• Title/Summary/Keyword: Air stripping

Search Result 66, Processing Time 0.03 seconds

Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater (축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향)

  • Whang, Gye-Dae;Cho, Young-Moo
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.

Effect of Operational Parameters on the Ammonia Stripping (암모니아 스트리핑에 미치는 운전인자의 영향)

  • Seo, Jeong-Beom;An, Kwang-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.9
    • /
    • pp.935-939
    • /
    • 2006
  • The biological nutrient removal from domestic wastewater with low C/N ratio is difficult. Therefore, this study was performed to examine effect of operational parameters such as air supply, hydraulic retention time, pH on the nitrogen removal by ammonia stripping and to increase influent C/N ratio without required carbon source. The ammonia stripping system used for the bench-scale experiment in laboratory had a dimension of 15 cm diameter and 150 cm height. The ammonia stripping reactors were classified into two types, type AS I and type AS II, according to there using or not media. Results of the research showed that the T-N removal efficiency of AS I using plastic media is slightly higher than AS II without media. In experimental condition of air supply 30 L/min and pH 12.5, T-N removal efficiencies increased as HRT of ammonia stripping reactor became longer from 8 hr to 36 hr. In experimental condition of HRT 36 hr, it was also found that the T-N removal efficiencies improved through increase of air supply. On the other hand, C/N ratio of wastewater was increased from average 3.9 to 5.4 by ammonia stripping.

APPLICATION OF A PILOT-SCALE FLUIDIZED-BED REACTOR FOR THE DECONTAMINATION OF GROUNDWATER

  • Ohlen, Ken;Lee, Seong-Taek;Hegemann, Wemer;Jang, Yong-Geun
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.77-80
    • /
    • 2001
  • Groundwater, contaminated predominantly with aromatic compounds and chlorinated ethylene, could be biologically treated in a fluidized-bed reactor with immobilized cells. The decomposition efficiency for the aromatics was over 90% at the retention time of 2.5 h. The chlorinated ethylenes, especially trichloroethylene (TCE) and cis-dichloroethylene (DCE), could be decomposed only insufficiently. No anaerobic methane formation was observed for this groundwater even at a very low dissolved oxygen (DO) concentration of 0.75 mg/L. The variation of DO concentration resulted in an optimal value of 1.5 mg/L. The recycle of air waste could increase the utilization of oxygen. The amount of low boiling pollutants stripped out remained constant with the recycle, while for the higher boiling pollutants the stripping slightly increased. Using air instead of oxygen increases the flow rate of air waste, which is connected to a higher stripping of pollutants. In this investigation, the pollutant concentration in the air waste remained constant. The stripping of main pollutants did not exceed 0.3 %.

  • PDF

Methane Recovery and Carbon Dioxide Stripping by MEA Solution the Autocirculation Bubble Lift Column Reactor (내부순환식 기포탑 반응기 상에서 MEA (monoethanolamine) 용액에 의한 이산화탄소 분리 및 메탄회수)

  • Lee, In-Hwa;Kim, Sun-Yil;Park, Ju-Young
    • Applied Chemistry for Engineering
    • /
    • v.18 no.3
    • /
    • pp.239-244
    • /
    • 2007
  • For the simultaneous methane recovery and $CO_2$-stripping, we have been developed dual vent auto circulation bubble lift column reactor, and evaluate optimum conditions for monoethanolamine (MEA) solutions as a $CO_2$ absorbent. At the 5 wt% MEA solution, we investigated the pH change during $CO_2$-stripping and absorption reaction, $CO_2$-stripping rate with reaction time, methane recovery efficiency for various inflow rates of air, $CO_2$-stripping rate for flow liquid over flow height, and $CO_2$-stripping dependency on the temperature of absolvent solutions. The suggested optimum conditions for $CO_2$ recovery with MEA in the dual vent auto circulation bubble lift column reactor were 40 mm over flow liquid height, 1.5 L/min of air inflow rate, and $25^{\circ}C$ of absorbent solution temperature.

A Study on the Decompressed Ammonia Stripping from Ammonia Contained Wastewater (폐수의 감압 암모니아 탈기에 관한 연구)

  • 신대윤;오유경
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.93-99
    • /
    • 2001
  • This study aims at finding out pertinent reaction conditions for treating high concentration ammonia contained in N-chemical factory wastewater with decompressed ammonia stripping method that was designed. And it also tries to investigate adsorption capability of removed ammonia to soil. The results from experiments are as follows ; 1. The removal rate of N $H_3$-N of synthetic wastewater was under 85% at pH 10 with decompressed ammonia stripping method. The reaction time in pressure 360 mmHg at pH 11 and 12 was shorter than in 460 mmHg, and the removal rate of N $H_3$-N with decompressed ammonia stripping method at 9$0^{\circ}C$ was 11~15% higher than air stripping 2. The optimum conditions for decompressed ammonia stripping with synthetic sample were shown as pH 12, temperature 9$0^{\circ}C$, internal reaction pressure 460 mmHg and reaction time 50 minutes. These conditions were applied to treat the wastewater containing organic-N 290.5mg/$\ell$, N $H_3$-N 168.9mg/$\ell$, N $O_2$-N 23.2mg/$\ell$, N $O_3$-N 252.4mg/$\ell$, T-N 735mg/$\ell$. Organic-N turned out to be removed 60%, the removal rate of N $H_3$-N IS 94%, T-N is 50%. But N $O_2$-N and N $O_3$-N were increased with 7.8% and 14.9% respectively. 3. The CO $D_{Sr}$ removal rate in decompressed ammonia stripping reaction was 42% and S $O_4$$^{2-}$ was removed 8.2%. It was turned out caused with higher pH and thermolysis. 4. In soil adsorption of ammonia desorbed from the decompressed stripping process of wastewater, the recovery rate was 76% in wet soil.

  • PDF

Combination of air stripping and biological processes for landfill leachate treatment

  • Smaoui, Yosr;Bouzid, Jalel;Sayadi, Sami
    • Environmental Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.80-87
    • /
    • 2020
  • Landfill waste decomposition generates a dark effluent named, leachate which is characterized by high organic matter content. To minimize these polluting effects, it becomes necessary to develop an effective landfill leachate treatment process. The objective of this study was to evaluate the performance of an innovative approach based on air stripping, anaerobic digestion (AD) and aerobic activated sludge treatment. A reduction of 80% of ammonia and an increase of carbon to nitrogen ratio to 25 were obtained, which is a suitable ratio for AD. This latter AD was performed in fixed bed reactor with progressive loading rate that reached 2 and 3.2 g COD/L/d for the raw and diluted leachate (1:2), respectively. The anaerobic treatment led to significant removal of chemical oxygen demand (COD) and biogas production, especially for the diluted leachate. The COD removal was of 78% for the raw leachate and a biogas production of 4 L/d with 70% methane content. The use of the diluted leachate led to 81% of COD removal and 7 L/d biogas with 75% methane content. It allowed a removal of 77% COD and more than 97% of the organic compounds present in the initial leachate sample.

Spalling Resistance of High Strength Concrete Using Non-Stripping Form (비탈형 거푸집에 의한 고강도 콘크리트의 폭렬방지)

  • You, Ji-Young;Han, Chang-Pyung;Jee, Suk-Won;Han, Min-Cheol;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.865-868
    • /
    • 2008
  • As a part of a series of study, this study reviewed the fire proof characteristics of high performance concrete RC column members using non-stripping form that accompanied metal lath lateral confinement to prevent spalling of high performance concrete which is increasingly used recently, and the results are as follows. Flow and air amount both satisfied target range, and compressive strength, over 80MPa at age 28 days, showed high strength range. As for spalling characteristics, in the case of plain in which no fiber is mixed, severe spalling occurred, and in the case of 0.05% nylon("NY" hereinafter)+polypropylene("PP" hereinafter) fiber mixture, only surface area experienced partial spalling. Regarding non-stripping form changes, both non-stripping 25-20 and non-stripping 50-20 experienced spalling at finish material area, and non-stripping 50-20 showed better spalling proof performance than non-stripping 25-20. In the case of non-stripping 50-40, spalling was prevented, and while mass reduction rate was less than 10%, its temperature hysteresis showed the most excellent fire proof performance with base metal surface area maximum temperature $376.1^{\circ}C$.

  • PDF

Continuous Removal of Nitrate and Coliform using Bipolar ZVI Packed Bed Electrolytic Cell (영가철 충진 복극전해조를 이용한 질산성질소 및 대장균의 연속식 제거)

  • Jeong, Joo-Young;Park, Jeong-Ho;Choi, Won-Ho;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.651-658
    • /
    • 2011
  • Nitrate is a common contaminant in industrial wastewater and ground water. The maximum contaminant level set by EPA for nitrate of 10 mg/L as N. In this study, nitrate was removed using bipolar ZVI packed bed electrolytic cell that maximized the contact area between each electrode and contaminants under 600 V. Also this study investigates the simultaneously deals with removal of ammonia by operating air stripping tower. In addition to the air stripping also helped to precipitate iron ions to the form of iron oxides. Bipolar ZVI packed bed electrolytic cell was also effective in removing coliform by electrical power. In the continuous experiments for the simulated wastewater (initial nitrate for 25 mg/L as N), maximum 96.3% removal of nitrate was achieved in the applied 600 V at the flow rate of 6 mL/min.

Removal and Photodecomposition of Haloacetonitriles of Disinfection byproducts (소독부산물인 Haloacetonitriles의 광분해 및 제거)

  • Kim, Jong-Hyang;Lee, Myung-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.224-227
    • /
    • 2005
  • 먹는물에서 염소소독 부산물로서 휘발성유기화합물인 디클로로아세트니트닐(DCAN), 트리클로로아세트니트릴(TCAN), 디브로모아세트니트릴(DBAN), 브로모클로로아세트니트릴(BCAN)의 4종류의 물질을 대상으로 탈기법(air stripping) 및 탈기법(air stripping)과 자외선에너지($8\;W{\times}6$)를 이용하여 분해시험을 행하였다. 물질들의 확인은 가스크로마토 그래프, 이온크로마토그래프 그리고 자외선분광광도계를 사용하였다. TCAN은 탈기법 이용한 방법에서 제거가 되었으며, DBAN과 BCAN에서는 자외선에너지에 의해 분해가 되었다.

A Study on Economics of Air Stripping Towers and Activated Carbon Adsorption(Multicomponent System) (충전탑 공기 스트리핑과 활성탄 흡착의 경제성에 관한 연구(다중성분계))

  • Yoo, Ho Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.4
    • /
    • pp.33-42
    • /
    • 1998
  • The optimum design and preliminary cost estimations of air stripping towers ASTs with granular activated carbon adsorption (GAC) systems as the off-gas treatment were done and compared to liquid-phase GAC system. The optimum design and preliminary cost estimations were done for either single or multicomponent systems. A computer program was developed for this study. 15 single compounds and their multicomponent systems were studies. Even with off-gas treatment, AST was generally a less expensive process for treatment of volatile organics than liquid-phase GAC system. Treatment costs of small systems were sensitive to system capacity. Accumulative effect of treatment costs was found in multicomponent systems. The cost of a multicomponent system was highly dependent on the least strippable component in ASTs even with gas-phase GAC or the least adsorbable component in liquid-phase GAC system.

  • PDF