• 제목/요약/키워드: Air plane

검색결과 476건 처리시간 0.022초

수직배치 구대평판 공기 갭에서 연소화염 존재시의 절연파괴 특성 (Breakdown Characteristics of a Vertical Sphere-Plane Air Gap in the Presence of Combustion Flame)

  • 김인식
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.79-84
    • /
    • 2011
  • In this study, breakdown characteristics of a vertical sphere-plane air gap in the presence of combustion flame were examined under the application of a.c. and d.c. high-voltages in order to investigate the effect of flame on the dielectric strength of air. Propane gas is used as the fuel of the flame, and the temperature distribution of air around the flame is measured. The polarity effects for the d.c. voltages and breakdown voltages of air when applied both of a.c. and d.c. voltages were examined in the case of the variation of the gap length and the horizontal distance between the flame and the high-voltage sphere electrode. The influence of relative air density, electrification and shape changes of the flame as factors that affect the breakdown voltages were discussed.

무게중심 변화에 따른 초음속 공중발사 로켓의 모선분리 연구 (Center-of-Gravity Effect on Supersonic Separation from the Mother Plane)

  • 지영무;이재우;변영환;박준상
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.36-40
    • /
    • 2006
  • 초음속 공중발사 로켓의 모선분리에 대한 유동해석을 수행하였다. 모선(F-4E Phantom)에서 분리되는 로켓주변 유동장의 정상/비정상 유동해석을 위해 압축성 Wavier-Stokes방정식이 사용되었으며, 해석결과는 모선과 로켓간의 충격파-팽창파 간섭효과를 잘 보여주고 있다. 무게중심의 변화에 따른 로켓의 거동을 예측하기 위하여 세 가지 경우에 대한 전산해석을 수행하였으며, 결과적으로 초음속 공중발사 로켓의 안전한 모선분리를 위한 설계 가이드라인을 제시 하였다.

  • PDF

765kV급 송전선로 공기절연거리 설정을 위한 시험전극의 섬락전압 특성 (The Flashover Characteristics of Test Electrodes against Clearance of Air Insulation for 765kV Transmission Line)

  • 김윤택;김영배;이형호;김정문;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1337-1340
    • /
    • 1995
  • For the purpose of rational design of air insulation, it is need to experiment with similar to real shape test object and conform the characterisics. But basic distances of air insulation of transmission line, tower, etc. can be acquired from flashover characteristic of rod-rod, rod-plane electrodes. In this paper, before field test of 765kV transmission line for determination of distances of phase to ground insulation, we execute lightning, switching impulse test with test electrod(rod-rod, rod-plane) against clearances of air insulation. Each tests use up-down method and consist of 30 times flashover test. Flashover data treatment program and air correction program following IEC 60-1(1987) standard were completely builted.

  • PDF

공중발사체의 1단 하이브리드 모터 최적설계 (Optimal Design of Hybrid Motor for the First Stage Air Launch Vehicle)

  • 박봉교;권순탁;이재우;이창진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.20-24
    • /
    • 2003
  • The feasibility of hybrid motor as a first stage of the air launch vehicle is investigated, and the result shows the hybrid motor can replace the solid motor. Optimal design study has been performed for the hybrid motor as a first stage of nanosat air launch vehicle. The first stage hybrid motor of the nanosat air launch vehicle, which uses the F-4E Phantom as a mother plane is designed for given mission requirements. Selected design variables are the number of ports, the initial oxidizer flux, the combustion chamber pressure, and the nozzle expansion ratio. The design results show that a hybrid motor can be successfully applicable to very small air launch vehicles which have severe physical constraints of length and diameter imposed by the mother plane.

  • PDF

이격거리가 큰 전극의 공기 절연파괴에 영향을 미치는 인자측정에 관한연구 (A Study on the Measurements of Parameters Affecting the Breakdown Mechanism of a Large Air Spacing)

  • 조연옥;최영욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.756-760
    • /
    • 1988
  • The paper presents the measurement results on the parameters affecting the breakdown mechanism of a large air spacing under switching impulse voltages. Measured parameters are the velocities of leader channels, predischarge currents, electric charges injected into the rod-plane air gap and electric field intensities on the plane. For the 3m air gap under switching impulse voltages, the velocities of leader channel have been measured to be of 1cm/${\mu}s$ - 5cm/${\mu}s$, electric field intensity of 2kv/cm, predischarge current of 1.2A - 1.6A, the charges injected into the air gap of 11 - 40 ${\mu}$C for 400-887kV impulse voltages.

  • PDF

이격거리가 큰 전국의 공기절연파괴 현상시 발생하는 인자측정에 관한 연구 (A Study on the Measurements of Discharge Parameters in Case of the Switching Impulse Breakdown of a Large Air Spacing)

  • 최영욱;조연옥
    • 대한전기학회논문지
    • /
    • 제40권12호
    • /
    • pp.1290-1295
    • /
    • 1991
  • The paper presents the measurement results on the parameters affecting the breakdown mechanism of a large air spacing under switching impulse voltages. Measured parameters are the velocities of leader channels, predischarge currents, electric charges injected into the rod-plane air gap and electric field intensities on the plane. For the 3m air gap under switching impulse voltages, the velocities of leader channel have been measured to be of 1cm/x10S0-6Ts - 5cm/x10S0-6Ts, electric field intensity of 2kv/cm, predischarge current of 1.2-1.6A, the charges injected into the air gap of 11-40x10S0-6TC for 400-887kV impulse voltages.

  • PDF

초음속 공중발사 로켓의 모선분리 현상에 관한 수치적 연구 (A Numerical Study on the Supersonic Separation of Air-launching Rocket from the Mother Plane)

  • 지영무;김영신;이재우;박준상
    • 한국항공우주학회지
    • /
    • 제33권8호
    • /
    • pp.18-25
    • /
    • 2005
  • 본 논문에서는 공중발사로켓의 초음속 모선 분리 현상에 관하여 기술하였다. 정상상태와 비정상상태의 해석을 위하여 3차원 Euler방정식을 수치적으로 계산하였다. 해석결과는 모선과 로켓사이의 충격파 간섭현상을 명확히 보여주고 있으며, 로켓의 분리 단계에 중요한 영향을 미치는 인자들을 해석을 통해 찾아내었다. 결과적으로 본 연구를 통하여 초음속 공중발사로켓의 설계에서의 안전한 모선분리를 위한 가이드라인을 제공하였다.

침-평판 전극 구조에서 발생하는 기중 코로나 방전의 해석 기법 (Analysis Techniques of Corona Discharges in Air with Needle-Plane Electrode System)

  • 강성화;박영국;권순석;정수현;류부형;임기조
    • 한국안전학회지
    • /
    • 제11권4호
    • /
    • pp.49-53
    • /
    • 1996
  • Corona discharges in air insulated electric power systems cause power loss, produce interfering electromagnetic radiation, and can indicate incipient failure. An understanding of corona discharges in air gap is clearly Important. The Wavelet transformation is an extended method of fourier transformation. The fourier method is a powerful tool for signal analysis, but it can't include information for time. However the wavelet transformation analysis can include on the information of time and frequencies at the same time. In this paper we apply the wavelet transformation to the corona signals in needle-plane air gap for the purpose of analysis of developing aspects of corona discharges. We analyzed the developing aspects of corona discharges, namely, corona discharge current, repetition rates, width of Pulse distribution region, pulseless region and frequencies distribution of corona discharge pulses.

  • PDF

2열 휜 튜브 열교환기의 공기측 압력강하 및 열전달 특성을 고찰하기 위한 확대 모형실험 (A large scale model test to investigate the pressure drop and heat transer characteristics in the air side of two-row heat exchanger)

  • 강희찬;김무환
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.113-124
    • /
    • 1997
  • This work is performed to investigate the pressure drop and heat transfer characteristics in the air side of finned-tube heat exchanger for air conditioner. Experimental apparatus and method are described to simulate the heat exchanger performance by using the three times enlarged model. The pressure drop and heat transfer coefficient were measured and compared for the heat exchangers with a plane fin and a commercial strip fin. The measured data for the strip fin agree well with those of prototype within a few percentages. For the plane fin, the measured data had similar trend to Gray & Webb's correlation at high air velocity, however a new correlation is needed to give more accurate prediction at low air velocity. It is found that most heat was transferred around the front row of the two-row heat exchanger, and the ratio of thermal load at the front tube row was increased for decreasing air velocity.

평면 점성 정체 유동 응고 문제에 대한 이론적 해석 (A theoretical analysis on the viscous plane stagnation-flow solidification problem)

  • 유주식
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.260-270
    • /
    • 1998
  • The viscous plane stagnation-flow solidification problem is theoretically investigated. An analytic solution at the beginning of solidification is obtained by expanding the temperature and thickness of solidified layer in powers of time. An exact expression for the steady-state thickness of solidified layer is also obtained. The .fluid flow toward the cold substrate inhibits the solidification process. As Stefan number becomes larger, or Prandtl number becomes smaller, the solidification is more strongly inhibited by the fluid flow. The transient heat flux at the liquid side of solid-liquid interface is increased, as Stefan number or Prandtl number is increased.

  • PDF