• Title/Summary/Keyword: Air hole

Search Result 435, Processing Time 0.029 seconds

Novel design of higly-birefringet fiber with elliptical hollow (타원형 공동을 갖는 새로운 고복굴절 광섬유의 설계)

  • Hwang, In-Gak;Lee, Yong-Hui;O, Gyeong-Hwan;Payne, David N.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2004.02a
    • /
    • pp.370-371
    • /
    • 2004
  • We propose and analyze a novel high-birefringence fiber incorporating an elliptical air hole in the core. Compared to solid elliptical core fibers, several times higher birefringence is achieved with a sub-wavelength-sized hole.

  • PDF

Ventilation Hole Optimum Design of Smart Unit Load Container for Storage and Distribution Agricultural Products by Theoretical Heat Flow Analysis (이론적 열유동 해석을 이용한 농산물 저장 및 유통 스마트 유닛로드 컨테이너의 통기공 최적화 설계)

  • Dong-Soo, Choi;Yong-Hoon, Kim;Jin-SE, Kim;Chun-Wan, Park;Hyun-Mo, Jung;Ghi-Seok, Kim;Jong-Min, Park
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.3
    • /
    • pp.211-215
    • /
    • 2022
  • Air distribution occupies an important position in the smart unit load container design process for agricultural products. Inner air may be uncomfortable because of its temperature, speed, direction, and volume flow rate. It doesn't matter how efficient the ventilation equipment is if the air is not distributed well. The main aim of this study was to design the inlet and outlet fan locations of smart unit load container for agricultural products. A numerical study was performed on the effects of the location of inlet air and outlet air in relation to the container cooling sources on air distribution and thermal comfort. A concept of combining inner container cooling sources with the exhaust outlet was employed in this investigation. Also, in this research, the developed CFD (Computational Fluid Dynamics) models were thoroughly validated. This system was adopted for use in container spaces, where the exhaust outlet was located. In this study, the location of the inlet was derived through CFD for a container with a size of 1,100×1,100×1,700 mm, and it was derived that the inlet was located at the center of the lower part of the container for efficient air flow. It was efficient to position the outlet through the air inlet in the center of the lower part of the container at the top of the same side.

Experimental and Computational Study on Separation Control Performance of Synthetic Jets with Circular Exit

  • Kim, Minhee;Lee, Byunghyun;Lee, Junhee;Kim, Chongam
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.3
    • /
    • pp.296-314
    • /
    • 2016
  • This paper presents experimental and computational investigations of synthetic jets with a circular exit for improving flow control performance. First, the flow feature and vortex structure of a multiple serial circular exit were numerically analyzed from the view point of flow control effect under a cross flow condition. In order to improve separation control performance, experimental and numerical studies were conducted according to several key parameters, such as hole diameter, hole gap, the number of hole, jet array, and phase difference. Experiments were carried out in a quiescent condition and a forced separated flow condition using piezoelectrically driven synthetic jets. Jet characteristics were compared by measuring velocity profiles and pressure distributions. The interaction of synthetic jets with a freestream was examined by analyzing vortical structure characteristics. For separation control performance, separated flow over an airfoil at high angles of attack was employed and the flow control performance of the proposed synthetic jet was verified by measuring aerodynamic coefficient. The circular exit with a suitable hole parameter provides stable and persistent jet vortices that do beneficially affect separation control. This demonstrates the flow control performance of circular exit array could be remarkably improved by applying a set of suitable hole parameters.

Femtosecond Pulsed Laser Ablation of OLED Shadow Mask Invar Alloy (펨토초 레이저를 이용한 OLED 용 Shadow Mask Invar 합금의 어블레이션)

  • Chung, Il-Young;Kang, Kyung-Ho;Kim, Jae-Do;Sohn, Ik-Bu;Noh, Young-Chul;Lee, Jong-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.12
    • /
    • pp.50-56
    • /
    • 2007
  • Femtosecond laser ablation of the Invar alloy and hole drilling for a shadow mask are studied. We used a regenerative amplified Ti-sapphire laser with a 1kHz repetition rate, 184fs pulse duration and 785nm wavelength. Femtosecond laser pulse was irradiated on the Invar alloy with air blowing at the condition of various laser peak power. An ablation characteristic of the Invar alloy was appeared non-linear at $125J/cm^2$ of energy fluence. For the application to a shadow mask, the hole drilling of the Invar alloy with the cross section of a trapezoidal shape was investigated. The ablated micro-holes were characterized using an atomic force microscopy(AFM). The optimal condition of hole pattern f3r a shadow mask was $4\;{\mu}m$ z-axis feed rate, 0.2mm/s circular velocity, $26.4{\mu}J$ laser peak power. With the optimal processing condition, the fine circular hole shape without burr and thermal damage was achieved. Using the femtoseocond laser system, it demonstrates excellent tool for the Invar alloy micro-hole drilling without heat effects and poor edge.

Topology Optimization of Muffler Hole using Genetic Algorithm (유전자 알고리즘을 이용한 머플러 구멍 위상최적설계)

  • Wang, Semyung;Dikec, Altay;Hwang, Insoo;Kwon, Byoungha
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1205-1205
    • /
    • 2003
  • Rotary compressors are one of the most important parts of air-conditioners in the industry This device usually has noise problems during the circulation process of the refrigerant and muffler is used for the noise reduction. The acoustic performance of the muffler depends on its shape and its hole locations on the upper surface. Therefore finding the optimum location of the muffler holes is a topic of increasing importance in the compressor industry. In this research the optimization of the muffler hole locations and the importance of the resonator cavity on the lower surface of the muffler in acoustic point of view is studied. At first, the topology optimization for the 2 hole muffler is performed based on a model without resonator cavity by using genetic algorithm. The 2 hole muffler's acoustic analysis and experiment results are matching, however, the optimized model's results are not. By adding the resonator cavity and also by changing the cavity shape, the acoustic analysis and experiment result comparison is Performed for different cavity shapes. The topology optimization of the revised model with cavity is carried out for noise reduction. Finally, the optimized design is produced and tested for validation.

  • PDF

The Vortical Flow Field of Delta Wing with Leading Edge Extension

  • Lee, Ki-Young;Sohn, Myong-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.914-924
    • /
    • 2003
  • The interaction and breakdown of vortices over the Leading Edge Extension (LEX) - Delta wing configuration has been investigated through wing-surface pressure measurements, the off-surface flow visualization, and 5-hole probe measurements of the wing wake section. The description focused on analyzing the interaction and the breakdown of vortices depending on the angle of attack and the sideslip angle. The Effect of angle of attack and sideslip angle on the aerodynamic load characteristics of the model is also presented. The sideslip angle was found to be a very influential parameter of the vortex flow over the LEX-delta wing configuration. The introduction of LEX vortex stabilized the vortex flow, and delayed the vortex breakdown up to a higher angle of attack. The vortex interaction and breakdown was promoted on the windward side, whereas it was suppressed on the leeward side.

Investigation of the HV Ionic Wind Generator and the Control of Corona Discharge for Air-flow Formation (기류형성을 위한 고전압 이온풍 발생장치와 코로나 제어기술에 관한 기초적 연구)

  • Lee, B.H.;Eom, J.H.;Kang, S.M.;Chang, K.C.;Ahn, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1707-1709
    • /
    • 2002
  • Ionic wind may be produced by DC corona discharges. In this work, the electrical effect has studied to evaluate applicability in fields of electrostatic cooling, ozone generation, electrostatic precipitation, heat transfer, air flow modification, and etc. The ionic wind velocity was measured as a function of the distance of pin to plate and the diameter of punched hole. The pin to punched-plate electrode generates airflow from pin to plate and the flow direction is controlled by the hole size of punched-plate, input voltage and distance between two electrodes. As a consequence, the ionic wind velocity is nearly proportional to the applied voltages and ranges from 1 to 3 m/sec.

  • PDF

Study for the Cooling Performance Improvement of a Mini Bus (소형버스 냉각성능 향상 연구(I))

  • Lyu, Myung-Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.10-15
    • /
    • 2005
  • This study was initiated to evaluate the cooling performance of CAC (charged air cooler) and radiator in the engine room of a mini bus. So we had firstly to predict the mass flow rate coming from radiator grille and front bum per opening using computational fluid dynamics (CFD) simulation based on 3D configuration. And simulations were carried out for different cooling module layout and bum per opening hole size on sam e vehicle operating condition. Simulation results show that CAC cooling performance at reverse protecting plate-applying model was much efficient than that of the bum per opening hole size-increasing model in IMTD point of view. Part of the CFD simulation results was com pared to with experimental data. It was confirm ed that the CFD approach using STAR-CD based on pursuing no-com promise solution could provide design engineers with useful design information in the early design stage of vehicle development.

Performance Analysis of the Swash Plate Type Compressor using CO2 Refrigerant (CO2용 사판식 압축기 성능 해석)

  • Lee, Geon-Ho;Park, Ik-Seo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.564-569
    • /
    • 2005
  • Recently, from the viewpoint of global wanning, natural gas CO2 is considered as a main refrigerant for hot water system. The characteristics of CO2 is not toxic, not flammable, high pressure, and high refrigerating capacity. Also it is widely available as a byproduct of industrial processes. This paper describes the performance analysis program of the swash plate type compressor using CO2 refrigerant. Estimates of the refrigerant flow rate, compression work, discharge temperature and volumetric, compressor efficiencies of the CO2 swash plate type compressor are obtained from the various design parameter such as the inclination angle of the swash plate, discharge hole area and suction hole area.

  • PDF

Performance of a Reciprocating Compressor Equipped with Auxiliary Port (보조 흡입구가 장착된 왕복동 압축기의 성능 분석)

  • Lee, Yong-Ho;Kim, Hyun-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.637-644
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.