• 제목/요약/키워드: Air quality measurement

검색결과 449건 처리시간 0.03초

위해성을 고려한 대기오염물질의 관리 방향 (Direction for the management of air pollutants based on health risk in Korea)

  • 김영주;김용표
    • 한국입자에어로졸학회지
    • /
    • 제13권2호
    • /
    • pp.43-52
    • /
    • 2017
  • Policy direction for the management of air quality in Korea has been on the reduction of the average concentrations of the criteria air pollutants such as sulfur dioxide and fine particles. However, recently, risk based management of air pollutants becomes an important issue. In this study, to develop an effective air quality management policy direction in Korea, (1) the fourth Multiple Air Toxics Exposure Study (MATES IV) carried out in the South Coast Air Quality Management District (SQAQMD) in the USA is reviewed and (2) the results are compared with in these in Seoul and (3) policy directions are suggested. It was found that (1) systematic integrated study comprising of measurement, modeling, emission inventory estimation, and risk assessment was essential to estimate the health risk of air pollutants reliably, (2) cancer risk of diesel particle was dominant over other air pollutants, and (3) health risk based emissions were different from amount based emissions. It was suggested that (1) reducing the exposure from hot spots might important to reduce health risk from air pollutants and (2) an integrated air quality management administration system is important for the efficient management of air pollution.

식물을 이용한 실내공기조절시 이산화탄소의 영향에 관한 연구 (A Study on the Effect of CO2 in Condition of Indoor Air Quality Control Using Plants)

  • 이규인;권민재
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this research is to study security of $CO_2$ exhaust at night in indoor air quality purifying system using plants. For this purpose, two same units for experiment were built, and difference of $CO_2$ exhaust by existence and nonexistence of plantation were measured. To reduce error by entrance of people, automatic measurement system were developed and used. At first, baseline were measured to check standard value, and next, $CO_2$ exhaust by plantation were measured. As a result, in baseline experiment, values of all spaces were steady as 400~500 ppm. When plantation was set-up, value of $CO_2$ at night was measured high as 150 ppm, and maximum value was around 600 ppm. This result is a lot lower than maximum standard of $CO_2$, 1000 ppm.

계란의 신선도 결정과 영상분석을 이용한 내부품질 측정 (Determination of Egg Freshness and Internal Quality Measurement Using Image Analysis)

  • 김현태;고한종;김기연;가등굉랑;희다유자;서진귀구
    • Journal of Biosystems Engineering
    • /
    • 제32권3호
    • /
    • pp.166-172
    • /
    • 2007
  • Egg quality indices are related with freshness, size of air chamber, loss of weight, and viscosity of the yolk and the protein. However, since the described quality parameters require measured in a destructive way, it is not suitable to inspect the egg quality with complete enumeration. Therefore, this study was performed to investigate the potential of image analysis method for evaluation of internal egg quality. Samples of 90 fresh eggs were collected immediately after laying and stored up to 24 days. Five eggs were randomly drawn from each storage condition (packing vs unpacking) at a regular interval and loss of weight, specific gravity and size of air chamber were measured. The image analysis for nondestructive measurement of size of air chamber was also studied. Results showed that the egg weight and gravity gradually decreased with increasing of storage days, while the size of air chamber linear increased caused by evaporation of water through the shell. A relationship a between conventional method and the image analysis method for measuring the size of air chamber was developed with the correlation coefficient of 0.928. The new finding implied that image analysis might provide a useful nondestructive tool to assess internal egg quality.

대기오염측정망 정도관리의 문제점과 개선방향 (Problems and Improvements in the Quality Control of the Air Monitoring Network)

  • 김덕승;박정호
    • 한국환경과학회지
    • /
    • 제29권8호
    • /
    • pp.847-855
    • /
    • 2020
  • This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.

A study on BEMS-linked Indoor Air Quality Monitoring Server using Industrial IoT

  • Park, Taejoon;Cha, Jaesang
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권4호
    • /
    • pp.65-69
    • /
    • 2018
  • In this paper, we propose an interworking architecture for building indoor air quality monitoring server (BEMS) using IIoT (Industrial Internet of Things). The proposed monitoring server adopts IIoT-based standard protocol so that interaction with BEMS installed in existing buildings can be performed easily. It can effectively communicate with indoor air quality measurement sensor installed in the building based on IIoT, Indoor air quality monitoring is possible. We implemented a proposed monitoring server, and confirmed the availability and monitoring of data from sensors in the building.

무선네트워크기반 공기질 실시간 모니터링 시스템 (Real-time Air Quality Monitoring System Based on Wireless Network)

  • 백승현;이준영;정상우;박홍배
    • 대한임베디드공학회논문지
    • /
    • 제11권3호
    • /
    • pp.143-151
    • /
    • 2016
  • In this paper, a real-time air quality monitoring system based on wireless network is designed and implemented for industrial park or multiuse facilities. The existing gas detector is high price and hard to apply the remote monitoring system. On the other hand, demand for air quality monitoring is increasing because of industrial gas accident, air pollution, and so on. In Korea, indoor air regulation was established by law. According to indoor air regulation, CO2, CO, and NO2 are important gases as the air quality standard. So we study the gas detector for indoor air quality and the wireless network system. The wireless network consist of sensor network and WCDMA to apply various place. To verify the performance of the implemented gas detector, the gas measurement experiment is performed in laboratory environment by using the realized gas detecting wireless sensor node. And we evaluate the experiment results.

장기간(1997~2007) 창공관측을 이용한 서해상 SO2 및 NOx의 거동 연구 (Studies on the Behavior of SO2 and NOx over Yellow Sea Area during Long Term Aircraft Measurements(1997~2007))

  • 송형도;최진수;장임석;김정수;이석조
    • 한국환경과학회지
    • /
    • 제18권5호
    • /
    • pp.569-578
    • /
    • 2009
  • Aircraft Measurements of gaseous pollutants($SO_2$, NOx and $O_3$) in the Yellow Sea area, were carried out on 1997-2007. Main measurement site in 124$^{\circ}$-127$^{\circ}$E, 35$^{\circ}$-37$^{\circ}$N (in the Yellow Sea), have been done along the paths classified vertically and zonally. To understand how the air stream affects Long-range transboundary pollutants in Northease Asia (LTP), the tracks of pollutants in northeast Asia have been analyzed by dividing into 6 different regions(regions I-V and L). Compared with Korea's local sources and western north Pacific influenced by the Yellow Sea, when the air stream from region II is dominant, the $SO_2$ concentrations are 3-6times higher. In region II and III, $SO_2$ concentrations are represented highest at 25.0 and 14.7 ppb, respectively. However, in other regions, $SO_2$ concentration was recorderd the highest at 1.1-3.8 ppb, which is 7-15% higher then the highest one over the region II and III. During 1997-2007, the mean amount of incoming pollutants is 0.162 $ton/km{\cdot}hr$ exceeding about 5-times mean amount of outgoing pollutants over the West Sea. During the observed period, the amount of incoming and outgoing $SO_2$ over the Yellow Sea is the highest in winter, at 0.224 $ton/(km{\cdot}hr)$ and 0.120 $ton/(km{\cdot}hr)$, respectively.

이동 측정방법을 사용한 부산지역 주요 도로의 대기오염도 조사 (An Investigation into Air Quality of Main Roads in Busan using Mobile Platform Measurement)

  • 도우곤;정우식;유은철;곽진
    • 한국환경과학회지
    • /
    • 제22권9호
    • /
    • pp.1199-1211
    • /
    • 2013
  • Mobile sources produce a significant fraction of total anthropogenic emissions in Korea and have harmful effects on air quality. Mobile emissions are intrinsically difficult to estimate due to complicated road networks and variations of traffic volume with location and time. To measure traffic pollutants with high temporal and spatial resolution under real conditions a mobile laboratory was designed. The mobile laboratory provide concentrations of $SO_2$, CO, NO, $NO_2$ and location coordinate value. This approach allowed for pollutant level measurements on many roads within short periods of time. In this study, on-road concentrations of $SO_2$, CO, NO and $NO_2$ were measured using mobile platform measurement along the 25 main roads in Busan to estimate the average air pollution level in short time difference. The measurements were conducted on favorable meteorological days from 2010 to 2012 and the overall concentrations of $SO_2$, CO, NO and $NO_2$ were 0.006, 0.8, 0.182 and 0.055 ppm respectively. The result showed that the concentration of CO, NO and $NO_2$ on road were twice, 18 times and 2.5 times higher than regional air quality monitoring sites mean in same period.

주거용 화목난로의 대기오염 배출량 추정에 관한 연구 (A Study on Estimation of Air Pollutants Emission from Residential Wood Stove)

  • 김필수;장영기;김정;신용일;김정수;안준영
    • 한국대기환경학회지
    • /
    • 제26권3호
    • /
    • pp.276-285
    • /
    • 2010
  • Recently the Korean government has tried to cut down the $PM_{10}$ concentration by the Special Law for Air Quality Improvement. But the concentrations of $PM_{10}$ have exceeded the air quality standard at most monitoring stations. Primary $PM_{10}$ emitted from various sources and emission data have large uncertainty. The biomass burning is one of the major sources of $PM_{10}$ emission. The biomass burning is composed of wood stove usage, meat cooking and agricultural combustion etc.. Activity data and emission factors for the biomass burning are limited, and it is hard to calculate the air pollution emissions from these sources. In this study, we tried to estimate the air pollution emission from residential wood stove usage. The number of total wood stoves is estimated by the survey of wood stove manufacturer. And air pollution emission factors for the wood stove are investigated using the flue gas measurement by U.S. EPA particulate test method (Method 5G). As the results, the $PM_{10}$ and CO emission factors of wood stove are estimated as 7.7 g/kg-wood and 78.8 g/kg-wood respectively. The annual $PM_{10}$ and CO emissions from wood stove are calculated as 1,200~3,600 ton/year and 12,600~36,400 ton/year in Korea. It is confirmed that wood stove is the one of major sources of biomass burning, and the survey for activity data and the measurement for emission factors are needed for reducing the uncertainty of these emission data.

장기 노출 $SO_2$ 간이 샘플러 개발에 관한 연구 (A study on the development of long time exposure $SO_2$ sampler)

  • 이동인
    • 한국환경과학회지
    • /
    • 제2권3호
    • /
    • pp.207-216
    • /
    • 1993
  • The concentrations of $SO_2$ and $SO_3$ were measured to estimate a new developed long time exposure $SO_2$ sampler at Onsan industrial area considering the meteorological factors from June to October, 1992. The mean concentration of $SO_3$ by $PbO_2$ method was 0.924 mg $SO_3 / 10cm^2$ $PbO_2$/day and their high values were shown in the center of the industrial area, which show potential pollution due to the increase of industrial activities and micrometeorological factors in and around the sites. As a result of statistical correlation between $SO_2$ concentration by new sampling method and $SO_3$ concentration by $PbO_2$ method in July and August, 1992, correlation coefficients were high (r=0.87, 0.91) and shown more than 0.83 value in the high concentration data set, which was arbitrarily divided into 7~10${\mu}l$$SO_2$ concentration in an attempt to further investigate these relationships. Therefore, use of new developed long time exposure TEX>$SO_2$ sampler is good for TEX>$SO_2$ measurement and valuable for estimation of air quality in the urban and industrial area. Key Words : a new developed long time exposure TEX>$SO_2$ sampler, correlation coefficients, high, $SO_2$ measurement, estimation of air Quality.

  • PDF