• Title/Summary/Keyword: Air tubes

Search Result 495, Processing Time 0.027 seconds

Fouling in Enhanced Tubes-Extension of Kern-Seaton Fouling Model to Repeated Ribbed Tubes (열전달 촉진관내의 화울링 해석-2차원 리브붙이관에 Kern-Seaton 화울링 모델 적용)

  • Kim, N.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.289-298
    • /
    • 1992
  • Fouling is "a major unsolved" area in heat transfer research. Currently, fouling researches are performed in every directions-fundamental aspects, modeling and cumulating experimental data. In this study, an attempt was made to extend the knowledge in enhanced tube fouling. The Kern-Seaton fouling model which was originally proposed for smooth tube fouling was extended to repeated rib tubes. Key parameters-mass transfer coefficient and wall shear stress-were modeled for repeated rib tubes. Some critical points related with the enhanced tube fouling-uncertainties in the mass transfer rate, wall shear stress modeling, deformation of roughness shape during fouling-were discussed, and some quantitative evaluations were made.

  • PDF

Flow Analysis of the Modified Power-Law Non-Newtonian Fluids in the Stenotic Tubes (수정멱법칙 비뉴턴유체의 협착관내 유동장해석)

  • Sub, S.H.;Yoo, S.S.;Chang, N.I.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.227-236
    • /
    • 1994
  • Steady flows of Newtonian and non-Newtonian fluids in the stenotic tubes with various stenotic shapes are numerically simulated. Validity of the modified power-law model as a constitutive equation for the purely viscous non-Newtonian fluid is discussed and the results of the power-law model are compared with those of the Carreau model, the Powell-Eyring model and experimental data for blood. Flow characteristics and reattachment lengths for non-Newtonian fluids in the stenotic tubes are presented extensively. Also, the analysis is extended to predict the influences of diameter ratio, stenosis spacing, number of stenosis and Reynolds number on the flow characteristics in the multiple stenotic tubes.

  • PDF

Characteristic Analysis of Electromagnetic-ultrasonic Guided Waves for Defect Signals in Condenser Tubes (전자기유도초음파를 이용한 복수기 전열관 결함신호 특성분석)

  • Choi, Sang-Hoon;Wang, Gi-Nam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.174-178
    • /
    • 2015
  • This paper describes a signal processing technique for identifying signals from defects by using an electromagnetic-ultrasonic guided waves method based on a magnetostrictive sensor that generates a torsional mode (T(0, 1)). Because this technique is based on the digital filtering, the filtered signals provide information on the relationship between the cutoff frequency of band-pass filter and the characteristic of defect signals in heat exchange tubes. To verify the performance of the technique, artificial defects with various thickness reduction ration and shape were machined in titanium tubes, and digital filtering results are reported. The results show that digital filtering provides information to the identify shape of defects and the contact condition between the tube and support ring. Therefore, the proposed technique has good potential as a tool for evaluating the integrity of heat exchange tubes.

Effects of the Corrugated Tubes on Pressure Drop in Concentric Annuli (환형관에서 파형튜브가 압력강하에 미치는 효과)

  • 안수환;손강필
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.803-809
    • /
    • 2001
  • The present paper presents the experimental results of pressure drip of water flow in annuli with spirally corrugated inner tubes in the turbulent flow regime. To understand the underlying physical phenomena responsible for heat transfer enhancement, pressure drop data documented elsewhere are combined to compare with those obtained from the present experiment for the Reynolds numbers of 1,000 to 8,000. Friction factors were found to be functions of trough depth, pitch and angle, and the annulus radius ratio. Friction factor increases in the spirally fluted tubes were larger than those in the corrugated tubes.

  • PDF

An Experimental Study of Flow Boiling Heat Transfer inside Small-Diameter Round Tubes (원형 세관내 대류비등열전달에 관한 실험적 연구)

  • 추원호;방광현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.748-755
    • /
    • 2004
  • Flow boiling heat transfer in small-diameter round tubes has been experimentally studied. The experimental apparatus consisted mainly of refrigerant pump, condenser, receiver, test section of a 1.67 mm inner-diameter round tube and pre-heater for control of refrigerant quality at the inlet of test section. To investigate the effect of bubble nucleation site characteristics of different tube materials, three different tubes of copper, aluminum and brass were used. The ranges of the major experimental parameters were 5∼30 ㎾/$m^2$ of the wall heat flux, 0.0∼0.9 of the inlet vapor quality and the refrigerant mass flux was fixed at 600 kg/$m^2$s. The experimental results showed that the flow boiling heat transfer coefficients in small tubes were affected only by heat flux, but independent of mass flux and vapor quality. The effect of tube material on flow boiling heat transfer was observed small.

Experimental Studies on Heat Transfer in the Annuli with Corrugated Tubes (파형관을 가진 이중 환형관의 열전달에 관한 실험적 연구)

  • 안수환;손강필
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.8
    • /
    • pp.683-689
    • /
    • 2002
  • This paper is to present the results of a comprehensive study on heat transfer in annuli with spirally corrugated inner tubes in the turbulent regime. Tube surface-temperature measurements were used to explain the enhancement phenomena in the annuli with several different corrugated tubes. Nusselt numbers were between 1.1 and 2 times the smooth annulus values. These enhancement values can be used to determine the appropriate range of applicability for spirally corrugated annuli.

A Generalized Empirical Correlation on the Mass Flow Rate through Adiabatic Capillary Tubes with Alternative Refrigerants (대체냉매를 적용한 일반화된 모세관의 유량예측 상관식)

  • 최종민;장용희;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.744-750
    • /
    • 2003
  • The performance of adiabatic capillary tubes are measured to provide the database for a generalized correlation. Test conditions and capillary tube geometries are selected to cover a wide range typically observed in air-conditioning and heat pump applications. Based on extensive experimental data for R22, R290, and R407C measured in this study, a generalized correlation for refrigerant flow rate in adiabatic capillary tubes is developed by implementing dimensionless parameters for tube inlet conditions, capillary tube geometry, and refrigerant properties. The correlation yields good agreement with the present data for R22, R290, and R407C with average and standard deviations of 0.9% and 5.0%, respectively. In addition, approximately 97% of the data for Rl2, R134a, R152a, R410A, and R600a obtained in the open literature are correlated within a relative deviation of $\pm$ 15%.

The Effect of the Thermal Conductivity of a Tube and the Convective Heat Transfer on the Outer Surface of a Tube on the Energy Separation in Vortex Tubes (튜브의 열전도도와 튜브 외면에서의 대류열전달이 보텍스튜브의 에너지 분리에 미치는 영향)

  • 유갑중;이병화;최병철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.845-852
    • /
    • 2001
  • The phenomena of energy separation in vortex tubes was investigated experimentally to see the effects of the conductivity of a tube and convective heat transfer on the outer surface of a tube. The experiment was carried out with different conductivity (pyrex, stainless steel and copper) of a tube and three kinds of convective heat transfer modes (adiabatic condition, natural convection (air) and forced convection (water) on the outer surface of a tube. the results were obtained that hot exit fluid temperature was highly affected by a change of conductivity of a tube when the outer surface was cooled by the forced convection of water. However, the cold exit temperature was little affected by heat transfer modes on the outer surface in vortex tubes.

  • PDF

Numerical investigation of plate fin performance for a compact heat exchanger (밀집형 열교환기에 사용하는 평판핀 성능에 관한 수치적 연구)

  • 유재욱;송태호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.292-300
    • /
    • 1999
  • Fin conduction not only enhances heat transfer to the ambient air but also increases tube-to-tube conduction. The latter is known to deteriorate the heat exchanger performance. Heat conduction between neighboring tubes thorough the fin is numerically investigated for accurate performance analysis of plate finned-tube heat exchangers. Governing equations for arbitrary plate fin are solved and the temperature distribution is obtained using the principle of superposition. Analysis is made using finite element method by changing the shapes of fin, the arrangements of tubes and the fin parameter mD. It is found that tube-to-tube conduction is significant when mD is small or the distance between neighboring tubes is small.

  • PDF

A Study on the Noise Reduction of a Portable Fuel Cell System (휴대용 연료전지 시스템의 소음 저감에 대한 연구)

  • Jeon, In-Youl;Bae, Joon-Soo;Oh, Min-Jung;Choi, Sang-Hyeon;Lee, Choong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.858-861
    • /
    • 2006
  • In this paper, a study on the noise reduction in a mobile fuel cell system is presented. Among various fuel cell systems around 20W capacities designed for mobile electronic devices, the active direct methanol fuel cell (DMFC) systems have been recently developed. In such systems, the primary noise source is the air pump which provides sufficient air flow ($5{\sim}6$ liter/min) for electrochemical reaction with methanol fuel while the noise contributions from other auxiliary parts are relatively small. Especially, the discrete noise tones generated by the air pump are dominant and those frequency peaks related to the rotor harmonics are needed to be suppressed by a silencer. Therefore. the Herschel/Quinke (HQ) tubes, which use the out-of-phase cancellation of acoustic waves propagating through direct and indirect pathways, are applied to the inlet of the air pump. Performance of noise reduction with HQ silencer is analytically estimated by calculating the transmission. The length and number of thin HQ tubes are optimized to decrease the radiated noise. As a result, the sound pressure level could be successfully reduced by about 10 dB after applying three serially connected HQ tubes.

  • PDF