Comparison of TVOCs emission characterization of paint and putty according to the amendment of test specimen preparation method (시험편 제작방법 변경에 따른 페인트, 퍼티의 TVOCs의 방출 특성 비교)

  • Park, Joon-Man;Yoo, Ji-Ho;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.109-118
    • /
    • 2010
  • Amended at the Law of indoor air quality management open a court according to the test method and excess standard of the fluid building material were changed. It used the paint and the putty in the fluid building material from this research and comparison of amended and original method it led and in about change direction of amended standard with change of the emission rate who is caused by in the amended test method and excess standard it examined. The reduction emission rate about 45% decreases in the change of test period of the paint, there was not an effect of the emission rate whom it follows in change of dry time. Also change of the emission rate whom it follows in change of application quantity the product which above $5\;mg/m^2h$ has the high emission rate the change of the emission rate is big but there was not change of the emission rate from the products of that others. The putty the emission rate about 61% decreases in case in the change of test period, there was not an effect of the emission rate whom it follows at dry time. The emission rate about 164% increased with increase of application quantity. It tried to compare two test methods, it compared in the paint and putty all current test method it was relaxed the possibility of knowing the thing there was a standard.

The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect (여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석)

  • Lee, Jun-ho;Yang, Seung-ho;Bang, Ki-woong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

Validation and Calibration of TUNVEN Model (TUNVEN 모형의 검증 및 보정)

  • Cheong, Jang-Pyo;Yoon, Sam-Seok;Yi, Seung-Muk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.785-796
    • /
    • 2000
  • In this study, the possibility of application of TUNVEN model was investigated through the validation and calibration processes. In order to validate and calibrate the TUNVEN model developed in USA to obtain prediction of the quasi-steady state longitudinal air velocities and the pollutants concentrations by solving the coupled one-dimensional steady state tunnel aerodynamic and advection equations. The major input parameters such as the concentration data for CO and $NO_x$, meteorological data and traffic volume in Hawngryung tunnel were measured. Prior to preparing the input parameters, the sensitivity analysis was conducted to identify the input parameters which need to be most accurately estimated in TUNVEN program. In order to establish the relationships between the model values and the measured values, the linear regression analysis was applied. In linear regression analysis, the model values were taken as independent parameter(X) and the measured values were taken as dependent parameter(Y) for four cases of data sef. From the results of linear regression analysis, the correlation coefficient(r) for four cases were calculated more than 0.91 and the values of slope and interception were analyzed as 0.5~2.2 and 0.01~2.3 respectively. From the above results, we concluded that the suitability of TUNVEN model was identified in prediction the longitudinal pollutant concentrations in tunnel.

  • PDF

Exposure to PAHs and VOCs in Residents near the Shinpyeong·Jangrim Industrial Complex (신평·장림 산단 인근 주민의 PAHs 및 VOCs 노출)

  • Yoon, Mi-Ra;Jo, HyeJeong;Kim, GeunBae;Chang, JunYoung;Lee, Chul-Woo;Lee, Bo-Eun
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.2
    • /
    • pp.131-143
    • /
    • 2021
  • Objectives: This study aims to investigate the atmospheric concentration of polycyclic aromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs) and the urinary concentration of biomarkers in residents near the Shinpyeong·Jangrim Industrial Complex to compare them with those of residents in a control area. Methods: Hazardous air pollutants (PAHs and VOCs) were measured in an exposure area (two sites) and a control area (one site). Urine samples were collected from residents near the industrial complex (184 persons) and residents in the control area (181 persons). Multiple linear regression analysis was used to identify which factors affected the concentration of PAHs and VOCs metabolites. Results: The average atmospheric concentration of PAHs in Shinpyeong-dong and Jangrim-dong was 0.45 and 0.59 ppb for pyrene, 0.15 and 0.16 ppb for benzo[a]pyrene, and 0.29 and 0.35 ppb for dibenz[a,h]anthracene. The average atmospheric concentration of VOCs was 1.10 and 0.99 ppb for benzene, 8.22 and 11.30 ppb for toluene, and 1.91 and 3.05 ppb for ethylbenzene, respectively. The concentrations of PAHs and VOCs in residents near the Shinpyeong·Jangrim Industrial Complex were higher than those of residents in the control area. Geometric means of urinary 2-hydroxyfluorene, 1-hydroxypyrene, methylhippuric acid, and mandelic acid concentrations were 0.45, 0.22, 391.51, and 201.36 ㎍/g creatinine, respectively. Those levels were all significantly higher than those in the control area (p<0.05). In addition, as a result of multiple regression analysis, even after adjusting for potential confounding factors such as gender and smoking, the concentration of metabolites in urine was high in residents near the Shinpyeong·Jangrim Industrial Complex. Conclusion: The results of this study show the possibility of human exposure to VOCs in residents near the Shinpyeong·Jangrim Industrial Complex. Therefore, continuous monitoring of the local community is required for the management of environmental pollutant emissions.

A Study on the Fine Dust Removal Equipment of Pressurized Water type for the Removal of Exhaust Gas Fine Dust and Volatile Organic Compounds from the Non-industrial combustion plant (비산업 연소 사업장 배출 가스상 미세먼지와 휘발성 유기 화합물 제거를 위한 가압수식 미세먼지 제거 장치 연구)

  • Youn, Jae-Seo;Kim, Sang-Min;Lee, Ye-Ji;Noh, Seong-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.506-512
    • /
    • 2018
  • The fine dust generated in the home and restaurant business occupies a low ratio of about 4% of the total fine dust emissions. However, at the foodservice business, the rate of change of the pollutant concentration is very high, so that the temporary fine dust concentration can be measured up to 60 times. The pollutants generated from non-industrial combustion plants consist of particulate fine dust and gaseous organic compounds. To remove these pollutants, cleaning dust collection system, which is an effective system for simultaneous removal of gaseous and particulate matter, is applied. This is a method of increasing the probability of diffusion capture of the Brownian motion by pressurized liquid injection method using the atomizing nozzle. The dust removal efficiency of the fine dust collecting system was analyzed by nozzle spraying air pressure condition and angle using the manufactured fine dust removing system. As a result, it was confirmed that the efficiency of removal of fine dust and gaseous organic compounds was more than 90%. The developed system is expected to be highly usable in the future because it can remove particulate dust from the existing plant hood system without any installation cost.

A Study on the Optimization of Active Material and Preparation of Granular Adsorbent of Metal Oxide-based Adsorbent for Adsorption of Hydrogen Sulfide (H2S) (황화수소(H2S) 흡착을 위한 금속산화물 기반 흡착제의 활성물질 최적화 및 입상형 흡착제 제조에 대한 연구)

  • Choi, Sung Yeol;Han, Dong Hee;Kim, Sung Su
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.460-465
    • /
    • 2019
  • In this study, the optimization of active materials and the preparation of particulate adsorbents for the application of metal oxide-based adsorbents for the treatment of $H_2S$, an air pollutant and odorant, occurred in various industrial facilities were investigated. The adsorbents were prepared by using $TiO_2$, which has a high physicochemical stability and relatively high specific surface area among metal oxides and also by different kinds and contents of active materials. The correlation between the physicochemical property and adsorption performance of the adsorbents confirmed that the adsorbent containing KI, which is a typical alkali metal among the active metals, showed the highest adsorption performance. The relationship between the contents and the adsorption performance was non-proportional, but a volcano plot. From XRD, SEM and BET analyses, it was confirmed that the active material was exposed to the surface above a certain amount and also the adsorption performance was the best when the specific surface area and pore volume were $40{\sim}100m^2/g$ and $0.1{\sim}0.3cm^3/g$, respectively. For practical application, the adsorbent was granulated or coated on a ceramic support. It was also confirmed that the adsorbent showed high adsorption performance when the adsorbent was coated on the ceramic rather than that of the granulated support.

Exposure and Risk Assessment of Nitrogen Dioxide and Ozone for Sub-population Groups using Monte-Carlo Simulations (Monte-Carlo 모의실험을 통한 부분 인구집단별 이산화질소와 오존의 노출 및 위해성 평가)

  • Park, Jinhyeon;Ryu, Hyeonsu;Yang, So Young;Park, Yunkyung;Heo, Jung;Kim, Eunchae;Choe, Youngtae;Cho, Mansu;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.2
    • /
    • pp.113-125
    • /
    • 2019
  • Objectives: Although the risk assessments for nitrogen dioxide ($NO_2$) and ozone ($O_3$) have been extensively studied, most of the existing risk assessments were limited mainly to indoor environments such as workplaces, schools, and multi-use facilities. Therefore, integrated risk assessment is needed to consider exposure in all microenvironments, including outdoors. The purpose of this study was to assess the differences in risk among sub-population groups according to time-activity patterns and reported concentrations, as well as the lifetime risk of Koreans. Methods: In this study, we estimated time-weighted average exposure concentrations of $NO_2$ and $O_3$ for preschool children, students, housewives, workers, and seniors using residential time and indoor concentrations (house, school or workplace, other), outdoors, and transport by meta-analysis method. The risk for $NO_2$ and $O_3$ were assessed by hazard quotient using reference concentrations 30 and 60 ppb, respectively. The risk assessments were conducted through 1,000,000 Monte-Carlo simulations for probabilistic analysis. Results: Preschool children, students, housewives, workers, and seniors spent 91.9, 86.0, 79.8, 82.2, and 77.3% of their day in a house, school, or workplace, respectively. The risk assessment for the lifetime of a housewife and a worker showed that 33.8 and 28.4% of hazard quotients of $NO_2$ exceed 1, respectively, and more than 99% of hazard quotient of $O_3$ were less than 1. Conclusions: The risk of $NO_2$ and $O_3$ by sub-population group and for the lifetime of housewives and workers were assessed. The risk for $NO_2$ was higher than for $O_3$ and showed a different risk by sub-population group. Both $NO_2$ and $O_3$ showed a higher risk for housewives than for workers. This study can be used as a basis for lifetime exposure and risk assessment for $NO_2$ and $O_3$.

Material Scientific Properties and Effects on Atmospheric Environment of Copper Rust Pigments (동록안료의 재료과학적 특성 및 대기환경 영향 평가)

  • Park, Ju Hyun;Kim, Myoung Nam;Park, Se Rin;Yu, Ji A;Kim, Su Kyoung;Lee, Sun Myung
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.4
    • /
    • pp.361-376
    • /
    • 2020
  • Atacamite and Verdigris were studied material scientific properties and durability that are used for traditional green pigment in traditional art painting work and Dancheong. As a result of ingrediant analysis, K-AA and K-VA identified Atacamite and Hoganite (or Verdigris) respectively. In order to find a factor of depressing the stability of pigment, we examined UV radiant exposure test, CO2/NO2 gas corrosion test and salt spray test. Salt spray test damaged both samples which were formed salt particle on the surface of the samples and it makes color disability. Furthermore, the results of gas corrosion test that both pigments change color enough to be perceived by the naked eyes showed that an air pollutant NO2 gas is also considered to be a major damage factor. In the case of K-VA, Hoganite that is main component of sample changes Tenorite with turn black after accelerated UV radiant exposure test. The consequences of the atmospheric environment effect test of the two pigments, K-VA showed relatetively weaker than K-AA.

Preliminary Study on GIS Mapping-based Fine Dust Measurement in Complex Construction Site (단지조성공사 내 드론을 활용한 GIS 맵핑 기반 미세먼지 측정 시스템 기초 연구)

  • Lee, Jaeho;Han, Jae Goo;Kim, Young Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.319-325
    • /
    • 2021
  • A fine dust measurement using drones is becoming an increasingly common technology, and air pollutants can be identified through dust monitoring in partial industrial areas. A station for measuring fine dust provides information at large construction site offices. On the other hand, it was difficult to check the fine dust in the pollutant source accurately. Therefore, the drone took measurements directly after been placed at the site. While measuring fine dust, monitoring noise occurred due to the influence of the drone's down-wind during landing, but the measurements were similar to the numerical value of the grounded pollution source on the height of 30 m. The field applicability to the study area has limitations in periodic updates using satellite images because the terrain was constantly changing due to considerable flattening fieldwork. Therefore, this study implemented a system that can reflect real-time field information through GIS mapping using drones.

Microbial Metagenome of Airborne Particulate Matter: Methodology, Characteristics, and Influencing Parameters (대기입자상물질의미생물메타게놈: 분석방법, 특성및영향인자)

  • Kang, Sookyung;Cho, Kyung-Suk
    • Microbiology and Biotechnology Letters
    • /
    • v.50 no.2
    • /
    • pp.165-192
    • /
    • 2022
  • The microbial metagenome characteristics of bioaerosols and particulate matter (PM) in the outdoor atmospheric environment and the effects of climate and environmental factors on the metagenome were analyzed. The concentrations of bacteria and fungi in bioaerosols and PM were determined by sampling different regions with different environmental properties. A variety of culture-independent methods were used to analyze the microbial metagenome in aerosols and PM samples. In addition, the effects of meteorological and environmental factors on the diversity and metagenomes of bacteria and fungi were investigated. The survival, growth, and dispersal of the microorganisms in the atmosphere were markedly affected by local weather conditions and the air pollutant concentration. The concentration of airborne microorganisms increased as the temperature increased, but their concentration decreased in summer, due to the effects of high temperatures and strong ultraviolet rays. Humidity and microbial concentration were positively correlated, but when the humidity was too high, the dispersion of airborne microorganisms was inhibited. These comprehensive data on the microbial metagenome in bioaerosols and PM may be used to understand the roles and functions of microorganisms in the atmosphere, and to develop strategies and abatement techniques to address the environmental and public health problems caused by these microorganisms.