• 제목/요약/키워드: Air to water

검색결과 6,142건 처리시간 0.036초

마이크로 관류수차의 상수도 관로시스템 적용에 관한 연구 (Application of Micro Cross-Flow Turbine to Water Supply System)

  • 최영도;쿠로카와준이치
    • 한국유체기계학회 논문집
    • /
    • 제9권3호
    • /
    • pp.36-43
    • /
    • 2006
  • Recently, micro hydropower and it's useful utilization are taking a growing interest as a countermeasure of global worming by carbon dioxide and exhaustion of fossil fuel. The purpose of this study is to investigate the possibility of extracting micro hydropower wasted by a valve in water supply system using micro cross-flow hydraulic turbine. In order to fulfill the functions of controlling flow rate and pressure in substitute for the valve, air and water are supplied into an air suction hole which is installed on the side wall of micro cross-flow hydraulic turbine. The results show that in case of supplying a lot of air into the air suction hole, about 50% of flow rate and relatively high value of loss coefficient are controlled by the turbine. Moreover, including high possibility of applying the micro cross-flow turbine to water supply system, extended application of the turbine to the water discharge system of drainage and irrigation canal.

불포화 토양내 유류성분의 포화도 평가를 위한 분배추적자의 활용 방안

  • 박기호;박민호;신항식;고석오
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2006년도 총회 및 춘계학술발표회
    • /
    • pp.20-28
    • /
    • 2006
  • Partitioning tracer tests were conducted to quantify the saturation degree of diesel and water in unsaturated soil, respectively. The use of partitioning tracers that partition into diesel, water, and air (i.e., three-phase partitioning), is in attractive alternative to traditional coring and analysis method. These gaseous partition tracers not global warming gas like CFC's are Butane, Acetylene, Ethylene, Methylene chloride, and Methane. The glass column packed with sandy soil was prepared, in which a three-phase system of air, water, and diesel was maintained. Conservative and partition gas tracers were injected into the columns and detected easily using a single GC detector(FID). For each tracer, a method of moments was used to estimate partition coefficient between water, diesel. and the air, respectively. The results from the column studies showed that the diesel/air tracer partition coefficient ranged from 8.2 to 868 and 9.2 for water/air. Saturation degree of diesel and water in the column, predicted by the partition coefficients obtained from tests, was underestimated up to 66% and 23% respectively.

  • PDF

부영양호 원수의 냄새유발 물질 탈기 특성 (Air stripping of odor causing materials from eutrophic lake water)

  • 박노백;송용효;나광주;박상민;전항배
    • 상하수도학회지
    • /
    • 제22권5호
    • /
    • pp.523-529
    • /
    • 2008
  • Algal blooms in a local eutrophic lake often produces the musty and earthy taste & odor problems. Since the odor causing compounds(OCCs) including geosmin and 2-MIB have their own volatility, the OCCs can be removed from water by air stripping methods. Removal of TON(threshold odor number) as an index for OCCs could be fitted well with the first order equations($R^2=0.9$ above), where the air stripping coefficient of TON, k was in the range between 0.0055 and 0.0097 according to the aeration time. k within 30min aeration tests was 0.0097, while it was 0.0055 where the aeration time extended to 150min. With 15 mg/L of PAC, removal of TON was not simulated with 1st order equation within 30min aeration. Within 30min aeration, OCCs rather than geosmin and/or 2-MIB could be removed easily by air stripping or PAC adsorption, while OCCs such as geosmin and/or 2-MIB could be removed slowly by air stripping after 30min aeration. Geosmin and 2-MIB were not readily removed by air stripping(k of them were 0.0018~0.0047 and 0.0018~0.0034, respectively at different air flow rates). Geosmin could be removed by air stripping a little better than 2-MIB.

Al-Alloy 7075-T651의 부식피로균열 성장거동에 관한 연구(I) (A Study on Corrosion Fatigue Crack Growth Behavior in Al-Alloy 7075-T651 (I))

  • 김봉철;한지원;우흥식
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.113-120
    • /
    • 1998
  • Fatigue crack growth rates(i.e. crack initiation and crack growth of short and long crack) are investigated using commercial plates of high strength Al alloy 7075-T651 for the transverse-longitudinal(T-L) direction in air, water and sea water. Also, the evaluation direct current potential drop(D.C.P.D) method and the fractographical analysis by SEM are carried out. Near threshold region, short crack growth rates were much faster than those of comparable long cracks, and these short crack growth rates actually decrease with increasing crack growth and eventually merge with long crack data. Fatigue crack propagation rates in aggressive media(i.e. sea water) increase noticeably over three times those in air. One of the most significant characters in this phenomenon as a corrosion-fatigue causes an acceleration in crack growth rates. Sea water environment, particularly Cl$^{[-10]}$ solution brings the most detrimental effects to aluminum alloy. The result of fractographical morphology in air, water and sea water by SEM shows obvious dimpled rupture and typical striation in air, but transgranular fracture surface in water and sea water.

  • PDF

발수 처리한 ALC 분말이 유화처리 정제유지류(ERCO) 혼입 모르타르의 품질특성에 미치는 영향 (Effects of Water Repellency Treated ALC Powder on the Properties of Mortar Mixed with ERCO)

  • 이명호;박준희;김상섭;박재용;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.112-113
    • /
    • 2014
  • This study was done to resolve the air reduction in mortar when mixed with ERCO. Effects of the water repellent ALC powder due to its particle size and substitution ratio on the cement mortar with ERCO was analyzed. Results showed more water repellent ALC powder ensured more air but did not affect the size of particles. It was determined the compression was caused by more air and water added to achieve the flow. Therefore, substituting with water repellent ALC powder may compensate for the air reduction in mortar with ERCO. Other measures and approaches are needed in order to resolve the reduced strength.

  • PDF

Numerical Simulation and Laboratory Test Analysis of Air Sparging for TCE Remediation

  • 김훈미;이강근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.348-351
    • /
    • 2003
  • Trichloroethylene, which is one of the representative DNAPL, has been found in underground water sources as a result of the manufactural use, and disposal of the chemical. In this research, in situ air sparging method was chosen to reduce the TCE concentration from the source zone. The concentration reduction in the source zone resulting from air sparging is simulated using the modified STOMP Water-Air operational mode in a two dimensional axisymmetric domain and bench scale test is conducted to analyze the performance of air sparging. The results of laboratory tests are compared with numerical simulations.

  • PDF

미세기포 발생 펌프에서 생성되는 기포농도와 용존공기농도의 비교 (Comparison of Dissolved Air and Micro-Bubble Concentration by a Micro-Bubble Generating Pump)

  • 이창한;안갑환
    • 한국환경과학회지
    • /
    • 제23권11호
    • /
    • pp.1835-1842
    • /
    • 2014
  • The goal of this study was to evaluate micro-bubble concentration ($C_{air}$) in water by air/water ratio (A/W ratio) with a micro-bubble generating pump. The estimation of micro-bubble concentration is based on the balance of inlet/outlet air and water flow rate. On net A/W ratio to be generated micro-bubble, we found that the obtained the $C_{air}$ are shown as a function of discharge pressure ($P_g$) of the micro-bubble generating pump. The correlation of the $C_{air}$ and the $P_g$ ($C_{air}=3.261P_g-1.754$) was adequately described by the least square methods with a high correlation coefficient (r = 0.9459) and calculated values fit the experimental data quite well. The $C_{air}$ was lower than theoretical dissolved air concentration ($C_{aq}$) calculated by Henry's law. The $C_{air}$ for being operated the micro-bubble generating pump was 6.75 - 39.53 mL/L, however, we found that the optimum of the $C_{air}$ to generate micro-bubble was the range from 10 to 12 mL/L.

열전모듈을 이용한 에어컨의 방열부 냉각특성에 대한 연구 (Cooling Characteristics at Hot Side of the Thermoelectric Module for an Air Conditioner)

  • 김서영;강병하;장혁재;김석현
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.214-220
    • /
    • 2002
  • A small air conditioner using thermoelectric module has been designed and built. Three types of cooling methods, such as air cooling, closed-loop water cooling, and evaporative cooling, for hot side of thermoelectric module have been investigated. Among three types of cooling method, the evaporative cooling method is seen to be the most effective to achieve the steady state operation of a thermoelectric air conditioner The system performance with evaporative cooling method are also studied in detail for several oprating parameters, such as input power to the thermoelectric module, water or air flow rate at the hot side, and air flow rate at the cold side. The results obtained indicate that the cooling capacity of a system is increased with an increase in the input power to the thermoelectric module while the system COP is decreased. It is also found that the optimal air flow rate as well as water flow rate at the hot side is needed for the best system performance at a liven operating condition. Both the system COP and cooling capacity are increased as the air flow rate at cold side is increased.

촛불 실험과 관련된 오개념 교정을 위한 지도방안 탐색 (Exploration of the teaching method for the prescription of the misconceptions on the Candle Experiment)

  • 전우수
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제18권2호
    • /
    • pp.145-151
    • /
    • 1999
  • There is an experiment in the elementary science textbook which a burning candle hold upright in a water tank and a beaker is converted over the burning candle, the candle flame goes out and the water rises into the beaker. Some reference books including teachers' guide for the elementary school teachers explain the reason why water rises that oxygen is "used up", so water rises the same volume of consumed oxygen into the beaker. But this explanation is only partially correct. In this study, discrepancies of the explanation that oxygen is "used up" are analyzed. Water rises by two major reasons. One is that water can rise to the level about l/3 of the volume of consumed oxygen. The other is that the beaker is converted over the burning candle which produces hot CO2 and water vapor, and the candle's flame heats the air around it to expand, after the candle flame goes out, the air in the beaker cools and water vapor changes to liquid water, so, air pressure in the beaker is reduced, and the water is pushed into the beaker by great air pressure outside. 1 demonstrate a inquiry teaching method of the candle experiment.

  • PDF

대전력 반도체 정류기 수냉식 냉각 설비 냉매 온도 제어시스템에 관한 연구 (The Study of Thyristor Valve Water Cooling Control Systems)

  • 임익헌;류호선
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.230-233
    • /
    • 1999
  • The design and implementation of thyristor water cooling control systems in considered in this pape Coolant water is pumped through the thyristor heat sinks where heat is transferred from the thyristo to the water. This water is then pumped through outdoor air-to-water heat exchangers where heat I transferred to the outside air. Since the water must be pure, it is filtered and de-ionized. Also the water temperature must be below dew-point temperature. Redundant pumps, outdoor heat exchangers, power supply system, controller monitoring system are provided for system reliability and availability.

  • PDF