• 제목/요약/키워드: Air leakage rate

검색결과 141건 처리시간 0.025초

회전식 폐열회수 환기유닛의 공기누설 및 전열특성에 관한 실험적 연구 (An Experimental Study on Air Leakage and Heat Transfer Characteristics of a Rotary-type Heat Recovery Ventilator)

  • 한화택;김민규
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1197-1203
    • /
    • 2004
  • This study investigates the air leakage and heat transfer characteristics of a rotary-type air-to-air heat exchanger with a fiber polyester matrix. The leakage airflow rate is measured using a tracer gas method for various ventilation rates and rotational speeds of the matrix wheel. A correlation equation for air leakage is obtained by combining the pressure leakage and the carryover leakage. The pressure leakage is observed to be a function of ventilation airflow rate only, and the carryover leakage is found to be a linear function of rotational speed. The real efficiency of the heat exchanger can be obtained from its apparent efficiencies by taking into account the air leakage ratio. As the ventilation rate increases, the heat recovery efficiency decreases. As the rotational speed of the matrix increases, the efficiency increases initially but reaches a constant value for the rotational speeds over 10 rpm.

An Experimental Study on Air Leakage and Heat Transfer Characteristics of a Rotary-type Heat Recovery Ventilator

  • Han, Hwa-Taik;Kim, Min-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권2호
    • /
    • pp.83-88
    • /
    • 2005
  • This study investigates the air leakage and heat transfer characteristics of a commercially available rotary-type air-to-air heat exchanger with a fiber polyester matrix. Crossover leakage between the exhaust and supply air is measured using a tracer gas method for various ventilation rates and rotational speeds of the wheel. A correlation equation for the leakage is obtained by summing up pressure leakage and carryover leakage. The pressure leakage is observed to be a function of ventilation rate only, and the carryover leakage is found to be a linear function of wheel speed. The real efficiency of the heat exchanger can be obtained from its apparent efficiency by taking into account the leakage ratio. The heat recovery efficiency decreases, as the ventilation rate increases. As the wheel speed increases, however, the efficiency increases initially but reaches a constant value for the speeds over 10rpm.

제습로터의 공기누설모델 개발 및 성능 특성에 관한 실험적 연구 (Experimental Study on Development of Air Leakage Model and Performance Characteristics of a Desiccant Rotor)

  • 강병하;피창헌;장영수
    • 대한기계학회논문집B
    • /
    • 제36권1호
    • /
    • pp.37-45
    • /
    • 2012
  • 제습로터에서 발생하는 공기누설은 로터와 브러쉬 형태의 누설방지모 틈새의 양단 사이 차압에 의해 발생하는 압력누설이 지배적이며, 실험을 통해 압력누설특성을 파악하였다. 그 결과로, 압력누설량을 로터와 누설방지모의 틈새면적과 차압의 함수로 나타내었다. 위의 상관식을 바탕으로 제습로터의 공기누설모델을 개발하였으며, 실험을 통해 측정된 값과 위 모델을 바탕으로 계산된 값을 비교함으로써 공기누설모델을 검증하였다. 그리고 풍량에 따른 제습로터의 성능실험을 수행하였으며, 공기누설모델을 적용한 성능 분석을 통하여 실질적인 제습량과 공기누설량을 확인 하였다. 또한 동일한 제습로터가 적용된 제습냉방시스템을 고려하여 차압변화에 따른 공기누설의 영향을 공기누설모델을 이용하여 고찰하였다.

국내·외 누설률에 관한 기준 분석을 통한 국내 연기제어 기준 개선에 관한 연구 (A Study on the Improvement of Domestic Smoke Control Standards through Analysis the Standards about Air Leakage Rate of Domestic and Abroad)

  • 김혜원;한지우;이병흔;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.61-62
    • /
    • 2018
  • On this Study, it conducts the Standards investigation about air leakage of Buildings for performance improvement of Smoke control in Fire. In domestic standards, it is incomplete the Criteria standards of air leakage. Therefore it is considered that won't limit the smoke spread due to stack effect. But in the case of the United States, it conducts the Hot smoke air-Leakage test and it consider that can prevent the Smoke Spread in Compartment.

  • PDF

자연급기구내 플리머필터 설치 시 외기 침기량 분석에 관한 연구 (A study on performance of outdoor air flow rate through viovent for hybrid ventilation equipment)

  • 이성환;최종악
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1337-1342
    • /
    • 2009
  • This test was progressed in the test house of KICT as sectional research of Center for Sustainable Housing. It included a ventilation rate of hybrid ventilation equipment, temperature, and gas test using the SF-6. The purpose of this test is to demonstrate the performance of viovent by estimating an outdoor air flow rate through viovent which the flimmer filter is installed and decide the leakage after operating the constant airflow fan within a house. First, the outdoor airflow rate through viovent measured $130\;m^3/h$ more than a legal required ventilation rate, $104\;m^3/h$. And then it sufficiently satisfy a legal standard, 0.7 air change/h. Secondly, the result of this test exposes that the leakage in the residence is about $20{\sim}25%$. Especially, the outdoor air flowing through the gate occupies 50% of the total leakage.

  • PDF

Experimental investigations on the resistance performance of a high-speed partial air cushion supported catamaran

  • Yang, Jinglei;Lin, Zhuang;Li, Ping;Guo, Zhiqun;Sun, Hanbing;Yang, Dongmei
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.38-47
    • /
    • 2020
  • The partial air cushion supported catamaran (PACSCAT) is a novel Surface Effect Ship (SES) and possesses distinctive resistance performance due to the presence of planing bottom. In this paper, the design of PACSCAT and air cushion system are described in detail. Model tests were carried out for Froude numbers ranging from 0.1 to 1.11, the focus is on the influence of air cushion system on resistance characteristics. Drag-reducing effect of air cushion system was proved by means of contrast tests in cuhionborne and non-cushionborne mode. Wave-making characteristics reflect that the PACSCAT would eventually enter planing regime, in which the air could just escape under the seals and the hull body could operate in a steady state. To acquire different air cushion pressure, air flow rate and leakage height were adjusted during tests. Experimental results show that the resistance performance in planing regime would decrease evidently as the increased air flow rate, however, the scheme with medium leakage height presents the best resistance performance in the hump region.

공압실린더의 누설유량 계측방법에 관한 연구 (A Study on the Measurement Method of Leakage Flow-rate for Pneumatic Cylinder)

  • 장지성;지상원;정지현;강보식
    • 유공압시스템학회논문집
    • /
    • 제3권1호
    • /
    • pp.15-19
    • /
    • 2006
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measure from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing steel wool into it. Therefore, wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

스크롤 압축기 누설 모델의 CFD 해와의 비교 연구 (A Comparative Study of Leakage Flow Models for Scroll Compressors with CFD Solutions)

  • 강동진;홍석준;전현주
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.843-851
    • /
    • 2003
  • The present paper studies the leakage flow model used in the performance prediction of a scroll compressor. Two leakage flow models, isentropic and Fanno flow model, are studied in detail. Their predictions are also compared with CFD solutions to check the validity as a leakage flow model. Comparison with CFD solutions shows that the isentropic flow model predicts excessive leakage flow rate, while the Fanno flow model shows acceptable agreement with CFD solutions. The excessive leakage flow rate by isentropic flow model results in under-prediction of the overall performance of a scroll compressor.

공기압실린더의 누설유량 계측에 관한 연구 (A Study on the Measurement Method of Leakage for Pneumatic Cylinder)

  • 장지성;지상원
    • 동력기계공학회지
    • /
    • 제11권4호
    • /
    • pp.98-102
    • /
    • 2007
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measured from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing the steel wool into it. Therefore, a wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

복공식 지하 압축공기에너지 저장공동 기밀시스템 설계변수의 민감도 해석 (Sensitivity Analysis of Design Parameters of Air Tightness in Underground Lined Rock Cavern (LRC) for Compressed Air Energy Storage (CAES))

  • 김형목;;류동우;선우춘;송원경
    • 터널과지하공간
    • /
    • 제21권4호
    • /
    • pp.287-296
    • /
    • 2011
  • 본 연구에서는 압축공기에너지 지하저장을 위한 복공식 암반공동의 기밀성능을 평가할 목적으로 다상유체 열유동 해석을 수행하였다. 기밀성능은 저장공동으로부터 누출되는 공기질량으로 평가하였으며, 저장공동 내부에 콘크리트 라이닝 기밀시스템을 설치하고 저장공동은 비교적 천심도인 지하 100m 심도에 위치하는 것으로 가정하였다. 저장공동 내 질량수지분석 결과, 콘크리트 라이닝 및 주변 암반의 투과계수가 누기량 및 저장공동의 장기적 기밀성능에 미치는 영향이 큰 것으로 파악되었으며 콘크리트 라이닝의 투과계수가 $1.0{\times}10^{-18}\;m^2$이하 일 경우, 저장공동 운영압력이 5 MPa에서 8 MPa 사이일 때 누기량은 1%이하 인 것으로 계산되었다. 또한, 콘크리트 라이닝의 초기포화도에 따른 공기누출량 계산결과, 라이닝 수분포화도를 증가시킬수록 누기량은 감소하고 저장공동 기밀성능이 향상됨을 확인하였다.