• 제목/요약/키워드: Air-borne

검색결과 235건 처리시간 0.03초

구조 인텐서티법을 이용한 에어컨 실외기의 제진재 적용 (Damping Patch Placement on Outdoor Unit of Air-conditioner by Using Structural Intensity Technique)

  • 김규식;진심원;정인화;이정우;강연준
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.577-585
    • /
    • 2004
  • In this paper, reactive shearing structural intensity method is extended to damping patches placement on outer panels of outdoor unit of air-conditioner to reduce its structural borne noise. The structural intensity is calculated from the normal velocities of structures that are measured by using a laser scanning vibrometer, and $textsc{k}$-space (wave-number domain) signal processing is used to obtain the spatial derivatives in formulation of structural intensity. This method is applied to the outdoor unit of air-conditioner on shaker-exciting mode and operating mode. and then damping patches are placed over area of high reactive shearing structural intensity for reducing the radiated noise. Experimental results show the largest reduction of sound pressure level of an outdoor unit by appling small damping patches to optimal position.

에어컨의 구조 소음 저감을 위한 실내기 모터 브라켓의 설계 (The Design of the Motor Bracket for Reduction of Structure-Borne Noise in Package Air-Conditioner)

  • 심현진;김성현;강태호;이정윤;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.453-456
    • /
    • 2005
  • In recent years, the demand of a silent indoor air-conditioner is the essential research filed when the product is developed. In this study, through the design modification of the noise and vibration source, the noise and vibration level of the package air-conditioner is reduced. The modal analysis of the motor bracket is performed by FEM. To find the most suitable shape of the motor bracket, Design of Experiments is applied.

  • PDF

HEPA Filter를 이용한 미세입자 거동에 관한 연구 (A study on the Behavior of Fine Particle used the HEPA Filer)

  • 김원강
    • 환경위생공학
    • /
    • 제24권3호
    • /
    • pp.16-27
    • /
    • 2009
  • In this paper, I examined the level of fine dust in medical institutions, educational institutions and multi-purposed facilities to grasp the exact state of the present, and decided the level of air-borne particulate(KSM ISO Standard and ISO Standard 14644-1). We compared new proposed cleaner equipped with HEPA Filter with general cleaner and analyzed the rate of removal according to height, air volume and the equipment with the compulsive air intake. Through this comparison, I reached the conclusion as follows: 1. According to the examination, the fine dust of medical institutions, educational institutions and multi-purposed facilities in Kwang Ju is class 9. 2. The filter used in general cleaner on the market is that of HEPA-type, and its removal efficiency for fine particles($0.3{\sim}0.5{\mu}m$) is very low. 3. In the removal efficiency of new proposed cleaner equipped with HEPA Filter, the higher it is, the better, especially more than 180cm in height. 4. In case it is operated for 5 minutes under the condition of the space of $9.4m^{3}$ and the maximum air volume equipped with two induction pipes, we can keep the air cleanness level of 5 ~ 6. 5. To maintain the air cleanness for a long time, if we first operate for 5 minutes at maximum air volume and then operate at medium maximum air volume, we can keep the air cleanness with low energy.

실내 미생물오염 전파방지를 위한 멀티존 모델링에 관한 연구 (A Study on the Multizone Modeling for Preventing Transmission of Air Borne Contagion)

  • 최상곤;이현우;홍진관
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.933-940
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 developed by NIST is used for estimating the air disinfection rate of the interior of a room which is set up the indoor air disinfection system with filter and ultra violet germicidal irradiation (UVGI). Developed models those enable to predict the transmission of air home contagion such as bacteria and fungus generated in our daily life are useful model for designning air cleaning & ventilation system of building. Also, results indicate that these models are enable to compute the real situation that is almost impossible of carrying out experiment in an actual condition due to biohazard problems and suggest that engineers will use these models as a design tool for the future immune building system.

시판생식의 제조공정 및 최종제품의 미생물분포 (Microflora of Manufacturing Process and Final Products of Saengshik)

  • 장태은;문성양;이건욱;백장미;한정수;송옥자;신일식
    • 한국식품과학회지
    • /
    • 제36권3호
    • /
    • pp.501-506
    • /
    • 2004
  • 생식제품의 미생물학적 안전성을 확보를 위한 기초 자료로 활용하고자 생식제품 및 제조 공정 중에 있어서 Bacillus cereus, Clostridium perfringens, Staphylococus aureus 등 식중독세균을 중심으로 한 자연 환경 유래 위해미생물의 분포 및 주 오염공정을 조사하였다. 생식 원료 중 위해미생물의 검출율이 높은 원료는 주로 곡류이었으며, 원료를 일반수도수로 세척하고 동결건조 하여도 위해미생물은 완전히 제거되지 않아 원료에 대한 비가열살균 대책이 필요할 것으로 사료된다. 한편 최종제품의 위해미생물의 검출율이 원료보다 높게 나타나 제조공정 중 미생물 오염이 증가하는 것을 알 수 있었으며 위해미생물은 원료의 1차 분쇄 후 공정이 진행됨에 따라 증가하였고, 특히 외주분말(하청공장에서 원료를 세척, 건조, 분쇄한 것)을 혼합한 후 균수가 급속히 증가하였다. 공중부유균은 분쇄실과 혼합실에서 많이 검출되었으며, 생식 제조 공정에 사용되는 기계 및 기구에서도 위해미생물이 검출되어 공중부유균과 기계 및 기구의 오염, 그리고 기계에 끼여 있는 분말 찌꺼기가 제조공정 중 생식의 미생물 오염 원인이라는 것을 알 수 있었으며, 따라서 공중부유균의 살균대책 및 하청공장의 철저한 위생관리가 요구되며, 분쇄기 및 혼합기의 정기저인 소독 및 살균이 필요 할 것으로 사료된다.

Vertical Change in Extinction and Atmospheric Particle Size in the Boundary Layers over Beijing: Balloon-borne Measurement

  • Chen, Bin;Shi, Guang-Yu;Yamada, Maromu;Zhang, Dai-Zhou;Hayashi, Masahiko;Iwasaka, Yasunobu
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권3호
    • /
    • pp.141-149
    • /
    • 2010
  • Aerosol size and number concentration were observed in the atmospheric boundary layer over Beijing (from near the ground to 1,200 m) on March 15 (a clear day) and 16 (a dusty day), 2005. The results were further compared with lidar measurements in order to understand the dependency of extinction on the particle size distribution and their vertical changes. The boundary layer atmosphere was composed of several sub-layers, and a dry air layer appeared between 400 and 1,000 m under the influence of dust event. In this dry air layer, the concentration of the fine-mode particles (diameter smaller than $1.0\;{\mu}m$) was slightly lower than the value on the clear day, while the concentration of coarse-mode particles (diameter larger than $1.0\;{\mu}m$) was remarkably higher than that on the clear day. This situation was attributed to the inflow of an air mass containing large amounts of Asian dust particles and a smaller amount of fine-mode particles. The results strongly suggest that the fine-mode particles affect light extinction even in the dusty atmosphere. However, quantitatively the relation between extinction and particle concentration is not satisfied under the dusty atmospheric conditions since laser beam attenuates in the atmosphere with high concentration of particles. Laser beam attenuation effect becomes larger in the relation between extinction and coarse particle content comparing the relation between extinction and fine particle content. To clarify this problem technically, future in situ measurements such as balloon-borne lidar are suggested. Here extinction was measured at 532 nm wavelength. Measurements of extinction at other wavelengths are desired in the future.

에어컨의 구조 소음 저감을 위한 실내기 모터 브라켓의 설계 (The Design of the Motor Bracket for Reduction of Structure- Borne Noise in Package Air-Conditioner)

  • 심현진;이성진;강태호;이정윤;오재응
    • 대한기계학회논문집A
    • /
    • 제30권2호
    • /
    • pp.202-209
    • /
    • 2006
  • As the economic power is improved and the customer's demand is hard to please, the noise and vibration is the most important yardstick that can determine the quality of the product. Especially, as the airconditioner's demand increase suddenly, the product of quality and the noise is becoming a decisive factor of determining whether purchase the product or not. Therefore, every manufactory is investing a lot of money and research to cut down the unpleasantness induced from noise and vibration. And they are emphasizing their product's difference by advertising a silence very actively. With these reason, the demand of a silent indoor air-conditioner is the essential research filed when the product is develop(:d. In this study, the noise and vibration is visualized in the space and frequency domain by using experimental methods such as operational deflection shape (ODS), modal testing and sound intensity. Also the location of noise source and its characteristic is analyzed in an acoustical point of view to reduce the structure borne noise that come from the fan motor, and the pertinent control method is suggested. Furthermore, the most suitable shape of the motor bracket is suggested by applying FEM and DOE (Design of experiments) in the noise and vibration point a view.

에어컨 실외기 압축기 배기 배관계의 기기 기인 진동/유동 기인 진동의 방사소음에 대한 상대적 기여도 분석 (Analysis of relative contribution of machinery-induced vibration/flow-induced vibration to noise radiation from compressor discharging piping system in air-conditioner outdoor unit)

  • 이상헌;정철웅;박진형;이장우
    • 한국음향학회지
    • /
    • 제43권1호
    • /
    • pp.122-130
    • /
    • 2024
  • 에어컨 실외기 내부의 압축기 진동 소음은 실외기에서 발생하는 소음의 주 원인으로 인식되고 있었다. 하지만, 압축기의 작동 속도가 증가함에 따라 압축기에 연결된 배관계에서의 냉매 유동 기인 진동에 의한 소음의 상대적 기여도가 증가하였다. 본 논문에서는 에어컨 압축기 배기 배관계에서의 유체 기인 소음을 수치적으로 예측할 수 있는 해석방법을 정립하였다. 이 단계에서, 해석 결과와 실험결과의 비교를 통해 해석의 신뢰성을 확인하였다. 추가적으로, 압축기 배기 배관계 방사 소음에 대하여 압축기 맥동음과 압축기 진동에 의한 소음의 영향을 주파수 대역별로 비교하였다. 압축기 진동에 의한 소음이 저주파수 대역에 기여함을 확인하였으며, 압축기 맥동음이 고주파수에서의 소음에 영향을 줌을 확인하였다.

에어컨 실외기 프로펠러 홴계의 진동소음 평가 및 해석 (Noise & Vibration Evaluation and Analysis for Propeller Fan System of Air Conditioner Outdoor Unit)

  • 박득용;모진용;이진교;구형모;최원석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1405-1409
    • /
    • 2000
  • The electro-magnetic noise generated from fan-driving motor is one of important items in view of abnormal noise which affect the quality of air conditioner noise. The electro-magnetic noise of the outdoor unit is identified by the serial experiments for related parts, whose effects are verified to give proper measures for reduced noise level. The weight of fan appears to be the most important factor, and the stiffness of the frame, such as motor bracket is shown to be important also.

  • PDF

자동차 타이어 패턴 소음 예측에 따른 차량 Road Noise 실험적 평가 (An Experimental Evaluation for Vehicle Road Noise on the Pattern Noise Prediction)

  • 왕성준;이근수;김인동
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.361-364
    • /
    • 2011
  • In this paper, This work demonstrates a experimental evaluation for vehicle road noise NVH performance from the component-level NVH measurements of Tire. The power unit noise from tire emitted by cars has been reduced. It has been found that tire noise dominates noise produced by the power train when vehicles are driven at high constant speed. Therefore tire pattern noise is affected by pattern and vehicle and transmission loss. Tire noise mechanism is generated by several mechanisms. The sound of tire can propagate either through the air or through the structure of vehicle. Pattern noise is the result of pressure variations through the air to the interior side of vehicle. Especially, smooth asphalt, the periodicity of tread design, groove depth is important factor, which have an influence on the reduction of tire pattern noise.

  • PDF