • /
    • 2000
  • Several metrics have been used in crash discrimination algorithms in order to have timely air bag deployment during all frontal crash modes. However, it is still challengine to have timely air bag deployment especially during the oblique, the pole and the underride crash mode. Therefore, in this paper a new crash discrimination algorithm was proposed, using the absolute value of the deceleration change multiplied by the velocity change as a metric, and processing the metric as a function of the velocity change. The new algorithm was applied for all frontal crash modes of a minivan and a sports utility vehicle, and it resulted in timely air bag deployment for all frontal crash modes including the oblique, the pole and the underride crash mode. Moreover, it was proposed that an accelerometer be installed at each side of the rails, rockers or pillars to assess the crash severity of each side and to deploy the frontal air bags at different time especially during an asymmetric crash such as an oblique and an offset crash. As an example, the deceleration pulses measured at the left and right B-pillar·rocker locations were processed through the new algorithm, and faster time-to-fires were obtained for the air bag at the struck side for the air bag at the other side.

  • PDF

An Experimental Study on Heat Transfer and Pressure Drop of Air Side in a Plate-Louvered Fin Heat Exchanger (평판관-루버핀 열교환기의 공기측 열전달 및 압력강하 특성에 관한 실험적 연구)

  • 강병하;김석현;장혁재;박병규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.485-492
    • /
    • 2002
  • Heat transfer and pressure drop on the air side of a plate-louvered fin heat exchanger with new shape of louver fin have been investigated experimentally. Water is employed inside the flat tube to transfer heat with air for convenience. This problem is of particular interest in the design of a plate-louvered heat exchanger. The effect of air flow rate, water flow rate and water temperature on pressure drop as well as heat transfer in air side are studied in detail. The present results showed a good agreement qualitatively with the previous results in general. Based on the experimental data, f-factor and j -factor correlations of the present louvered-fin are suggested. It is also found that heat transfer could be enhanced with new shape of louver fin, compared with the conventional louvered-fin, while the f-factor remains unchanged.

Development of Control Algorithms for a $CO_2$ Automotive Air Conditioner System by Using Experimental data (실험 데이터를 사용한 자동차 $CO_2$ 냉방시스템의 제어 알고리즘 개발)

  • Han, Do-Young;Jang, Kyung-Chang
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.681-686
    • /
    • 2006
  • In order to protect the environment from the refrigerant pollution, the $CO_2$ may be regarded as one of the most attractive alternative refrigerants for an automotive air-conditioning system. Control methods for a $CO_2$ system should be different because of $CO_2's$ unique propel-ties as a refrigerant. Especially, the high-side pressure of a $CO_2$ system should be controlled for the effective operation of the system. In this study, dynamic models of a $CO_2$ air-conditioning system were developed by using experimental data. Control algorithms for a high-side pressure control and an indoor air temperature control were developed and analysed by using the dynamic simulation program of a $CO_2$ system.

  • PDF

A Study of the Sol-Air Temperature for the Calculation of Insulation in Cryogenic Storage Tank (저온용 저장탱크의 보온계산을 위한 Sol-Air 온도에 관한 연구)

  • Son, Byung-Jin;Maeng, Joo-Sung;Hong, Sung-Min
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.2
    • /
    • pp.98-107
    • /
    • 1985
  • In this thesis, the Sol-Air temperature distribution for the side-wall of a cylindrical cryogenic storage tank made of nonhomogenious composite layer was studied, in order to calculate the thermal load by Newton's cooling law, when the solar radiation was applied upon the side wall. In the analysis, the atmospheric slab was assumed to be horizontal and infinitely large, and the Sol -Air temperature, which was found by the Net- Radiation method considering the longwave radiation wi th surroundings, was used for boundary condition. Energy equation and boundary conditions were normalized by the defined reference- temperature, and solved. The solutions were developed by the Fourier cosine series. Then, the Sol-Air temperature distribution for the side-wall of LNG storage tank was calculated.

  • PDF

Evaluation of Air-side Friction Characteristics on Design Conditions of Slit Fin and Tube Heat Exchanger (슬릿휜-관 열교환기의 설계조건에서 공기측 압력강하 산출)

  • Cho, Sung-Chul;Kim, Chang-Duk;Kim, Chang-Eob;Kwon, Jeong-Tae;Lim, Hyo-Jae
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.149-154
    • /
    • 2007
  • An experimental study on the air-side pressure drop of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side pressure drop in the literature is not based on a consistent approach. This paper focuses on method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry and wet surface pressure drop estimation in fin-tube heat exchanger. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the air-side pressure drop on design conditions of condenser and evaporator. Results are pre-sented as plots of friction f-factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of $150{\sim}250\;kg/m^2s$ with air flows at velocity ranges from 0.38 m/s to 1.6 m/s.

Displacement Control of Pneumatic Actuator Equipped with PLC and Proximity Sensors (PLC와 근접센서를 이용한 공압 실린더의 변위제어)

  • Kim, Gun-Hoi;So, Jung-Duck
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.2
    • /
    • pp.90-96
    • /
    • 2008
  • A pneumatic system was proposed to evaluate displacement accuracy of the pneumatic actuator without external load and to analyze capability of integration of the proposed valve system. The proposed pneumatic system consisted of a combination of pneumatic valves, two proximity sensors, and a programmable logic controller(PLC). The position controller is based on the PLC controller connected with the proximity sensors. Displacement accuracy of the pneumatic cylinder stroke was tested by varying air pressures of the supply and discharge-side and strokes of the pneumatic cylinder. The displacement accuracy of the pneumatic cylinder stroke increased as the supply and discharge side of air pressure increased at the stroke length of 133mm. Also the displacement accuracy increased as the stroke length increased with a fixed supply and discharge side of air pressure of the pneumatic cylinder as 3.5 and $4.5kg/cm^2$, respectively. The most accurate displacement of the pneumatic cylinder(i.e., standard deviation of 0.01 mm) was obtained at the supply and discharge side of air pressure of 4.0 and $5.0kg/cm^2$, respectively, and strokes of 170 and 190 mm among arbitrarily selected supply and discharge side air pressures and strokes.

Optimal Design of Blowing Plates to Minimize the Freezing Phenomena in the Freezer of a Side-by-side Refrigerator (양문 여닫이형 냉장고 냉동실 결빙 최소화를 위한 토출구형상 최적설계)

  • Kwak, S.M.;Lee, Y.H.;Kum, J.S.;Kim, N.S.;Kim, S.B.;Lee, Y.W.
    • Journal of Power System Engineering
    • /
    • v.7 no.2
    • /
    • pp.17-22
    • /
    • 2003
  • As side-by-side refrigerators came into existence, there has been a growing concern about the free%ins-up of the vital equipment in a walk-in freezer. Due to a bad performance, customers are experiencing too much frustration. In order to minimize the freezing phenomena, the numerical simulation has been performed on the characteristics of cold air flow in a side-by-side refrigerator. The flow field has been simulated with a standard $k-\varepsilon$ turbulent model and a SIMPLE algorithm based on the finite volume method. Through the results of the analysis of the pattern of cold air flow, finally the shape of outlet for cold air flow was modified. The present model was compared with the modified model. The latter was better than the former in minimizing the freezing phenomena.

  • PDF

The High-side Pressure Setpoint Algorithm of a $CO_2$ Automotive Air Conditioning System by using a Lagrange Interpolation Method and a Neural Network (라그랑즈 보간법과 신경망을 이용한 $CO_2$ 자동차에어컨시스템의 고압설정알고리즘)

  • Han, Do-Young;Noh, Hee-Jeon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.29-33
    • /
    • 2007
  • In order to protect the environment from the refrigerant pollution, the $CO_2$ may be regarded as one of the most attractive alternative refrigerants for an automotive air-conditioning system. Control methods for a $CO_2$ system should be different because of $CO_2$'s unique properties as a refrigerant. Especially, the high-side pressure of a $CO_2$ system should be controlled for the effective operation of the system. In this study, the high-side pressure setpoint algorithm was developed by using a neural network and a Lagrange interpolation method. These methods were compared. Simulation results showed that a Lagrange interpolation method was more effective than a neural network in the respect of its easiness of programming and shorter execution time.

  • PDF