• 제목/요약/키워드: Air quality monitoring system

검색결과 161건 처리시간 0.03초

지표투과레이더와 적외선카메라를 이용한 아스팔트 포장 시공 관리 방법 (Construction Management Method for Asphalt Paving Using Ground Penetrating Radar and an Infrared Camera)

  • 백종은;박희문;유평준;임재규
    • 한국도로학회논문집
    • /
    • 제17권6호
    • /
    • pp.1-9
    • /
    • 2015
  • PURPOSES : The objective of this study is to propose a quality control and quality assurance method for use during asphalt pavement construction using non-destructive methods, such as ground penetrating radar (GPR) and an infrared (IR) camera. METHODS : A 1.0 GHz air-coupled GPR system was used to measure the thickness and in situ density of asphalt concrete overlay during the placement and compaction of the asphalt layer in two test construction sections. The in situ density of the asphalt layer was estimated based on the dielectric constant of the asphalt concrete, which was measured as the ratio of the amplitude of the surface reflection of the asphalt mat to that of a metal plate. In addition, an IR camera was used to monitor the surface temperature of the asphalt mat to ensure its uniformity, for both conventional asphalt concrete and fiber-reinforced asphalt (FRA) concrete. RESULTS : From the GPR test, the measured in situ air void of the asphalt concrete overlay gradually decreased from 12.6% at placement to 8.1% after five roller passes for conventional asphalt concrete, and from 10.7% to 5.9% for the FRA concrete. The thickness of the asphalt concrete overlay was reduced from 7.0 cm to 6.0 cm for the conventional material, and from 9.2 cm to 6.4 cm for the FRA concrete. From the IR camera measurements, the temperature differences in the asphalt mat ranged from $10^{\circ}C$ to $30^{\circ}C$ in the two test sections. CONCLUSIONS : During asphalt concrete construction, GPR and IR tests can be applicable for monitoring the changes in in situ density, thickness, and temperature differences of the overlay, which are the most important factors for quality control. For easier and more reliable quality control of asphalt overlay construction, it is better to use the thickness measurement from the GPR.

Paint booth volatile organic compounds emissions in an urban auto-repair center

  • Cho, Minkyu;Kim, Ki-Hyun;Szulejko, Jan E.;Dutta, Tanushree;Jo, Sang-Hee;Lee, Min-Hee;Lee, Sang-hun
    • 분석과학
    • /
    • 제30권6호
    • /
    • pp.329-337
    • /
    • 2017
  • A major concern regarding most auto-repair shops in residential areas is the emission of odorous volatile organic compounds (VOCs) into the local atmosphere, especially during painting operations. VOCs contribute to poor local air quality and are responsible for the perceived odor and discomfort experienced by local residents. Sixteen major VOCs (6 aromatic hydrocarbons and 10 aliphatic carbonyl compounds) were selected as potential target compounds. The site was an auto-repair shop located in a central region of Seoul, South Korea, where the air quality of the site has been a subject of residents' complaints. The sampling points were as follows: 1) in the painting booth with new (NB) or old (OB) removal system, (2) in the exhaust duct after new (ND) or old (OD) odor removal filter, and (3) 2 m below the discharge vent (4 m above the ground) (outdoor air, OA). Each sample was coded: (1) before painting (BP), (2) during painting (DP), and (3) after painting (AP). The toluene level in the duct with the new removal filter during painting (ND-DP) was 1.5 ppm (v/v), while it was 3.8 ppm (v/v) in the right duct with an old removal filter during painting (OD-DP). Accordingly, the effect of filter replacement was reflected by differences in VOC levels. Therefore, accurate monitoring of odorous VOCs is an important step to reduce odor nuisance from local sources.

센서 어레이를 이용한 휘발성유기화합물 측정기기 개발 (The Development of the VOCs Measurement System using Sensor Array)

  • 홍철호;김동진;이장훈;권혁구
    • Environmental Analysis Health and Toxicology
    • /
    • 제19권1호
    • /
    • pp.41-47
    • /
    • 2004
  • Air quality monitoring is a primary activity for industrial and social environment. The government push for pollutants that must be monitored. Especially, the VOCs (Volatile Organic Compounds), which are very harmful for human and environment, should be controlled under the government policy. We have been developed a VOCs measurement system which recognize various kinds and quantities of VOCs, such as benzene, toluene, and xylene (BTX). Especially, we designed sensor array with various kinds of gas sensor and ANN (Artificial Neural Network) algorithm. The measured values for BTX have errors of-4ppm.

소방서 실내공간의 화학적 유해인자 2차노출과 실내공기질 특성 (Characterization of Secondary Exposure to Chemicals and Indoor Air Quality in Fire Station)

  • 김수진;함승헌;전정석;김원
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.140-151
    • /
    • 2019
  • 본 연구에서는 소방관들이 화재현장에서 복귀 후 소방청사 내에서 2차적으로 노출된 화학적 유해물질의 실내공기질을 평가하였다. 서울시에 소재한 4개 소방서를 선정하였고, 그 중 2개 소방서는 실제 화재현장에서 소방활동 종료 귀소 후에, 다른 2개 소방서는 대조군으로 설정하여 출동과 상관없이 평소 수준의 실내공기질을 측정하였다. 소방안전지도 전산시스템을 이용하여 서울시에서 발생하는 모든 화재사고에 대하여 24시간 모니터링을 실시하였고 중급규모 이상의 사고에서 실험군이 출동하게 되는 경우 귀소 후 바로 실내공기질을 측정하였다. 11개 유해물질 항목(미세먼지, 포름알데히드, 휘발성유기화합물, PAH, VCM, 산류, 석면, CO, CO2, NO2, O3)을 공정시험법에 따라 측정하였다. 유해물질 11종 중 3종이 국내·외 기준을 초과하였고 1종은 국외기준에 육박하는 것으로 확인되었다. 특히 총휘발성 유기화합물, 이산화탄소, 황산은 각 2.5배, 2.2배, 1.1배가 환경부 및 고용노동부 기준보다 높았다. 또한, 포름알데히드와 황산의 경우, 실험군보다 대조군에서 더 높게 측정되었다. 본 연구결과는 서울특별시 소방청사 내 실내공기질 개선 정책에 활용될 수 있을 것이다.

부산시의 대기오염과 측정망(감시망)에 관한 고찰 (A Study on Air Quality and Monitoring System in Busan)

  • 박재림
    • 한국환경보건학회지
    • /
    • 제2권1호
    • /
    • pp.37-48
    • /
    • 1975
  • Air pollutants were measured to get useful data in preventing and controlling the pollution at industrial and semi-industrial, commercial, cross-road and residential areas by season in Busan from September 1973 to June 1974. Teated were dustfalls(ton/$km^2$/month)by Deposit Gauge method, sulfuric anhydride(mg $SO_3/day/100cm^2 PbO_2$) by Lead Peroxide candle method. The relations between pollution and metherologlcal factors and source of pollution were discussed, The findings are as follows: 1. The mean value of dustfalls was 24.8 tons rangi~ng from 12.5 tons to 44.5 tons. The highest amount of dustfalls of 29.0 tons was measured in crossroad areas while the 1oeest of 22.7 tons in commercial areas, and Winter the highest of 27.7 tons while in Spring the lowest of 21.2 tons. 2. The mean value of water soluble substances was 31.7 per cent, and seasonal variation of pH was shown as 4.20 in Autumn, 3.85 in Summer and 2.76 in Winter. 3. The mean value of sulfuric anhydride was 1.54mg ranging from 0.197mg to 4.162 mg. The highest concentration of sulfuric anhydride of 2.03mg was detected in cross-road areas while thelowest of 1.23mg in residential areas, and Summer the highest of 2.18mg while in Spring the lowest of 1.09mg(0. 92mg in Nov. 1973) 4. Dustfalls are more with the decreased of relative humidity and precipitation while concentrat:on of sulfuric anhydrides are more with the increased of relative humidity. 5. There is a probability of occuring chronic symptoms(respiratory and others) as the dustfalls with 24.8 tons and sulfuric anhydride with 1.54mg in Busan. According to this, it is the time to discuss monitoring system and systematic preventing methods.

  • PDF

스마트공장의 IoT 센서 모니터링을 통한 에너지절감 및 안전성 향상 연구 (A Study on Energy Saving and Safety Improvement through IoT Sensor Monitoring in Smart Factory)

  • 최우형;강인철;김창수
    • 한국재난정보학회 논문집
    • /
    • 제20권1호
    • /
    • pp.117-127
    • /
    • 2024
  • 연구목적: 중소기업 제조공장에서 에너지 관리, 온도, 습도, 분진 및 가스, 공기 질, 기계작동 상태 등을 통합적으로 모니터링하여 에너지 절감 및 제조 공장 인프라의 안전성 향상을 위한 기반 연구를 수행하는 것이 목적이다. 연구방법: 이를 위해 디지털 전력량계 및 IoT 센서를 통해 에너지 관련 데이터 및 환경적인 정보들을 실시간으로 수집하였으며, 수집된 정보를 기반으로 모니터링 및 분석을 통해 에너지 절감을 위한 상황 전파 및 대응을 위한 연구를 진행하였다. 연구결과: ESG 경영 활동의 핵심 지표에 속하는 에너지관리, 비용 절감과 안전성 향상을 고려한 적용 방안을 제시하였다. 결론: 본 연구는 기업에서 실제적인 사례 연구로 스마트공장에서 다양한 센서 장치와 관련된 장치들을 활용하였으며, 이를 통해 수집된 정보를 기반으로 에너지 절감 및 안전성 향상에 대한 기반의 체계를 제시하였다.

종합관측부이 개발 및 실시간 관측기술 (Development of Ocean Data Buoy and Real-Time Monitoring Technology)

  • 심재설;이동영;박우선;박광순
    • 한국해안해양공학회지
    • /
    • 제11권1호
    • /
    • pp.56-67
    • /
    • 1999
  • 장기간의 해양 모니터링을 위해서는 종합관측부이를 국산화하여 활용하는 것이 요구된다. 이런 요구에 부응하여 한국과 비슷한 여건의 대만 성공대학과 공동연구를 통해 종합관측부이 제작기술을 도입하여 이를 한국에서 효율적으로 해양 환경 모니터링에 활용할 수 있게 발전·개선시켰다. 부이의 크기는 육상 운반과 해상 설치에 편리하도록 직경 2.5m로, NOAA의 3.0m 부이보다 작다. 부이의 동적특성을 수치모델로 해석하였는데, 주기가 4초 이상의 파랑을 관측하는 데는 문제가 없는 것으로 나타났다. 부이의 관측 및 제어 시스템을 개선하여 더 많은 관측센서를 부착할 수 있고, 전원 소모량을 줄이고 또 자료의 분석 및 관리 기능을 높혔다. 이 논문에서는 개선된 종합관측부이의 각 구성부분을 자세히 설명하였다. 종합관측부이는 풍향, 풍속,기온, 습도, 기압 및 파랑 등 기존의 해양 기상 요소에다 수온, 염분, DO, pH 및 탁도 등 해양환경 요소를 첨가하였다. 원해에 설치된 부이로부터 실시간 자료 전송을 위해 Inmarsat 위성통신 시스템을 이용하였다. 개선 제작된 부이는 포항 앞바다에서 1개월 간의 시범 운영을 통하여 계류, 자료 송신에 대한 성능 실험과 파랑자료를 검증하기 위하여 네덜란드의 Datawell사의 Wave-rider부이와 동시 관측 실험을 수행하였는데, 좋은 결과를 얻었다.

  • PDF

회전익항공기 상태감시시스템 임계값 최적화를 통한 비행안전성 확보기술 (Flight Safety Assurance Technology for Rotary Aircraft through Optimization of HUMS Vibration Thresholds)

  • 전병규;정상규;김영목;장인기
    • 한국항행학회논문지
    • /
    • 제20권5호
    • /
    • pp.446-452
    • /
    • 2016
  • 항공기는 비행이라는 특수성에 의해 안전성이 매우 중요하게 고려되어야 하며, 생산단계 뿐 아니라 운용 유지단계에서도 적절한 검사와 정비를 통해 비행안전성을 유지해야 한다. 최근에는 구성품의 건전성 확인과 정비 필요성 판단을 인적요소에 의존하지 않고 공학적 접근법에 의한 최신 기술이 사용되고 있으며, 국내에서 생산하는 회전익기에도 주요 구성품의 진동측정/감시 시스템인 health & usage monitoring system이 적용되어 운용 중에 있다. 그러나 진동 임계값이 부적절하여 생산 및 운용 간 지속적인 임계값 초과현상이 발생하였으며, 이는 실제 정비가 필요한 경우가 아닌 오경보로 판명되었다. 본 논문에서는 HUMS의 운용개념을 기술하고, 특히 제한된 여건에서 효율적으로 정비 필요성을 판단하기 위한 HUMS 임계값 최적화와 재설정된 임계값의 초과현상 발생시 조치해야하는 검사 및 정비행위를 정립하여 운용유지의 효율성과 궁극적으로 항공기 신뢰성을 향상 시킬 수 있는 연구를 수행하였다.

센서 네트워크를 이용한 실내 공기질 관리 및 제어에 관한 연구 (A Study of Environment Monitoring System based on Sensor Network)

  • 김기태;김동일
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.389-392
    • /
    • 2010
  • 특수한 작업장이외의 주택실내나 일반 사무실 등에서의 공기오염 문제는 인간이 주거시설에 거주한 이례로 계속되어온 문제로서 그 대책이 시급하다. 쉽게 외부의 신선한 공기와 충분한 양의 환기로서 해결이 가능하나 사람이 계속해서 관리해 주기에는 불편한 상황이다. 네트워크상에서 센서 네트워크를 이용한다면 쉽게 관리 및 제어가 가능하다. 유비쿼터스 센서 네트워크는 부착된 태그와 센서로부터 사물 및 환경 정보를 감지, 저장, 가공, 전달하여 인간 생활에 폭넓게 활용되며, 환경오염에 대해서도 사람이 직접 측정 및 모니터링 하기 힘든 지역에 설치되어 활용되고 있다. 다른 네트워크에 비해 초소형, 저전력, 저비용으로 쉽게 구성 가능하기 때문에 꾸준히 연구되어지고 있으며 환경과 IT의 전략적 융합을 통한 그린 IT의 네트워크 접목 또한 중요한 연구분야로 조명되고 있다. 본 논문에서는 네트워크 기반하에 실내 공기질 관리를 구성하고 관리 및 제어하여 활용 방안에 대하여 제시한다.

  • PDF

클린로드 시스템 가동이 도로변 $PM_{10}$ 농도에 미치는 영향 분석- 대구지역의 사례연구 - (Estimation of the Effect of Clean Road System on the $PM_{10}$ Concentration at a Heavy Traffic Roadside - A Case study for Daegu City -)

  • 조병윤;백성옥
    • 한국입자에어로졸학회지
    • /
    • 제8권3호
    • /
    • pp.111-120
    • /
    • 2012
  • In Daegu, a road cleaning system was constructed in the central part of the city and has been operated from April, 2011. We evaluated the effect of the system on the concentration of $PM_{10}$ at a roadside monitoring site. The ambient $PM_{10}$ concentration data were logged every 1 min for a period of 20 weeks from May to October, 2011, by means of light scattering method, and then every 5 min data were used in the statistical analysis. The measured data were verified by comparing them with beta-ray data obtained at the same site. Correlation coefficient between the two groups was highly significant (r=0.79), though the absolute levels of light scattering data appeared to be approximately 2.8 times higher than the beta-ray data. Diurnal, daily, weekly, and monthly variations of $PM_{10}$ data did not show any evidence of decreasing effect owing to the clean road system. A comparison of roadside $PM_{10}$ data with non-roadside data also revealed very similar pattern, implying the variation of the $PM_{10}$ concentrations is mainly affected by the traffic conditions near the monitoring site. However, if the operating conditions of the clean road system can be improved, i.e. increasing the frequency and duration of water cleaning, the road cleaning effect may improve the air quality indirectly by means of removing the resuspended particles from the road.