옥내화재시 급기구의 높이에 따른 암흑화에 관한 연구 (A Study of Obscuration on Height of Air Supply in Indoor Fire)

  • 이창섭
    • 한국화재소방학회논문지
    • /
    • 제15권3호
    • /
    • pp.1-6
    • /
    • 2001
  • 옥내화재에서 높이에 따른 암흑화의 정도를, 본 연구를 목적으로 제작된 스모크박스를 이용한 실험을 통해 측정하였다. 연기로 인한 암흑화의 정도는 높이에 따라서 결정되는데, 높은 곳일수록 그 정도가 심했다. 그러나 급기구가 있는 높이에서는 암흑화가 심해지는 변이가 일어났다.

  • PDF

반송동력과 건물층고 저감형 공조시스템 개발 (Development of HVAC System to Lower the Conveyance Energy and Building Height)

  • 김정엽;신현준
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.116-125
    • /
    • 2003
  • The new HVAC system to lower the conveyance energy and building height using IAV (Increasing Air Volume) technique is developed. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy, size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 per-centage.

Development of HVAC System to Lower the Conveyance Energy and Building Height

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권1호
    • /
    • pp.31-43
    • /
    • 2005
  • The new HVAC system is developed to lower the conveyance energy and building height using IAV(Increasing Air Volume) technique. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy. size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 percentage.

공동주택 화장실의 급기구 및 배기팬 설치 위치에 따른 환기효과에 관한 연구 (A Study on the Ventilation Effect by Establishment Location of Supply Opening and Exhaust Fan of Bathroom in Apartment House)

  • 함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2002년도 추계학술발표대회
    • /
    • pp.321-326
    • /
    • 2002
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken Into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$m^2$, were made and installed in a laboratory, These ventilation mock-ups were available for control of air supply and exhaust, and the size of supply openings were 40cm$\times$1cm, 40cm$\times$3cm, 40cm$\times$5cm. They were installed at five positions, spaced 40cm at a height of 25cm from the floor. and the position of exhaust fans were four corners and center Exhaust fan established each one on corner of the ceiling and one in center. As result that measure ventilation effect by each condition, size of hole that supply air is big, and ventilation effect took effect to be good establishment location is low, Also, distance of exhaust fan is far with hole that supply air, ventilation effect took effect by superior thing.

  • PDF

공동주택 화장실의 기계 환기시스템에 관한 연구 (A Study on the Mechanical Ventilation System of Bathroom in Apartment House)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제12권3호
    • /
    • pp.141-148
    • /
    • 2001
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$\textrm{m}^2$, were made and installed in a laboratory. These ventilation mock-ups were available for control of air supply and exhaust, and the sizes of supply openings were 40cm${\times}$1cm, 40cm${\times}$3cm, and 40cm${\times}$5cm. They were installed at five positions, spaced 45cm at a height of 5cm from the floor. The exhaust fan was designed for its operating voltage to be set to five steps(100V, 130V, 150V, 180V and 220V) in order to control its air flow rates. When the size and position of each supply opening were changed with the wind velocity of the exhaust fan set to the step 5, the ventilation rates were measured and analyzed by the concentration decay method of tracer gas method, in order to present an efficient mechanical ventilation system. The results of the study revealed that the ventilations rates would increase in the presence of supply openings, compared to the absence of supply openings, and that the larger the size of the supply opening, the more the ventilation rates. Therefore, it was found necessary to take air supply into consideration.

  • PDF

공동주택 화장실의 급기구 및 배기팬 설치위치에 따른 환기효과에 관한 연구 (A Study on the Ventilation Effect by Various Location of Air Intake and Exhaust Fan of Bathroom in Apartment Housing)

  • 함진식;이광명
    • 한국주거학회논문집
    • /
    • 제15권5호
    • /
    • pp.77-84
    • /
    • 2004
  • The mock-ups of ventilation system, which has been widely adopted for the bathroom with the area of 100 $m^2$ apartment housing, were established and tested to design mechanical ventilation for apartment housing bathroom where air supply exhaust are relatively important. These ventilation mock-ups were capable of controlling intake and exhaust, which has the size of supply openings as 40cm${\times}$1cm, 40cm${\times}$3cm, 40cm${\times}$5cm. They were established at five locations, spaced 40cm from each other at a height of 25cm from the floor. The exhaust fans were located at four corners and center of the ceiling. The results this ventilation effect measurement by different condition are showing that when the size of air supply is bigger and the location is lower, the effect of ventilation was relatively higher. In addition, as the distance between exhaust fan and air supply was farther, the ventilation effect were getting highly efficient.

공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구 (Numerical Study on Air Egress Velocity of Ancillary Room Pressurization Systems in Apartment Fires)

  • 김병준;양영;신원규
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.78-86
    • /
    • 2020
  • 본 연구에서는 공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관하여 수치해석을 수행하였다. 수치해석을 통해 댐퍼의 급기량과 방화문에서의 방연풍속의 관계식을 선형적으로 나타내었고 국가화재안전기준인 방연풍속 0.7 m/s를 만족하는 댐퍼의 최소유량을 선정할 수 있었다. 댐퍼의 최소유량을 적용하여 댐퍼의 급기 방향과 설치 높이에 따라 방연속도를 분석하였다. 댐퍼의 급기 방향이 상향인 경우와 댐퍼가 높게 설치되었을 때 댐퍼의 급기 방향이 하향인 경우보다 방화문 상부에서 더 큰 방연풍속을 나타내었고 누출된 연기 농도가 더 낮은 것을 확인할 수 있었다. 따라서 방화문 상부에서 큰 방연풍속을 확보하는 것이 제연에 더 효율적일 것으로 판단된다.

공동주택 온수난방 시스템의 적정 열공급을 위한 배관망 시뮬레이션 (Simulation of Pipe Network for Optimum Heat Supply in the Hot Water Heating System of Apartment House)

  • 김주용;민만기;최영돈
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.157-168
    • /
    • 1993
  • Pipe network of hot water heat supply system in an apartment house was analyzed. Flowrate and supply heat capacity of each household in which constant flowrate balancing valve is installed in a single zone system were calculated and the results were investigated. In the existing piping system, the non-uniformity of heat supply with floors due to the static pressure and temperature difference between supply main and return main can not be avoided and this tendency get intense with the increase of the height of building. The non-uniformity of heat supply can be prevented by the installation of balancing valve at each household, however if the performance of supply pump is not sufficient to overcome the energy loss due to the installation of balancing valve for constant flow rate or if the selection of the valve capacity is not adequate, the valves will may lose their controllability.

  • PDF

IMM 기법을 이용한 기압고도계 오차 식별 필터 (Interacting Multiple Model Baro-Error Identification Filter)

  • 황익호;나원상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.290-291
    • /
    • 2007
  • Barometers can provide height information steady but its accuracy becomes poor as the air data varies due to the vehicles's moving or time's elapsing. In order to keep the accuracy in spite of the air data changes, we propose a filter for the identification of baro-errors. The baro-errors mainly consist of bias and scale factor errors which gradually varies as the air data varies. With GPS height measurements, the scale factor and bias estimator is designed by applying the interacting multiple model (IMM) filtering technique to the baro-error random walk model. The resultant estimates are used to compensate current baro-measurement to supply accurate measurements steadily.

  • PDF

Zero-Scan-Back 기준 고도 생성 필터 (Zero-Sean-Back Reference Height Generation Filter)

  • 황익호;나원상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.386-388
    • /
    • 2007
  • In many applications of UAVs flying in low altitude, the steady supply of accurate height measurements is very important for the UAVs to complete their mission successfully. In order to do this, a barometer or GPS height measurements are widely used. However, because these two sensors have their limitations in the application environment, a method for fusing these two measurements to produce reference heights are required. In this paper, a reference height generation filter is designed for UAV(Unmanned Air Vehicle) applications. The barometer errors originated by the change of the atmospheric environment are modeled using random walk models, and then the errors are identified and compensated through the ZSB(zero-scan-back) filter algorithm using the GPS height measurements. The performance of the proposed filter is demonstrated by realistic simulations.

  • PDF