• 제목/요약/키워드: Air flow distribution

검색결과 925건 처리시간 0.027초

수치시뮬레이션에 의한 공기부양선 주위의 유동장해석과 조파저항계산 (Numerical Analysis on Flow Fields and the Calculation of Wave Making Resistance about Air Supported Ships)

  • 나영인;이영길
    • 한국전산유체공학회지
    • /
    • 제1권1호
    • /
    • pp.55-63
    • /
    • 1996
  • Numerical computations are carried out to analyze the characteristics of flow fields around Air Supported Ships. The computations are performed in a rectangular grid system based on MAC(Marker And Cell) method. The governing equations are represented in finite difference forms by forward differencing in time and centered differencing in space except for its convection terms. For the certification of this numerical analysis method, the computations of flow fields around a Catamaran, an ACV(Air Cushion Vehicle) modeled with pressure distribution on free surface and two SES(Surface Effect Ship)'s are carried out, The results of the present computations are compared with the previously presented computational and experimental results in the same condition.

  • PDF

Y-Jet 노즐에서의 혼합관 길이변화에 따른 분무특성 연구 (Change of Spray Characteristics with Mixing Port Length of Y-Jet Atomizers)

  • 송시홍;이상용
    • 대한기계학회논문집
    • /
    • 제18권11호
    • /
    • pp.3021-3031
    • /
    • 1994
  • Experiments have been performed to find out the effect of the mixing port length of Y-jet atomizers on the spray performance, using air and water as the test fluids. Water and air flow rates and drop sizes were measured at each injection pressure condition for different mixing port length. The air flow rate was almost unaffected by the change of the mixing port length. However, the water flow rate was relatively susceptible to the change of the mixing port length. The mixing point pressure was very much influenced by the mixing port length. Variations of spatial distribution of Sauter Mean Diameter (SMD, $D_{32}$) and the cross-section-averaged SMD ($D_{32,m}$) with different mixing port length and air/water mass flow rate ratio were examined. Generally, when the mixing port length was reduced, the mean drop size decreased and became spatially even.

PIV에 의한 냉장고 기류특성 평가방법 (A Diagnostic Technique for the Air Flow Characteristics in Refrigerators using PIV)

  • 김석로;도덕희;이재근;김경천
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.576-584
    • /
    • 2007
  • A PIV(Particle Imaging Velocimetry) diagnostic technique for the evaluation of the flow characteristics in refrigerator is introduced. Smoke particles of which density is small enough to follow up the air flow are used for visualization of the air flows in the refrigerators. A rectangular room model is tested for the verifications of the dignostic technique. By evaluating the turbulent intensity and the deviation value of the turbulent intensity distribution that were obtained from PIV results, an optimal ventilating condition is suggested. The constructed technique is used for the diagnostics on the flow of an actual refrigerator. It has experimentally proved that the present technique is able to evaluate the ventilation conditions of refrigerators.

  • PDF

이차원 다중젯트의 유동 및 열전달 특성의 수치적 해석(I) -돌출열원이 없는 경우의 유동특성- (A Numerical Analysis of Flow and Beat Transfer Characteristics of a Two-Dimensional Multi-Impingement Jet(I))

  • 장대철;이기명
    • Journal of Biosystems Engineering
    • /
    • 제20권1호
    • /
    • pp.58-65
    • /
    • 1995
  • A numerical study for a two dimensional multi-jet with crossflow of the spent fluid has been carried out. Three different distributions of mass-flow rate at 5 jet exits were assumed to see their effects upon the flow characteristics, especially in the jet-flow region. For each distribution, various Reynolds numbers ranging from laminar to turbulent flows were considered. Calculations drew the following items as conclusion. 1) The development of the free jets issued from downstream jets was hindered by the crossflow formed due to jets. Consequently, the free jet was developed into the channel flow without any evident symptom of impingement jet flow characteristics 2) The crossflow induced the pressure gradient along the cross section of jet exits and the value of the pressure gradient increased as going downstream. The crossflow generated also the turbulent kinetic energy as it collied with the downstream jets. 3) The skin friction coefficient along the impingement plate was affected more by the distribution of mass flow rate at jet exits rather than by the Reynolds number. The skin friction coefficient was inversely proportional to the square root of the Reynolds number, regardless of flow regime when a fully developed flow was formed in the jet flow region. 4) The distribution of the skin friction coefficient along the impingement plate was found to be controlled by adjusting the distribution of mass flow rate at jet exits.

  • PDF

에어믹서가 설치된 공조기 혼합실 내의 온도분포에 관한 실험적 연구 (An Experimental Study of Temperature Profiles in Mixing Zone of AHU with an Air Mixer)

  • 박권종;이석준;장영근
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.999-1006
    • /
    • 2006
  • A study of temperature profiles in mixing zone of AHU (air handling unit) can contribute greatly to enhance performance of AHU system, so the study on the temperature distribution between RA (return air) and OA (outdoor air) is important to analyze the mixing characteristics in a mixing zone of AHU. Accordingly, the temperature profiles during RA (return air) and OA (outdoor air) supply process into mixing zone of AHU with an air mixer are studied experimentally. The effect of air mixer, OA temperature and RA/OA flow rate are studied in detail. In this study, the results show that the mixing efficiency is all high for installed the air mixer. The more OA temperature increase and OA flow rate decrease, the more mixing efficiency is high.

냉난방 온도감지 디퓨져의 간극변화에 따른 기류분포 특성 (Air Distribution Performance According to the Gap Opening of a Temperature Controlled Diffuser)

  • 한화택;신민우;염철민;최선호
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.180-185
    • /
    • 2006
  • This study has been conducted in order to develop a temperature-controlled round pan diffuser with variable-openings. Flow visualization was performed to investigate the airflow patterns according to gap openings. The velocity profiles were measured using an omni-directional anemometer for two cases, i.e. a horizontal and a vertical discharge conditions. Numerical simulation also confirms there is a narrow range of gap openings where a horizontal discharge shifts to a vertical discharge. The air distribution performance index increases abruptly when the air discharge shifts from vertical to horizontal direction.

오염농도 분포 해석을 통한 공동주택의 자연환기성능 향상을 위한 평면계획 (Planning of Apartment Units for Improving Natural Ventilation Performance based on the Analysis of Indoor Pollutant Concentrations)

  • 김지영;이승희;김태연
    • KIEAE Journal
    • /
    • 제5권3호
    • /
    • pp.41-48
    • /
    • 2005
  • Before occupation of an apartment housing, the builders are required to inform the test result of IAQ to the public. However, there is no simplified method to predict IAQ before measurement of pollutant concentration. In this study, a simplified way of predicting IAQ based on the distribution of indoor pollutant concentration is proposed. 7 different cases of air change rate have been simulated through CFD analysis to get the distribution ratio of each pollutant material and then simplified functions were used with CRIAQ1 values derived from CFD simulation to evaluate by comparing the influence of each material in the indoor pollutant concentration. Again, a lot of efforts which can improve the indoor air quality have been performed. Materials used in indoor space are labeled with their pollutant emission level. Installation of ventilation system in residential buildings will be regulated by a building codes sooner or later. But it is important to understand the fact that layout of walls, location or size of openings will influence the indoor air flow and pollutant concentration. And location of emitting material influences to indoor air pollutants distribution. But until now there is few recognition and consideration of these factors. Therefore, in this paper the effects of these factors is proved and some kind of guideline is made for designers after a comparison of typical apartment floor plan and a new type plan with their average pollutant concentration and its distribution of each room. CFD(Computational Fluid Dynamics) program was used to show the indoor air flow and pollutant concentration distribution. For this purpose, a typical $100m^2$ apartment floor plan was chosen as a case study model and several alternatives were reviewed to improve the IAQ performance. The simulation took place in the condition of natural ventilation through windows.

경비행기 프로펠러의 공기 유동해석에 관한 융합 연구 (A Convergent Investigation on the Air Flow Analysis of a Light Aircraft Propeller)

  • 최계광;조재웅
    • 한국융합학회논문지
    • /
    • 제11권12호
    • /
    • pp.131-135
    • /
    • 2020
  • 본 연구에서는 경비행기를 날게 하는 프로펠러인 3개 및 5개 또는 10개가 있는 날개의 모델들로서 공기 유동 해석을 하였다. Model A에 대해서는 5개의 날개들이 있는 유동 형상으로서 Model A가 가장 이상적인 공기의 흐름을 보이고 있다. 너무 많거나 적지도 않은 날개 수로 공기의 흐름이 가장 원활히 흐르는 형상을 나타내고 있다. 프로펠러 날개의 수가 적으면 적을수록 공기의 유동이 작아지는 것을 볼 수 있다. Model A는 공기 유동의 전면부에서 최대 0.5631 MPa의 압력을 받고 있다. 또한 Model B와 Model C는 0.5758 MPa 및 0.5589 MPa의 압력을 각각 받고 있다. 각 유동 모델들에 대한 압력 등고선들을 비교해 보면, Model B가 그 압력 분포가 제일 높은 것으로 볼 수 있다. 본 연구 결과를 활용하면 실제 시험을 하지 않고서도 공기 유동을 조사할 수 있다. 또한 경비행기 프로펠러의 미적인 융합 설계에 도움이 될 수 있다고 보인다.

소결로 배기가스 재순환 시스템 내의 유체유동 특성 연구 (Fluid-flow Characteristics of Flue-gas-recirculation System in Sintering Plant)

  • 문찬희;김현동;김경천
    • 한국가시화정보학회지
    • /
    • 제16권2호
    • /
    • pp.7-15
    • /
    • 2018
  • The fluid-flow characteristics of flue-gas-recirculation (FGR) system can have a significant effect on system efficiency of a sintering plant. The flow characteristics in the system were investigated. A sintering plant with FGR system was modeled. Numerical visualization was performed and flow characteristics were analyzed. Characteristics of the flow distribution of the branch ducts, the inflow of air into the recirculating hood, and the flow in the hood were discussed. Based on the results three suggestions were proposed: (1) distribution of branch duct flowrate upstream, (2) installation of external air ducts in the hood, and (3) installation of baffles at the hood corners. The suggestions were tested numerical and experimental visualization methods. The suggestions were effective and confirmed to be applicable to the actual sinter plant.

2차 공기 주입각이 소각로 내부의 온도 분포 균일도에 미치는 영향 (Effects of the angle of secondary air inlet on the uniformity of temperature distribution inside an incinerator)

  • 김성준;민인홍;박명호;박민주
    • 한국전산유체공학회지
    • /
    • 제5권3호
    • /
    • pp.8-15
    • /
    • 2000
  • This research is aimed to find out how the inlet angle of secondary air affects the uniformity of temperature distribution inside a small incinerator. A commercial code, PHOENICS, is used to simulate the thermal-flow field of an incinerator. The computational grid system is constructed by Multi-Block technique provided by PHOENICS. Numerical experiments are done with the five different angles of secondary air inlet. The uniformity of temperature distribution is evaluated by checking the standard deviation of temperature distribution in an incinerator. The computational results show that there is the minimum value of standard deviation at the certain angle of secondary air inlet, which means that there is an optimum angle of secondary air inlet that could improve the uniformity of temperature distribution in an incinerator. The optimum angle of secondary air inlet is between 30 degree and 45 degree in this particular case.

  • PDF