• Title/Summary/Keyword: Air-heating

Search Result 2,329, Processing Time 0.027 seconds

Performance Analysis of Water/Air Direct Contact Air Conditioning System (물-공기 직접접촉식 공기조화장치의 성능해석)

  • 유성연;권화길;김광영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.175-183
    • /
    • 2004
  • Performance of the water/air direct contact air conditioning system, in which heat and mass are directly transferred between air and water droplet, is simulated using semi-empirical method. Direct contact system improves transport efficiency compared to conventional indirect contact system. In this study, correlations for h$_{c}$A / c$_{pm}$ which represent the capacity of direct contact system are derived as a function of air and water flowrate from the experimental data. Cooling and heating performance of the water/air direct contact air conditioning system are evaluated using these correlations.ons.

Heating and Cooling System for Utilization of Surplus Air Thermal Energy in Greenhouse and its Control Logic

  • Yang, Seung-Hwan;Lee, Chun-Gu;Lee, Won-Kyu;Ashtiani, Alireza Araghi;Kim, Joon-Yong;Lee, Sang-Deok;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • v.37 no.1
    • /
    • pp.19-27
    • /
    • 2012
  • Purpose: Utilizing air thermal energy during over-heated time in the greenhouse is a necessary component to save greenhouse heating costs for nighttime. However, there is no practical way to implement the related principles. Methods: In this study, a heating and cooling system which utilizes the surplus air thermal energy in a greenhouse was developed. Available air thermal energy and heating load for this experimental glasshouse were estimated based on temperature conditions of the plant growth and weather data. Results: Estimated values were 400 MJ/day for maximum surplus air thermal energy and 340 MJ/day for maximum heating energy which were target values of the design as well. The system consists of a heat pump, fan-coil units and heat storage tanks which are divided into low and high temperature tanks. Moreover, a new control logic was developed for surplus air thermal energy utilization. Conclusions: This paper explains the details of conceptual design process of the system. Results of test operations showed that the developed system performed the recovery and supply of the thermal energy according to design purposes.

A Study on the Dehumidification effect of Adsorbent at low Temperature (저온에서 흡착제의 제습효과에 대한 연구)

  • Lee, Min-Seok;Jeong, Yun-Ho;Lim, So-Min;Heo, Jae-Woo;Kim, Jong-Ryeol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.177-182
    • /
    • 2020
  • Interest in heat pumps is increasing as an eco-friendly and energy-saving heating method. In particular, in order to develop a heat pump capable of heating in a low-temperature area, research to prevent frost on the surface of the outdoor unit is increasing. In other words, when heating through a heat pump in a low-temperature area, a frost layer is formed on the surface of the outdoor unit, which lowers the heat transfer performance, thereby reducing the heating capacity. Therefore, in this study, an adsorption-type dehumidification system is attached to remove the moisture vapor of the air into the outdoor unit of the heat pump. It is believed that this study can suggest the most effective dehumidification method in low temperature regions. In addition, it is expected that a heat pump with high energy efficiency can be developed by attaching an adsorption dehumidifying system to the front of the outdoor unit of the heat pump.

Effects of Gas Injection on the Heating Performance of a Two-Stage Heat Pump Using a Twin Rotary Compressor with Refrigerant Charge Amount

  • Heo, Jae-Hyeok;Jeong, Min-Woo;Jeon, Jong-Ug;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.3
    • /
    • pp.77-82
    • /
    • 2008
  • For heat pumps used in a cold region, it is very important to obtain appropriate heating capacity. Several studies using a variable speed compressor and an additional heater have been performed to enhance heating capacity at low ambient temperatures. However, for outdoor temperature conditions below $-15^{\circ}C$, it is still difficult to obtain enough heating capacity above the rated value. In recent studies, the application of gas injection technique into a two-stage heat pump yielded noticeable heating performance improvement at low temperature conditions. In this study, the heating performance of a two-stage gas injection heat pump with a rated capacity of 3.5 kW was measured and analyzed by varying refrigerant charge amount and EEV opening at the standard heating condition. The heating performance of the two-stage gas injection heat pump was compared with that of a two-stage non-injection heat pump. The heating capacity and COP of the two-stage gas injection heat pump were improved by 2-10% at the optimal charging condition over those of the two-stage non-injection heat pump.

Defrosting Behavior of Fin-Tube Heat Exchanger with PTC Heating Sheet

  • Jhee, Sung;Lee, Kwan-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.29-38
    • /
    • 2001
  • In this paper, the defrosting characteristics of a PTC heating sheet is investigated by means of a defrosting heat source for the fin-tube heat exchanger in a refrigerator The defrosting characteristics of the PTC heating sheet are examined and compared with those of a conventional electric heater experimentally. It is found that the characteristics of the water draining rate with the defrosting time show a smoothly oscillating pattern when the PTC heating sheet Is used, and the drained water is completely melted. The defrosting efficiency of the PTC heating sheet is found to be about 75%, which is about 25% higher than that of the electric heater. Also, the reduction of the defrosting time and the increment of the defrosting efficiency may be obtained by improving the arrangement of the heating elements of the healing sheet. It is shown that the defrosting time of the PTC heating sheet increases linearly with the amount of frost, whereas the defrosting efficiency is nearly constant. When applying the PTC heating sheet to the refrigerating system, one should notice the fact that the defrosting performance of the PTC heating sheet may be degraded due to the repetitive operations.

  • PDF

Experimental Study on a Low-Temperature Hot Water Capillary Radiant Floor Heating System (저온온수 모세유관 바닥복사 난방시스템의 성능에 관한 실험적 연구)

  • Cho, Jinkyun;Park, Beungyong;Lee, Yongjun;Chong, Wonho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.2
    • /
    • pp.68-82
    • /
    • 2018
  • Radiant floor heating systems with capillary tubes are energy saving systems in which hot water is circulated into capillary tube with a small diameter. In this study, the heating performance of capillary tube system is investigated in an experimental study and a simulation model. The results of the study showed that, the capillary tube radiant floor heating system maintains a more stable floor surface temperature in comparison a PB pipe system. In terms of energy consumption, the capillary tube radiant floor heating system proved to be more efficient than the PB pipe heating system at $40^{\circ}C$ of low temperature hot water supply. The difference between water temperature and room temperature can be held low for heating which saves energy. Low temperature radiant floor heating system with capillary tubes have significant advantages such as health improvement, low energy cost, optimum use of heat source(boiler) and higher operational efficiency.

Development of Three-Way Proportional Control Valve and Performance Study (3방 비례제어 조절밸브 개발 및 성능 연구)

  • Lee, Jonghwa;Jung, Taeksu;Cho, Chongdu;Kim, Jooyong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.218-223
    • /
    • 2014
  • Korea District heating corp. recently give an attention to combine the district heating and supply pipes as a two pipe system that are in the present system separated with room heating and warm water supply pipe, and the two pipe system is commonly applied for heating service in European countries. In the new two pipe system, only one heat source is supplied to a house and partitioned into room heating and warm water supply by household substation. So the effective distribution of supplied heat source in accordance to user intention is very important. This paper presents the development and performance test of three-way proportional control valve for a combined heat source system in district heating. The proposed valve is controlled to partition heat source into two different directions : hot water distributor for space heating and household substation for warm water supply in response to the pressure drops of tap water caused by the user. The performance investigation is shown within 3% of error compared to the theoretical model of the three-way proportional valve and its controllability is verified.

Thermodynamic Analysis of an Absorption Heat Pump Heating System with LiBr-Water Solution (2 중효용 흡수식 히트점프의 난방 성능 해석)

  • Won, S.H.;Lee, W.Y.;Chung, H.S.
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.73-80
    • /
    • 1989
  • This paper presents as assessment based on steady-state thermodynamic analysis and computer modeling of a double effect generation absorption heating cycle for solar air-conditioning to find operating temperature ranges. The influences of component temperatures on the heating coefficients of performance and mass flow ratio have been investigated to obtain optimum operating conditions for the proposed air conditioning system. And the single and double effect absorption cycles are compared with each other over the same range of temperatures.

  • PDF

Heating and Cooling Load Evaluation Study with TAC Based BIN Data (TAC를 반영한 BIN 데이터 기반의 냉난방 부하 변화에 관한 연구)

  • Lee, Kwang Seob;Kim, Yu Jin;Min, Kyung Chon;Lee, Euy Joon;Kang, Eun Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.463-471
    • /
    • 2017
  • According to the Korea industrial standard of air conditioning systems (KS C 9306), cooling and heating loads for buildings can be calculated by using maximum and minimum temperature in BIN data. Cooling and heating loads can be determined by building set temperature and ambient temperature. Cooling and heating system capacity of buildings can be normally designed according to determined heating and cooling loads. Cooling and heating system capacity can be reduced by updated BIN data, applying TAC (Technical Advisory Committee) values. In this study, updated BIN data have been analyzed using ambient temperature of 19 areas in Korea for the last 10 years (2005~2014) provided by KMA (Korea Meteorological Administration). Building cooling and heating loads have been calculated following TAC based BIN data. As a result, designed system capacity decreased depending on applying TAC. Those were reduced as 7.1% ($100m^2$ building), 8.7% ($1,000m^2$ building) in cooling capacity, 11.7% in heating capacity when TAC 2.5% applied. And also, it is expected system initial and operating cost by decreasing system capacity.

A Study on the Evaluation of Heating-Conditioned Environment with the Size of Classroom - Focused on Inlet Temperature of Ceiling Type Air-Conditioning System - (교실 규모에 따른 난방 공조환경 평가에 관한 연구 -천장형 냉난방기의 취출온도를 중심으로 -)

  • 최정민;김용이;박효석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1035-1042
    • /
    • 2003
  • As the desire for a better condition in classroom increases, the distribution rate of warming and cooling conditioners increases. But it is known that according to the way by which the equipments put and are operated the comfortableness felt by persons who are in classroom can make a difference. Therefore, proper equipments in accordance with the size of classroom should be considered as well as operational methods when ceiling warming and cooling conditioners put. This study makes conclusions as follows through a simulation to get improvements in accordance with the size of classroom and to improve the heating performance of ceiling warming and cooling conditioners in classroom.