• Title/Summary/Keyword: Air environment

Search Result 10,267, Processing Time 0.035 seconds

A study on the effect on indoor air quality by ventilation system operation in buses (고속버스 운행시 공조시스템 조건에 따른 객실 내 실내공기질 변화)

  • An, Sun-Min;Lee, Jung-Sub;Shim, In-Keun;Kim, Ho-Hyun
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.346-354
    • /
    • 2018
  • In this study, the condition of the hazardous materials in the bus was monitored according to the ventilation mode of the air conditioning system during bus service. The bus was surveyed using the indoor air quality measurement method of public transportation vehicles within one year of delivery. We evaluate the $CO_2$ and $PM_{10}$, which are the controlled parameters in buses by the Ministry of Environment, and VOCs and HCHO, the non-controlled parameters. The $PM_{10}$ concentration increased due to outdoor air intake; however the $CO_2$ concentration was found to decrease. In addition, the concentration of VOCs and HCHO was found to decrease due to the forced ventilation system and the outdoor air intake. These results show that the concentration of the other materials except $PM_{10}$ can be changed due to the outside air concentration and forced ventilation system. Therefore, through indoor air quality characteristics of the bus according to air condition system are intended to be used as the basis of an operation manual.

A Survey on Management Status of Personal Air Sampler in Domestic Provider for Work Environment Monitoring Service (국내 작업환경측정기관들의 개인시료 채취기 운용현황 실태 조사)

  • Kim, Ki-Youn;Cho, Man-Su;Ma, Hye-Lan;Lee, Kwang-Young;Jeong, Jee-Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.359-364
    • /
    • 2014
  • Objectives: The principal aim of this study is to provide fundamental data for suggesting substantial management plan of personal air sampler by investigating current situation of work environment monitoring service provider. Materials and Methods: The questionnaires regarding a personal air sampler were sent by electronic mail to 150 institutions, except for 22 institutions which are out of business or closed temporarily, among total 172 domestic work environment monitoring service providers designated by Ministry of Employment and Labor based on 2013. The institutions which did not reply to the questionnaire for 30 days were required directly by phone call. Finally 97 institutions gave an answer to the questionnaire and therefore the respondence rate was 65%. Results: The normal operation rate of personal air sampler exceeded 70% in all the types (particle, gas and both combination) in terms of purchased year. Furthermore the personal air sampler purchased recently showed a trend of high operation rate compared to the personal air sampler purchased previously. The distribution patterns of personal air sampler In terms of manufacturers were Gillian>MSA>SKC for particle, Gillian>SKC>AMETEK for gas and Gillian>MSA>Casella for both combination, respectively. As a result, it was found that the personal air sampler manufactured by Gillian company was utilized the most in domestic work environment monitoring service provider regardless of types of personal air sampler. Conclusions: Based on the results obtained from this study, the normal operation rate according to types of personal air sampler was as follows: 94% for personal air sampler for collecting particle only, 93% for personal air sampler for collecting gas only and 89% for collecting both particle and gas. Overall, the numbers of personal air sampler possessed and operated normally in domestic work environment monitoring service provider were 5,458 and 5,062, which indicates the normal operation rate of personal air sampler in total aspect is 93%.

Air Change Rate Measurement Methods and Database

  • Lee, Kiyoung;Yukio Yanagisawa
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.E
    • /
    • pp.1-12
    • /
    • 1995
  • In recent years the demand for energy conservation has resulted in "tight" buildings with decreased air change rates. Although a reduction in air change rates can save energy utilized for heating or cooling of dwellings, there is an increased concern for the air quality of the indoor environment where individuals spend most of their lifetime (Schwab et al., 1990).., 1990).

  • PDF

The Investigation and Comparison of Characteristics of Air Pollution for Cohort Study in Chungju with Industrial Cities (대조코호트 연구를 위한 충주의 대기오염현황 조사와 산단지역과의 비교)

  • Kim, Jae-Hoon;Wee, Seong-Seung;Nam, Sang-Hoon;An, Jung-Sun;Kim, Dae-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • The purpose of this study was to investigate air quality in Chungju, Korea, using data obtained with a local air quality monitoring system. We have utilised cohort studies to investigate the relations between environmental pollution and the health of residents near large industrial complexes since 2004. This study analyzes the $O_3,\;NO_2,\;SO_2,\;CO\;and\;PM_{10}$ concentration in Chungju from 2002 to 2006. Air pollutants are closely related to the number of manufacturing facilities and cars, energy utilization and weather conditions. Generally, the diurnal concentration of air pollutants in Chungju reached the highest level in the morning (about$08:00{\sim}$) and early evening (about$19:00{\sim}$). On the other hand, the diurnal concentration of ozone as recorded gives the highest amount in late afternoon (about$16:00{\sim}$) and lowest in early morning (about$08:00{\sim}$). The concentration of air pollutants in Chungju was highest from winter to spring and lowest during the summer season. On the other hand, the monthly variation of ozone concentration was greatest in June and smallest in December. Also the, $PM_{10}$ concentration posted the highest record in April and the lowest during September. In general, this study analyzed air pollution changes in Chungju as well as in large scale industrial complex regions within Korea such as Ulsan, Pohang, Kwangyang, Sihwa Panwol and Gangneung in Korea. We compared the air quality of Chungju with those of these cites and found that air pollutants except for CO in Chungju was generally lower than large industrial complex regions.

Estimation of Air Pollution by Distribution of Epiphytic Bryophtes in Chonnam Area (선태식물을 이용한 전남지역 대기오염도 평가)

  • Yang, Soo-In;Ha, Hoon;Rim, Hang-Seon;Park, Chan-Ok;Hong, Suk-Soon;Jeong, Beung-Seuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.137-144
    • /
    • 1995
  • The I.A.P.(Index of Atmospheric Purity) by the distribution of Bryophtes on the bark of various latifoliate tree trunks was investigated at four sites(Daeheung, Songkwang, Jeungsim, and Heunggook Temple) from April, 1991 to April, 1993. The IAP was in inverse proportion to the degree of air pollution. The I.A.P at four sites were estimated 78.2 at Daeheung temple, 61.0 at Songkwang temple, 28.3 at Jeungsim temple, and 10.3 at Heunggook temple, respectively. The distribution degree of Bryophytes in Heunggook temple progressed during the last ten years. It represents the bettrment of air quality. Bioassay by means of lichens seems to have great potential for better and less expensive ways of measuring pollution levels instead of the high cost of buying and maintaining air pollution monitoring equipment.

  • PDF

The Characteristics of Monoterpene and Air Quality in Ambient Air at Forested Road in Jeollanam-do (전남지역 숲길의 모노테르펜류 농도와 공기질 특성)

  • Oh, Gil-Young;Seo, Yun-Gyu;Park, Gui-Hwan;Kim, Ik-San;Bae, Ju-Soon;Park, Hye-Young;Yang, Soo-In;Jeon, Jun-Min;Jeong, Man-Ho;Seo, Yun-Seob;Lee, Wan-Jin
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.2
    • /
    • pp.195-202
    • /
    • 2012
  • Three-season field study was conducted to investigate the distribution of monoterpene(10) and air anion in ambient air at five forests. ${\alpha}$-Pinene, camphene, sabinene, ${\beta}$-pinene, myrcene, terpinolene, limonene, 1,8-cineol, linalool, and camphor were quantified in the samples collected. The highest 4-hour mean concentration of total monoterpene were ${\beta}$-pinene+myrcene as 958 pptv at Juknokwon dominated by bamboo and ${\alpha}$-pinene (524 pptv), limonene (445 pptv) at Wood Land and Suncheon Bay, respectively. The seasonal means were observed to peak during spring with their maximum at Wood Land and Seonam Temple and during summer at Juknokwon and Suncheon Bay. The 24 hour concentration mean of atmosphere standards were found with much lower values than those by law. The highest concentrations of air anion were measured $400{\sim}3,000ea{\cdot}mL^{-1}$ through the sites. There is no significant correlation between the concentration of monoterpene and air anion.

Spatial Distribution of Air Temperature during an Extreme Heat Period in Daegu Metropolitan Area in 2016 (2016년 여름철 폭염 시기 대구의 기온공간분포 특성)

  • Kim, Ji-Hye;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.26 no.9
    • /
    • pp.1023-1029
    • /
    • 2017
  • We studied the distribution of air temperature using the high density urban climate observation network data of Daegu. The observation system was established in February 2013. We used a total of 38 air temperature observation points (23 thermometers and 18 AWSs). From the distribution of monthly averaged air temperatures, air temperatures at the center of Daegu were higher than in the suburbs. The daily minimum air temperature was more than or equal to $25^{\circ}C$ and the daily maximum air temperature was more than or equal to $35^{\circ}C$ at the elementary school near the center of Daegu. Also, we compared the time elements, which are characterized by the diurnal variation of surface air temperature. The warming and cooling rates in rural areas were faster than in urban areas. This is mainly due to the difference in surface heat capacity. These results indicate the influence of urbanization on the formation of the daily minimum temperature in Daegu.

A Pilot Study of Improving the Atmospheric Environment of Classroom for Students' Learning Activities

  • Kim, Tae-Han;Lee, Hanju;Choi, Boo-Hun;Hyun, Hye Sun
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.2
    • /
    • pp.179-194
    • /
    • 2021
  • Background and objective: Plant-based biofilter system has become a promising candidate for improving indoor air quality due to its eco-friendly and sustainable nature. However, it remains controversial whether indoor air purification using a biofilter is effective. Methods: This study used the one-group pre- and post-test design to analyze the effects of the operation of the plant-based biofilter system on indoor air quality, students' perception of indoor air quality, health effects, and subjective and objective attentiveness. Results: Results of this study show that the application of the plant-based biofilter system changed the air environment in the classroom. The operation of the plant-based biofilter system significantly decreased PM2.5 and PM10 and slightly increased temperature and humidity. Satisfaction with air quality and subjective attentiveness were significantly improved but objective attentiveness and health effects were not improved. Conclusion: Further studies need to be conducted for improving indoor air quality of schools and evaluating the health effects and attention of occupants to present the objective performance of the plant-based biofilter system.

A Review of the Integrated Strategy for Climate Change and Air Pollution Management (기후변화와 대기환경의 통합적 관리에 대한 고찰)

  • Song, Chang-Keun;Lee, Suk-Jo;Yoon, Jong-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.805-818
    • /
    • 2011
  • The unequivocal risk of climate change, the weakness of energy security, and the problem of air quality will be possibly accelerated by the same reason, the enhanced fossil fuel dependancy in the future. It is obvious that greenhouse gases and air pollutants are mainly emitted from same sources. Moreover, greenhouse gases and air pollutants have their adversed impacts on same socio-economical, and environmental sectors. With these regards, several but limited studies have emphasized on the importance of the integrated management of climate change and air quality problem. In this study, we address the current trend of energy consumption and the change of air quality condition. Also the related policies are checked out in order to reduce emissions of greenhouse gases and air pollutants in Korea. By surveying previous studies, it is shown that the cost of climate change actions can be reduced by air quality co-benefits and vis-a-versa. Also the integrated strategy for climate change and air quality is introduced in term of cost-effectiveness and co-benefit.

Air Quality Measurements and QC/QA (I) -Principles and Methodology (대기환경측정과 정도관리 (I)-원리와 방법론)

  • Baek Sung-Ok;Kim Ki-Hyun;Heo Gwi-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.237-249
    • /
    • 2004
  • With the increasing concern over the air quality degradation, there are growing demands to accurately and precisely measure air quality. In this article, the general principles and approaches were described to help aid proper evaluation of air quality. In order to introduce the basic approaches for conducting field/laboratory experiments and for interpreting experimental data sets, we explained all the common methodologies involved and provided some insights into the desirable protocols for air quality measurements.