발열시스템 열적 성능의 정밀측정에 관한 연구 (A Study on the Precise Measurement of the Performance in the Heating System)

  • 최창용;김홍건
    • 한국공작기계학회논문집
    • /
    • 제11권6호
    • /
    • pp.60-67
    • /
    • 2002
  • A precise measurement of field test was performed to estimate the thermal performance of the forced convection electric air heater by experiment. Air temperature, flow rate and electrical power input were measured with the related measurement sensors, and acquisition methods for the measured data were studied to estimate the thermal performance of the tested air heater effectively. To determine the mean air temperature at the flow cross-section, measuring positions were chosen by considering the flow velocity profile and the equally divided cross-sectional area. From the experimental results, thermal efficiency was obtained accurately as an indication of the tested heating system performance.

공기청정기 시험기의 센서신호 오차가 공기청정기 성능 평가에 미치는 영향 (Effects of Sensor Errors in Air Cleaner Testing on the Cleaner Performance Estimation)

  • 이천환;김민영;이수민
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.77-82
    • /
    • 2023
  • The fuel cell in fuel cell electric vehicle utilizes oxygen in the atmosphere, which requires the use of an air cleaner system to minimize the intake of harmful pollutants. To estimate the performance of the air cleaner system, the pressure drop between the filter inlet and outlet is used under the rated air flow condition. In this study, the effect of sensor error in this air cleaner testing is experimentally carried out. It is found that the errors of the temperature sensor does not significantly affect the estimation of pressure drop. However, in the case of the pressure sensor, 5% sensor error results in the error of pressure drop estimation by 3%. Therefore, it is recommended that the measurement accuracy of the pressure sensor mounted in test system should be maintained at less than 5%.

칼만와류식 공기유량센서의 와안정판이 후류유동장과 와유출주파수에 미치는 영향 (The Effect on Wake Flow and Vortex Shedding Frequency by Vortex Stabilizer in Karman Vortex Type Air Flow Sensor)

  • 임성원;류병남;이종춘;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권4호
    • /
    • pp.846-856
    • /
    • 2001
  • An experimental study has been made to investigate the effect on wake flow and vortex shedding frequency by vortex stabilizer in Karman vortex type air flow sensor. The conditions investigated include 3 types of shapes and 3 types of separation distances of the vortex stabilizer. The phase averaged technique and smoke-wire flow visualization method are used to understand the detail information. The rolling up position of shear layer is fixed by the influence of the vortex stabilizer. Especially, the convex type vortex stabilizer has shown the more stable repeatability and linearity regarding the vortex shedding frequency compared to the other types.

  • PDF

엔진 및 차량냉각계의 냉각수유량 측정실험 및 계산방법에 관한 연구 (A Study of the Experiment and the Calculation Method on the Coolant Flow Rate of Engine and Vehicle Cooling System)

  • 오창석;유택용;이은현;최재권
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the prediction method of coolant flow rates has been developed and applied to an engine and vehicle cooling system. The flow rate passing through each component of the system is very important parameter to evaluate the heat transfer process form the combustion gas to the coolant and the heat rejection process form the radiator /heater to the ambient air. However, the present study reveals that the measurement using the flowmeter fails to give practical flow rates due to its additive resistance. In contrast, the present method which uses the parallel and serial relationship of flow resistance proved to be a good tool to predict the real flow rates. It can be also used to design the cooling system in the incipient stage of engine/vehicle development . The procedure was coded to the computer program so as to use it flexibly and, in the future, to expand it into an independent design tool of the whole cooling system including the heat release and rejection.

  • PDF

유압관로에서 원통형 초크의 비정상 유동의 주파수 특성에 관한 연구 (Frequency Characteristics of Unsteady Flow of Cylindrical Choke in a Hydraulic Pipe)

  • 박선종;유영태;위광환
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.421-434
    • /
    • 1995
  • A new instantaneous flowmeter for hydraulics by means or cylindrical chokes is developed. In this method the instantaneous flowrate through chokes is predicted in real time from measurement of pressure difference on both sides of cylindrical choke. The experimental study for the flowrate of pulsating flow in a pipe is carried out to measure differential pressure drop by using a strain gauge pressure transducer with data acquisition and processing system. A pulsating flow is verified by a visualization method. In the present study, the flow characteristic variables of laminar pulsating flow are investigated analytically and experimentally in a circular pipe. Characteristic parameters of ratio of inertia term to pressure term($\phi_{t.1}$) and ratio of viscous term to pressure term($\phi_{z.1}$) are introduced to describe the flow pattern of laminar pulsating flow.

  • PDF

2중판 오리피스를 이용한 기액 2상유량계의 개발 (Development of a 9as-liquid two-phase flowmeter using double orifice plates)

  • 이상천;이상무;남상철
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.619-629
    • /
    • 1998
  • An experimental work was conducted to investigate a feasibility of simultaneous measurement of gas-liquid two-phase flowrates with double orifice plates using air and water. The tests were carried out under the atmospheric pressure and at the ambient temperature using two different tube sizes. Qualities of an air-water flow in the present study have values less than 0.1 and thus the mixed flow showed bubbly, plug, slug flow regimes. The probability density function (PDF) and the power spectral density function (PSDF) of the instantaneous pressure drop traces for the flow regimes were obtained. It is found that some distinctive features exist in the distribution of these functions, depending upon the two-phase flow pattern. The time-averaged value of the instantaneous pressure drop increases with increasing gas and liquid flowrates, showing a single-valued function for the total mass flowrate and the quality. It is also found that the two-phase discharge coefficient exhibits a consistent trend for variation of dimensionless parameters such as the superficial velocity ratio and the gas Reynolds number. The results indicate that simultaneous measurement of two-phase flowrate may be possible based upon a statistical analysis of the instantaneous pressure drop curves monitored using double orifice plates.

  • PDF

공압식 박동형 심실보조장치의 공압관 내 압력 측정을 통한 박출량 추정 (Estimation of Ventricular Assist Device Outflow with the Pressures in Air Pressure Line)

  • 김영일;허균;강성민;최성욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.119-124
    • /
    • 2014
  • A Ventricular assist device (VAD) is one of the most efficient treatments to raise the survivability of the end stage heart failure patient. However, some of LVAD patients have died for the failures and improper control of LVAD. To detect critical dangers in LVAD, the monitoring methods of LVAD outflow have been requested, because it can be affected by patient's hemodynamic states and abnormal conditions of LVAD. In the case of an external pulsatile LVAD, the air movement through the air line can be used to estimate LVAD outflow. In this study, the air movement in the air-line of the extracorporeal pulsatile LVAD was measured with a differential pressure sensor between different points. The precise estimation of air movement could be achieved by additional measurement of air pressure. In a series of in-vitro experiments, the LVAD outflow were changed according to the afterload of LVAD and the differential pressure of LVAD didn't have close correlation with the LVAD outflow that were measured with an ultrasonic flowmeter at the same time. However, new precise estimation with the data from differential pressure and one point pressure in the air-line showed higher correlations with LVAD outflow.

전자제어 엔진의 공기유량센서 유동구조 연구 (Flow Mechanism around Air Flow Sensor of Electronic Control Engine)

  • 이종춘;황성만;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.486-493
    • /
    • 2000
  • Flow mechanism around air flow sensor of electronic control engine, especially Karman vortex type, was investigated experimentally. The two-dimensional flow characteristics in the intermediate wake region behind a triangular vortex-generator respectively apex forward facing, apex backward facing and vertical flat plates following after apex forward facing(i.e vortex-flowmeter) were investigated at Reynolods number of $ReH=1.4\times10^4$; H is the width of a triangular vortex-generator. The vortex shedding frequency for wide Reynolds number from $7\times10^3$ to $2.1\times10^4$ was also surveyed. The velocity component was measured by X-type hot wire anemometer at 8H downstream from the bluff body. The coherent structure of the intermediate wake behind a bluff body was obtained by conditional phase average technique. As a result, it was verified that the vertical flat plates following after apex forward triangular vortex-generator make not only more linear relation between free stream velocity and vortex shedding frequency but also more periodic vortex in the vicinity of the center of wake.

  • PDF

온도, 유동특성 및 지화학분석 자료를 이용한 지표수-지하수 연계특성 평가 (Evaluation of Interactions Between Surface Water and Groundwater Based on Temperature, Flow Properties, and Geochemical Data)

  • 전항탁;김규범
    • 지질공학
    • /
    • 제21권1호
    • /
    • pp.45-55
    • /
    • 2011
  • 본 연구에서는 소하천변 충적층을 대상으로 9개 지하수 관측공내 유속 실험과 온도 계측을 통한 시간별, 심도별 온도 변화 추이 평가 및 지화학 분석 등을 통하여 지표수와 지하수간의 상호 작용에 대하여 분석하였다. 하천변에 근접한 2개 지하수 관측공은 타 관측공과 달려 지하수 유향이 하천에서 주변 충적층으로 향하고 있으며, 계절에 따른 온도 변화가 대기 및 하천과 유사하게 나타난다. 또한 이들 지점은 하천수의 영향을 받은 지화학 특성을 보일 뿐 아니라 계절에 따라 지화학 특성이 변화하는 등 지표수의 유입 유출이 활발한 지점에 해당한다. 본 연구에서 사용된 온도 측정 장치인 Thermochron I-button은 저비용의 소규모 장치로서 지표수와 지하수의 상호 작용 평가에 활용도가 높다.

오리피스 유량계에서 게이지라인 누설에 의한 계량오차 (The Measurement Error owing to Leakage of Gaugeline in Orifice Flowmeter)

  • 이철구;하영철;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.143-148
    • /
    • 2003
  • This study was experimentally performed in order to estimate the errors due to the leakage of transmitter gaugelines in the orifice flow meter for natural gas. It would be a serious problem in safety if a large quantity of leak was occurred at the tubes or fittings like valve. But in most cases the safety problems might be rarely happened because the gas leak detectors could be operated in advance and the various kinds of inspection would be also fulfilled periodically. If the leakage was occurred continuously with an undetectable amount at the gaugelines for measuring the pressure or the differential pressure(DP), the amount of leakage might be an error or an unaccounted flow(UAE). In addition if the measuring value of pressure or DP were affected by the leakage, it might also be a measurement error. The experiments were performed to estimate the amount of leakage and to check the DP changes if it exited. First, through the measurement of the air pressure changes in the airtight container connected to a transmitter with gaugelines as the time passed, the amount of leakage causing from the fittings of gaugelines was roughly estimated. As changing the leak position of the gaugeline, the leak was intentionally made to break out. The variance of DP was checked as controlling the extent of leakage and compared to no leak conditions. Consequently, under the normal maintenance conditions, the result represented that the amount of leakage causing from the gaugelines was insignificant and also the DP changes on leakage conditions were too small to cause the errors of measurements.

  • PDF