• Title/Summary/Keyword: Air quality standards

Search Result 254, Processing Time 0.035 seconds

A Study on TSP and Pb Concentration in Atmosphere in Seoul (서울 일부지역의 도로변 대기중 분진 및 납 농도에 대한 조사연구)

  • 김지선;박석환;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.1
    • /
    • pp.12-21
    • /
    • 1992
  • This study was performed to determine the concentrations of airborne TSP, Pb and street dust Pb in Kuro, Chongro, Namsan Tollgate and kwachun from August 15 to September 15, 1990.The results of this study are as follows. 1. Average airborne TSP concentrations in chongro and Kuro were 460$\mu$g/m$^{3}$ and 440$\mu$g/m$^}3}$, respectively, and exceeded the Korean air quality standards of 300$\mu$g/m$^{3}$. Average airborne TSP concentrations in Namsan Tollgate and Kwachun were 270$\mu$g/m$^{3}$ and 80$\mu$g/m$^{3}$, respectively, and didn't exceeded the Korean air quality standards of 300$\mu$g/m$^{3}$. The airborne TSP concentrations between Seoul area(Kuro, Chongro and Namsan Tollgate) and Kwachun area were significantly different (p < 0.01). 2. Average airborne Pb concentrations in Chongro, Kuro, Namsan Tollgate and Kwachun were 1.07, 0.55, 0.84 and 0.16$\mu$g/m$^{3}$, respectively. All the airborne Pb concentration at four area were below the Korean air quality standards of 1.5$\mu$g/m$^{3}$. The airborne Pb concentrations between Seoul area (Kuro, Chongro and Narnsan Tollgate) and Kwachun area were significantly different (p < 0.01). 3. Pb contents in street dusts in Kuro, Chongro, Namsan Tollgate and Kwachun were 9.30, 15.25, 18.17 and 3.16$\mu$g/g, respectively. The Pb contents in street dusts between Seoul area(Kuro, Chongro and Namsan Tollgate) and Kwachun area were significantly different (p < 0.01). 4. The airborne TSP and Pb concentrations were highly correlated(r=0.68), but the Pb concentrations in street dusts and atmosphere were poorly correlated(r=0.22).

  • PDF

Indoor Air Quality in Various Type of Public Facilities at Honam Province (호남지역의 다중이용시설별 실내공기질 실태 조사)

  • Seo, Byeong-Ryang;Jeong, Man-Ho;Jeon, Jun-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

Air Quality Impact Analysis for Point Sources Using Three-Dimensional Numerical Models (삼차원 수치모델을 이용한 점오염원의 대기환경영향 평가)

  • 김영성;오현선;김진영;강성대;조규탁;홍지형
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.4
    • /
    • pp.331-345
    • /
    • 2001
  • The increase of carbon monoxide in the ambient air due to the emissions from point sources without control was estimated using three -dimensional numerical models. The target area was Ulsan where one of the largest industrial complexes was located. As a typical example using numerical models for air quality impact analysis of criteria pollutants that will determine whether the air quality standards would be exceeded or not, the following approaches were suggested. They include: (1) investigation of pre-existing atmospheric conditions, (2) identification of major factors causing high concentrations, (3) selection of episode days. (4) preparation of three-dimensional meteorological data, (5) confirmation of agreement between measured and predicted concentrations in the emission conditions of episode days, and (6) estimation of the impact due to changes of the emission conditions. In the present work, daily meteorological conditions for the specific period were classified into four clusters of distinctive features, and the episode days were selected individually from each cluster. Emphasis was placed on the selection of episodes representing meteorological conditions conducive to high concentrations especially for point sources that were sensitive to the wind direction variations.

  • PDF

Indoor Air Quality Monitoring Systems in the IoT Environment (IoT 기반 실내 공기질 모니터링 시스템)

  • Oh, Chang-Se;Seo, Min-Seok;Lee, Jung-Hyuck;Kim, Sang-Hyun;Kim, Young-Don;Park, Hyun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.5
    • /
    • pp.886-891
    • /
    • 2015
  • Recently, The World Health Organization announced that harms human health because of air pollution that are emerging as threats to human health worldwide. according to the, Seoul, 2011 According to a July 2014 - Public Facilities indoor air quality measurements, were examined to be in violation of indoor air pollution standards in most multi-use facility. Indoor air pollution resulting from this is present in the paper, and cause disease, such as pulmonary disease, asthma, bronchitis and to In this connection, the measurement of indoor air quality by using the environment sensor, analyzing the measured data to generate an actuator signal required for ventilation and improve indoor air quality by implementing a monitoring system with real-time measurement, autonomously managing the air quality in our lives so that it can be.

Occupational Exposure to Chemicals for Workers and Levels of Airborne Chemicals in Hairdressing Salon (미용실 작업자의 화학물질에 대한 직업적인 노출과 실내공기오염 수준)

  • Yun, Jung Soon;Han, Don-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.375-384
    • /
    • 2006
  • Hairdressers may be exposed to many chemicals from hair dye, permanent, shampoo, hair spray and so on. The study was conducted to evaluate occupational exposure to 8 chemicals (isopropanol, ethanol, xylene, toluene, ethylbenzene, acetone, ammonia and formaldehyde) for workers and levels of these materials in airborne of a hairdressing salon. Since compared to ACGIH TLVs these 8 chemicals were very low, it is thought that there has no problem to occupational exposure to these chemicals. Even if hairdressing salon is not enforced on Korean Standards for Indoor Air Quality, level of TOVC was thought to be below the standards. At the aspect of indoor air quality formaldehyde needs to be controlled in the future. The results imply that emission of isopropanol, ethanol, acetone and ammonia are related with hairdressing job, but emission of xylene, toluene and ehtylbenzene is more related with traditional indoor air pollution than hairdressing job. Sources of formaldehyde is thought to be little related with hairdressing job. HVAC system was a little effective on general ventilation.

A Basic Study of Legal Standards for Building Health Performance (건축물의 건강성능에 관한 법적 기준의 기초연구)

  • Lee, Hyun-Min;Ryu, Sang-Yeon;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.19-26
    • /
    • 2009
  • In modern architecture, the air-tight construction aimed at saving the energy rather causes ventilation problems and the artificial materials for cost reduction worsen the residential quality. To deal with such negative effect, the study on evaluating the health performance becomes increasingly critical. Among the various factors such as design quality, selected material, construction method and mechanical system that shall be subject to evaluation to identify the health performance of the building, the study was aimed at investigating the legal standards associated with healthy building in various countries. Such evaluation items will provide inputs for an attempt to build legal criteria for a building health performance rating system in Korea.

Variation of Concentration of Air Pollutants with Air Mass Back-Trajectory Analysis in Gyeongju (기단 역궤적분석에 의한 경주시 대기오염물질의 농도 변화)

  • Kim, Kyung-Won;Bang, So-Yung;Jung, Jong-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.162-175
    • /
    • 2008
  • Gyeongju, which was the central city of the ancient civilization at Silla Kingdom, has various kinds of stone cultural properties. It is significantly important to preserve historical sources of Korea. However, recent air quality data measured in Gyeongju did not show good air quality level. In order to investigate variation of the concentration of the air pollutants with meteorological condition, an air quality monitoring and an aerosol sampling were conducted during the intensive monitoring period in Gyeongju. Impacts of the meteorological factors on the air pollutants were also analyzed based on the air mass pathway categories using HYSPLIT model and the local wind patterns using MM5 model. The prevailing air mass pathways were classified into four categories as following; category I affected by easterly marine aerosols, category II affected by northwesterly continental aerosols, category III affected by southwesterly continental aerosols, and category IV affected by northerly continental aerosols. The concentrations of the air quality standards were relatively lower during the fall intensive monitoring period. At that time, the easterly marine air mass pattern was dominated. The seasonal average mass concentration of $PM_{10,Opt}$, which optically measured at the monitoring site, was the highest value of $77.6{\pm}28.3\;{\mu}g\;m^{-3}$ during the spring intensive monitoring period but the lowest value of $20.1{\pm}5.3\;{\mu}g\;m^{-3}$ during the fall intensive monitoring period. The concentrations of $SO_2$ and CO were relatively higher when the air mass came from the northwestern continent or the northern continent. The concentrations of ${SO_4}^{2-}$ and ${NO_3}^-$ increased under the northwesterly continental condition. It was estimated that the acidic aerosols were dominated in the atmosphere of Gyeongju when the air mass came from the continental regions.

Measurement and Evaluation of Indoor Air Quality in Small-scale apartments in Daegu (대구지역의 신축 소규모 공동주택에 있어서 실내공기질 측정 및 평가)

  • Park, Hyun-Sik;Kim, Hyun-Tae;Hong, Won-Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.217-223
    • /
    • 2019
  • The purpose of this study was to measure the indoor air quality of small-scale apartments and then proposed a method to improve the indoor air quality of the small-scale apartments by comparing with the result of indoor air quality in the Clean-Healthy House. In case of formaldehyde, a highly volatile organic compound, the concentrations of indoor measured both in small-scale apartments and the Clean Healthy houses did not exceed- the guideline of Korea. The guideline of Korea for acetaldehyde was not available, so the guidelines of Japan and the World Health Organization were used to measure the concentration of acetaldehyde. The study results demonstrated that three out of seven small-scale apartments investigated exceeded the guideline of Japan; and the preliminary research on the Clean-Health Houses was low at about 30-60% of the guideline of Japan. The result of the VOCs measurement showed that toluene, ethylbenzene, and styrene in some small-scale apartments exceeded the guideline of Korea. However, the Clean-Healthy Houses in the previous studies did not exceed the guideline of Korea with regard to all the pollutants. Therefore, this study suggests the application of the construction standards of the Clean-Healthy house in order to improve the indoor air quality of small-scale apartments. In addition, the current study anticipates that improvement of the indoor air quality in the residential environments should be universally applied, not limited to the type and size of the residence.

A study on odor and ventilation in waste treatment facilities (폐기물 처리시설에서의 악취 및 환기에 관한 연구)

  • Seo, Byung-Suk;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.28-33
    • /
    • 2020
  • Recently, as the income level and quality of life have improved, the desire for a pleasant environment has increased, and a deodorization plan is required through thorough prevention and diffusion of odorous substances in waste treatment facilities recognized as hateful facilities, appropriate collection, and selection of the right prevention facilities. In this study, a waste disposal facility was modeled and computerized analysis for odor and ventilation analysis was conducted. Numerical analysis of the waste treatment facility was performed at the size of the actual plant. CATIA V5 R16 for numerical model generation and ANSYS FLUENT V.13 for general purpose flow analysis were used as analysis tools. The average air-age of the internal was 329 seconds, and the air-flow velocity was 0.384m/s. The odor diffusion analysis inside the underground pump room showed congestion-free air circulation through streamline distribution and air-age distribution. This satisfies the ASHRAE criteria. In addition, the results of diffusion analysis of odorous substances such as ammonia, hydrogen sulfide, methyl mercaptan and dimethyl sulfide were all expected to satisfy the regulatory standards. Particularly in the case of the waste loading area, the air-flow velocity was 0.297m/s, and the result of meeting the regulatory standards with 0.167ppm of ammonia, 0.00548ppm of hydrogen sulfide, 0.003ppm of methyl mercaptan, and 0.003ppm of dimethyl sulfide was found.

Study on Thermal Comfort and Indoor Air Quality in the Classroom with System Air-conditioner and Ventilation System for Cooling Loads (시스템에어컨과 환기시스템 설치 강의실에서 냉방시 열쾌적성 및 실내공기질 연구)

  • Noh Kwang-Chul;Jang Jae-Soo;Oh Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.1 s.244
    • /
    • pp.57-66
    • /
    • 2006
  • The experimental and the numerical study was performed on the comparison of thermal comfort(TC) and indoor air quality(IAQ) in the lecture room for cooling loads when the operating conditions are changed. PMV value and $CO_2$ concentration of the lecture room were measured and compared with the numerical results. The numerical results showed a good agreement with the experimental one and then the numerical tool was used to analyze thermal comfort and IAQ for a couple of operating conditions. As a result it was found that the increment of the discharge angle of system air-conditioner makes TC uniformity worse, but rarely affects IAQ. Also TC and IAQ were hardly affected by the variation of the discharge airflow. Finally it turned out that TC is merely affected by the increment of the ventilation airflow, but the average $CO_2$ concentration can be satisfied with Japanese IAQ standards of classrooms when the ventilation airflow is more than $800m^3/h$ in this study.