방향 탐지용 대공 근접 신관센서의 BPSK 송수신기 설계에 관한 연구 (Design of a BPSK Transceiver for the Direction Finding Proximity Fuze Sensor for Anti-air missiles)

  • 최재현;이석우;염경환
    • 한국군사과학기술학회지
    • /
    • 제16권1호
    • /
    • pp.81-88
    • /
    • 2013
  • This paper describes the fundamentals, design, realization and test results of a BPSK(Bi Phase Shift Keying) transceiver for the direction finding proximity fuze sensor for anti-aircrafts or air missiles. The BPSK transceiver for the direction finding fuze sensor has been designed to detect a moving target by Doppler signal processing with the code correlation method and to distinguish direction by comparing received powers of each Doppler signal from adjacent three receiving antennas. The electrical and ESS(Environmental Stress Screening) tests of the BPSK transceiver showed satisfactory results and target detection and direction finding performances proved to be successful through dynamic operation tests by 155 mm gun firing.

지하철역사내 측정위치별 PM-10 및 중금속 농도특성에 관한 연구 (A study of PM-10 and Heavy Metal characteristics in the air at the each site of a subway station.)

  • 장정욱;조장제;최우건;박덕신;정우성;김태오
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.389-394
    • /
    • 2003
  • Subway has been used one of major public transportations because of overpopulation and heavy traffic problems in the metropolitan areas. So, the air pollution has been serious. In this study, continuous date of PM-10 (particles with aerodynamic diameter < $10{\mu}m$) and heavy metal concentration measurements for winter, spring and summer. These measurements have been carried out in the outdoor, concourse, platform, tunnel. The study results showed that the average seasonally concentration of PM-10 particles were $141.57{\mu}g/m^3$ in winter. $129.34{\mu}g/m^3$ in spring and $122.73{\mu}g/m^3$. The average concentration of PM-l0 particles at indoor higher than outdoor. The concentration of Fe, Cu, showed the largest peak concentrations during the respective season.

  • PDF

Penicillium mexicanum: An Unrecorded Fungal Species Isolated from Air Samples Collected in Korea

  • Jung-Min Lee;Jae-Eui Cha;Young-Sil Yoon;Ahn-Heum Eom
    • 한국균학회지
    • /
    • 제51권2호
    • /
    • pp.127-133
    • /
    • 2023
  • We report the first discovery of Penicillium mexicanum in Korea. Fungal strains were isolated from air samples collected in Taean-gun, Chungcheongnam-do, Korea. The strain was identified based on its morphological characteristics, as well as molecular phylogenetic analysis of the internal transcribed spacer (ITS), β-tubulin (BenA), and calmodulin (CaM) regions. This strain exhibited a high sequence similarity to the reference sequences of P. mexicanum. These findings enhance our understanding of fungal biodiversity in Korea and underscore the importance of continuous monitoring of fungal species.

열처리조건에 따른 Bi-2212 라운드형 선재의 특성 (Characteristics of Bi2212 Round-wire Depending on Heat Treatment Condition)

  • 이남일;장건익;오상수;하동우;김상철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권3호
    • /
    • pp.1-4
    • /
    • 2006
  • The characteristics of Bi2212 round wire was systematically studied depending on different heat treatment conditions. Initial wire was drawn after routine PIT (Powder In Tube) process. The wire was divided into 3 pieces with 10 cm in length and 2.5 mm in diameter. 3 wires were pre-heat treated separately by different heat treatment schedules, heated in air and nitrogen atmosphere and centrifugally melted. Pre-heated wires were annealed at $845^{\circ}C$ for 40 hours in oxygen atmosphere. SEM results indicate that all pre-heated wires showed highly oriented microstructure. However the wire by centrifugally melted process showed higher density and better electric properties as compared with 2 other wires pre-heated in air and nitrogen atmosphere. The critical current of a centrifugally melted wire was about 18 A in 77 K.

질소흡착법을 사용한 고온 가열 시멘트의 세공구조 측정 (Measurement of the construction structure of hot-heated cement using nitrogen adsorption method)

  • 김민혁;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.140-141
    • /
    • 2020
  • Concrete has a lower thermal conductivity or thermal diffusion coefficient compared to other building materials, so it is widely used as fireproof compartment material or refractory material for structures. However, in the event of thermal damage such as fire, cement curing agents and aggregates act differently, resulting in heat generation or deterioration of tissue due to dehydration, resulting in deterioration of physical properties and fire resistance. Therefore, in this study, the processing structure of cement paste is measured through nitrogen absorption method. The test specimen is a cement paste of 40% W/C and is set at 1000 ℃ under heating temperature conditions. As the temperature rose, the micro-pore mass below was reduced based on about 0.01 감소m, but the air gap above that was increased.Thus, in the range of pores measured in nitrogen adsorption, the air mass tended to decrease under high temperature conditions.

  • PDF

한국과 중국의 콘크리트용 화학 혼화제 품질 규정 비교 (Comparison of Quality Standards of Chemical Admixtures for Concrete between Korea and China)

  • 후윈야오;임군수;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.97-98
    • /
    • 2023
  • In this study, comparison of the quality standard of chemical admixtures between Korea and China is conducted. It is classified into three types of water reducing agents: standard, delayed, and accelerated according to the sensitivity and strength improvement of the sensitivity and strength of the agent. However, Chinese standards classify reducing agents only as standard, high efficiency, and high performance, and do not add AE agents into water reducing agent. On the other hand, that of Korea has a classification regulation for reducing agents added with AE agents.

  • PDF

음향 Air-Gap 공격의 최신 동향과 실용성에 대한 연구 (A Survey on Acoustic Air-Gap Attacks)

  • 조건희;이연준
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2023년도 추계학술발표대회
    • /
    • pp.218-219
    • /
    • 2023
  • 본 논문은 에어갭 (물리적 분리된 네트워크 환경) 공격 벡터 중 음향 신호를 중점적으로 다루며, 음향 신호 공격 벡터에 대한 연구 동향과 실제 사용 가능성을 조사한다. 연구 결과, 에어갭 공격은 높은 수준의 스텔스와 무결성이 필요하며, 환경적 제약과 사회적 요소도 고려해야 한다. 또한, 실제 공격에는 다단계 프로세스와 통합된 모듈이 필요하며, 이러한 조건을 충족하는 공격은 제한적일 것으로 보인다. 제한적인 공격이 실제로 가능하더라도, 공격 성공 시 파급력이 크기 때문에, 본 논문은 에어갭 보안에 대한 중요성을 강조하며, 공격을 무력화 할 수 있는 높은 보안수준을 유지하기 위한 연구와 대응책이 필요함을 강조한다.

바람길 활용을 위한 정맥의 찬공기 관리 방안 - 낙남정맥을 사례로 - (Management Strategies of Local Cold Air in Jeongmaek for utilizing urban Ventilation Corridor - A Case Study of the Nak-nam Jeongmaek -)

  • 엄정희
    • 한국지리정보학회지
    • /
    • 제22권1호
    • /
    • pp.154-167
    • /
    • 2019
  • 기후변화에 따른 각종 환경문제가 발생하는 가운데, 도시에서는 폭염, 열대야와 같은 도시 열환경 문제가 심각해지고 있다. 한국은 찬공기 생성에 유리한 산림지역이 국토면적의 약 63%을 차지하고 있으며, 주요 산줄기인 정맥은 도시지역과 밀접하게 위치해 있기 때문에 찬공기를 활용하는 것은 도시 열환경 완화에 매우 효과적인 방안이 될 수 있다. 본 연구에서는 낙남정맥을 대상으로 정맥에 위치한 도시들의 바람길 활용 방안을 마련하기 위해 정맥의 찬공기 특성을 알아보고, 이를 바탕으로 낙남정맥의 찬공기 관리방안을 제안하였다. 또한, 낙남정맥에 위치한 진주시와 산청군을 대상으로 상세분석을 수행하여, 정맥에서 생성된 찬공기 흐름이 인근 도시 지역에 미치는 영향을 분석하고 이를 바탕으로 도시지역에서 찬공기를 활용하기 위한 관리방안을 제시하였다. 찬공기 특성 분석을 위해 독일에서 개발된 모형인 KALM(Kaltluftabflussmodell)을 활용하였으며, 야간 6시간 동안 생성되는 찬공기 흐름 및 찬공기층 높이를 파악하였다. 분석 결과, 시간이 경과함에 따라 정맥에서 생성된 찬공기 흐름이 뚜렷해지고, 찬공기층의 높이는 증가하였다. 찬공기 분석 결과를 바탕으로, 찬공기 흐름을 유지 및 확대할 수 있는 관리방안을 제안하였다. 예를 들어, 찬공기 생성이 활발한 산림지역 일대를 '찬공기 보전지역'으로 지정하고, 원활한 찬공기 흐름을 위해 관리가 필요한 지역을 '찬공기 관리지역'으로 지정하여 전략을 제시하였다. 본 연구의 결과는 낙남정맥에 위치한 도시지역의 쾌적한 열환경 조성을 위한 바람길 활용방안의 일환으로 낙남정맥의 체계적인 관리계획을 수립하는데 기초자료로 활용될 수 있을 것으로 기대한다.

바이오디젤의 난방유로서의 연료특성 (Fuel Qualities of Different Biodiesels in the Gun Type Burner)

  • 김영중;강연구;강금춘;유영선
    • Journal of Biosystems Engineering
    • /
    • 제33권2호
    • /
    • pp.124-129
    • /
    • 2008
  • In this study, fuel qualities including kinematic viscosity and pour point in the various temperature, calorific value and combustion characteristics of two biodiesels based on the soybean and waste oil blended with light oil were investigated and discussed in order to figure out to confirm fuel compatibility taking the place of light oil in the hot air heater or boiler. As biodiesel content ratio increased calorific value of biodiesel decreased, and the difference was 13% between 100%-biodiesel and light oil. In general, pour points of the biodiesels were higher than light oil, and as biodiesel content ratio increased pour point increased. About 15 cSt was the pour point of biodiesels and light oil, which occurred at 3 to $4^{\circ}C$ in the biodiesels and $-25^{\circ}C$ in the light oil. Flame dimensions of biodiesels and light oil were almost same at the same combustion condition in the burner of the hot air heater. CO concentrations in the exhaustion gas were far lower than those of the light oil. Though pour point of biodiesel is a little inferior to light oil, still biodiesel can be an alternative fuel substituting for light oil in combustion system without much modifying the current oil combustion mechanism.

A Study on the Stable Sensorless Control of BLDC Motor Inside Auxiliary Air Compressor

  • Kim, In-Gun;Hong, Hyun-Seok;Go, Sung-Chul;Oh, Ye-Jun;Joo, Kyoung-Jin;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.466-471
    • /
    • 2017
  • Pantograph must be correctly attached to catenary to continuously supply stable power to railway vehicle, and the device used here is Auxiliary Air Compressor (ACM). The existing ACM used the DC motor that included commutator and brush. Since maintenance and repair by mechanical friction are essential for the DC motor, BLDC motor studies have been conducted to improve this. A three-phase BLDC motor does $120^{\circ}$ two-phase commutation through hall sensors in general. However, since hall sensor is vulnerable to heat and can run only when all three sensors work normally, sensorless control method has been studied to solve this. Using back EMF Zero Crossing Point (ZCP) detection method, this paper will introduce a stable switching sensing method that has a non-commutation area in a low speed zone.