• 제목/요약/키워드: Air table

검색결과 240건 처리시간 0.027초

다공성 패드를 갖는 챔버의 배열에 따른 공기 부상 테이블의 비접촉 부상 수준에 대한 연구 (Non-Contact Level on Air Levitation Table with Porous Chamber Array)

  • 김준현;정영석;이태걸;김태훈;정효재
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.913-920
    • /
    • 2013
  • This paper presents an applicable basic design that can configure non-contact levitation table for conveying a large sheet of glass. The suggested air levitation table consists of a series of air chambers with porous pads and fans as the conveyor system. The air supply chambers are arrayed to supply an adequately strong upward airflow for supporting the glass. Levitation is controlled by the size and discharge velocity, of the chamber arrays, as well as the glass supporting height. After pre-evaluation of the glass rigidity and the filer functional performance, a one-way fluid structure interface (FSI) analysis is performed for predicting pressure and deflection working of the 8G glass in the transverse and longitudinal directions, respectively. After comparing calculated levels of flatness of the glass, it determines the chamber array for the linear non-contact conveying motion.

뇌병변 소아환자의 기립보조기 사용 시 접촉 패드 유형에 따른 근활성도 비교 (Comparison of Electromyography Activity in Accordance with Contact Pad Type during the Use of a Standing Table for Pediatric Patients with Brain Lesions)

  • 이종훈;오민우;하종규;서재용;황화식
    • 재활복지공학회논문지
    • /
    • 제8권3호
    • /
    • pp.161-168
    • /
    • 2014
  • 본 연구에서는 Pneumatic air fitting system을 적용한 기립보조기 제품을 뇌병변 소아환자를 대상으로 기립보조기의 신체 고정용 폼패드(foam pad)와 에어패드(air pad) 사용 시, 뇌병변 장애아동들의 체간 및 하지근육의 수축 양상을 비교 분석하였다. 연구결과, 패드(foam pad vs. air pad) 유형에 따른 근육별 근력 활성도는 차이가 있었다. 이러한 차이는 큰 동작(식사동작)에서 크게 나타나고, 작은 동작(쓰기동작, 읽기동작)이 작게 나타났다. 이는 Pneumatic air fitting system을 적용한 기립보조기 제품 사용 시, 기존 폼패드에 비해 사용자에게 좀 더 편안함을 제공하는 것으로 나타났다.

  • PDF

대형 트럭 반능동형 캐빈 공기 현가시스템의 승차감 성능 평가 연구 (Ride Performance Evaluation of a Heavy Truck Semi-active Cabin Air Suspension System)

  • 이지선;최규재;이광헌
    • 한국자동차공학회논문집
    • /
    • 제16권5호
    • /
    • pp.77-83
    • /
    • 2008
  • Semi-active cabin air suspension system improves driver's comfort by controlling the damping characteristics in accordance with driving situation. For the driver's comfort evaluation, test procedure has the two methodologies which are filed test and lab test. A field test method has a drawback. It requires a lot of time and money on repetitive test, due to the sensitivity of field test. On the other hand, the test with six axes simulation table at laboratory can obtain the repeatability of test, better than the field test method. In this paper, the procedures of ride performance test and control logic tuning with the table are presented. Drive files of the table can be represented with the almost same input condition as field test data. According to the result from the comparative test using six axes simulation table between passive and semi-active system by making ECU logic tuning, the RMS acceleration of semi-active cabin air suspension system was reduced by 29.6% compared with passive system.

공동주택 주방의 급ㆍ배기효율을 고려한 기계환기 설계에 관한 연구 (A Study on the Mechanical Ventilation Design that Consider Supply and Exhaust Efficiency of the Apartment House Kitchen)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제15권3호
    • /
    • pp.101-108
    • /
    • 2004
  • To find more efficient exhaust effect, air curtain of upward or downward trend in gas table and left or right side of range hood were made. As result that film vapor from range hood lower part by digital camera, the air current change by moving existence and nonexistence of exhaust fan and direction of air curtain were known. Under all experiment condition, upward air curtain superior exhaust performance.

Air-Bag Head 가압식 300mm 웨이퍼 폴리싱 테이블의 가압 분포 해석 (Analysis of Contact Pressure for a 300mm Wafer Polishing Table with Air-Bag Head)

  • 노승국
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.310-317
    • /
    • 2013
  • In this paper, the contact pressure of the wafer and polishing pad for final polishing process for 300 mm-wafer were investigated through numerical analysis using FEM tool, ANSYS. The distribution of the contact pressure is one of main parameters which affects on the flatness and surface roughness of polished wafers. Two types of polishing head, a hard type head with ceramic disk and a soft type head with air bag were considered. The effects of the deformation and initial shape of table on the contact pressure were also examined. Both heads and tables were modeled as 3D finite element model from solid model, and the material properties of polishing pads and rubber plate for the air-bag head were obtained from tensile tests. The contact pressure deviation on wafer surface was smaller with air bag head than hard type head even when the table had form errors such as convex or concave. From this 3D analysis, it could be concluded that the air-bag head has better uniformity of the contact pressure on wafer. Also, the effects of inner diameter of air bag and radial clearance between wafer and retainer were investigated as view point of contact pressure concentration on the edge of wafer.

공기압 구동 원주 할출 기구의 개발에 관한 연구 (A Study on the Indexing Table by the Penumatic Poeration)

  • 오진안;강인각;한창수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.734-738
    • /
    • 1997
  • In this study, we developed the indexing table opering by pneumatic actuation. We doubled the torque of index table by using specialy desingned air pipe and two pistons. And by locating two pistons We perform several tests and this results is written below.

  • PDF

정밀가공장비용 면진시스템의 동특성 (Dynamic Characteristics of the Vibration Isolation System for High Precision Processing Machinery)

  • 김영중;김병현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1115-1121
    • /
    • 2003
  • The vibration isolation table system for the high precision Processing machinery has been developed. The system uses air spring as its isolation elements. An investigation of the model and the test results showed that the diaphragm has a role in the mathematical model. The vibration levels at various floors in the laboratory were investigated during operating the large shaking table for the selection of optimum installation location. The vibration test on the designed system showed good isolation performances.

  • PDF

남향경사면의 월평균 전일사량 (Monthly Average Insolation Data on South-Facing Inclined Surfaces)

  • 김두천
    • 대한설비공학회지:설비저널
    • /
    • 제8권4호
    • /
    • pp.254-259
    • /
    • 1979
  • Radiation data on south-facing surfaces required for the simplified design pro cedures for solar energy systems, have been computed using the method by Liu and Jordan. For the five localities of South Korea selected from reference 6, the factor R for the conversion of the monthly average daily total radiation on a horizontal surface to that on an inclined surface is presented in Table 5. For the other localities, the convession factor R can by computed using Table 2 through Table 4.

  • PDF

조리대에 급기구를 가진 주방 레인지후드의 배기 성능 (Exhaust Performance of a Kitchen Hood System with a Supply Air Slot on a Kitchen Table)

  • 성순경
    • 설비공학논문집
    • /
    • 제28권12호
    • /
    • pp.489-494
    • /
    • 2016
  • There have been many cases when an air curtain installed in the apartment could not remove the gases well, such as carbon dioxide and particles like as smoke, oils, and vapors generated during cooking to disperse pollutants into the room. This study used a numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed front of the kitchen table. The result of this study was that when the air amount supplied by an air curtain through the slot was about 50% of the exhaust amount, the capturing efficiency of the range hood for pollutants increased 90% more than without an air curtain. Even when the amount of supplied air was small, the capturing efficiency improved markedly with the use of an upward air curtain. In case that the air flow rate of the slot was greater than 60%, the capturing efficiency decreased.