• Title/Summary/Keyword: Air-conditioning system

Search Result 3,315, Processing Time 0.034 seconds

Effect of the Floor on the Ventilation Performance of the Vortex Vent (바닥의 위치가 Vortex Vent의 배기성능에 미치는 영향)

  • Lee, Jin-Won;Lim, Young-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.154-158
    • /
    • 2009
  • The vortex ventilation system (VV) which uses a rotating finned swirler installed coaxially with the exhaust duct is a very effective local ventilator. VV can enhance the capture depth by a factor of 3-5 compared to the conventional exhaust hood, in the absence of any solid walls nearby. In real situations there may exist ceiling, side wall and floor, all of which can affect the flow field and suction performance by way of the no-slip condition on the walls. 3D CFD simulation was performed in order to see the effect of the floor on the capture performance of the VV. The presence of floor reduced suction flow velocity, and increased the critical rotational speed which is the rotational speed required for stable vortex formation. Flow velocity profile along the axis could be well approximated by a universal functional form when the distance from the exhaust inlet is non-dimensionalized by the distance to the floor. Capture depth, define by the distance from the exhaust inlet to a point of velocity decreased to 10% of that at the inlet, is reduced by about 10% when the floor distance is 6 times the exhaust hood diameter.

  • PDF

Numerical Study on the Evaporation Flow Phenomena of Natural Refrigerant CO2 through Small Diameter Tubes (천연냉매인 이산화탄소의 세관 유동시 발생하는 증발 유동 현상에 대한 수치해석 연구)

  • Choi, In-Su;Park, Byung-Duck
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.2
    • /
    • pp.89-96
    • /
    • 2007
  • For the environment protection, carbon dioxide as a natural refrigerant has been studied to use in an automotive air conditioning system. Hence, a numerical model has been developed to describe the evaporation phenomena of carbon dioxide flowing through very small diameter tubes. The two dimensional low-Reynolds $k-{\varepsilon}$ model was used to predict the flow phenomena of carbon dioxide in the two phase during its evaporation. Furthermore, the results obtained from the model were compared with the experiments for the validation. The heat transfer coefficient is lower, as the tube inner diameter becomes smaller. However, the amount of heat absorbed by a unit mass of carbon dioxide is greater due to more surface area. Therefore, the small diameter tube has advantage in terms of compact design of evaporator. When the inlet condition of pressure and temperature is low, the heat transfer coefficient is slightly high at the same size of tube because of the thermal properties of carbon dioxide.

  • PDF

Analysis of Discomfort Glare by Visitors' Eye-level and Illumination Angles in Museum (박물관의 조명 각도와 관람객 눈높이에 따른 불쾌적 현휘 분석)

  • Lee, Youngwoong;Kim, Sanghyun;Jo, Seongeun;Kang, Yujin;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.4
    • /
    • pp.328-333
    • /
    • 2015
  • The museum is a important place to inform the value of various antiquities and relics. The museum, founded in domestic, were increased 90% in 2013 compared to 2006, and total number of including private museums were increased more than three times over the past decade. There are installing a variety of illumination and air-conditioning system, such as the spot lighting of exhibition explanation. But the exhibition explanation should not happen to visual perception disabilities by lighting. According to ICOM (International Council of Museum), it is stipulating that the museum should not to occur glare. However, we confirmed some occurred the glare and it was lack of previous studies about prevention plan. In this study, we verified occurrence of the glare by illumination angles and visitor's eye-level. The luminance values were determined by using DSLR camera and illuminometer. As a result, when illumination angle is 90 degree, the glare did not occurred by the luminance value ratio of over 0.167 regardless of eye-level. By contrast, the angle 30 degree was appeared glare with all level. And this study was compared luminance values that obtained through experiment and surveying.

An Analysis on the Effect of the PID Controller Design Due to Performance Index (평가지표에 따른 PID 제어기 설계 영향 분석)

  • Lee, Keum-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.52-58
    • /
    • 2005
  • Among various modern control theories, PID control has been well used for several decades. PID algorithms need some tuning methods which are used for selecting PID parameters. But in some cases various kinds of performance indices are used instead of well-known tuning rules, and so variable type of performance index must be tested so that controllers, output characteristics and disturbance rejection property meet some specifications. In this paper, linear conbinational type of performance index using error signal, time, control input and robustness is used to the PID control of air conditioning system. By use of the 2 DOF PID parmeters minimizing perfromacne index controllers, output characteristics and robustness properties are analyzed. Simulations are done by use of MATLAB with Simulink.

Research on the nasal airflow and heat and mass transfer (비강 내 공기유동과 열 및 물질전달에 관한 연구)

  • Kim, Sung-Kyun;Liem, Huynh Quang;Park, Joon-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1479-1483
    • /
    • 2008
  • The three main physiological functions of nose are air-conditioning, filtering and smelling. Knowledge of airflow characteristics in nasal cavities is essential to understand the physiological and pathological aspects of nasal breathing. Several studies have utilized physical models of the healthy nasal cavity to investigate the relationship between nasal anatomy and airflow. In our laboratory, there have been a series of experimental investigations on the nasal airflow in normal and deformed nasal cavity models by PIV under both constant and periodic flow conditions. In this time, airflow inside normal nasal cavity is investigated numerically by the FVM general purpose code. The comparisons with PIV measurement are appreciated. Heat and humidity transfer is dealt numerically. Dense CT data and careful treatment of model surface under the ENT doctor’s advice provide more sophisticated cavity models for both PIV experiment and numerical grid system. Average and RMS velocity distributions have been obtained for inspirational and expirational nasal. Temperature distribution, heat and humidity transfer through the mucosa are obtained.

  • PDF

The Flow Characteristics of Pressure Control Valves for Natural Refrigerants (천연 냉매용 압력제어밸브의 유동특성 평가)

  • Kang, Hyo-Lim;Park, Hyung-Joon;Kim, Ga-Eun;Han, Seung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.3
    • /
    • pp.51-56
    • /
    • 2020
  • Research into natural refrigerants that use CO2, instead of chlorofluorocarbons and hydrofluorocarbons, has increased due to the environmental problems caused by ozone depletion. CO2 refrigerants are more environmentally friendly than conventional refrigerants because they have better latent heat of evaporation and heat transfer efficiency properties. However, they have very low critical temperatures and require high design pressures; therefore, pressure control valves, which reduce the pressure of the CO2 refrigerant to a safe level and apply it to the refrigerant air conditioning system, are necessary to secure stability against high pressure. In the present study, we evaluated the flow characteristics and valve performance of the pressure control valve using a CO2 refrigerant by measuring the pressure, velocity, and flow coefficient. In addition, we examined the applied forces caused by the internal pressure from the highly pressurized CO2 refrigerant and required thrust characteristics.

Long-Term Maximum Power Demand Forecasting in Consideration of Dry Bulb Temperature (건구온파를 오인한 장기최대전력수요예측에 관한 연구)

  • 고희석;정재길
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.10
    • /
    • pp.389-398
    • /
    • 1985
  • Recently maximum power demand of our country has become to be under the great in fluence of electric cooling and air conditioning demand which are sensitive to weather conditions. This paper presents the technique and algorithm to forecast the long-term maximum power demand considering the characteristics of electric power and weather variable. By introducing a weather load model for forecasting long-term maximum power demand with the recent statistic data of power demand, annual maximum power demand is separated into two parts such as the base load component, affected little by weather, and the weather sensitive load component by means of multi-regression analysis method. And we derive the growth trend regression equations of above two components and their individual coefficients, the maximum power demand of each forecasting year can be forecasted with the sum of above two components. In this case we use the coincident dry bulb temperature as the weather variable at the occurence of one-day maximum power demand. As the growth trend regression equation we choose an exponential trend curve for the base load component, and real quadratic curve for the weather sensitive load component. The validity of the forecasting technique and algorithm proposed in this paper is proved by the case study for the present Korean power system.

  • PDF

Effects of Baffle Location on the Performance of a Super Compact Condenser in an Automotive Air Conditioning System (자동차용 에어컨의 고밀도 응축기(SCC)에서 배플의 위치 변화에 따른 성능향상에 관한 연구)

  • 이명재;박복춘;백병준;염동석;한창섭
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.128-140
    • /
    • 1997
  • A new super compact condenser(SCC), which has been developed recently is especially suitable for an alternative refrigerant HFC-134a due to its high performance and compactness. The SCC is composed of two pipe headers, baffles, narrow multi-rectangular channels, and louvered fin arrays. Alternating inlet and outlet by the inserted baffles in pipe headers guide refrigerant to and from the narrow multi-rectangular channels. Since the flow rate and its lengh are changed depending on the number and location of baffles, the corresponding pressure drop and heat transfer rate are changed. The present study aims to theoretically and experimentally investigate the effects of baffle location and its number on the pressure drop and thermal performance of the SCC with 40 multi-rectangular channels. The results show that the present method provides an acceptable prediction of pressure drop and heat transfer rate for a 4 pass SCC. However, the model significantly under predicts the performance of a 3 pass SCC, which may be attributed to the phase separation of refrigerant flowing through header pipes. Pressure drop is more signifi- cantly influenced than heat transfer rate by the baffle location.

  • PDF

A Case Study of Electric Power Consumption Characteristics in University Building (대학건물의 에너지 소비 특성에 관한 사례분석)

  • Lee, Wang-Je;Lee, Dong-Won;Lee, Jae-Bum;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.90-95
    • /
    • 2012
  • Of school buildings, university building requires various case analysis unlike buildings in the elementary, middle and high schools in accordance with its characteristic for variables such as characteristic of department, construction structure and material, the number of persons admitted and schedule. Through the case research on the 'D' university located in Daejeon, this study made a comparison on the monthly and yearly consumption of gas and electricity of the most recent 3 years and implemented analysis on the usage pattern and standby power of air conditioning and heating by the hour and month using PCCS(Power Consumption Consulting System) as respects electricity that is considered to have a possibility of energy-saving. The result of analysis showed that enormous amount of electric power was used during the night time for freeze protection and burst in winter season and standby power was increased in winter season as a result.

A World Trend of Hydrogen Energy Policy and Patent Analysis on the Hydrogen Compressor (수소 에너지 정책의 세계동향 및 수소 압축기의 특허분석)

  • Shim, Kyu-Jin;Kong, Tae-Woo;Lee, Yong-Hun;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.179-185
    • /
    • 2005
  • Nowadays, study about hydrogen fuel which consist of hydrogen extraction process, reforming, fuel cell equipment, and receptacle are flourish all over the world. Currently, Korea hydrogen station is still underdevelopment. Yet the most important part such as hydrogen compressor has not been develop. Therefore, if the high pressure compressor for hydrogen have been developed by domestic technology. In the future many benefit can be gain instead of importing. Such as many hydrogen station can be built in Korea, and also Korea will be able to provide hydrogen system for worldwide. This study is going to analysis hydrogen compressor in order to store high pressure hydrogen. This is almost approach practical use of tile hydrogen storage method.

  • PDF