• 제목/요약/키워드: Air-Surface exchange

검색결과 108건 처리시간 0.032초

지열 시스템의 도입이 지중온도환경에 미치는 영향에 대한 해석적 검토 (Numerical Analysis of the Effect of Ground Source Heat Pump Systems on the Underground Temperature)

  • 남유진
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.427-431
    • /
    • 2013
  • Ground heat pump systems utilize the annually stable underground temperature to supply heat for space heating and cooling. The underground temperature affects not only the underground ecosystem, but also the performance of these systems. However, in spite of the widespread use of these systems, there have been few researches on the effect of the systems on underground temperature. In this research, case studies with numerical simulation have been conducted, in order to estimate the effect of ground heat pump systems on underground temperature. The simulation was coupled with the ground water-ground heat transfer model and the ground surface heat transfer model. In the result, it was found that the underground change depends on the heat transfer from the ground surface, the heat exchange rate, and the heat conductivity of soil.

LBM을 이용한 Dam Breaking 수치해석 연구 (COMPUTATIONAL STUDY ON TWO DIMENSIONAL DAM BREAKING SIMULATION USING LATTICE BOLTZMANN METHOD)

  • 정노택;하산 엠디.캄롤
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.54-57
    • /
    • 2011
  • In this paper we present an algorithm about how to simulate two dimensional dam breaking with lattice Boltzmann method (LBM). LBM considers a typical volume element of fluid to be composed of a collection of particles that represented by a particle velocity distribution function for each fluid component at each grid point. We use the modified Lattice Boltzmann Method for incompressible fluid. This paper will represent detailed information on single phase flow which considers only the water instead of both air and water. Interface treatment and conservation of mass are the most important things in simulating free surface where the Interface is treated by mass exchange with the water region. We consider the surface tension on the interface and also bounce back boundary condition for the treatment of solid obstacles. We will compare the results of the simulation with some methods and experimental results.

  • PDF

기계학습 기반의 IABP 부이 자료와 AMSR2 위성영상을 이용한 여름철 북극 대기 온도 추정 (The Estimation of Arctic Air Temperature in Summer Based on Machine Learning Approaches Using IABP Buoy and AMSR2 Satellite Data)

  • 한대현;김영준;임정호;이상균;이연수;김현철
    • 대한원격탐사학회지
    • /
    • 제34권6_2호
    • /
    • pp.1261-1272
    • /
    • 2018
  • 북극 지역의 대기 온도는 바다 및 해빙, 대기 사이의 에너지 교환에 큰 역할을 하므로 북극 대기 온도를 정확하게 파악하는 것은 중요하다. 하지만 현장 관측 자료들은 북극 대기 온도의 공간적인 분포를 나타내는 데에 한계가 있다. 따라서 본 연구에서는 부이(buoy) 자료와 Advanced Microwave Scanning Radiometer 2(AMSR2) 위성자료를 이용하여 기계학습 기반 여름철 대기 온도 추정 모델을 구축하였다. 기계학습으로는 random forest(RF) 및 support vector machine(SVM)을 사용하였으며, AMSR2 관측 시간에 따라 하루 두 번의 대기 온도를 추정하였다. 또한 추정된 대기 온도를 유럽 중기예보센터(European Centre for Medium-Range Weather Forecasts, ECMWF)의 ERA-Interim 재분석자료의 대기 온도와 공간 분포를 비교하였다. 교차 검증 결과 두 가지 기계학습 기법 모두 0.84-0.88의 $R^2$$1.31-1.53^{\circ}C$의 RMSE를 보였다. 공간적인 분포에서 IABP 부이 관측 자료가 존재하지 않는 바렌츠해(Barents Sea), 카라해(Kara Sea) 및 배핀만(Baffin bay) 지역에서는 기계학습 모델이 ERA-Interim 대기 온도에 비하여 과소 추정하는 경향을 보였다. 본 연구는 경험적인 북극 대기 온도 추정의 가능성과 한계점을 서술하였다.

소형 냉각식 천정형 제습기의 증발기 전면 풍속에 관한 연구 (A Study on Evaporator Front Air Velocity of Small Refrigeration Ceiling Dehumidifier)

  • 김진철;정경태;금종수;김동규
    • 수산해양교육연구
    • /
    • 제28권4호
    • /
    • pp.1107-1113
    • /
    • 2016
  • In the environment with high humidity causes negative influence on human's body and living condition. As the weather gets more humid, people's interest of dehumidifier for household arising recently. The cooling dehumidifier dehumidify the air by using refrigeration cycle technology which means it removes vapor by let the humid air pass through the cold surface. The amount dehumidified of refrigerating method dehumidifier affected by multiple factors. However, the refrigerating method dehumidifier for household in the market controls pass wind velocity technology to adjust the amount of dehumidification. As the pass wind velocity increases, the amount of wind increases hence the heat exchange amount increases accordingly. However, the amount of dehumidification decreases because the temperature difference between the air and vaporization decreases. Therefore, simply by increasing air velocity does not increase the amount of dehumidification. This research examined the effect of air velocity out of all variety of factors to the amount of dehumidification for refrigerating method dehumidifier.

연료 부족에 의한 고분자전해질형 연료전지의 역전압 성능 (PEMFC performance on reverse voltage by fuel starvation)

  • 이흥주;송현도;김준범
    • 한국수소및신에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.133-140
    • /
    • 2006
  • The performance of proton exchange membrane fuel cell was decreased by reverse voltage using fuel starvation. Performance decrease in local area could be affected by duration and extent of reverse voltage. Hydrogen and air stoichiometic ratio was used to find the experimental condition of abrupt voltage decrease. LabVIEW was used to make control logic of automatic load off system in preset voltage. Reverse voltage experiment was done down to -1.2 V at constant current condition. When fuel cell voltage was reached to preset voltage, electronic load was disconnected to make open circuit voltage for 1 minute. Fuel cell performance was checked every 5 cycle and the degree of performance decrease and/or recovery was estimated. Ohmic resistance and charge transfer resistance were increased and platinum surface area was reduced 41% after reverse voltage experiment.

Surface Ozone Episode Due to Stratosphere-Troposphere Exchange and Free Troposphere-Boundary Layer Exchange in Busan During Asian Dust Events

  • Moon, Y.S.;Kim, Y.K.;K. Strong;Kim, S.H.;Lim, Y.K.;Oh, I.B.;Song, S.K.
    • 한국환경과학회지
    • /
    • 제11권5호
    • /
    • pp.419-436
    • /
    • 2002
  • The current paper reports on the enhancement of O$_3$, CO, NO$_2$, and aerosols during the Asian dust event that occurred over Korea on 1 May 1999. To confirm the origin and net flux of the O$_3$, CO, NO$_2$, and aerosols, the meteorological parameters of the weather conditions were investigated using Mesoscale Meteorological Model 5(MM5) and the TOMS total ozone and aerosol index, the back trajectory was identified using the Hybrid Single-Particle Lagrangian Integrated Trajectory Model(HYSPLIT), and the ozone and ozone precursor concentrations were determined using the Urban Ashed Model(UAM). In the presence of sufficiently large concentrations of NO$\sub$x/, the oxidation of CO led to O$_3$ formation with OH, HO$_2$, NO, and NO$_2$ acting as catalysts. The sudden enhancement of O$_3$, CO, NO$_2$ and aerosols was also found to be associated with a deepening cut-off low connected with a surface cyclone and surface anticyclone located to the south of Korea during the Asian dust event. The wave pattern of the upper trough/cut-off low and total ozone level remained stationary when they came into contact with a surface cyclone during the Asian dust event. A typical example of a stratosphere-troposphere exchange(STE) of ozone was demonstrated by tropopause folding due to the jet stream. As such, the secondary maxima of ozone above 80 ppbv that occurred at night in Busan, Korea on 1 May 2001 were considered to result from vertical mixing and advection from a free troposphere-boundary layer exchange in connection with an STE in the upper troposphere. Whereas the sudden enhancement of ozone above 100 ppbv during the day was explained by the catalytic reaction of ozone precursors and transport of ozone from a slow-moving anticyclone area that included a high level of ozone and its precursors coming from China to the south of Korea. The aerosols identified in the free troposphere over Busan, Korea on 1 May 1999 originated from the Taklamakan and Gobi deserts across the Yellow River. In particular, the 1000m profile indicated that the source of the air parcels was from an anticyclone located to the south of Korea. The net flux due to the first invasion of ozone between 0000 LST and 0600 LST on 1 May 1999 agreed with the observed ground-based background concentration of ozone. From 0600 LST to 1200 LST, the net flux of the second invasion of ozone was twice as much as the day before. In this case, a change in the horizontal wind direction may have been responsible for the ozone increase.

Thermal and Flow Analysis in a Proton Exchange Membrane Fuel Cell

  • Jung, Hye-Mi;Koo, Ja-Ye
    • Journal of Mechanical Science and Technology
    • /
    • 제17권9호
    • /
    • pp.1358-1370
    • /
    • 2003
  • The effects of anode, cathode, and cooling channels for a Proton Exchange Membrane Fuel Cell (PEMFC) on flow fields have been investigated numerically. Continuous open-faced fluid flow channels formed in the surface of the bipolar plates traverse the central area of the plate surface in a plurality of passes such as a serpentine manner. The pressure distributions and velocity profiles of the hydrogen, air and water channels on bipolar plates of the PEMFC are analyzed using a two-dimensional simulation. The conservation equations of mass, momentum, and energy in the three-dimensional flow solver are modified to include electro-chemical characteristics of the fuel cell. In our three-dimensional numerical simulations, the operation of electro-chemical in Membrane Electrolyte Assembly (MEA) is assumed to be steady-state, involving multi-species. Supplied gases are consumed by chemical reaction. The distributions of oxygen and hydrogen concentration with constant humidity are calculated. The concentration of hydrogen is the highest at the center region of the active area, while the concentration of oxygen is the highest at the inlet region. The flow and thermal profiles are evaluated to determine the flow patterns of gas supplied and cooling plates for an optimal fuel cell stack design.

지면경계조건이 UM을 이용한 동아시아 여름철 단기예보에 미치는 영향 (Impacts of Land Surface Boundary Conditions on the Short-range weather Forecast of UM During Summer Season Over East-Asia)

  • 강전호;서명석
    • 대기
    • /
    • 제21권4호
    • /
    • pp.415-427
    • /
    • 2011
  • In this study, the impacts of land surface conditions, land cover (LC) map and leaf area index (LAI), on the short-range weather forecast over the East-Asian region were examined using Unified Model (UM) coupled with the MOSES 2.2 (Met-Office Surface Exchange Scheme). Four types of experiments were performed at 12-km horizontal resolution with 38 vertical layers for two months, July and August 2009 through consecutive reruns of 72-hour every 12 hours, 00 and 12 UTC. The control experiment (CTRL) uses the original IGBP (International Geosphere-Biosphere Programme) LC map and old MODIS (MODerate resolution Imaging Spectroradiometer) LAI, the new LAI experiment (NLAI) uses improved monthly MODIS LAI. The new LC experiment (NLCE) uses KLC_v2 (Kongju National Univ. land cover), and the new land surface experiment (NLSE) uses KLC_v2 and new LAI. The reduced albedo and increased roughness length over southern part of China caused by the increased broadleaf fraction resulted in increase of land surface temperature (LST), air temperature, and sensible heat flux (SHF). Whereas, the LST and SHF over south-eastern part of Russia is decreased by the decreased needleleaf fraction and increased albedo. The changed wind speed induced by the LC and LAI changes also contribute the LST distribution through the change of vertical mixing and advection. The improvement of LC and LAI data clearly reduced the systematic underestimation of air temperature over South Korea. Whereas, the impacts of LC and LAI conditions on the simulation skills of precipitation are not systematic. In general, the impacts of LC changes on the short range forecast are more significant than that of LAI changes.

흰열이 있는 전열면의 R-113에서의 비등열전달에 관한 연구 (A Study on the Boiling Heat Transfer of Heat Surface with Fin Array to R-113)

  • 조시기
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.440-447
    • /
    • 2001
  • This study investigate experimentally the effect of in height, thickness, and clearance on the boiling heat transfer. The heat surfaces having copper fin array is tested for pool boiling. The gas-liquid exchange interference is investigated based on fin array clearance. These test results can be applied to the design of tube bundle system. The fin height of 2 mm is found to be effective. Effects of heat transfer promotion reaches the highest level when the fin clearance is 0.5mm. Also, heat flux is increased when the fin thickness is smaller. But0.2 mm fin thickness is highly recommended.

  • PDF

의성 빙계리 얼음골의 저온 현상에 관한 연구 (Thermal Regime of a Cold Talus Slope in Uiseong Binggye-ri Ice Valley, Korea)

  • 서광수;황수진
    • 한국환경과학회지
    • /
    • 제27권3호
    • /
    • pp.155-165
    • /
    • 2018
  • Observations were conducted in Uiseong Binggye-ri Ice Valley of Korea, where a low temperature talus is located. The talus temperature at Ice Hole near the lower end of the talus remained at $0^{\circ}C$ until summer or autumn and averaged $-0.3^{\circ}C$ over 2 years. The talus temperature at Warm Hole was much higher than the external air temperature during autumn and winter. The outflow of warm air at Warm Hole begins in the late summer of fall. The direction of airflow through the talus surface was determined by the relationship between talus temperature and external air temperature. Annual variations in talus temperature and air exchange between the talus and the external environment can be divided into four periods. It was found that the airflow directions at Warm Hole and Ice Hole were not necessarily opposites. The outflows from the talus at Ice Hole and Warm Hole can occur simultaneously.