• Title/Summary/Keyword: Air quality monitoring system

Search Result 161, Processing Time 0.027 seconds

Optimization of Fugitive Dust Control System for Meteorological Conditions (기상조건별 비산먼지 관리체계 최적화 연구)

  • Kim Hyun-Goo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.573-583
    • /
    • 2005
  • Fugitive dust, which is emitted in the ambient air without first passing through a stack or duct designed to control flow, is frequently generated by means of wind erosion from storage yards at Pohang Steel Wokrs. The size distribution of fugitive dust is mostly in the range of coarse particulate which is deposited as soon as emitted and less harm to human health; however $20\%$ of fugitive dust contains PM 10 known as one of most harmful airborne pollutant. Consequently, effective control and reduction of fugitive dust is strongly requested by the local society, but it is not easy so far because the generation and dispersion of fugitive dust highly depends on meteorological conditions, and it being occurred for irregularity. This research presented a fugitive dust control system for each meteorological condition by providing statistical prediction data obtained from a statistical analysis on the probability of generating the threshold velocity at which the fugitive dust begins to occur, and the frequency occurring by season and by time of the wind direction that can generate atmospheric pollution when the dispersed dust spreads to adjacent residential areas. The research also built a fugitive dust detection system which monitors the weather conditions surrounding storage yards and the changes in air quality on a real-time basis and issues a warning message by identifying a situation where the fugitive dust disperses outside the site boundary line so that appropriate measures can be taken on a timely basis. Furthermore, in respect to the spraying of water to prevent the generation of fugitive dust from the storage piles at the storage yard, an advanced statistical meteorological analysis on the weather conditions in Pohang area and a case study of fugitive dust dispersion toward outside of working field during $2002\∼2003$ were carried out in order to decide an optimal water-spraying time and the number of spraying that can prevent the origin of fugitive dust emission. The results of this research are expected to create extremely significant effects in improving surrounding environment through actual reduction of the fugitive dust produced from the storage yard of Pohang Steel Works by providing a high-tech warning system capable of constantly monitoring the leakage of fugitive dust and water-spray guidance that can maximize the water-spraying effects.

Effect of Plant Educational Programs Elementary School using Vertical Garden (수직정원을 활용한 초등학교 식물교육프로그램 운영 효과 분석)

  • Jeong, Na-Ra;You, Soo-Jin;Kim, Kwang-Jin;Han, Seung-Won
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.5
    • /
    • pp.73-86
    • /
    • 2020
  • In the modern era, the elementary schools in the Republic of Korea are advanced with the competitive world. Thus advancement in technology, and other factors in the elementary schools are releases some kind of particulate matter (PM), which causes deleterious effects on school students health, academic program, growth and development. The school students are susceptible to PM particularly, PM10 and PM2.5. Based on this hazardous effect of PM on school students we conducted the research on the elementary schools class rooms by introducing vertical gardening system to get the schools "ever green". The main aim of this study is to investigate the environmental factors in the educational effect program in the class rooms and indoor air quality changes. For the educational effect, the 4th operation program was applied to 2 schools for 2 hours once a month from September to December 2019. Each school conducted a survey on satisfaction, plant friendliness, and environmental sensibilities, targeting classes that participated in the green school program and those who did not. The environmental effects were monitored by installing indoor air quality facility in the program participating classes and the non-participating classes. From November 2019 to December 2019, three factors were measured: PM10, PM2.5, and humidity. The results were analyzed by T-test using the SPSS 24.0 software program. As a result of the analysis, student's overall satisfaction with the program and their intention to re-engage were high in terms of educational effect. It was also found to be effective in emotional, educational, social, and physical aspects. In particular, it was found that there was a statistically significant effect on improving plant friendliness in terms of plant friendliness and environmental sensitivity. In terms of environmental effects, it was found that there was a significant difference between the program-applied and non-programmed classes in PM10, PM2.5, and humidity. Through this study, it was confirmed that the plant education program using vertical gardens is effective in both the educational effect and the improvement of indoor air quality in the classroom. In conclusion, vertical gardening system in the elementary schools should implement for the beneficial of young generation development and back bone to the nation.

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

Development of a Greenhouse Environment Monitoring System using Low-cost Microcontroller and Open-source Software (저비용 개방형 Microcontroller를 사용한 온실 환경 측정 시스템 개발)

  • Cha, Mi-Kyung;Jeon, Youn A;Son, Jung Eek;Chung, Sun-Ok;Cho, Young-Yeol
    • Horticultural Science & Technology
    • /
    • v.34 no.6
    • /
    • pp.860-870
    • /
    • 2016
  • Continuous monitoring of environmental parameters provides farmers with useful information, which can improve the quality and productivity of crops grown in greenhouses. The objective of this study was to develop a greenhouse environment measurement system using a low-cost microcontroller with open-source software. Greenhouse environment parameters measured were air temperature, relative humidity, and carbon dioxide ($CO_2$) concentration. The ranges of the temperature, relative humidity, and $CO_2$ concentration were -40 to $120^{\circ}C$, 0 to 100%, and 0 to 10,000 ppm, respectively. A $128{\times}64$ graphic LCD display was used for real-time monitoring of the greenhouse environments. An Arduino Uno R3 consisted of a USB interface for communicating with a computer, 6 analog inputs, and 14 digital input/output pins. A temperature/relative humidity sensor was connected to digital pins 2 and 3. A $CO_2$ sensor was connected to digital pins 12 and 13. The LCD was connected to digital pin 1 (TX). The sketches were programmed with the Arduino Software (IDE). A measurement system including the Arduino board, sensors, and accessories was developed (totaling $244). Data for the environmental parameters in a venlo-type greenhouse were obtained using this system without any problems. We expect that the low-cost microcontroller using open-source software can be used for monitoring the environments of plastic greenhouses in Korea.

A Case Study on the Comparison and Assessment between Environmental Impact Assessment and Post-Environmental Investigation Using Principal Component Analysis (주성분분석을 이용한 환경영향평가와 사후환경조사의 비교 및 평가에 관한 사례연구)

  • Cho Il-Hyoung;Kim Yong-Sup;Zoh Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.2 s.83
    • /
    • pp.134-146
    • /
    • 2005
  • Environmental monitoring system has been adopted and supplemented as inspection measures for the quantitative and qualitative changes of environmental impact assessment (EIA). This study compares the results of environmental impact assessment with the results of post-environmental investigation using a correction and principal component analysis (PCA) in the housing development project. Correlation analysis showed that most of air quality variables including TSP, $PM_{10},\;NO_2$, CO were linearly correlated with each other in the environmental impact assessment and the post-environmental investigation. In the water quality, pH and BOD were well correlated with the DO and SS, respectively. As a result of correlation analysis in the noise and vibration, noise in day and night and vibration in day and night were related to each other between EIA and the post-environmental investigation. From the results of analysis of soil, Cu with Cd, Cu with Pb, and Cd with Pb were related to each other in EIA. Principal component analysis (PCA) showed a powerful pattern recognition that had attempted to explain the variance of a large dataset of inter-correlated variable with a smaller set of independent variables (principal components). Principal component (PC1) and principal component (PC2) were obtained with eigenvalues> 1 summing almost $90\%$ of the total variance in the all of the items(air, water, noise, vibration and soil) in EIA and post-environmental investigation.

Remote Sensing of Atmospheric Trace Species using Multi Axis Differential Optical Absorption Spectroscopy (Multi Axis DOAS를 이용한 대기미량 물질 원격 측정)

  • Lee Chul-Kyu;Kim Young-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.2
    • /
    • pp.141-151
    • /
    • 2006
  • UV-visible absorption measurement techniques using several horizone viewing directions in addition to the traditional zenith-sky pointing have been recently developed in ground-based remote sensing of atmospheric constituents. The spatial distribution of various trace gases close to the instrument can be derived by combing several viewing directions. Multi-axis differential optical absorption spectroscopy (MAX-DOAS) technique, one of the remote sensing techniques for air quality measurements, uses the scattered sunlight as a light source and measures it at various elevation angles (corresponding to the viewing directions) by sequential scanning with a stepper motor. A MAX-DOAS system developed by GIST/ADEMRC has been applied to measuring trace gases in urban air and plumes of the volcano and fossil fuel power plant in January, May, and October 2004, respectively. MAX-DOAS spectra were analyzed to identify and quantify $SO_2,\;NO_2,\;BrO,\;and\;O_4$ (based on Slant Column Densities, SCD) in the urban air, volcanic plume, and fossil fuel power plant utilizing theirs specific structured absorption features in the UV-visible region. Vertical scan through the multiple elevation angles was performed at different directions perpendicular to the plume dispersion to retrieve cross-sectional distribution of $SO_2\;or\;NO_2$ in the plumes of the volcano and fossil fuel power plant. Based on the estimated cross sections of the plumes the mixing ratios were estimated to 580 $SO_2$ ppbv in the volcanic Plume, and 337 $NO_2\;and\;227\;SO_2$ ppbv in the plume of the fossil fuel power plant, respectively.

Development of Environmental Safety Real-Time Monitoring System by Living Area (생활권역별 환경안전 실시간 모니터링 시스템의 개발)

  • Lee, Joo-Hyun;Kim, Joo-Ho;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1088-1091
    • /
    • 2019
  • In this paper, a real-time monitoring system for environmental safety by living area is proposed. The proposed system is designed to measure radiation, fine dust and basic living information (temperature) using fixed and mobile measuring equipment, and constitutes a web database that stores data received from the equipment. It also develops web programs for displaying received data on PCs and mobile phones. The results of testing the performance of the system by an authorized testing agency showed that the radiation measurement range was measured in the range of $10{\mu}Sv/h$ to 10mSv/h, which is comparable to the world's highest level, and that the accuracy was measured between ${\pm}6.7$ and ${\pm}8.7$ percent of the measurement uncertainty was measured and normal operation at or below the international standard of ${\pm}15$ percent. In addition, the temperature test was conducted on a section of $-20^{\circ}C$ to $50^{\circ}C$ and normal operation was confirmed in response to the temperature change. Stability of radiated electromagnetic waves was ensured by a suitable judgment. The product's testing in general and high and low temperature environments for about four months after the prototype was made confirmed to be more than five years of durability. The measurement range and accuracy of fine dust sensors are compared with those of companies that measure the air environment, and the performance level is similar through the air quality measurement register.

Development of an IAQ Index for Indoor Garden Based IoT Applications for Residents' Health Management (실내거주자 건강 관리를 위한 IoT기반 실내정원용 IAQ지수 개발)

  • Lee, Jeong-Hun;An, Sun-Min;Kwak, Min-Jung;Kim, Kwang Jin;Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.421-432
    • /
    • 2018
  • Objectives: In this study, we started to develop an indoor garden integrated IoT solution based on IAQ (indoor air quality) and interconnection with an environmental database for smart management of indoor gardens. The purpose of this study was to develop and apply an integrated solution for customized air purification from an indoor garden through big data analysis using IoT technology. Methods: An IoT-based IAQ monitoring system was established in three households within a new apartment building. Based on real-time and long-term data collected, $PM_{2.5}$, $CO_2$, temperature, and humidity changes were compared to those of indoor garden applications and the analyzed results were indexed. Results As a result of the installation, all three households had no results exceeding the standard for indoor air pollution on average $PM_{2.5}$ and $CO_2$ indices. In the case of indoor garden installation, the IAQ index increased to the "Good" section after the installation, and readings in the "Bad" section shown before the installation disappeared. The comfort index also did not dip into the "Uncomfortable" section, where it had been preinstallation, and significantly lowered the average score from "Uncomfortable for sensitive groups" to "Good". Overall, the IAQ composite index for the generation of installations decreased the "Good" interval, but "Bad" did not appear. Conclusions In this study on developing an integrated solution for IAQ based on IoT indoor gardens, big data was analyzed to determine IAQ and comfort indexes and an IAQ composite index. Through this process, it became understood that it is necessary to monitor IAQ based on IoT.

A Study on the Distribution Characteristics and Countermeasures of Concentrations of Ambient PM10 and PM2.5 in Yangju, South Korea

  • Dohun Lim;Yoonjin Lee
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.701-716
    • /
    • 2022
  • This study investigated the distribution behaviors of PM2.5 and PM10 at two air quality monitoring sites, Go-eup (GO) and Backseokeup (BS), located in Yangju City, South Korea. The amounts of emissions sources of pollutants were analyzed based on the Clean Air Policy Support System (CAPSS), and the contribution rates of neighboring cities were enumerated in Yangju. Yangju has a geological basin structure, and it is a city with mixed urban and rural characteristics. The emission concentration of particulate matter was affected by geological and seasonal factors for all sites observed in this study. Therefore, these factors should be considered when establishing policies related to particulate matter. Because the official GO and BS station sites in Yangju are both situated in the southern part of the city, the representativeness of both stations was checked using correlation analysis for the measurement of PM2.5 and PM10 by considering two more sites-those of Bongyang-dong (BY) and the Gumjun (GJ) industrial complex. The data included discharge amounts for business types 4 and 5, which were not sufficiently considered in the CAPSS estimates. Because the 4 and 5 types of businesses represent over 92.6% of businesses in this city, they are workplaces in Yangju that have a significant effect on the total air pollutant emission. These types of businesses should be re-inspected as the main discharge sources in industry, and basic data accumulation should be carried out. Moreover, to manage the emission of particulate matter, attainable countermeasures for the main sources of these emissions should be prepared in a prioritized fashion; such countermeasures include prohibition of backyard burning, supervision of charcoal kilns, and management of livestock excretions and fugitive dust in construction sites and on roads. The contribution rates by neighboring cities was enumerated between 6.3% and 10.9% for PM2.5. Cooperation policies are thought to be required with neighboring cites to reduce particulate matter.

New Environmental Impact Assessment Technology (신환경영향평가기술(新環境影響評價技術)의 개발방향(開發方向))

  • Han, Sang-Wook;Lee, Jong-Ho;Nam, Young-Sook
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.4
    • /
    • pp.277-290
    • /
    • 2000
  • The purpose of this study is to identify the problems of environmental impact assessment(EIA) and to suggest new EIA technology. The problems of EIA in Korea can be summarized as follows. First, the EIA does not reflect the impact of policy, plan and program on environment. Second, the project EIA does not consider the cumulative impacts such as additive impacts, synergistic impacts, threshold/saturation impacts, induced and indirect impacts, time-crowded impacts, and space-crowded impacts. Third, the EIA techniques in Korea are not standardized. Finally, the present EIA suggests only alternatives to reduce adverse impacts. To solve above-mentioned problems, the development of new EIA technology is essential. First, the new EIA technology should be developed toward pollution prevention technology and comprehensive and integrated environmental management technology. Second, new fields of EIA for pollution prevention contain strategic environmental assessment, cumulative impacts assessment, socio-economic impact assessment, cyber EIA and EIA technology necessary after the reunification of Korean Peninsula. Third, EIA technology for integrated environmental management contains the development of integated environment assessment system and the development of packaged EIA technology. The EIA technology for integrated environmental assessment system contains (1) development of integrated impact assessment technology combining air/water quality model, GIS and remote sensing, (2) integrated impact assessment of EIA, traffic impact assessment, population impact assessment and disaster impact assessment. (3) development of integrated technology combining risk assessment and EIA (4) development of integrated technology of life cycle assessment and EIA, (5) development of integrated technology of spatial planning and EIA, (6) EIA technology for biodiversity towards sustainable development, (7) mathematical model and GIS based location decision techniques, and (8) environmental monitoring and audit. Furthermore, there are some fields which need packaged EIA technology. In case of dam development, urban or industrial complex development, tourist development, landfill or combustion facilities construction, electric power plant development, development of port, road/rail/air port, is necessary the standardized and packaged EIA technology which considers the common characteristics of the same kind of development project.

  • PDF