• 제목/요약/키워드: Air-conditioner

Search Result 778, Processing Time 0.026 seconds

Efficient Control of an Air Conditioner Using Thermal Image and a Fuzzy Control Method (퍼지 제어 기법과 열 영상을 이용한 에어콘의 효율적 제어)

  • Kim, Kwang-Baek;Woo, Youn-Woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2201-2206
    • /
    • 2010
  • The shortage of fossil fuel drives researchers to find a new way to increases energy efficiency. In this paper, we propose a method to control the direction and speed of an air conditioner using a thermal image and fuzzy controlling method, which results in the increase of energy efficiency. The thermal image is first converted into a color temperature image which represents the temperature range from $24.0^{\circ}C$ to $27.0^{\circ}C$. The temperature image is divided into 5 columns and the distribution of them is used to analyze room temperature and control an air conditioner. The proposed method was applied to 300 by 400 thermal images. When the performance of the proposed method was compared to existing systems in energy efficiency, the proposed method was better than existing methods, which is clear from experimental results.

PERFORMANCE ASSESSMENT OF THE RANS TURBULENCE MODELS IN PREDICTION OF AERODYNAMIC NOISE FOR AIR-CONDITIONER INDOOR UNIT (에어컨 실내기의 공력소음 예측을 위한 RANS 난류모델의 성능 평가)

  • Min, Y.H.;Kang, S.;Hur, N.;Lee, C.;Park, J.
    • Journal of computational fluids engineering
    • /
    • v.17 no.4
    • /
    • pp.81-86
    • /
    • 2012
  • The objective of the present study is to investigate the effects of various turbulence models on the aerodynamic noise of an air-conditioner (AC) indoor unit. The results from URANS (unsteady Reynolds-averaged Navier-Stokes) simulations with the standard k-$\varepsilon$, k-$\omega$ shear stress transport (SST) and Spalart-Allmaras (S-A) turbulence models were analyzed and compared with the noise data from the experiments. The frequency spectra of the far-field acoustic pressure were computed using the Farrasat equation derived from the Ffowcs Williams-Hawkings (FW-H) equation based on the acoustic analogy model. Two fixed fan casings and the rotating cross-flow fan were used as the source surfaces of the dipole noise in the Farrasat equation. The result with the standard k-$\epsilon$ model showed a much better agreement with the experimental data compared to the k-w SST and S-A models. The differences in the pressure spectra from the different turbulence models were discussed based on the instantaneous vorticity fields. It was found that the over-estimated power spectra with the k-w SST and S-A models are related to the emphasized small-scale vortices produced with these models.

AC-DC Converter Control for Power Factor Correction of Inverter Air Conditioner System (인버터 에어컨 시스템의 역률보상을 위한 AC-DC 컨버터 제어)

  • Park, Gwi-Geun;Choi, Jae-Weon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.154-162
    • /
    • 2007
  • In this paper, we propose a new AC-DC converter control method to comply with harmonics regulation(IEC 61000-3) effective for the inverter system of an air conditioner whose power consumption is less than 2,500W. There are many different ways of AC-DC converter control, but this paper focuses on the converter control method that is adopting an input reactor with low cost silicon steel core to strengthen cost competitiveness of the manufacturer. The proposed control method controls input current every half cycle of the line frequency to get unit power factor and at the same time to reduce switching loss of devices and acoustic noise from reactor. This kind of converter is known as a Partial Switching Converter(PSC). In this study, theoretical analysis of the PSC has been performed using Matlab/Simulink while a 16-bit micro-processor based converter has been used to perform the experimental analysis. In the theoretical analysis, electrical circuit models and equations of the PSC are derived and simulated. In the experiments, micro-processor controls input current to keep the power factor above 0.95 by reducing the phase difference between input voltage and current and at the same time to maintain a reference DC-link voltage against voltage drop which depends on DC-link load. Therefore it becomes possible to comply with harmonic regulations while the power factor is maximized by optimizing the time of current flow through the input reactor for every half cycle of line frequency.

The Design of the Motor Bracket for Reduction of Structure- Borne Noise in Package Air-Conditioner (에어컨의 구조 소음 저감을 위한 실내기 모터 브라켓의 설계)

  • Sim Hyoun-Jin;Lee Sung-Jin;Kang Tae-Ho;Lee Jung-Yoon;Oh Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.2 s.245
    • /
    • pp.202-209
    • /
    • 2006
  • As the economic power is improved and the customer's demand is hard to please, the noise and vibration is the most important yardstick that can determine the quality of the product. Especially, as the airconditioner's demand increase suddenly, the product of quality and the noise is becoming a decisive factor of determining whether purchase the product or not. Therefore, every manufactory is investing a lot of money and research to cut down the unpleasantness induced from noise and vibration. And they are emphasizing their product's difference by advertising a silence very actively. With these reason, the demand of a silent indoor air-conditioner is the essential research filed when the product is develop(:d. In this study, the noise and vibration is visualized in the space and frequency domain by using experimental methods such as operational deflection shape (ODS), modal testing and sound intensity. Also the location of noise source and its characteristic is analyzed in an acoustical point of view to reduce the structure borne noise that come from the fan motor, and the pertinent control method is suggested. Furthermore, the most suitable shape of the motor bracket is suggested by applying FEM and DOE (Design of experiments) in the noise and vibration point a view.

Analysis of relative contribution of machinery-induced vibration/flow-induced vibration to noise radiation from compressor discharging piping system in air-conditioner outdoor unit (에어컨 실외기 압축기 배기 배관계의 기기 기인 진동/유동 기인 진동의 방사소음에 대한 상대적 기여도 분석)

  • Sangheon Lee;Cheolung Cheong;Jinhyung Park;Jangwoo Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.122-130
    • /
    • 2024
  • Vibration of compressor in the air-conditioner outdoor unit have known to be main noise source radiated from outdoor unit. However, as the operating speed of compressor increase, the relative contribution of flow induced vibration and noise is also increase. In this paper, the numerical method was established to predict fluid-borne noise from compressor discharging pipe of air-conditioner outdoor unit. In this step, numerical result was compared to experimental one to verify numerical method. Additionally, the effects of pressure pulsation of compressor and compressor vibration into radiated noise were investigated in frequency domain. It was confirmed that the compressor vibration contributed to the low frequency band, while the pressure pulsation dose to the high frequency band.

Measurement of Indoor Air Quality for Ventilation with the Existence of Occupants in Schools

  • Shin Hee-Soo;Lee Jai-Kwon;Ahn Young-Chull;Yeo Chang-Shin;Byun Sang-Hyun;Lee Jae-Keun;Kang Tae-Wook;Lee Kam-Gyu;Park Hyo-Soon
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.1001-1005
    • /
    • 2005
  • This paper evaluates the performance of ventilation for the removal of indoor pollutants as a function of ventilation rate and the number of occupants in a test room and school classroom. An experimental apparatus consists of a test room, a tracer gas supply system, a gas detector, and a fan for ventilation air supply with a controller. The ventilation performance is evaluated in a step-down method based on ASTM Standard E741-83 using $CO_{2}$ gas as a tracer gas in the test room of 35 $m^{3}.$ For the ventilation air flow rate of 1.0 ACH, a recommended ventilation flow rate of Korea school standard for acceptable indoor air quality in the case of one person, CO_{2}$ gas concentration decreases up to $55{\%}$ within 50 minutes without occupancy and increases up to $75{\%}$ in the case of one occupant. Also indoor air quality at the school classroom is investigated experimentally.

Optimization of flow performance by designing orifice shape of outdoor unit of air-conditioner (에어컨 실외기 냉각팬 시스템의 오리피스 형상 설계를 통한 유량 성능 최적화)

  • Ryu, Seo-Yoon;Kim, Sanghyeon;Cheong, Cheolung;Kim, Jong-Uk;Park, Byeong Il;Park, Se Min
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.6
    • /
    • pp.371-377
    • /
    • 2017
  • The performance of an air conditioner is closely related to the cooling performance of a split-type outdoor unit so that, in most of the relevant preceding studies, the independent performance of an axial fan in an outdoor unit has been studied. However, there is a lack of research on the effects of other components in an outdoor units was rarely investigated. Therefore, in this paper, the effects of the fan orifice among other parts on the flow performance of the outdoor unit was numerically investigated. A virtual fan tester consisting of 18 million grids was developed for highly resolved flow simulation. The unsteady RANS (Reynolds-averaged Navier-Stokes) equations are numerically solved by using finite-volume CFD (Computational Fluid Dynamics) techniques. In order to verify the validity of the numerical methods, the predicted P-Q curve of the cooling fan in a full outdoor unit is compared with the measured one. Optimization of orifice shape was carried out for maximum flow performance of the outdoor unit using the validated numerical method.