• Title/Summary/Keyword: Air quality standards

Search Result 256, Processing Time 0.034 seconds

Indoor Air Quality and Human Health Risk Assessment for Un-regulated Small-sized Sensitive Population Facilities (소규모 다중이용시설의 실내공기질 실태조사 및 건강위해성평가: 민감군 이용시설을 중심으로)

  • Shin, Hyejin;Park, Woosang;Kim, Bokyung;Ji, Kyunghee;Kim, Ki-Tae
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.397-407
    • /
    • 2018
  • Objectives: The purpose of this study is to investigate human health risk assessment of indoor air pollutants at small-sized public-use facilities (e.g., daycare centers, hospital and elderly care facilities) that the susceptible population is mainly used. Methods: To assess indoor air quality (IAQ), the concentrations of indoor air contaminants such as HCHO, benzene, toluene, ethylbenzene, xylene, styrene, PM-10, CO, $NO_2$ and $O_3$ in air samples were measured according to the Indoor Air Quality Standard Method. By conducting the questionnaire survey, the major factors influencing IAQ were identified. Human health risk assessment was carried out in the consideration of type of use (user and worker) at 75 daycare centers, 34 hospitals and 40 elderly care facilities. Results: As a result of measurement of indoor air contaminants, the average concentration of HCHO and TVOCs in hospitals was higher than daycare centers and elderly care facilities, about 8.8 and 23.5% of hospitals were exceeded by IAQ standard. In human health risk assessment, for the user of daycare centers and elderly care facilities, the mean carcinogenic risk of HCHO inhalation was higher than acceptable value. Except for HCHO, other values were determined under acceptable risk. Similarly, for the worker of hospitals, the mean carcinogenic risk of HCHO inhalation was higher than acceptable value and other values were evaluated under acceptable risk. In contrast, the risk levels of other contaminants measured in elderly care facilities were acceptable. In the determination of factors influencing IAQ, the construction year, building type, ventilation time, and the use of air cleaner were identified. Conclusions: This study provides the information for establishing the plans of public health management of IAQ at small-sized public-use facilities that have not yet been placed under the regulation. The findings suggest the consideration of human health risk assessment results for the IAQ standards.

An Evaluation of User's Facility and Suggestion for the Improvement on the Interior Design of Metropolitan Railroads Trains - Focus on the opening 14 metropolitan railroad lines in Seoul through checklist - (도시철도 차량 실내의 이용자 시설 평가와 개선방향 - 체크리스트를 통하여 수도권 노선에 운행 중인 14개 철도 차량을 대상으로 -)

  • Moon, Suh-Hyun;Kim, Gu-Seul;Shin, Kyung-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.5
    • /
    • pp.11-20
    • /
    • 2010
  • User-oriented Design is necessary in planning the interior design of Metropolitan Railroads trains, since this is a typical means of transportation in this modem society and all ages people with different body scale use this facility. However, there are little studies about facility panning and zoning of Metropolitan Railroads train considering users. Therefore, in this study, after completing the checklist based on the current legal standards of facility installation of South Korea and Japan, we examined user's facility and suggest several improvement of the opening 14 metropolitan railroad lines in Seoul. Then, we evaluated this facilities according to 41 standards; general facility(24 standards), safety facility(4 standards), guide facility(11 standards), other facility(4 standards). The result of this study may be summarized as follows. 1) General facility has to be designed to obtain lots of room for storage and this facility should be fixed up tightly with secure system. 2) Safety facility should be designed to minimize a difference of floor-level between threshold of train and ground. Also, using various color and material could help passengers to distinguish different space and facility. 3) Guide facility should be designed to guide passengers to the accurate direction with proper sign design in the pathway of Metropolitan railroad train. Also, more various color, which based on the research about physiological and psychological effect, should be used to guide people. 4) Other facility should equip more visual system using common good and informative contents. Through this study, we try to understand the current interior physical condition of Metropolitan Railroads trains. However, for future studies, it is expected to supplement evaluation standards considering aesthetic design, environmental improvement of indoor air quality and the satisfaction and demand of Metropolitan Railroads trains.

A Study on the Factors Affecting the Air Environment in Chungnam Province - Focusing on Cheonan, Dangjin, and Seosan (충남 대기환경 영향요인에 관한 연구 - 천안, 당진, 서산 등을 중심으로)

  • Hwang, Kyu-Won;Kim, Jinyoung;Kwon, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.118-127
    • /
    • 2021
  • Recently, the public's interest in the air environment has increased, and public health is threatened by fine particulate matter. Furthermore, the government continues efforts to improve air quality by expanding the monitoring of air pollutants and reinforcing environmental standards. Since air quality differs depending on the region in the Korean Peninsula, it is currently necessary to identify the cause and search for influencing factors. In this study, the atmospheric environment and regional differences in cities located in the Chungnam Province were observed. As a research method, regression analysis was performed for weather conditions, such as temperature, wind speed, precipitation, and season and targeted at air pollutants, such as SO2, NO2, CO, O3, PM10, and PM2.5, as well as heavy metals contained in particulate matter, such as Pb, Cd, Cr, Cu, Ni, As, Mn, Fe, Al, Ca, and Mg. In the case of PM10, the concentrations of Mn(0.4884) in Cheonan, CO(0.3329) in Dangjin, and Mg(0.5691) in Seosan were highest. In the case of PM2.5, Cheonan NO2(0.4759), Dangjin CO(0.4128), and Seosan NO2(0.3715) were significantly affected. In summary, the influencing factors vary according to the region in Chungnam province in terms of air quality, and there is a difference in the degree of contribution. Therefore, it is considered that the Korean government's management of air quality is required for each region.

환경보전 정책에 관한 제 방법의 상대적 효율성 연구 - 판매가능한 배출허용권제도를 중심으로 -

  • Lee, Seon;No, Gong-Gyun;Lee, Jae-Geun
    • Environmental and Resource Economics Review
    • /
    • v.1 no.1
    • /
    • pp.115-149
    • /
    • 1991
  • In evaluating current environmental protection policy, economists often note that current regulations are more costly than necessary to meet environmental quality standards. While the a priori case can be made that current regulatory approaches entail higher-than-necessary costs to attain environmental standards, there is relatively little empirical evidence to support this claim in Korea. The purpose of this analysis is to supply some of the missing evidence by presenting the results of one study that assesses some of the potential savings associated with implementing economic, rather than command-and-control regulatory approaches to abate one type of air pollution in one region, in Korea, Specifically, the analysis examine the costs of meeting a long-term standard for TSP under the alternative control strategies for stationary sources of TSP in Ulsan Industrial Complex region. The alternative strategies that are considered are current command-and-control and various marketable permit designs. The analysis shows that the most efficient policy of emissions control is economic approaches, supporting results of previous empirical studies conducted in other countries.

  • PDF

Design for Landfill Gas Appliation by Low Calorific Gas Turbine and Green House Optimization Technology (Low Calorific Gasturbine 매립지 적용 및 유리온실 운용기술 설계)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Lee, Jung-Bin;Rhim, Sang-Gyu
    • New & Renewable Energy
    • /
    • v.6 no.2
    • /
    • pp.27-32
    • /
    • 2010
  • Low Calorific Gas Turbine (LCGT) has been developed as a next generation power system using landfill gas (LFG) and biogas made from various organic wastes, food Waste, waste water and Livestock biogas. Low calorific fuel purification by pretreatment system and carbon dioxide fixation by green house system are very important design target for the optimum applications of LCGT. Main troubles of Low Calorific Gas Turbine system was derived from the impurities such as hydro sulfide, siloxane, water contained in biogas. Even if the quality of the bio fuel is not better than natural gas, LCGT may take low quality gas fuel and environmental friendly power system. The mechanical characterisitics of LCGT system is a high energy efficiency (>70%), wide range of output power (30 kW - 30 MW class) and very clean emission from power system (low NOx). A green house has been designed for four different carbon dioxide concentration from ambient air to 2000 ppm by utilizing the exhaust gas and hot water from LCGT system. LCGT is expected to contribute achieving the target of Renewable Portfolio Standards (RPS).

Fuel Properties of Woody Pellets in Domestic Markets of Korea

  • Oh, Jae-Heun;Hwang, Jin-Sung;Cha, Du-Song
    • Journal of Forest and Environmental Science
    • /
    • v.30 no.4
    • /
    • pp.362-369
    • /
    • 2014
  • This study investigated physical properties and combustion gas characteristics for 8 types of wood pellets (4 domestic and 4 imported products) distributed in the domestic market. Results showed that most pellet types were first-grade pellets in the wood pellet quality standards in Korea with the exception of 3 pellet types from K company (second-grade in mechanical durability), G company (off-grade in nitrogen content) and P company (second-grade in ash percentage). Mixed pellets which contained more lignin and sap content were higher in mechanical durability (%) than that of white pellets. From the combustion gas analysis results, NOx emitted from all pellets combustion was at acceptable levels for national emission standard of the Clean Air Conservation Act except for pellets from G company. In addition, CO levels from all types of wood pellets were acceptable except for pellets from D company and domestic pellets were higher CO levels than imported pellets. These results indicate the higher CO levels in domestic pellets due to the usage of forest thinning materials including logging debris which usually had the high content of bark.

Study on Reduction Unburned Carbon Contents in Low Quality Fly Ash from Vietnam (베트남 저품위 비산재의 미연탄소 함량 저감 연구)

  • Kim, Keeseok;Lee, Jaewon;Lee, Dongwon;Min, Kyongnam
    • Resources Recycling
    • /
    • v.29 no.2
    • /
    • pp.37-47
    • /
    • 2020
  • According to Vietnam government establishes additional thermal power plant, processing the coal ash from power plant is urgent issue. This study targeted reducing unburned carbon contents in low quality fly ash to below 6% that according to international standards. As a result, the unburned carbon contents of low quality fly ash was high and irregular as 5.3~23.6%, and it was possible to reduce unburned cabon contents to under 6%, in case of unburned carbon contents below 9.8% ashes using air classification, in case of unburned carbon contents below 23.6% ashes using combined process composed of air classification and electrostatic separation.

A Study on Assessment Standard for Environmental Impact Assessment (한국에서의 환경영향평가 평가기준에 대한 연구)

  • Lee, Mu-Choon
    • Journal of Environmental Impact Assessment
    • /
    • v.2 no.2
    • /
    • pp.111-116
    • /
    • 1993
  • The EIA system was developed during ten odd years of introduction. On the other hand, the contentional development representing systematical fidelity does not match to it. I surveyed the problems of EIA on the point of environmental items with no legal standards. EIA is being executed only once on the planning stage. If the present EIA system has two times of execution, the quality of EIA will be much better. First, on the stage of deciding location of the project, EIA should be done. And next, detailed EIA should be done on the stage of executing the project. To describe the problems of EIA, I surveyed the legislations on the point of the former stages, investigation of present status and anticipation. And I tried a theoretical approach to EIA. The knowledge of things, the subject's standpoint and his valuation are all put together in the EIA. The knowledge of relationship between air and water pollutants and their impact on human is accumulated much. On the other hand, the knowledge of the compounded item, fauna-flora(natural ecology) is partial and causes many difficulties. I pointed out the absurdities of assessment technique dealing the standards and introduced assessment technique being applied to items with no physico-chemical standards such as wild lives.

  • PDF

Standardization of Surface Replication Procedures for Life Assessment of High Temperature Facilities (고온설비 수명평가를 위한 표면복제 절차의 표준화)

  • Park, Jong-Seo;Lee, Hae-Mu;Baek, Un-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2381-2386
    • /
    • 2000
  • Surface replication is playing an important role in the assessment of creep damage and remaining life of high temperature components. As the replication procedures, however, have not been standardized in domestic industry, its standardization is proposed in this study. For this purpose, the 2.25Cr-IMo steel was heat treated(5 min at 1,300 0C and oil quenched) to produce a simulated HAZ microstructure, and crept in air at 575 0C and under 120 MPa to produce artificial cavities. Then, the effect of surface preparation procedures on the quality of replicas was investigated using this sample. As a result, it was demonstrated that the presence of cavities may be observed readily or missed depending on the surface preparation procedures followed. Therefore it is essential to repeat three polishing/etching cycles at least in order to reveal cavitation damage accurately, even though it may be tedious or time-consuming.