• 제목/요약/키워드: Air-borne noise

검색결과 107건 처리시간 0.029초

깃 끝단 개선을 통한 냉장고용 축류홴 저소음화에 대한 연구 (Study on Noise Reduction of an Axial Fan for Refrigerator through Modification of the Blade Tip)

  • 김창준;전완호;정용규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.639-644
    • /
    • 2002
  • In this paper, a successful noise reduction of an axial flow fan for a refrigerator is presented. The vortex sheet generated at the blade tip of fan was suppressed by changing the shape of the tip. The structure of vortex sheet and detailed flow pattern around the fan were studied by two-dimensional LDV(Laser-Doppler Velocimetry). Effective ways to work out the result as mentioned above are to make the tip of the blade varied in thickness and to have elliptical shapes. To seek the optimal value fur the shape of new fan, several cases were examined. Through the application of the methods, the refrigerator became less noisy by 3.8 dB(A) in terms of air-borne noise produced only by the axial flow fan compared to the current one.

  • PDF

고체음원의 출력 예측방법에 대한 연구 (A Method to determine structureborne noise levels from machineries)

  • 김상렬;김재승;김현실;강현주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.545-550
    • /
    • 1997
  • It is well known that Statistical Energy Analysis(SEA) is one of very attractive analytical methods to solve shipboard noise problems. With reasonable successes, many applications of SEA to shipboard noise prediction have been reported. However when one wishes to obtain theoretical predictions by using SEA in practical systems, he will find difficulty in modeling of source systems, that is, foundations where to place main engine, generator, compressor, and so on. Also, he will find that it is hard to determine the amount of power flow from machinery to structures. In this paper, SEA of a simple foundation model was carried out using the estimated amount of power flow from source; the estimated mobility method. The comparison between the estimated and measured results is presented. That comparison shows a method to get structure-borne noise power from the combination of machinery and foundation. This prediction method gave a good results for a air-compressor mounted on a model foundation. The method is expected to give a reasonable power output in practical problems.

  • PDF

소음원간 누화 효과에 대한 수학적 모델 및 전달 경로 분석법 비교를 통한 검증 (The Mathematical Model on Crosstalk Effect of Airborne Noise Sources and Verification based on Comparison between Transfer Path Analysis Methods)

  • 변재환;김윤재;강연준;강구태;권오준;홍진철
    • 한국소음진동공학회논문집
    • /
    • 제18권9호
    • /
    • pp.943-951
    • /
    • 2008
  • In this paper, the mathematical model on crosstalk effect between acoustic noise sources is presented. Based on this model, a theoretical value to quantitate crosstalk effect of sources can be defined on the authority of reverberation property of surrounding which sources are located, relative magnitudes of sources and phase deference between acoustic wave transferred from all of sources. In order to verify crosstalk effect factor, experiments are made for two cases, weak and strong crosstalk effect condition, by using toro representative transfer path analysis(TPA) methods.

소형 승용차량의 SEA 모델링 및 내부 소음 연구 (A SEA Modeling of a compact car and Interior Noise Analysis)

  • 김상수;김관주;임효석;김영호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.824-828
    • /
    • 2007
  • In this paper Statistical Energy Analysis has been considered to predict middle, high frequency air borne interior noise. PIM method is used for verification. Damping loss factor and coupling loss factor have been derived from the response(SPL) of sub systems when the power is applied. The airborne SEA model of vehicle is modeled through AutoSea2. Insulation material's absorption coefficient and transmission loss are acquired from closed form solution and experiment.

  • PDF

유체기인 방사소음 저감용 소음기 개념설계 이론 (CONCEPT DESIGN THEORY OF SHOCK ABSORBING MUFFLERS FOR AIR-BORNE NOISE)

  • Kim, Sang-Myeong
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.627-632
    • /
    • 2002
  • The paper considers acoustic analysis of the shock absorbing muffler within a rotary compressor. The internal space of the compressor is modelled as a combination of cavities and pipes. A simple one-dimensional impedance approach is used fur the acoustic analysis in the low frequency range, with ignoring the effects of gas flow and temperature gradients that are closely related to power efficiency of the compressor. Using the similarity between the vibration isolator and the shock absorbing muffler, the source strength transmissibility is newly proposed as a performance measure of the muffler and its validity is supported by power analysis. Some Important muffler design rules obtained are; (1) a muffler cavity and its opening throat should be used as a pair, (2) a long thin throat is desirable for high frequency noise isolation, (3) a large muffler cavity should be used with care since it shortens the working frequency range of the muffler. The rules were applied to redesign a compressor muffler currently in use, and a significant improvement was achieved by simply attaching a throat to the outlet holes of the muffler.

  • PDF

선박의 장비 공기소음이 수중소음에 미치는 영향 (Effect of Airborne Noise from Ship Machinery on Underwater Noise)

  • 김현실;김재승;김봉기;김상렬;이성현
    • 대한조선학회논문집
    • /
    • 제48권6호
    • /
    • pp.569-574
    • /
    • 2011
  • In research vessels or naval ships, airborne noise from machineries such as diesel engine is the major source of underwater noise at low speed. In this paper, effect of engine noise on underwater noise is studied by considering two paths; sound radiation from hull plate and direct airborne noise transmission through hull plate. SEA (Statistical energy analysis) is used to predict hull plate vibration induced by engine noise, where SEA model consists of only two subsystems; engine room air space and hull plate. The pressure level in water is calculated from sound radiation by plate. Engine noise transmission through hull plate is obtained by assuming plane wave propagation in air-limp plate-water system. Two effects are combined and compared to the measurement, where speaker is used as a source in engine room and sound pressure levels in engine room and water are measured. The hydrophone is located 1 m away from the hull plate. It is found below 1000 Hz, prediction overestimates underwater sound pressure level by 5 to 12 dB.

Wire Mounting을 이용한 진동저감에 대한 실험 연구 (Vibration Reduction Using Wire Mounting - Test Results)

  • 최상현;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.403-408
    • /
    • 2001
  • Structure-borne noise and vibration is one of the main complaints of home appliances such as refrigerators, washing machines, air conditioners, etc. There have been many efforts to reduce the emitting noise and vibration. Mostly the efforts have been concentrated to optimize the mounts shape and its material properties realizing that the vibration power is mainly transmitted to the structure via mounts. It is known that softer mounts have the better vibration isolation effect. But mounts have another important function in addition to the vibration isolation. That is to support the motor and compressor safely. Thus mounts should be stiff enough to resist the supporting items. But the two properties, stiff and soft, are contradict each other. So the designer should compromise the two complicity properties properly in between. Noticing that, motors and compressors themselves are very quite until they are connected to the base structure via mounts, wire connecting idea was proposed in this work. Instead of using conventional mounts, as shown in Fig 4, compressor was mounted using six wires as shown in Fig 5. Since wire is very flexible in bending but stiff in tension, we can realize the ideal mount design requirements, stiff enough to support and soft enough to isolate vibration power. The suggesting idea was tested with an air conditioner outdoor unit.

  • PDF

청감실험을 통한 생활소음의 평가척도 및 기준 설정 (Development of Noise Annoyance Scale and Criteria of Residential Noises through Auditory Experiments)

  • 류종관;전진용;김흥식
    • 한국소음진동공학회논문집
    • /
    • 제15권8호
    • /
    • pp.904-910
    • /
    • 2005
  • A 7-point verbal noise annoyance scale for residential noises was developed in this study. An auditory experiment using major residential noises such as air-borne, bathroom drainage, and traffic noises was conducted to develop a noise annoyance scale for rating residential noises and allowable limit of them. The modifiers used in the scales were selected according to the method proposed by ICBEN(international commission on the biological effect of noise) Team 6. Results showed that the intensity of the selected words in the 7-point noise annoyance scale was highly correlated with noise levels. and that the intensity difference between each pair of successive levels in the 7-point annoyance scale was almost identical. The allowable limit of residential noise was also investigated in the auditory experiment and that of airborne, drainage and traffic noises were 42.3 dB(A), 41.0 dB(A) and 42.7 dB(A), respectively.

SEA 기법을 이용한 저중량 대시판넬 흡,차음재 성능에 대한 연구 (Acoustic Study of light weight insulation system on Dash using SEA technique)

  • 임효석;박광서;김영호;김인동
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.51-55
    • /
    • 2007
  • In this paper Statistical Energy Analysis has been considered to predict high frequency air borne interior noise. Dash panel Insulation is major part to reduce engine excitation noise. Transmission loss and absorption coefficient are considered to predict dash insulation performance. Transmission lose is derived from coupling loss factor and absorption coefficient is derived from internal damping loss factor. Material Biot properties were used to calculate each loss factors. Insulation geometry thickness distribution was hard to measure, so FeGate software was used to calculate thickness map from CAD drawing. Each predicted transmission losses between conventional insulation and light weight insulation were compared with SEA. Transmission loss measurement was performed to validate each prediction result, and it showed good correlation between prediction and measurement. Finally interior noise prediction was performed and result showed light weight insulation system can reduce 40% weight to keep similar performance with conventional insulation system, even though light weigh insulation system has lower sound transmission loss and higher absorption coefficient than conventional system.

  • PDF

공 회전시 자동변속기 차량의 실내소음 음질 개선에 관한 연구 (A Study on the Improvement of the Sound Quality of the Interior Noise of A/T Vehicle in Idle State)

  • 이상권;최병욱;여승동
    • 한국자동차공학회논문집
    • /
    • 제1권1호
    • /
    • pp.110-119
    • /
    • 1993
  • 본 논문은 자동변속기를 탑재한 차량에서 에어콘(air condition)을 작동시키고, 공 회전시 기어의 변속을 "D"단에 두었을 때 실내에서 발생하는 이상음의 원인규명 및 해결 방 법에 관한 연구 결과를 논하고자 한다. 이 이상한 소음의 원인을 규명하기 위하여 실린더 내부의 연소압력, 메인 베어링캡(main bearing cap)의 진동, 엔진 마운팅 보스의 진동 및 차 량의 실내소음을 동시에 측정하여 분석하였으며 이 결과에 의하면 이상음의 원인은 크랭크 샤프트(crank shaft)의 굽힘진동이 파워플랜트(power plant)를 가진하여 진동을 증가시키고, 이 진동이 마운팅 보스를 통하여 차량의 차체에 전달되며, 차체의 진동에 의해서 발생하는 고체 전달음(structure-borne noise)이었다. 또한 이상음의 주기는 주파수 성분은 200-400Hz 이었다. 이 이상음은 크랭크 샤프트의 댐퍼 풀리의 질량을 저감하여 크랭크 샤프트의 동특 성을 개선함으로서 해결가능하고, 혹은 점화시기를 지연하여 연소 압력을 낮춤으로서 해결 가능하다.

  • PDF