• 제목/요약/키워드: Air to water

검색결과 6,142건 처리시간 0.03초

국내 하천수 미활용에너지 부존량에 관한 조사연구 (A Study on the Potential Energy Reserve Amount of Domestic River Water as Unutilized Energy Resource)

  • 박일환;윤형기;박준택;장기창;이영수
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.521-528
    • /
    • 2005
  • This study has been conducted to investigate the potential energy reserve amount of river water as energy resource with useful temperature difference. Since the river water temperature is one of the primary parameters deciding the potential amount of river water energy reserve amount, the climate change effects on it are critically important. In this study, the heat exchange processes and the inter-relationship between the air temperature and river water temperature have been theoretically analyzed. Based on the present study, the potential energy reserve of river water is calculated to amount to 192,000 Tcal/year. Among this, it is estimated that approximately 2,000 Tcal/year can be directly utilized for heat pump energy sources.

Exponential Nozzle을 사용한 Water Jet 발생에 관한 연구 (A study on the Formation of Water Jet From an Exponential Nozzle)

  • 김상진;윤의수;최태민
    • 한국기계연구소 소보
    • /
    • 통권20호
    • /
    • pp.5-11
    • /
    • 1990
  • Most water cannon machines use compressed gas to accelerate a piston which extrudes water through a cumulation nozzle. Very high jet stagnation-pressures can be achieved by using a specially-shaped nozzle which is initially filled with air or vacuum. The objective of this study was to establish the basic technology of water cannon using exponential type nozzle. An experimental water cannon including high pressure components such as exponential nozzle and 300atm air resrvior were designed and tested. Parameters that influence the performance of the system and jet characteristics were examined.

  • PDF

미세기포 발생펌프 내 체류시간에 따른 미세기포의 발생 농도 예측 (Prediction of Micro-Bubble Releasing Concentration with the Retention Time of a Micro-Bubble Generating Pump)

  • 매튜스탠리암브로샤;이창한
    • 한국환경과학회지
    • /
    • 제25권6호
    • /
    • pp.829-837
    • /
    • 2016
  • The mechanism of micro-bubble generation with a pump is not clarified yet, so the design of water treatment systems with a micro-bubble generating pump is based on trial and error methods. This study tried to explain clearly quantitative relationships of experimental micro-bubble concentration ($C_{air}$) of continuous operation tests with a micro-bubble generating pump and theoretical air solubility. Operation parameters for the tests were discharge pressure ($P_g$), water ($Q_{w0}$) and air ($q_0$) flow rates, orifice diameter ($D_o$), and retention time (t). The experimental micro-bubble concentrations ($C_{air}$) at 4.8 atm of discharge pressure ($P_g$) were in the range of 21.04 to 25.29 mL/L. When the retention time (t) by changing the pipe line length ($L_p$) increased from 1.22 to 6.77s, the experimental micro-bubble concentrations ($C_{air}$) increased from 25.86 to 30.78 mL air/L water linearly. The dissolved and dispersed micro-bubble concentrations ($C_{air}$) are approximately 4 times more than the theoretical air solubility.

평판관-루버핀 열교환기의 공기측 열전달 및 압력강하 특성에 관한 실험적 연구 (An Experimental Study on Heat Transfer and Pressure Drop of Air Side in a Plate-Louvered Fin Heat Exchanger)

  • 강병하;김석현;장혁재;박병규
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.485-492
    • /
    • 2002
  • Heat transfer and pressure drop on the air side of a plate-louvered fin heat exchanger with new shape of louver fin have been investigated experimentally. Water is employed inside the flat tube to transfer heat with air for convenience. This problem is of particular interest in the design of a plate-louvered heat exchanger. The effect of air flow rate, water flow rate and water temperature on pressure drop as well as heat transfer in air side are studied in detail. The present results showed a good agreement qualitatively with the previous results in general. Based on the experimental data, f-factor and j -factor correlations of the present louvered-fin are suggested. It is also found that heat transfer could be enhanced with new shape of louver fin, compared with the conventional louvered-fin, while the f-factor remains unchanged.

부레옥잠 바이오매스의 특성분석과 제지적용성 평가 (Characterization of Water Hyacinth (Eichhornia crassipes) Biomass and Evaluation of Applicability as an Organic Filler to Papermaking)

  • 김동성;허윤성;성용주;한승원;서철모
    • 펄프종이기술
    • /
    • 제46권5호
    • /
    • pp.79-87
    • /
    • 2014
  • The enrichment with nutrients in rivers and lakes becomes serious problems in Korea. As the environmental friendly solution, the phytoremediation are getting more attention and the water hyacinth could be a strong candidate plant for this. Water hyacinth is a free floating freshwater plant proven to be a effective plant used for a purification of a polluted lakes, sewage wastewater, and livestock wastewater. The biggest obstacles for application of water hyacinth in Korea could be the disposal of the water hyacinth before winter, because there is no feasible use for the water hyacinth until now. In this study, the characteristics of water hyacinth were deeply investigated for providing background data to develop appropriate application of the water hyacinth. The water hyacinth was fractioned three parts, leaf, air blader, root of which morphological properties were evaluated with microscope and field emission scanning electron microscope (FE-SEM). The water contents of each parts of the water hyacinth were 87% for leaf, 96.5% for air bladder, 94.6% for root. The chemical compositions of each parts were also measured and showed around 29% of hot water extract in leaf and air bladder, 42% holocellulose for leaf, 47% holocellulose for air bladder. The application of water hyacinth biomass without root parts to papermaking provided bulkier structure, but the tensile strength was decreased.

미세버블을 이용한 바이오가스 탈황정제 연구 (Desulfurization of Biogas Using Micro Bubble in a Biogas Plant)

  • 탁봉열;탁봉식;김찬규;민길호;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.518-523
    • /
    • 2013
  • This paper describes the reduction of a hydrogen sulfide ($H_2S$) generated from a biogas plant. Micro bubble system is adopted to supply air into the water in the reaction chamber, which can increase the contact area of the supplied air to the reserving water. Two stage reaction chambers having two reaction rooms are designed and manufactured to enhance the reduction rate of a hydrogen sulfide. Sodium hydroxide (NaOH) is also considered to get rid of a hydrogen sulfide. Air volume rate to the water in a reaction chamber is maintained between 0.5 and $1.0m^3/min$. Throughout experimental measurement of the concentration of a hydrogen sulfide by changing the volume of supplied air into the water, reduction rate of a hydrogen sulfide increases as air volume increases. Adding sodium hydroxide to the water with the air supply can reduce effectively a hydrogen sulfide up to 99.5% from biogas. It is noted that a hydrogen sulfide generated by a biogas plant can reduce by supplying micro bubble air and sodium hydroxide effectively.

기액 이상류시의 원심펌프특성에 관한 실험적 연구 (An Experimental Study on the Centrifugal Pump Characteristics in Air-Water Two-Phase Flow)

  • 김성윤;이상일;김유택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권6호
    • /
    • pp.685-692
    • /
    • 2006
  • In a general centrifugal pump, if it is operated in a two-phase flow the activity of the impeller usually degrades and occasionally losses its function. However, the effect of break down of centrifugal pump due to entrained air has not been clarified yet. This paper shows the air-water two-phase flow characteristics of closed type and semi-open type impellers. In a sing1e-phase flow, closed-type impeller has higher efficiency and head. But in air-water two-phase flow semi-open type impeller's rates of decreases of efficiency and head are decreased.

콘덴싱가스보일러 제어를 위한 공급수알고리즘 (The Supply Water Algorithm for a Condensing Gas Boiler Control)

  • 한도영;유병강
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.441-448
    • /
    • 2011
  • The energy consumption of a condensing gas boiler may be greatly reduced by the effective operation of the unit. In this study, the supply water algorithm for a condensing gas boiler control was developed by using the fuzzy logic. This includes the supply water set temperature algorithm, and the control algorithms of a gas valve, a blower and a pump. For the set temperature algorithm, the outside air temperature and the return water temperature were used as input variables. The supply water temperature difference and its slope were used as input variables of the gas valve and blower control algorithm. And the supply water temperature and the return water temperature were used as input variables of the pump control algorithm. In order to analyse performances of these algorithms, the dynamic model of a condensing gas boiler was used. The initial start-up test, the supply water set temperature change test, the outside air temperature change test, and the return water temperature change test were performed. Simulation results showed that algorithms developed in this study may be practically applied for the effective control of a condensing gas boiler.

Effect of Flow Inlet or Outlet Direction on Air-Water Two-Phase Distribution in a Parallel Flow Heat Exchanger Header

  • Kim, Nae-Hyun;Kim, Do-Young;Cho, Jin-Pyo;Kim, Jung-Oh;Park, Tae-Kyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권2호
    • /
    • pp.37-43
    • /
    • 2008
  • The air and water flow distributions are experimentally studied for a round header - ten flat tube configuration. Three different inlet orientation modes (parallel, normal, vertical) were investigated. Tests were conducted with downward flow configuration for the mass flux from 70 to $130kg/m^2s$, quality from 0.2 to 0.6, non-dimensional protrusion depth (h/D) from 0,0 to 0.5. It is shown that, for almost all the test conditions, vertical inlet yielded the best flow distribution, followed by normal and parallel inlet. Possible explanation is provided using flow visualization results.

기체연료 엔진에서 공연비제어를 위한 흡입공기량 추정 (Estimation of Inlet Air Mass Flow for Air-Fuel Raito Control of Gaseous-Fuel Engines)

  • 심한섭;이강윤;선우명호;송창섭
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.131-139
    • /
    • 2001
  • Highly accurate control of the air-fuel ratio is important to reduce exhaust gas emissions of the gaseous-fuel engines. In order to achieve this purpose, inlet air mass flow must be measured exactly, and precise engine models are necessary to design engine control systems. In this paper, the effects of water vapor and gaseous fuel that change the air mass flow are studied. The effective air mass ratio is defined as the air mass flow divided by the mixture mass flow, and also it is applied to the estimation of the inlet air mass flow. The presence of the gaseous fuel and the water vapor in the mixture reduces the air partial pressure and the effective air mass ratio of the gaseous-fuel engines. The Experimental results for an LPG engine show that the estimation of the inlet ai mass flow based upon the effective air mass ratio is more accurate than that of the normal air mass flow.

  • PDF