• Title/Summary/Keyword: Air flow sensor

Search Result 143, Processing Time 0.023 seconds

Analysis for Internal Flow of Tube on the Self Inflating Tire Using the FSI Method (FSI 기법을 이용한 Self Inflating Tire의 펌핑 튜브 내부 유동 해석)

  • Kim, Myeongjun;Seong, Inchul;Hwang, Inkyeong;Park, Taewon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.6
    • /
    • pp.660-667
    • /
    • 2016
  • Maintaining proper tire air pressure is an essential element in ensuring vehicle safety. UHP Tires that boast of many safety features are increasing in the market. In particular, the development of "Self-Inflating Tire" technology is accelerating around the globe. Self-inflating tire refers to a technique for maintaining appropriate tire pressure. An internal regulator senses when tire inflation pressure has dropped below the set air pressure. The tire boosts air through the valve when rolling and compressed air enters into the tire. This procedure keeps the tire air pressure at an appropriate level and increases tire safety. Flow analysis of the internal tube is required to examine self-inflating tires. In this study, a method of tube flow analysis using the FSI Method is proposed. The valve system is also implemented to optimize the regulator and sensor.

Fine Gap Control Using Pneumatic Servo System (공압서보시스템에 의한 미세 간극제어 시스템 설계)

  • 김동환;김영진;정대화
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.45-56
    • /
    • 2002
  • A pneumatic servo system requiring a fine gap control in a photo-electric sensor which is used for a LCD array detection device is introduced. The gap controlled by the pneumatic servo system remains within around 50~80 ${\mu}{\textrm}{m}$, and the system possesses an effect to eliminate undesirable particles on the LCD plate by blowing air out. The air flow rate is initially controlled by a servo valve and expanded by a booster valve, thus the controlled air pressure contributes to maintaining an appropriate gap between the LCD plate and photo-electric sensor An air floating plate of two degrees of freedom is designed and fabricated, and a fine tilting motion control is also implemented by assigning different gap commands. The pressure control and direct gap control are proposed, and each performance is verified experimentally.

EM Algorithm based Air Flow and Power Data classification Analysis (EM 알고리즘기반의 공기 유량 및 전력 데이터 분류 분석)

  • Shim, Jae-Ryong;Noh, Young-Bin;Jung, Hoe-kyung;Kim, Yong-Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.551-553
    • /
    • 2016
  • Since air compressor, as an essential equipment used in the factory and plant operations, accounts for around 20% of the total domestic electricity consumption, a real time sensor data monitoring based analysis for electricity consumption reduction is important. In particular, flow rates and pressures of these monitored variables has a direct correlation with the power consumption. This paper proposes a method to identify if the measurement error of the flow rate sensor comes from the sensor measurement limit through bivariate classification analysis of the flow rate and power using the EM (Expectation and Maximization) Algorithm and show how to enable more accurate analysis by the correlation between the flow rate and power on the right-censored data.

  • PDF

Flow Analysis and Flight Experiment for Optimum Height of Weather Data Sensor (기상데이터 센서의 최적 높이를 위한 유동해석 및 비행실험)

  • Kim, Young-in;Ku, SungKwan;Park, ChangHwan
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.551-556
    • /
    • 2018
  • In recent years, drones have been used to measure aircraft flights data and weather information. Related applications include the measure for low-altitude atmospheric data, the measure for atmospheric fine dust, and the measure for air pollution. However, the mounting position of the atmospheric measurement sensor should be mounted by considering the effects of propeller flow, the EMI effects, and the changes in the weight of the drone. Among these, the upper flow of the propeller affects the wind speed and direction, so the optimal position should be selected. This study deals with the proper height of the atmospheric data measurement sensor. Through the flow analysis, we study the flow characteristics of around a drone and suggest the proper sensor mounting height.

Experimental study on analysis of correlation between void fraction and drag reduction rate in air lubrication ship (공기윤활선 모사 실험에서의 공극률 및 마찰저항저감율 상관성 분석을 위한 실험적 연구)

  • Park, Seungchan;Lee, Inwon
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.1
    • /
    • pp.11-17
    • /
    • 2020
  • The reduction of CO2 emissions has been a key target in the marine industry since the IMO's MEPC published its findings in 2009. Air lubrication method is one of the mature technologies for commercialization to reduce the frictional resistance and enhance fuel efficiency of ships. Since the air lubrication pattern varies according to the ship's standing position and injection flow rate, in order to effectively control the air lubrication system, it is necessary to be able to judge the air layer development state based on the information collected from the monitoring sensor. In this study, we performed the air lubrication ship simulation experiment to measure the void fraction and the frictional resistance. The void fraction was measured to confirm the behavior of the air. Through the measurement of the frictional resistance, the change in frictional resistance reduction rate from the injection point to the longitudinal direction of the ship was confirmed. Based on the measurement results, correlation analysis was performed on void fraction and frictional resistance reduction rate.

Lean burn Combustion Characteristics of Direct Injection Gasoline Engine with Swirl Control Valve (스월 제어 밸브를 적용한 직접분사식 가솔린 엔진의 희박연소 특성)

  • Lee, Min-Ho;Moon, Hak-Hoon;Cha, Kyung-Ok
    • Journal of ILASS-Korea
    • /
    • v.9 no.2
    • /
    • pp.9-17
    • /
    • 2004
  • The performance characteristics of lean burn system in gasoline engine are mainly affected by the air-fuel mixture in cylinder, gas exchange process of manifold system, exhaust emission of engine, and the electronic engine control system. In order to obtain the effect of performance factors on the optimum conditions of lean burn engine, this study deal with the behavior of mixture formation, gas flow characteristics of air, flow and evaporation analysis of spray droplet in cylinder, vaporization and burning characteristics of lean mixture in the engine, and the control performance of electronic engine control system. The optimum flow conditions were investigated with the swirl and tumble flows in the combustion chamber with swirl control valve. The performance characteristics and optimum condition of flow field in intake system were analyzed by the investigation of inlet flow of air and combustion stabilization on cylinder.

  • PDF

Flow Noise in the Outdoor Unit of an Air-conditioner (에어컨 실외기에서의 유동소음)

  • 이승배;이재환;김휘중;최진규;진성훈;박윤서
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.594-601
    • /
    • 1997
  • Propeller fans are commonly equipped in outdoor units of air-conditioners to provide effective cooling in a dried heat exchanger. A new design technique was developed to satisfy requirements of aerodynamic and aeroacoustic performance, which employs the intersection method of two cylinders for mean camber line. Three proto-types of propeller fan including Palm-Shaped, Highly-Swept(PSHS) fan (proto 3)were not only to provide low lift forces for dipole sound, but also to reduce the organized tip vortices interacting with the fan guide causing narrow-banded rotating instabilities. Cross-correlation technique was applied to study flow noise source characteristics for three proto-type fans designed. The cross-correlations between a microphone at far field and a hot-wire sensor at near field show that flows near hub region of proto 3 fan are less organized and the flow structures especially at high flow rate coefficients for proto 3 fan are less correlated with noise generated than other proto-types fans.

  • PDF

Estimation and Uncertainty Evaluation on Mass Flow Rate of Air Intake by Using Air Data (비행정보를 이용한 흡입구의 공기유량 추정 및 불확도 평가)

  • Park, Iksoo;Park, Jungwoo;Ki, Taeseok;Choi, Jin;Lee, Juyoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.3
    • /
    • pp.14-20
    • /
    • 2018
  • An estimation law of air mass flow rate for high speed engine control is presented. The variables of mass estimation equations are modified to measurable variables which can be obtained during flight, and the effectiveness of each variable to the estimation accuracy is evaluated. The equation is modified to a simplified form, and the uncertainty is evaluated. In addition, reference data for the selection of estimation methods is suggested by considering the sensitivity analysis of sensor error.

Effects of Cooling Flow Rate on Gas Foil Thrust Bearing Performance (냉각 유량이 가스 포일 스러스트 베어링의 성능에 미치는 영향)

  • Sung Ho Hwnag;Dae Yeon Kim;Tae Ho Kim
    • Tribology and Lubricants
    • /
    • v.39 no.2
    • /
    • pp.76-80
    • /
    • 2023
  • This paper describes an experimental investigation of the effect of cooling flow rate on gas foil thrust bearing (GFTB) performance. In a newly developed GFTB test rig, a non-contact type pneumatic cylinder provides static loads to the test GFTB and a high-speed motor rotates a thrust runner up to the maximum speed of 80 krpm. Force sensor, torque arm connected to another force sensor, and thermocouples measures the applied static load, drag torque, and bearing temperature, respectively, for cooling flow rates of 0, 25, and 50 LPM at static loads of 50, 100, and 150 N. The test GFTB with the outer radius of 31.5 mm has six top foils supported on bump foil structures. During the series of tests, the transient responses of the bearing drag torque and bearing temperature are recorded until the bearing temperature converges with time for each cooling flow rate and static load. The test data show that the converged temperature decreases with increasing cooling flow rate and increases with increasing static load. The drag torque and friction coefficient decrease with increasing cooling flow rate, which may be attributed to the decrease in viscosity and lubricant (air) temperature. These test results suggest that an increase in cooling flow rate improves GFTB performance.

A Study on the Noise Reduction and Performance Improvement of the Hot Water Distributing System (시스템분배기 소음방지 및 성능개선방안 연구)

  • Kim, Yong-Ki;Lee, Tae-Won;Han, Tae-Su;Yoo, Sun-Hak
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1055-1060
    • /
    • 2009
  • Noise is one of the major environmental problems in human life. But hot water distributers with the flow rate control valve bring about often noise according to the heating control condition in residential buildings. The sound power level increased as the flow rate and pressure difference increased. And thus, experimental analyses for the flow rate control and the pressure difference control were carried out in this study to reduce the noise emitted from the flow rate control valve. As the results, the flow rate control method using a SMA(Shape Memory Alloy)-valve and the flow rate control system using a pressure difference sensor can be expected to control noise in the region of below 50 dB of sound power level.

  • PDF