• Title/Summary/Keyword: Air purification

Search Result 230, Processing Time 0.027 seconds

Anaerobic Digester Gas Purification for the Fuel Gas of the Fuel Cell (연료전지 연료가스인 하수처리장 소화가스정제)

  • Lee, Jong-Gyu;Jun, Jae-Ho;Park, Kyu-Ho;Choi, Doo-Sung;Park, Jae-Young
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.2
    • /
    • pp.164-170
    • /
    • 2007
  • The Tancheon wastewater treatment plant(WWTP) in Seoul using anaerobic digestion to reduce the outlet sludge produces anaerobic digester gas which contains 65% $CH_4$ and 35% $CO_2$. The gas purification equipment was installed and operated to use Anaerobic Digester Gas(ADG) as a fuel for molten carbonate fuel cell(MCFC). The processes consist of the desulfurizer and the adsorption tower to remove $H_2S$ and siloxane in the gas. The gas purification equipment removed virtually over 95% of $H_2S$ and over 99% of siloxane. Results has demonstrated that the fuel cell can produce electrical output and hot water with negligible air emissions of CO, NOx and $SO_2$. The site provides the first opportunity in Korea for demonstrating Molten carbonate fuel cell(MCFC) which the digester gas was applied to the fuel gas.

Effective Purification of Ginsenosides from Cultured Wild Ginseng Roots, Red Ginseng, and White Ginseng with Macroporous Resins

  • Li, Huayue;Lee, Jae-Hwa;Ha, Jong-Myung
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.11
    • /
    • pp.1789-1791
    • /
    • 2008
  • This study was aimed (i) to develop an effective method for the purification of ginsenosides for industrial use and (ii) to compare the distribution of ginsenosides in cultured wild ginseng roots (adventitious root culture of Panax ginseng) with those of red ginseng (steamed ginseng) and white ginseng (air-dried ginseng). The crude extracts of cultured wild ginseng roots, red ginseng, and white ginseng were obtained by using a 75% ethanol extraction combined with ultrasonication. This was followed sequentially by AB-8 macroporous adsorption chromatography, Amberlite IRA 900 Cl anion-exchange chromatography, and Amberlite XAD16 adsorption chromatography for further purification. The contents of total ginsenosides were increased from 4.1%, 12.1%, and 11.3% in the crude extracts of cultured wild ginseng roots, red ginseng, and white ginseng to 79.4%, 71.7%, and 72.5% in the final products, respectively. HPLC analysis demonstrated that ginsenosides in cultured wild ginseng roots were distributed in a different ratio compared with red ginseng and white ginseng.

A Rapid and Simple Homogenizing Method for the Purification of Single-walled Carbon Nanotubes

  • Choi, Sang-Kyu;Jung, Seung-Il;Lee, Seung-Beck
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.209-212
    • /
    • 2008
  • We developed a simple and effective purification method to obtain high-purity single-walled carbon nanotubes (SWCNTs) with low surface damage. The purification process consists of oxidization at $430^{\circ}C$ for 1 h in a furnace system of air atmosphere and homogenization in dilute hydrochloric acid solution for extremely short time. The role of homogenizer was examined during purification process in terms of purity and quality of purified SWCNTs. High-purity and low surface damage of SWCNT products was obtained using homogenizer which was operated at 8500 rpm for 10 min in the environment of 7 % HCI solution. From XRD spectra, we observed that metal catalysts were thoroughly removed. Raman spectra showed that the intensity values of crystallization ($I_{G}/I_{D}$) of purified SWCNTs were very similar with that of pristine SWCNTs. Moreover, the structure damage of purified SWCNTs was hard to find from electron microscopy. Consequently, homogenizing, which is a quick and simple manner, can be promising method for obtaining final SWCNTs with clearly high purity and crystallinity.

A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic

  • Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.11
    • /
    • pp.143-149
    • /
    • 2018
  • The purpose of this study is to propose a management method to maintain the pleasant indoor air quality of the dental clinic by measuring and analyzing the indoor air quality of the dental clinic. The measurement was conducted in two rooms, a lobby where many residents stay in the reception room for waiting for medical treatment, and a VIP room where treatment activities are mainly performed. Measurement items are Temperature, Humidity, $CO_2$, CO, $NO_2$, $CH_2O$, VOC, $PM_{10}$ and measurement were taken on April 27, 2018. As a result of analyzing the temperature and humidity of the dental clinic, it was analyzed that the average indoor temperature was maintained at $25^{\circ}C$ and the humidity was kept at around 50%, maintaining proper indoor temperature and humidity environment. $CO_2$ was 855ppm in the VIP Room, which satisfied the maintenance standard. In the case of the lobby, it was analyzed to be 1,160ppm, which exceeded the maintenance standard and it is judged that the carbon dioxide generated by the respiration of the people staying in the lobby is the main reason. The mean concentration of formaldehyde in the VIP room was analyzed as $436{\mu}g/m^3$, exceeding the maintenance standard, and $2,100{\mu}g/m^3$ for the VOC exceeded the recommended standard. It was analyzed that the concentration was relatively higher due to the use of disinfectant and other drugs. The mean concentration of PM-10 in the lobby was analyzed as $65{\mu}g/m^3$ and it was analyzed that it satisfied the maintenance standard. To maintain a pleasant indoor air quality in a dental clinic it is necessary to minimize the effects of formaldehyde, VOC, $CO_2$ in the VIP rooms and lobby. For this purpose, the entire ventilation system and air purification system of the dental clinic should be installed. In case of the VIP room, local exhaust ventilation should be installed and workers should wear personal protective equipment.

The Impact of Negative Ions and Plant Volume Changes in Space on Fine Dust Purification in the Atmosphere (공기 중 음이온과 공간 내 식물용적 변화가 미세먼지 정화에 미치는 영향)

  • Deuk-Kyun Oh;Jeong-Ho Kim
    • Korean Journal of Environment and Ecology
    • /
    • v.38 no.2
    • /
    • pp.217-226
    • /
    • 2024
  • This study aimed to investigate the influence of anions in the air on the purification of fine dust (PM10 and PM2.5) and to evaluate the effects of plants on the generation of anions in the air and the purification of fine dust. Subsequently, the fine dust reduction models were compared according to each factor and plant volume. The characteristics of anion generation by each factor were observed to be in the order of Type N.I (negative ion generator; 204,133.33 ea/cm3) > Type P30 (plant vol. 30%; 362.55 ea/cm3) > Type C (control; 46.22 ea/cm3), indicating that the amount of anion generation in the anion generator treatment group and the plant arrangement group were approximately 4,417 times and 7 times higher, respectively, than that in the untreated group. Consequently, the fine dust reduction characteristics by anion generation source showed that for PM10, Type NI had a purification efficiency 2.52 times higher than Type C, and Type P30 was 1.46 times higher, while for PM2.5, Type NI had a purification efficiency 2.26 times higher than Type C, and Type P30 was 1.31 times higher. The efficiency of fine dust purification by plant volume was in the order of Type P20 (84.60 minutes) > Type P30 (106.50 minutes) = Type P25 (115.50 minutes) = Type P15 (117.60 minutes) > Type P5 (125.25 minutes) = Type P10 (129.75 minutes), and for ultrafine dust, Type P20 (104.00 minutes) > Type P30 (133.20 minutes) = Type P25 (144.00 minutes) = Type P15 (147.60 minutes) > Type P5 (161.25 minutes) = Type P10 (168.00 minutes). Thus, a quantitative analysis of the anions and plants for purifying fine dust and suggested matters to be considered for future green space planning and plant planting considering fine dust purification.

Technology of VOC Removal in Air by Biotrickling Filter (생물살수여과법을 이용한 공기 중 VOC 제거 기술)

  • ;Marc A. Deshusses
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.1
    • /
    • pp.101-112
    • /
    • 2003
  • Biological methods are frequently used for treatment of contaminated air, containing volatile organic compounds and odor compounds in low concentrations and high flow rate of air streams. For more than 20 years. biofilter has been recognized as a cost effective technology for the purification of contaminated air. Most commercial applications before 1990 were for control of odors. In the past decades major progress has been accomplished in the development of vapor phase bioreactor. in particular biotrickling filers. Biotrickling filters are more complex than biofilters. but are usually more effective, especially for the treatment of compounds which are difficult to degrade or compounds that generate acidic by-products. While the level of understanding of biotrickling filtration process for VOCs still remains limited. the evidence success of biotreatment of VOC in air resulted in pursuing active research. This paper presents fundamental and practical aspert of VOCs treatment from air in biotrickling filter. Special emphasis is given to the operating parameters and the factors influencing performance for biotrickling filter.

A Study on Hydraulic Behavior and Mass Transfer by Absorption in Packing Tower (충전탑에서 흡수에 따른 물질전달과 수력학적 거동에 관한 연구)

  • 김석택
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.393-396
    • /
    • 2000
  • Packing tower has been used in the chemical industry and the protection of environment for a long time. In the view of environmental protection purification of exhaust gas can be performance effective by gas absorption in counter-current packing tower. In this study characteristics of hydraulic and mass transfer were investigated in D. $0.3m {\times} H. 1.4m$ packing tower with 50mn plastic Hiflow-ring. This study was carried out "Test systems were experimented in conditions of Air, $Air/H_2O. NH_3-Air/H_2O, NH_3-Air/H_2O-H_2SO_4$ and $SO_2-Air/H_2O-NaOH$ under steady state" The extent of test included dry and wetting pressure drop physical law separation efficiency and hold-up as function of gas and liquid load.quid load.

  • PDF

Emission After-Treatment System of Model Gas Turbine Using Catalyst (촉매를 이용한 모형가스터빈 연소기의 배기후처리 시스템)

  • Lee, Y.H.;Lee, J.S.;Bae, D.S.;Lee, D.H.
    • Journal of Power System Engineering
    • /
    • v.7 no.3
    • /
    • pp.12-17
    • /
    • 2003
  • The purpose of this study is to observe the purification characteristics of NOx, CO and HC in various catalysts and excess air ratio conditions. For this purpose, we installed various catalysts on the back stream of the coaxial diffusion burner with swirler. As the result, in the case of NOx, Pt-Rh catalyst shows very high value that is more than 90%-conversion efficiency without the relation with the excess air ratio. After excess air ratio of ${\alpha}=1.14$, it shows that the conversion efficiencies were more than 80% in the every Pt catalyst in the view of conversion of every exhaust with changing of the excess air ratio.

  • PDF

Phytoremediation of Urban Air Pollution

  • Fang, Qin;Wang, Yun;Jin, Jie
    • Journal of Urban Science
    • /
    • v.8 no.2
    • /
    • pp.35-39
    • /
    • 2019
  • With the rapid progress of society and economic growth, more and more factories are put into construction, although to a certain extent to promote the development of our country's economy, but the waste gas and waste water produce also harm the environment.Among them, air pollution causes great damage to the environment and harms human health.In order to protect people's safety and health, people began to look for some measures to control air pollution, one of the most effective way is to plant more green plants, using plants for air purification.