• 제목/요약/키워드: Air monitoring sites

검색결과 150건 처리시간 0.034초

대기오염집중측정소별 2013~2015년 사이의 PM2.5 화학적 특성 차이 및 유발인자 조사 (Difference in Chemical Composition of PM2.5 and Investigation of its Causing Factors between 2013 and 2015 in Air Pollution Intensive Monitoring Stations)

  • 유근혜;박승식;김영성;신혜정;임철수;반수진;유정아;강현정;서영교;강경식;조미라;정선아;이민희;황태경;강병철;김효선
    • 한국대기환경학회지
    • /
    • 제34권1호
    • /
    • pp.16-37
    • /
    • 2018
  • In this study, difference in chemical composition of $PM_{2.5}$ observed between the year 2013 and 2015 at six air quality intensive monitoring stations (Bangryenogdo (BR), Seoul (SL), Daejeon (DJ), Gwangju (GJ), Ulsan (US), and Jeju (JJ)) was investigated and the possible factors causing their difference were also discussed. $PM_{2.5}$, organic and elemental carbon (OC and EC), and water-soluble ionic species concentrations were observed on a hourly basis in the six stations. The difference in chemical composition by regions was examined based on emissions of gaseous criteria pollutants (CO, $SO_2$, and $NO_2$), meteorological parameters (wind speed, temperature, and relative humidity), and origins and transport pathways of air masses. For the years 2013 and 2014, annual average $PM_{2.5}$ was in the order of SL ($${\sim_=}DJ$$)>GJ>BR>US>JJ, but the highest concentration in 2015 was found at DJ, following by GJ ($${\sim_=}SJ$$)>BR>US>JJ. Similar patterns were found in $SO{_4}^{2-}$, $NO_3{^-}$, and $NH_4{^+}$. Lower $PM_{2.5}$ at SL than at DJ and GJ was resulted from low concentrations of secondary ionic species. Annual average concentrations of OC and EC by regions had no big difference among the years, but their patterns were distinct from the $PM_{2.5}$, $SO{_4}^{2-}$, $NO_3{^-}$, and $NH_4{^+}$ concentrations by regions. 4-day air mass backward trajectory calculations indicated that in the event of daily average $PM_{2.5}$ exceeding the monthly average values, >70% of the air masses reaching the all stations were coming from northeastern Chinese polluted regions, indicating the long-range transportation (LTP) was an important contributor to $PM_{2.5}$ and its chemical composition at the stations. Lower concentrations of secondary ionic species and $PM_{2.5}$ at SL in 2015 than those at DJ and GJ sites were due to the decrease in impact by LTP from polluted Chinese regions, rather than the difference in local emissions of criteria gas pollutants ($SO_2$, $NO_2$, and $NH_3$) among the SL, DJ, and GJ sites. The difference in annual average $SO{_4}^{2-}$ by regions was resulted from combination of the difference in local $SO_2$ emissions and chemical conversion of $SO_2$ to $SO{_4}^{2-}$, and LTP from China. However, the $SO{_4}^{2-}$ at the sites were more influenced by LTP than the formation by chemical transformation of locally emitted $SO_2$. The $NO_3{^-}$ increase was closely associated with the increase in local emissions of nitrogen oxides at four urban sites except for the BR and JJ, as well as the LTP with a small contribution. Among the meterological parameters (wind speed, temperature, and relative humidity), the ambient temperature was most important factor to control the variation of $PM_{2.5}$ and its major chemical components concentrations. In other words, as the average temperature increases, the $PM_{2.5}$, OC, EC, and $NO_3{^-}$ concentrations showed a decreasing tendency, especially with a prominent feature in $NO_3{^-}$. Results from a case study that examined the $PM_{2.5}$ and its major chemical data observed between February 19 and March 2, 2014 at the all stations suggest that ambient $SO{_4}^{2-}$ and $NO_3{^-}$ concentrations are not necessarily proportional to the concentrations of their precursor emissions because the rates at which they form and their gas/particle partitioning may be controlled by factors (e.g., long range transportation) other than the concentration of the precursor gases.

포항지역에 대한 바람권역 분석 -Part I : 기상관측자료를 토대로 분석한 성긴 바람권역 분석- (Analysis of Wind Sector Division for Pohang Area - Part I : Coarse Division of Wind Sector for Pohang Area Using Meteorological Observation Data -)

  • 정종현;임헌호;이화운;장혁상;손병현
    • 한국환경과학회지
    • /
    • 제17권4호
    • /
    • pp.385-396
    • /
    • 2008
  • The air quality data is important for understanding and analyzing a surrounding influence. In that light, it is positively necessary for a propriety assessment to determine a location of the air quality monitoring sites. In this study, the climate analysis about temperature and wind, using the meteorological data in the Pohang, is conducted to do that. In the next stage, we distinguished the wind by east-west or north-south component, which has less correlation than temperature, analyzed and divided the wind sector. As the result, the wind circumstance of the Pohang is divided into major 5 wind sector; that is the urban area, the northeast coastal area, the east ocean and the west mountainous area. We think that an analysis on detailed wind sector by utilizing the numerical simulation is needed.

지하철역사의 공기질 감시 및 제어를 위한 유무선 네트워크의 성능평가에 관한 연구 (Performance Evaluation of Wireless and Wired Networks for Monitoring and Control of Indoor Air Quality(IAQ) in Subway Stations)

  • 최기흥
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.1-6
    • /
    • 2012
  • 복잡한 지하철 역사에서 공기질은 승객의 안전과 건강을 좌우하는 중요한 요소이다. $CO_2$, VOCs먼지, 미생물 등의 농도는 역사의 여러 지점에서뿐만 아니라 원격지점에서도 감시 및 제어가 가능해야 하기 때문에 유무선 네트워크를 사용한 웹기반 감시 및 제어가 필요하다. 가상디바이스 네트워크(VDN) 개념에 근거한 원격 무선센서 네트워크와 디바이스 네트워크(LonWorks)를 IP 네트워크에 연동시키면 매우 강력한 분산 감시 및 제어 성능을 제공한다. 본 연구에서는 지하철역사내 공기질 감시 및 제어를 위한 유무선 네트워크의 성능평가를 실시하였다. 특히 유무선 네트워크의 데이터 전송과 지연특성을 평가하고 승객의 안전과 건강을 위한 핵심요소를 확인하였다.

기상인자가 대기오염에 미치는 영향 (The Influence of Climatic Conditions on Air Pollution in Seoul)

  • 어수미;김광진;이규남
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.104-114
    • /
    • 1997
  • This study was carried out to research the influence of climatic conditions including wind direction, wind speed on air pollution in Seoul. The data were obtained from the 4 sites of air pollution monitoring stations in Seoul from '95 to '96, and analyzed statistically by SAS program. The results were as follows 1. The prevailing wind directions by season in each site were as follows Nangajwa-dong were showed SE in spring, fall, winter and WNW in summer. Ssangmun-dong were showed NW in spring, fall, winter and NNE in summer. Kuro-dong were showed SW in spring, summer, ENE in fall and NW in winter. Bangi-dong were showed WNW in four seeasons. 2. The concentrations of 5 kinds(SO$_2$, Dust, NO$_2$, CO, THC) of air pollutants were relatively low in west wind. In case of O$_3$ was opposite. 3. The concentrations of 5 kinds of air pollutants were increase with decreasing wind speeds. 4. The washing effects of air pollution by rain were significant. The concentrations of 5 kinds of air pollutants were high when the humidity were 61-80%, and low as it were 0-20%. In case of O$_3$ was opposite. 5. All of air pollutants concentrations but O$_3$ were high when the UV intensity level and temperature within the range of above zero were low level.

  • PDF

건설업 옥외작업장 근로자의 미세먼지 노출 실태 조사 (Exposure of Outdoor Workers to Particulate Matter in Construction Sites)

  • 김승원;이가현;피영규;양원호;하권철;박현희
    • 한국산업보건학회지
    • /
    • 제27권1호
    • /
    • pp.46-58
    • /
    • 2017
  • Objectives: Particulate matter (PM) at construction sites mostly originates from either construction activities or the atmospheric environment. This study was conducted to evaluate the exposure level to PM and the contribution ratio of atmosphere sources at construction sites. Methods: We reviewed literature and governmental systems related to PM exposure in occupational settings and summarized them. In the field evaluation, five construction sites and one golf course were selected: two from Gyeonggi-do Province and four from North Gyeongsang-do Province. For each site, personal samples from outdoor construction workers and area samples from the outdoor area around the construction site office were collected according to construction work types. PM concentrations reported from nearby National Ambient Air Monitoring Stations were recorded. Respirable dust concentrations, respirable silica concentrations, and several metal concentrations including Cd, Cr, Pb, and As were monitored over four months. In the end we suggested how to manage particulate matter exposure at construction sites. Results: There was little literature reporting on exposure levels of construction workers to PM. Respirable dust concentrations measured in Gyeonggi-do Province were higher than those measured in North Gyeongsang-do Province. The geometric means of respirable dust concentrations in personal samples and area samples were $37.89{\mu}g/m^3$ and $92.86{\mu}g/m^3$, respectively. The respirable dust concentrations were higher than the PM concentrations reported from nearby National Ambient Air Monitoring Station. The geometric means of respirable silica concentrations of personal samples and area samples were $1.3{\mu}g/m^3$ and $1.1{\mu}g/m^3$, respectively. All metal concentrations were lower than 10% of individual Korean occupational exposure limits. Conclusions: Assuming that personal samples consisted of ambient PM and dust originating from work activities and area samples only collected ambient PM, we concluded that the dust exposure of outdoor construction workers originated 40.8% from the atmosphere and 59.2% from construction activities. PM exposure at construction sites should be controlled by employers, as in the case of outdoor heat stress. The Korean government needs to consider setting an occupational exposure limit for respirable dust.

Summarize Water-soluble Ions of $PM_{2.5}$ in Northeastern Asia

  • Z. He;Seong Y. Ryu;Kim, Jeong E.;K. O. Ogunjobi;Kim, Young J.
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 추계학술대회 논문집
    • /
    • pp.400-401
    • /
    • 2003
  • Atmospheric fine aerosol particles play an important role in controlling a number of atmospheric processes, such as the deposition of different compounds, the optical properties etc. (Molnar et al., 1999). In this report, water-soluble species of PM$_{2.5}$ obtained from simultaneous measurements at four Asia sites (Beijng (39.56$^{\circ}$N, 116.17$^{\circ}$E), China; Gwangju (35.10$^{\circ}$N, 126.53$^{\circ}$E), South Korea; Kyoto (35.01$^{\circ}$N, 135.44$^{\circ}$E), Japan; and Ulan-Bator (47.55$^{\circ}$N, 106.52$^{\circ}$E), Mongolia) during the periods of 14-22 August, 30 October-06 November 2000, 14-21 January 2001, 23 July-02 August and 05-16 November 2002, within the framework of an APN (The Asia-Pacific Network for Global Change Research) project are reported. Ion components in 23 July-02 August 2002 were not obtained because of the technical problem of equipments.s.

  • PDF

배출량 분포에 따른 대구시 일산화탄소 측정망 위치의 적절성 평가 (Assessment of the Locations for Carbon Monoxide Monitoring Stations in Daegu according to Emission Distribution)

  • 김효정;조완근
    • Spatial Information Research
    • /
    • 제20권2호
    • /
    • pp.25-34
    • /
    • 2012
  • 대구지역은 주위가 산으로 둘러싸인 분지형 도시이기 때문에 대기 환경 쾌적성이 타 도시 보다 낮은 편이다. 따라서 본 연구에서는 대구지역 자동대기오염측정소의 위치를 일산화탄소(CO) 배출량 분포에 기초하여 CO를 체계적으로 관리하기위한 적합한 장소에 대해 조사하였다. 이를 위하여 현재 대구지역 CO 관리정책 수립에 기초자료를 제공하는 자동대기측정소의 위치 적절성에 대하여 평가하였다. 대구시 수치지도와 환경부에서 제공하는 CAPSS(대기정책지원시스템 ; Clean Air Policy Support System) 자료를 활용하여 배출량 지도를 작성하였다. 도로, 아파트, 공장, 소각장 4가지로 구분하여 배출량을 입력한 뒤 법정동별 평균 배출량을 산출하였다. CO 배출지역을 고 배출량 지역과 저 배출량 지역 10단계로 구분하고 현재 측정소가 어느 단계에 해당하는지 조사하였다. 결과적으로, 저 배출량 지역 보다는 CO 고 배출량 지역에 해당하는 측정소가 부족한 것으로 나타났다. 특히, 1999년부터 2007년까지 공통적으로 추가 설치가 필요하다고 나온 국우동 외 6곳에 CO 측정망이 설치된다면 보다 다양한 기초 자료의 제공으로 체계적인 CO 관리가 가능할 것으로 판단된다.

대구지역 공중이용시설의 실내 $\cdot$ 외 공기 중 기준성오염물질의 농도 (Concentrations of Criteria Pollutants in Indoor and Ambient Air of Public Facilities in Taegu Area)

  • 송희봉;민경섭;한개희;김종우;백성옥
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.429-439
    • /
    • 1996
  • A comprehensive air quality monitoring was carried out in this study to investigate the concentrations of criteria air pollutants in indoor and outdoor air of public facilities in Taegu area. Four different kinds of public facilities were seleced as sampling sites, which are underground stores, stations & terminals, general hospitals, and department stores. Each group of the public facilities was consisted of three different sampling sites. As a consequence, a total of 12 different sampling sites were surveyed throughout this study. Sampling was conducted simultaneously indoors, three times per day (in the morning, afternoon, and evening) and four times per year (spring, summer, fall, and winter) at each sampling site during the period of October 1994 to July 1995. A range of criteria pollutants were measured in order to obtain a broad profile of indoor and ambient air quality, including total suspended particles (TSP), carbon monoxide (CO), carbon dioxide ($CO_2$), formaldehyde (HCHO), sulfur dioxide ($SO_2$), and nitrogen dioxide ($NO_2$). In addition, temperature, relative humidity, and air current were measured on site together with those air pollutants. Results of this study indicated that the indoor levels of TSP, CO, $SO_2, and NO_2$ appeared to be generally higher in stations/terminals and underground stores than those in department stores and hospitals. However, HCHO and $CO_2$ were found to have higher levels in the department stores and hospitals than other places, indicating that the effects of indoor sources for these pollutants are significantly different from other combustion related pollutants such as TSP, CO, and $SO_2$. It was also found that there are marked seasonal and daily variations both in indoor and outdoor air quality. In general, combustion related pollutants such as CO, $SO_2$ and $NO_2$ showed a typical pattern of higher levels in winter than insummer, and also higher in the morning and/or in the evening than in the afternoon. However, the seasonal and daily patterns of HCHO appeared to be opposite to the combustion related pollutants, i.e., higher both in summer and in the afternoon, implying the effect of temperature on the volatilization from indoor sources of HCHO. Results of correlation analyses between indoor and outdoor air quality also indicated that the effects of outdoor sources on the indoor levels of TSP, $SO_2$, CO, and $NO_2$ and much significant, whilst no significant correlations between indoor and outdoor levels were found for HCHO and $CO_2$.

  • PDF

Comparison of Gene Mutation Frequency in $Tradescantia$ Stamen Hair Cells Detected after Chernobyl and Fukushima Nuclear Power Plant Accidents

  • Panek, Agnieszka;Miszczyk, Justyna;Kim, Jin-Kyu;Cebulska-Wasilewska, Antonina
    • 환경생물
    • /
    • 제29권4호
    • /
    • pp.373-378
    • /
    • 2011
  • Our aim was to investigate the genotoxicity of ambient air in the Krak$\acute{o}$w area after Fukushima Nuclear Power Plant (NPP) accident and compare with results from Chernobyl fallout. For the detection of ambient air genotoxicity the technique for screening gene mutation frequency in somatic cells of the $Tradescantia$ stamen hairs ($Trad$-SH assay) was used. Since 11th of March 2011 (Fukushima NPP accident), several pots containing at least 15 shoots of bioindicating plants were exposed to ambient air at 2 sites in the Krak$\acute{o}$w surrounding area, one in the city center, and about 100 pots in a control site (in the glasshouse of the Institute of Nuclear Physics) Continuous screening of mutations was performed. Progenies of 371,090 cells exposed were analyzed. Mutation frequency obtained in the first 10 days has shown a mean control level (GMF*100=$0.06{\pm}0.01$). At scoring period related to influence of a potential Fukushima fallout, a significant increase of gene mutation frequencies above the control level was observed at each site in the range, 0.10~0.33 depending on the location, (mean value for all sites GMF*100=$0.19{\pm}0.05$) that was associated with a strong expression of toxic effects. In the reported studies following the Chernobyl NPP accident monitoring $in$ $situ$ of the ambient air genotoxicity was performed in the period since April $29^{th}$ till June $3^{rd}$ 1986 also with Trad-SH bioindicator. In general, mutation frequency increases due to Chernobyl fallout(GMF*100=$0.43{\pm}0.02$) were corresponding to fluctuation of radioactivity in the air reported from physical measures, and to published reports about increase in chromosome aberration levels. Although, recent data obtained from monitoring of the ambient air quality in the Krak$\acute{o}$w and surroundings are lower when compared to results reported after Chernobyl NPP accident, though results express a significant increase above the control level and also are corresponding with increased air radioactivity reported from physical measurements. Statistically significant in comparison to control increase in gene mutation rates and more prolonged than that after Chernobyl fallout increase of GMF was observed during the period following the Fukushima NPP failure.