Louvered fin 열교환기(熱交換器)의 공기측(空氣側) 열전달(熱傳達) (Air-Side Heat Transfer in Louvered Fin Heat Exchangers)

  • 김선정;권순석
    • 설비공학논문집
    • /
    • 제1권1호
    • /
    • pp.82-86
    • /
    • 1989
  • A study has been conducted experimentally on heat transfer characteristics of the heat exchangers with louvered fins in air. The experimental results are as follows; 1. Mean heat transfer coefficient is decreased with increasing temperature difference and model III is the best at constant temperature difference. 2. Pressure drop is increased with increasing air velocity, but it is decreased as the heat transfer area increases. 3. $\bar{h}/^{\Delta}p$ is increased and then decreased as air velocity increases.

  • PDF

Bell's Palsy 환자의 건측-환측 안면부 피부온도차이에 관한 연구 (Differences Between Facial Skin Temperature of the Paralyzed Side and Those of the Normal Side in Bell's Palsy Patients)

  • 남동현;고형균;박영배
    • 대한한의학회지
    • /
    • 제28권1호통권69호
    • /
    • pp.126-136
    • /
    • 2007
  • Objectives : Bell's palsy in an acute peripheral facial nerve paralysis that usually affects only one side of the face. The seventh cranial nerve carries predominantly motor fibers, but also supplies some autonomic innervation, sensation to park of the ear, and taste to the anterior two thirds of the tongue. The aim of this study is to provide evidence of differences between facial skin temperature of the paralyzed side and normal side in Bell's palsy patients. Methods : the author studied 68 patients with Bell's palsy whose facial nerve function had been documented by the House-Brackmann grading system. We measured skin temperature of the forehead, zygoma, lower lip, temple and lower jaw area of the paralyzed side and those of the normal side. Results : there were significant facial skin temperature differences between the forehead area of paralyzed side and that of normal side of GrII(P<0.05) and III(P<0.05). The result also showed that the facial skin temperature difference according to the aflection period vanished when air temperature was calibrated (F=1.700, P=0.178). Conclusions : Thermography is a useful diagnostic tool in Bell's palsy if the air temperature is low enough to cool the facial skin temperature and the forehead area is evaluated as the sampling zone.

  • PDF

Impacts of Fouling and Cleaning on the Performance of Plate Fin and Spine Fin Heat Exchangers

  • Pak, Bock-Choon;Baek, Byung-Joon;Eckhard A. Groll
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1801-1811
    • /
    • 2003
  • An experimental study was conducted to investigate the effects of air-side fouling and cleaning on the performances of various condenser coils used in unitary air-conditioning systems. A total of six condenser coils with different fin geometry and row number were tested. Performance tests were performed at three different conditions: clean-as-received, after fouling, and after cleaning. In all cases, it was observed that the fouling was mostly confined to the frontal face of the heat exchanger as reported in the previous investigations. The amount of deposited dust was more dependent on fin geometry for the single-row heat exchangers than for the double-row heat exchangers. The predominant effect of fouling was to cause a more significant increase in air-side pressure drop than a degradation in heat transfer performance. For the single-row heat exchangers, the pressure drop increased by 28 to 31%, while the heat transfer performance decreased by 7 to 12% at the standard air face velocity of 1.53 m/s depending on fin shape. For the double-row heat exchangers, the pressure drop increased by 22 to 37%, and heat transfer performance decreased by only 4-5% at the same air face velocity. Once the contaminated coils were cleaned according to the given cleaning procedure the original performance of the heat exchangers could almost be recovered completely. The pressure drop could be restored within 1 to 7% and the heat transfer performance could be recovered to within 1 to 5% of the originally clean heat exchangers. Therefore, it is concluded that a periodic application of the specified cleaning technique will be effective in maintaining the thermal performance of the condenser coils.

공기 흡입 엔진의 총추력 추정 기법 (The Gross Thrust Estimation Technique of Air-Breathing Engine)

  • 김정우;정치훈;안동찬;이규준
    • 한국추진공학회지
    • /
    • 제22권3호
    • /
    • pp.97-108
    • /
    • 2018
  • 공기 흡입 엔진을 개발하기 위해서는 지상 시험을 통한 추력 측정이 반드시 필요한데, 공기 흡입 엔진은 추력 측정 장치에서 측정된 값 이외에도 엔진 흡입구로 들어오는 공기 유동에 의한 힘을 고려하여 총추력을 계산해야 한다. 또한 다분력 추력 측정 장치를 활용하여 요와 피치 방향의 측추력도 정확하게 측정하고 분석할 수 있어야 한다. 래버린스 씰 격리, 1축 총추력 계산, 다분력 추력 측정 장치 개발, 측추력 분석 등의 일련 과정을 통해 공기 흡입 엔진의 총추력을 정밀하게 추정하여 엔진 성능을 보다 정확하게 평가할 수 있게 하였다.

공기분사공법을 이용한 초대형 Open Caisson의 침하촉진에 대한 사례연구 (A Case Study on Settlement Promotion of a Large Size Open Caisson using Air-Jet an Method)

  • 정진섭;이종천;김해욱;김태형
    • 한국항해항만학회지
    • /
    • 제33권3호
    • /
    • pp.227-233
    • /
    • 2009
  • 본 실험 연구는 공기분사공법의 오픈케이슨기초의 주면마찰력 저감효과에 대해 규명하기 위해 이루어졌다. 연육교 건설을 위해 기초로 사용된 공기구멍이 설치된 대구경 케이슨이 본 연구를 위해 이용되었다. 공기분사공법을 사용 시, 침하 시간을 줄일 수 있었으며 일반전인 방법으로 도달할 수 없는 깊이까지 침하를 시킬 수 있었다. 또한, 예상했던 것 보다 두 배 이상의 주면마찰저항력 저항 저감 효과를 얻었으며, 이런 장점 외 추가적인 외부의 재하하중 없이도 케이슨을 침하시킬 수 있음을 보여주었다. 그 외 오픈케이슨 침설 시 발파에 의한 케이슨 손상을 공기분사공법을 이용하면 방지할 수 있음을 보여주었다.

3차원 시뮬레이션을 활용한 성인여성용 길 원형 비교 연구 - DC Suite Program을 중심으로 - (Comparison of basic bodice block for adults women by 3D simulation - focus of the DC Suite Program -)

  • 차수정;강연경
    • 패션비즈니스
    • /
    • 제17권2호
    • /
    • pp.63-81
    • /
    • 2013
  • A Study using compare and analyze about differences among three patterns(shape and size of pattern, fitting and amount of air gap and so on) through 3D simulation. This study use 3D simulation program, DC Suite version 3.0. The results are as a follows: The results of estimation about total appearance, the pattern of Bunka is best of all pattern about total fitting and silhouette of front and back side. The pattern of armstrong and on&on stand low in estimation. As the total fitting, the pattern of Bunka is 4.40, the pattern of Armstrong is 2.60 and the pattern of On&on is 1.60. The result show better pattern of Bunka than pattern of Armstrong and On&on. When we examine about space between body and cloth, the pattern of Bunka is best. The pattern of Armstrong don't have problems about back side but front side have some problem of getting loose. Because it only have a waist dart so dart size is too big. The pattern of On&on have so much space because it don't have a waist dart. On the amount of air gap, the pattern of Bunka squash up body so it have the amount of air gap 0.08 at bust circumference and underbust circumference. Next is the pattern of Armstrong, amount of air gap is 0.14 at bust circumference and 0.23 at underbust circumference. The pattern of On&on's amount of air gap is 0.30 at bust circumference and 0.37 at underbust circumference. So the pattern of Bunka is bodice block of the best closing adhesion and the On&on is a loose-fitting pattern.

칠드빔 유니트의 최적설계 및 성능평가 연구 (Study on Optimal Design and Performance Test of Chilled Beam Unit)

  • 김정엽;신현준;주상현;김지석
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.11-18
    • /
    • 2014
  • Chilled Beam system is the kind of water-air system which reduces the conveyance energy for air conditioning as well as allows efficient installation and comfortable indoor environment, and has been increasingly popular mainly in Europe. To effectively install such Chilled Beam system domestically, it is necessary to develop the product considering domestic climatic condition and the requirements for air conditioning system, and particularly the way to deal with condensation during operation of cooling system in summer shall be provided. In this study, the optimal design on induction structure of Chilled Beam unit was carried out through a numerical method, and the performance test for the prototype of unit was conducted in a real-scale experiment facilities of Chilled Beam unit. While the flowrate of 1st air is 101.3 CMH, the pressure in pressure chamber is 158.7 Pa and the cooling capacities of 1st air side and 2nd air side are 498.1 W and 709.5 W respectively.

공기조화기용 열교환기의 공기측 파울링 가속 특성 분석 (An experimental study of the air-side particulate fouling in finned-tube heat exchangers of air conditioners through accelerated tests)

  • 안영철;조재민;이재근;이현욱;안승표;윤덕현;강태욱;옥주호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1857-1862
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the fouling characteristics trough accelerated tests. The fouling characteristics are analyzed as functions of a dust concentration (1.28 and 3.84 $g/m^3$), a face velocity (0.5, 1.0, and 1.5 m/s), and a surface condition. The cooling capacity in the slitted finned-tube heat exchangers at the face velocity of 1 m/s decreases about 2% and the pressure drop increases up to 57%. The rate of build-up of fouling is observed to be 3 times slower for this three-fold reduction of dust concentration whilst still approaching the same asymptotic level.

  • PDF

발전소용 공랭식 응축기(ACC)의 작동조건 변화에 따른 성능특성에 대한 수치적 연구 (A Numerical Study on the Performance Characteristics of a Power Plant Air-Cooled Condenser (ACC) Affected by Changes in Operating Conditions)

  • 박경민;주기홍;박창용
    • 한국생산제조학회지
    • /
    • 제26권2호
    • /
    • pp.243-250
    • /
    • 2017
  • A numerical study was conducted to calculate the cooling capacity variation of a power plant ACC (air-cooled condenser) caused by changes in operating conditions. A numerical model was developed using the ${\varepsilon}-NTU$ and finite volume method, containing 100 elements for a single low fin tube. The model was validated through a comparison of cooling capacity between the simulated values and manufacturer's data. Even though simple assumptions and previously presented heat transfer correlations were applied to the model, the prediction error was 1.9%. The simulated variables of the operating conditions were air velocity, air temperature, and mass flux. The analysis on the variation of thermal resistance along the tube showed that the water side thermal resistance was higher than the air side thermal resistance at the downstream end of the tube, indicating that the ACC capacity could be increased by applying technology to enhance in-tube flow condensation heat transfer.

다분지 미니 채널 열교환기의 액단상 열전달 특성에 관한 연구 (A study of heat transfer characteristics on the Multi-pass Heat exchanger with Minichannel)

  • 임용빈;이승훈;김정훈;김종수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.357-362
    • /
    • 2006
  • This research focused on the multi-pass heat exchanger using the minichannel possessing the spring fin. An air-water was used as working fluid. The characteristics of liquid single phase heat transfer were verified. The compact heat exchanger (heat transfer area density : ${\beta}=2,146 m^2/m^3$), based on the shape of header(Top combining header), 63 minichannels ($D_i$ : 1.4 mm, L : 0.25 m) and the air side adopting the copper wire spring fin, was fabricated. The heat transfer area density of the air side was improved up to 161% when compared with the conventional fin-tube heat exchanger that adopts the heat transfer tube with the inner diameter of 5 mm. With regard to heat transfer performance, heat transfer rate per unit volume increased up to 142% when compared with the fin-tube heat exchanger adopting the heat transfer tube with the inner diameter of 5 mm.

  • PDF