• Title/Summary/Keyword: Air spring

Search Result 836, Processing Time 0.026 seconds

Health Risk Assessment of Heavy Metals in Fine Particles Collected in Seoul Metropolitan Area (서울북부 지역 미세먼지에 함유된 유해 중금속의 분석 및 건강위해성평가)

  • Park Eun-Jung;Kang Misun;You Dae-Eun;Kim Dae-Seon;Yu Seung-Do;Chung Kyu-Hyuck;Park Kwangsik
    • Environmental Analysis Health and Toxicology
    • /
    • v.20 no.2 s.49
    • /
    • pp.179-186
    • /
    • 2005
  • Particulate materials (PM) less than 10 ${\mu}m$ in diameter are of special interest in air pollution because they are respirable and responsible for the increasing mortality rate of lung cancer and cardiovascular diseases. These particles are often referred to as $PM_{10}$ and they are divided into a coarse fraction and a fine fraction which is also often referred to as $PM_{25}$. In this study, we monitored the TSP, $PM_{10},\;PM_{2.5}$ concentration of ambient air collected in northern part of Seoul in early spring and measured the concentration of heavy metals; Cr, Mn, Zn, As, Cd, and Pb. All the heavy metals were found in the collected particles and the concentrations were variable in the $PM_{10},\;and\;PM_{2.5}$ respectively. The detected concentration ranges were Cr: $ND\~2,889ng/m^3,\;Mn:2.4\~257.9ng/m^3,\;Zn:ND\~353.7ng/m^3,\; As:ND\~22.3ng/m^3,\;Cd:0.1\~2.9ng/m^3,\;and\;Pb:ND\~392.2ng/m^3$ in fine particles. Heavy metal toxicity of the particles were also tested in $H_9C_2$ cell line derived from rat cardiomyocytes. As for the results of health risk assessment calculated by unit risk of IRIS, heavy metals in ambient air of Seoul metropolitan area were found to be responsible for the increase of total excess cancer risk. Among them, chromium (hexavalent) was found to be the most risky in fine particles of ambient air collected in the northern part of Seoul in early spring.

Design of a 50kW Class Rotating Body Type Highly Efficient Wave Energy Converter (50kW급 가동물체형 고효율 파력발전시스템 설계)

  • Cho, Byung-Hak;Yang, Dong-Soon;Park, Shin-Yeol;Choi, Kyung-Shik;Park, Byung-Chul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.4
    • /
    • pp.552-558
    • /
    • 2011
  • A 50 kW class rotating body type wave energy converter consisted of two floating bodies and a PTO (Power Takeoff) unit is studied. As an wave energy extractor, the body is designed to have a VLCO (Variable Liquid-Column Oscillator) having a liquid filled U-tube with air chambers. Owing to the oscillation of the liquid in the U-tube caused by the air spring effect of the air chambers, the amplitude of response of the VLCO becomes significantly amplified for a target wave period. The PTO converts the rotational moment introduced from the relative motion of the hinged bodies to an hydraulic power by means of a cylinder. A high pressure accumulator, hydraulic motor and a generator are equipped in the PTO to convert the hydraulic power to electric power. A control law for adjusting the oscillation period of the VLCO is proposed for the efficient operation of the VLCO with various wave conditions. It is found that the effect of the air spring has an important role to play in making the oscillation of the VLCO match with the ocean wave. In this way, the wave energy converter equipped with the VLCO provides the most effective mode for extracting energy from the ocean wave.

The Fukushima Nuclear Disaster and Nuclear Safety Systems in Korea (후쿠시마 원전사고와 한국의 원전안전정책)

  • Choi, Ye-Yong;Suzuki, Akira;Lee, Sang-Hong;Paek, Do-Myung
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.3
    • /
    • pp.226-233
    • /
    • 2011
  • Exactly 25 years after the Chernobyl nuclear disaster, 11th of March 2011 the Fukushima nuclear accident occurred in Japan and was ranked at level 7 same to the Chernobyl. A Korean and Japanese joint civil survey was conducted around Fukushima on April 13-17. The radiation survey data clearly shows a large hotspot area between 20 km and 50 km radius north and west direction from the accident reactors, with the highest radiation recorded being 55.64 ${\mu}Sv/hr$ in the air, 99.89 ${\mu}Sv/hr$ in the surface air, and 36.16 ${\mu}Sv/hr$ in a car, respectively. 3.65 ${\mu}Sv/hr$ in the air and 6.89 ${\mu}Sv/hr$ in the surface air were detected at the playground of an elementary school in Fukushima City. Spring came with full cherry blossoms in Fukushima, but it was silent spring of radiation contamination. Interviews with Fukushima nuclear refugees reveal serious problems about Japanese nuclear safety systems, such as there was no practical evacuation drill within 1-10 km and no plan at all for 10-30 km areas. Several reforms items for Korean nuclear safety system can be suggested: minimization of accident damage, clear separation of regulatory and safety bureaus with a new and independent administrating agency, community participation and agreement regarding the safety system and levels, which is the major concern of 80% Korean. To tackle threats of nuclear disaster in neighboring nations like China, a new position entitled 'Ambassador for nuclear safety diplomacy' is highly necessary. The nuclear safety of Korea should no longer be the monopoly of those nuclear engineers and limited technocrats criticized as a 'nuclear mafia'.

Study of Examples for Air Bag Non-deployment Including Rear Collision and Failure Phenomenon by Damage of Control Parts in Vehicle Air Bag (자동차 에어백의 제어부품 불량에 의한 고장현상 및 후방 추돌에 관련된 에어백 미전개에 대한 사례 연구)

  • Lee, Il Kwon;Kim, Young Gyu;Moon, Hak Hook
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.102-106
    • /
    • 2012
  • The purpose of this paper is to study the failure cases in relation to system of Air Bag in vehicle happened in the field. In the first example, it was separated the soldering parts connected the wire pin between air bag module and clock spring of air bag. Whenever the pin shake by the car's vibration, the driver verified the malfunction phenomenon appeared air bag warning lamp on instrument panel in front of driver's seat. in car inside room. The second example, it verified the warning lamp lighting phenomenon of air bag by produced the circuit plate non-contacting of single an element in air bag electronic control unit. The third example, it verified the light of air bag warning indicator lamp by separated with soldering parts connecting inner pin and resistance terminal of seat belt pretensioner using passenger seat. The fourth example, when the passenger car crash a back of truck, the former bumper get jammed under the latter as the roof height of car low less than that. Therefore, the impact of Car's collision verified that don't transfer with body frame of vehicle because of no attachment impact sensor in it.

Chemical Compositions Trends of Airbone PArticles at Kunsan (군산지역 부유분진의 계절적 농도변화와 화학적 조성에 대한 연구)

  • 오진만;김득수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.6
    • /
    • pp.475-485
    • /
    • 2001
  • The presence of airborne particles in the earth atmosphere expert important controls on the global climate because of their effects on the radiative balance. However, there are major uncertainties associated with the direct and indirect radiative effects of aerosols. In addition, their physicochemical properties cannot only the decline of air quality but also damage human health. Airborne particles were collected by two different commercial air samples, high volume sampler(for TSP) and low volume sampler(for P $M_{10}$ ) at the campus of Kunsan National University during February to September, 2000. In most cases, TSP and P $M_{10}$ were sampled once a week for the duration of 24 hours from 9:00 a.m. In addition samples were collected more intenisve, when the yellow dust was expected. Each sample was analyzed for pH and major ions concentration (C $l^{[-10]}$ , S $O_4$$^{2-}$, N $O_3$$^{[-10]}$ , N $a^{+}$, N $H_4$$^{+}$, $K^{+}$, $Mg^{2+}$, $Ca^{2+}$) by ion chromatography and atomic absorption spectrophotometry. Acidity (pH) of TSP and P $M_{10}$ ranged from 5.09 to 8.51 and from 6.22 to 7.54, respectively. The concentrations of airborne particles were found to satisfy both the short and long-term air quality standards during the sampling period. If the ratio of ionic concentrations originating from None sea salt(Nss) to sea salt(ss) in aerosol samples was concerned, it was found that the ionic concentrations from marine environment contributed dominantly in total mass concentration in the airborne particles. When seasonal trends were examined, the TSP concentrations in spring were higher than those of other seasons. It may result form frequent occurrences of yellow dust and during the spring season. The concentration ratio of P $M_{10}$ to TSP ranged from 0.78 to 1 during the sampling period. pH in the airborne particle was highest during spring, but the other seasons maintained almost same level. These results suggest that alkaline species in yellow dust can directly neutralize aerosol acidity. During spring season, yellow dust could be a positive factor that can defer the acidification of surface soil and water by neutralizing acidic aerosols in the atmosphere.osphere.

  • PDF

A Study of Pneumatic Reaction Force of Air Chamber for an OWC Type Wave Energy Device by Forced Heave Experiments (강제동요시 OWC형 파력발전 공기챔버의 공기반력 실험연구)

  • Hong, Seok-Won;Choi, Hark-Sun;Lew, Jae-Moon;Kim, Jin-Ha
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.11-17
    • /
    • 2005
  • The effect of frequency and amplitude of the OWC (Oscillating Water Column) motion on the nonlinear reaction forces in an air duct are studied experimentally. Experimental owe model is idealized as a simple circular cylinder with an orifice type air duct located at the middle oj the top rid. Reaction forces due to forced heave oscillation are measured and analyzed. By subtracting the effect of inertia forces and restoring forces, pneumatic damping force and added spring force are deduced. The effects of the frequency and amplitude of the heave motion are discussed. Also, the effects of solidity of the duct on the reaction forces are discussed.

The Characteristics of VOCs and Formaldehyde emitted from the furnitures and frame material of windows and doors (가구 및 목창호재에서 방출되는 유해화학물질의 특성)

  • Park, Yong-Seung;Yoo, Bok-Hee;Cho, Hyun;Hong, Cheon-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.315-318
    • /
    • 2004
  • In recent days, IAQ(Indoor Air Quality) is regarded as one of the most important environmental factors as well as thermal and acoustic comfort. The purpose of this study was to estimate on effect of indoor air pollution from VOCs and formaldehyde emitted by building materials. As the results, we knew that concentration of Toluene, Xylene, Styrene and HCHO emitted from the furnitures and frame material of windows and doors are high emission factors on indoor air pollution.

  • PDF

Finite Element Analysis of Diaphragm Type Air Springs considering the Variation of Fiber Angles (섬유의 적층각을 고려한 다이아프램형 공기 스프링의 유한요소 해석)

  • Lee, Hyeoun-Guk;Kim, Se-Ho;Heo, Hun;Kim, Jin-Yeong;Chung, Su-Gyo
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.04a
    • /
    • pp.29-33
    • /
    • 1999
  • this paper concerned with the stress analysis of a diaphragm-type air spring which consists of rubber linings nylon reinforced rubber composite. The analysis is carried out with a finite element method developed to consider the orthotropic properties geometric non-linearity and contact between an air bag and a bead ring The material properties are evaluated with the Halpio-Tsai equations and the rule of mixture. The analysis results demonstrate the variation of the outer diameter the fold height and the vertical force with different models to the design a proper diaphragm air springs.

  • PDF