• Title/Summary/Keyword: Air supply height

검색결과 31건 처리시간 0.026초

다공성 패드를 갖는 챔버의 배열에 따른 공기 부상 테이블의 비접촉 부상 수준에 대한 연구 (Non-Contact Level on Air Levitation Table with Porous Chamber Array)

  • 김준현;정영석;이태걸;김태훈;정효재
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.913-920
    • /
    • 2013
  • This paper presents an applicable basic design that can configure non-contact levitation table for conveying a large sheet of glass. The suggested air levitation table consists of a series of air chambers with porous pads and fans as the conveyor system. The air supply chambers are arrayed to supply an adequately strong upward airflow for supporting the glass. Levitation is controlled by the size and discharge velocity, of the chamber arrays, as well as the glass supporting height. After pre-evaluation of the glass rigidity and the filer functional performance, a one-way fluid structure interface (FSI) analysis is performed for predicting pressure and deflection working of the 8G glass in the transverse and longitudinal directions, respectively. After comparing calculated levels of flatness of the glass, it determines the chamber array for the linear non-contact conveying motion.

Atomize 법에 의한 용융소재의 고효율 미세화에 관한 연구 (제1보:공기제트에 의한 액체의 공급기구) (A STUDY ON HIGH-EFFICIENCY ATOMIZATION OF MOLTEN MATERIALS (PART 1: AN EXPERIMENTAL STUDY ON SUPPLYING MECHANISM BY AIR JETS))

  • 오재건;이충원;석지권
    • 한국분무공학회지
    • /
    • 제2권2호
    • /
    • pp.35-42
    • /
    • 1997
  • An innovating technique of atomizer has been proposed to supply and to atomise molten materials. Both of a simple geometry of nozzle and an improved nozzle have been fabricated in the present study. With these nozzles, characteristics of the suction and disintegration have been empirically investigated. The important conclusions are as follows; In the case of a simple nozzle: 1) Although the sucking up and supplying of molten materials are available, the applications of powder metallurgy are limited. 2) It is concluded that the more air flow rate, $W_A$ or the shorter the height of air nozzle from the surface of supplied water, $L_h$, the more the atomizing mass of liquids, $W_L$. In the case of an improved nozzle: 3) The stable liquids can be supplied due to cut off the passage of surrounding air entrainment by air jets. 4) The atomizing mass of liquids, $W_L$ has affected not so much on the height of nozzle from the surface of supplied water, $L_h$ as that from the orifice, hc.

  • PDF

고층건축물의 피난경로 가압제연시스템 성능개선대책에 관한 연구 (A Study on Performance Improvement Measures of Pressurized Smoke Control Systems for Exit Passageways of High-Rise Buildings)

  • 손봉세;김진수
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.703-714
    • /
    • 2009
  • One of the biggest problems in smoke control systems for high-rise buildings is stack effect, but there are no recognized methods or measures to solve the problem of stack effect as yet. The stack effect can be overcome by forming the uprising current inside the stair hall properly, but there is a limit to the height in supplying into the stair hall the smoke control air volume to be supplied to a floor in case of escape from fire. The limit to the height can be extended by over-coming the stack effect by pressurizing the stair hall and the ancillary room simultaneously. It can also be anticipated that the stack effect can be overcome by connecting the air supply shaft to the stair hall at the top. As a result of computer simulations using a network type of tool, it is found that adequate performance can be achieved by pressurizing the stair hall only for a building of 190m or less, and up to 360m when pressurizing the stair hall and the ancillary room simultaneously. In all those cases, however, an overpressure venting damper is required which operates within a suitable range for venting the overpressure outside.

빙축열을 이용한 저온공조시스템 운전 특성 연구 (Study on operation characteristics of the cold air distribution systems with an ice storage tank)

  • 염한길;박병규;고득용
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

A Novel Air-cell Mattress Based on Approximate Anthropometric Model for Preventing Pressure Ulcer

  • Moon, In-Hyuk;Kang, Sung-Jae;Kim, Gyu-Seok;Mun, Mu-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1278-1282
    • /
    • 2005
  • Air mattress is now used widely to prevent the pressure ulcer by reducing the localized pressure peaks. In this paper an air-cell mattress and its pressure control method based on an approximate anthropometric model are presented. The air-cell mattress has eighteen cylindrical air cells made of porous material allowing air leakage to contribute in reducing the development of pressure ulcer by lowering the pressure peak, temperature and humidity. To determine an optimal air-cell pressure appropriate for each user, we divide the parts of the body into four sections such as head, trunk, hip, and leg. Then, the pressure of each section is independently calculated from the weight of each part based on the individual body height and weight and the approximate anthropometric model. Air supply system for the air-cell mattress is implemented by using four electronic solenoid valves and an air compressor, and it is driven by a real-time micro-controller. The experimental results with seven subjects shows that the proposed air-cell mattress is effective for the prevention of the pressure ulcer.

  • PDF

닫힌 그루브를 갖는 외부가압 공기 패드 베어링의 동특성 해석 (Dynamic Characteristics of Externally Pressurized Air Pad Bearings with Closed Loop Grooves)

  • 박광원;박상신
    • Tribology and Lubricants
    • /
    • 제33권6호
    • /
    • pp.309-314
    • /
    • 2017
  • This paper presents a theoretical investigation of the dynamic characteristics of externally pressurized air pad bearings with closed loop grooves. These grooves are made on the surface of bearings to reduce the number of supply holes so that manufacturing costs can be reduced. The semi-implicit method is applied to calculate the time varying pressure profile on the air bearing surface owing to the advantages of numerical stability and fast time tracing characteristics. The static pressure of the groove bearings is much higher than that without grooves, so the groove bearings can provide high load carrying capacity. The equation of motion considering vertical motion and tilting motion are also solved using the Runge-Kutta 4th order method. By combining the semi-implicit method and the Runge-Kutta method, fast calculations of the dynamic behavior of the air bearing can be achieved. The variations of bearing reaction force, air film reaction moment, height, and tilting angle are investigated for the step force input, which is 20% higher than the bearing reaction, when the nominal clearance is 6 mm. The effect of the groove width and the groove depth are investigated by calculating the dynamic behavior. The possibility of the air hammering with the depth of the groove is found and discussed.

Determination of an Optimum Orbiting Radius for an Oil-Less Scroll Air Compressor

  • Kim, Hyun-Jin;Lee, Yong-Ho;Kwon, Tae-Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권4호
    • /
    • pp.124-129
    • /
    • 2008
  • Design practice has been made on an oil-less scroll air compressor as an air supply device for a 2 kW fuel cell system where air pressure of 2 bar and flow rate of 120 liter/min are required. Basic structure of the scroll compressor includes double-sided scroll wrap for the orbiting scroll driven by two crankshafts connected to each other by a timing belt. These features can eliminate thrust surface which otherwise would produce frictional heat and jeopardize reliable operation of the orbiting scroll and the scroll element's deformation as well. This study focuses on optimum scroll wrap design; orbiting radius has been chosen as an independent design parameter. As the orbiting radius changes, scroll sizes such as scroll base plate and discharge port diameters change accordingly. Gas compression-related losses and mechanical loss also change with the orbiting radius. With a scroll base plate diameter of 120mm at most and discharge port of at least 10mm, the orbiting radius should be within the range of 2.5-4.0mm. With this range of the orbiting radius, it was estimated by performance analysis that the compressor efficiency reached to a maximum of ${\eta}_c$=96% at the orbiting radius of $r_s$=3.5mm for the scroll wrap height-to-thickness ratio of h/t=5.

폐색 저감형 산기관의 개발 및 적용성 평가 (A study on the Development and Evaluation of Sludge Occlusion Reduced Diffuser)

  • 김영훈;김관엽;이의종;남종우;이창하;전민정;김형수
    • 상하수도학회지
    • /
    • 제25권1호
    • /
    • pp.41-49
    • /
    • 2011
  • The diffuser which is conventionally adapted to MBR, has problem that decreasing the cleaning effect of membrane module by inflexible air supply due to the occlusion of sludge from diffuser hole. To solve this problem, diffuser structure of submerged module should be improved to discharge sludge which is flow into the diffuser for prevent occlusion in the diffuser. In this study, the structure of the diffuser was reformed to open lower part for preclusion the blocking. And the outlet diameter of the diffuser was drawn through the condition for the depth of water and air rate, to prevent air-leak condition of improved diffuser. Moreover, application is evaluated by comparing test with occlusion effect of the conventional and improved diffuser. From the results, air-water boundary changes are steady with changes of water depth and it shows linear relation about air rate. By using this linear numerical formula, the height of diffuser's outlet can be decided. Also, it displays that it can prevent the occlusion effect during the comparing test. Hereafter, if this diffuser is applied to practical MBR process, the occlusion problem of diffuser will be disappeared.

Numerical Analysis of Vertical Plate Absorber for Optimal Design

  • Yoon, Jung-In;Moon, Choon-Geun;Phan, Thanh-Tong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.252-262
    • /
    • 2004
  • A model of simultaneous heat and mass transfer process in absorption of refrigerant vapor into a lithium bromide solution of water-cooled vertical plate absorber. which was considered to the change of refrigerant vapor pressure along the plate width direction. was developed to evaluate the compactness of plate absorber and supply basis data for optimal design of plate absorber. The effects of plate interval as well as the effect of capacity for one piece of plate absorber on plate absorber size such as plate height. plate heating area and plate absorber volume have been investigated. It is confirmed that there is exist an optimal plate interval minimizing plate absorber volume. And the smaller capacity for one piece of plate absorber. the smaller plate absorber volume is obtained.

인체계측 모델을 이용한 욕창방지용 공기셀 매트리스의 개발 (Development of Air-cell Mattress for Preventing Pressure Ulcer Using Anthropometric Model)

  • 강성재;김규석;홍정화;류제청;김경훈;문무성;문인혁
    • 제어로봇시스템학회논문지
    • /
    • 제11권7호
    • /
    • pp.578-586
    • /
    • 2005
  • Air mattress is now used widely to prevent the pressure ulcer by reducing the localized pressure peaks. The pressure control method based on the anthrophometric model of an air-cell mattress developed in this study is presented. The air-cell mattress has 18 cylindrical air cells made of porous material allowing air leakage. Even though the air leakage can contribute to reducing the development of pressure ulcer by lowering the pressure peak, temperature and humidity, the air pressure changes with time and the desired air-cell pressure has to be determined as an optimal value for each user. To select the desired air-cell pressure, we first divide the parts of the body into four sections such as head, trunk, hip, and leg. Then, the pressure of each section grouped with air-cells is calculated from the weight of each part estimated from the individual height and body weight. Air supply system for the air-cell mattress is implemented by using four electronic solenoid valves and an air compressor, and it is driven by a real-time microcontroller. We experimented with five subjects of the contact pressure on skin. The experimental results show that the proposed air-cell mattress is effective for the prevention of the pressure ulcer.