• 제목/요약/키워드: Air slit

검색결과 89건 처리시간 0.026초

설계 조건에 따른 7mm 직경 핀-관 열교환기의 성능비교 (Performance Comparison of 7mm Fin-Tube Heat Exchangers for Various Design Conditions)

  • 장근선;김혁;홍석률;김영재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.633-638
    • /
    • 2006
  • This study presents the air side heat transfer and friction characteristics of fin-tube heat exchangers with various fin types. A total of 8 samples of heat exchangers are tested. Fin patterns tested are slit, louver and plate fins. Each fin type has three cases of number of tube rows(N=1, 2, 3) and two different fin pitches. The results are plotted in terms of Colburn j-factor and friction factor f with respect to Reynolds number in the range of 200 to 510.

  • PDF

가정용 가스 냉난방기용 연소기의 성능개선 연구 (Enhancement of Burner Performance of Household Gas Fired Absorption Chiller/Heaters)

  • 윤영석;유현석;김태환;이중성;한정옥
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.111-115
    • /
    • 1999
  • In order to enhance the burner performance of household gas fired absorption chiller/heaters, the operating condition(excess air $\approx$ 10%) of the burner currently being used was required to be optimized. In this regard, we examined where the $CO_{\min}$. emission limit was located between blow off and yellow tip limit and how much amount of excess air was exhausted by means of observing blow off and yellow tip limit. It was found that the $CO_{\min}$ limit(excess air ${\approx}$ 4%) was determined near the yellow tip limit. The effect of exhaust pressure on the $CO_{\min}$. limit was that, if exhaust pressure was higher than that in steady condition, higher air blower fan rpm is demanded to maintain the $CO_{\min}$ limit. Therefore, it was necessary to optimize the operating condition of burner in terms of a thermal efficiency and safety.

  • PDF

Cathode에 따른 소형 PEM 연료전지의 성능 변화 (Performance of the Small PEMFC according to Cathode)

  • 이세원;이강인;박민수;주종남
    • 한국수소및신에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.283-290
    • /
    • 2008
  • In this paper, experiments with an air-breathing proton exchange membrane fuel cell (PEMFC) for mobile devices were carried out according to cathode conditions. These conditions are defined by the cathode flow field plate type (the channel type, the open type) and the cathode surface direction. Single-cell and 6-cell stack were used in the experiments. The experimental results showed that the open-type cathode flow field plate gave a better performance than the small channel type. In the experiments related to the direction of the slits on the cathode flow field plate, the horizontal slit cell was better than the vertical one. With respect to the cathode surface direction, when the cathode surface is placed in the direction normal to the ground, the PEMFC generated more stable power in the mass transport loss region. Since stable power in the mass transport region is closely related to the air supply, computational fluid dynamics (CFD) analysis for air-breathing PEMFC of different cathode surface directions was performed.

Heat Transfer Characteristics of Individual Row of Fin and Tube Heat Exchangers

  • Chang Keun-Sun;Kweon Young-Chul;Kim Young-Jae;Jeong Ji-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권2호
    • /
    • pp.49-56
    • /
    • 2006
  • Heat transfer performances of individual row of two-row fin and tube heat exchangers are experimentally investigated. Tested are four heat exchangers which are geometrically identical with the exception of fin shape, slit or louver, and that the fins between the first row and the second row are connected or separated. The tube diameter and fin spacing of the heat exchangers examined are 7mm and 1.4mm, respectively. All thermal fluid measurements are made using a psychrometric calorimeter. In order to evaluate air-side heat transfer coefficients of individual rows, tube-side water flow rates of individual rows are independently controlled such that the water-side temperature drops in each row remain at $5^{\circ}C$. Frontal air velocity varies in the range from 0.7m/s to 2.5m/s. Heat transfer coefficients are presented in terms of Colburn ${\jmath}-factor$. The results show that the heat transfer coefficient of the upstream row is larger than that for the downstream row at low Reynolds numbers.

냉방용 팬코일 유닛 열교환기의 열전달 및 압력강하 특성 실험연구 (Experimental Study on Heat Transfer and Pressure Drop of Heat Exchangers for Cooling Fan Coil Unit)

  • 권영철;고국원;권정태
    • 한국산학기술학회논문지
    • /
    • 제9권3호
    • /
    • pp.599-604
    • /
    • 2008
  • 본 연구에서는 냉방운전 시에 팬코일 유닛에 사용되는 핀-관 열교환기의 공기측 열전달 능력과 압력강하를 실험을 통하여 조사하였다. 실험을 위하여 칼로리미터와 항온수조를 이용하였다. 사용된 핀은 슬릿핀이며 5종 열교환기에 대해 배관회로와 실험조건을 변화하면서 실험하였다. 공기-물 정격유량에서의 냉방능력은 열교환기 공급 물온도가 낮은 조건이 우수하였으며, 배관회로에 따른 냉방능력은 배관 내 물흐름이 U형보다 ㄹ형인 경우에 더 크게 나타났다. 물유량이 증가할수록 냉방능력은 일정비율로 증가하였으며, 열교환기 공급 물 온도가 낮을 때 우수하였다. 공급 물 온도가 낮은 조건에서 많은 응축수가 생성되어 공기측 압력강하는 크게 나타났다.

급기가압 제연설비의 내부 유동특성에 대한 수치해석 (Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System)

  • 고권현
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.52-58
    • /
    • 2017
  • 본 연구에서는 급기가압에 따른 건축물 내부의 공기유동에 대한 수치해석을 수행하고 거실, 부속실 및 계단실 간의 차압분포 및 유동 특성을 분석하였다. 유동 해석은 유효누설면적을 측정하기 위해 제작된 누기율 시험설비에 대하여 수행하였으며, 급기가압에 따른 각 실의 압력 및 유속분포 등을 분석하였다. 본 해석에서 공기의 누설은 유효누설면적을 갖는 얇은 틈새를 방화문과 창문에 위치시키는 방법으로 모사하였다. 이러한 방법을 이용한 해석은 계단실과 부속실 간의 차압에 대한 기존 실험의 결과를 적절히 예측하였다. 해석 결과를 통해 국부적인 누설이 급기가압 제연 설비의 전체적인 유동 패턴 및 압력 분포에 큰 영향을 미치지 않음을 확인하였다. 거실-부속실 문 단면에서의 평균속도가 방연풍속에 대한 국가화재안전기준을 만족하였으나 문의 상부와 같은 국부적인 위치에서 부속실로의 유출이 발생할 수 있음을 확인하였다.

Experimental Study for Defects Inspection of CFRP Using Laser-Generated Ultrasound

  • Lee, Joon-Hyun;Park, Won-Su;Byun, Joon-Hyung
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.41-45
    • /
    • 2006
  • The fabrication process of fiber placement system of carbon fiber reinforced plastic (CFRP) requires real time process control and reliable inspection to ensure quality by preventing defects such as delamination and void. Therefore, novel non-contact inspection technique is required during the non-destructive evaluation in a fiber placement system. For the inspection of delamination in CFRP, various methods to receive laser-generated ultrasound were applied by using piezoelectric transducer, air-coupled transducer, wavelet transform and scanning laser ultrasonic technique. Laser-generated ultrasound was received with a conventional piezoelectric sensor in contacting manner. Then signal characteristics due to defects were analyzed to find a factor for detecting defects. Air-coupled transducer was used for reception of laser-generated guided wave using linear slit array in order to generate high frequency guided wave. And line scan technique was used to confirm the capability of on-line application. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer. The first peak of the frequency spectrum under 100kHz in the delamination region is higher than in the sound region. By using this feature, the line scanned frequency data were acquired in fully non-contact generation and reception of ultrasound. This method was proved as useful technique for detecting delamination in CFRP.

  • PDF

동작에 따른 타이트 스커트 최소 적정 트임량과 생리적인 반응 (Optimal Slit Length Limit of Tight Skirts in Movement and Physiological Response)

  • Kim, Hee-Eun;Lee, Jung-Sug
    • 한국의류학회지
    • /
    • 제27권12호
    • /
    • pp.1390-1396
    • /
    • 2003
  • 본 연구는 타이트 스커트의 트임의 개수가 왼쪽 옆선에 1개 있을 때와 왼쪽 옆선, 오른쪽 옆선에 각각 1개씩 모두 2개 있을 때 평지 보행, 계단 승강, 버스 승강 등과 같은 일상동작에 잘 적응할 수 있는 타이트 스커트의 적정 트임 길이를 설정하는 것을 목표로 하였다. 아울러 각 동작시의 트임 길이에 따른 생리적인 반응을 의복압, 산소 섭취량을 통해 알아보고자 하였다. 평균보폭은 4m 구간을 평상시대로 걸을 때의 발자국간 평균거리를 이용하였으며 국민표준체위조사보고서(1997)에 의한 평균체형을 가진 9명의 피험자를 정하였다. 스커트의 형태는 무릎길이인 타이트 스커트로 정하였다. 스커트의 트임은 왼쪽 옆선에 1개 있는 경우와 왼쪽 옆선, 오른쪽 옆선에 각각 1개씩 있는 경우의 2종류이다. 트임이 1개인 스커트는 2cm 간격으로, 트임이 2개인 스커트는 1cm 간격으로 트임 위치를 표시하여 길이를 조정하였다. 적정 트임 길이는 Likert 척도에 의한 만족도 평가로 측정하였으며 의복압은 air-bag system으로, 산소 섭취량은 Quark $B^2$ 으로 측정하였다. 본 연구의 결과는 다음과 같다. 1. 스커트의 최소 적정 트임 길이는 트임 1개일 때 평지 보행시 4cm, 계단 승강시 12cm ,버스 승강시 18cm이며, 트임 2개일 때 평지 보행시 2cm, 계단 승강시 8cm, 버스 승강시 15cm로 나타났다. 2. 의복압의 경우, 동일 트임 길이에서 트임 1개의 의복압이 트임 2개의 의복압보다 높았지만 트임 개수에 따른 전체 트임 길이로 보면 트임 1개의 의복압이 트임 2개의 의복압 보다 낮게 나타났다. 동작별로는 버스 승강의 의복압이 가장 높고 계단 승강, 평지 보행 순으로 낮아졌다. 3. 산소 섭취량의 경우, 동일 트임 길이에서 트임 1개와 트임 2개의 산소 섭취량은 거의 비슷하였다. 트임 개수에 따른 전체 트임 길이로 보면 트임 1개의 산소 섭취량이 트임 2개의 산소 섭취량보다 낮게 나타났다. 동작별로는 버스 승강의 산소 섭취량이 가장 높고 계단 승강, 평지 보행 순으로 낮아졌다.

특정크기 입자농축을 위한 대유량 슬릿형 2단 가상충돌기의 성능분석 (Analysis of High Volume Slit Type Two-Stage Virtual Impactor for Particle Size Classification)

  • 박성호;김상수;오명도
    • 대한기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.285-291
    • /
    • 1991
  • 본 연구에서는 800 1pm인 대유량을 처리하고 공기중 1.8~4.5$\mu\textrm{m}$ 입자를 효율 적으로 선별하여 농축시키는 슬릿형 2단 가상충돌기를 설계 제작하고 그 성능이 평가 되었다. 즉, 첫째단과 둘째단에서 4.5$\mu\textrm{m}$과 1.8$\mu\textrm{m}$이 각각 50%의 효율로 분리되도록 설계되었다. 즉, 첫째단과 둘째단에서 4.5$\mu\textrm{m}$과 1.8$\mu\textrm{m}$이 각각 50%의 효율로 분리되도 록 설계한다. 설계인자(design parameter)들을 결정하기 위하여 먼저 슬릿형 노즐의 1단 가상충돌기의 분리효율(separation efficiency)에 대한 실험을 통하여 50% 커트오 프 Stokes수를 구하고, 이를 기초로 하여 2단 가상 충돌기의 주요치수와 작동조건을 결정하였다.

콘형 가스버너의 난류유동장에 대한 슬릿과 스월베인의 역할 (The Role of Slits and Swirl Vanes on the Turbulent Flow Fields in Cone Type Gas Burner)

  • 김장권;정규조
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.341-346
    • /
    • 2001
  • The gun-type gas burner adopted in this study is generally composed of some slits and swirl vanes. Therefore, this paper is studied to investigate the effect of slits and swirl vanes on the turbulent flow fields in the horizontal plane of gas swirl burner with a cone type baffle plate measured by using X-probe from hot-wire anemometer system. This experiment is carried out at flow rate $450\;{\ell}/min$, which is equivalent to the combustion air flow rate necessary for heat release 15,000 kcal/hr in gas furnace, in the test section of subsonic wind tunnel. When the burner has only swirl vanes, the axial mean velocity component shows the characteristic that spreads more remarkably toward radial direction than axial one, but when it has only slits, that is developed spreading more toward axial direction than radial one. Therefore, because the biggest speed is spurted in slits and it derive main flow toward axial direction encircling rotational flow that comes out from swirl vane that is situated on the inside of slits, both slits and swirl vanes composing of cone type gas burner act role that decreases the speed near slits and increases the flow speed in the central part of a burner. Moreover, because rotational flow by swirl vanes and fast jet flow by slits increase turbulent intensities effectively coexisting, the turbulent kinetic energy is distributed with a bigger size fairly near slits than burner models which have only slit or swirl vanes within X/R<0.6410.

  • PDF