• 제목/요약/키워드: Air diffuser

검색결과 184건 처리시간 0.025초

가압식 바닥급기 시스템의 여름철 성층화 경향에 관한 실험적 연구 (An Experimental Study on Thermal Stratification of Pressurized Plenum Underfloor Air Distribution System during Cooling)

  • 김동희;유기형;조동우;서정석;한성필
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.340-345
    • /
    • 2007
  • The underfloor air distribution system has been attracting to architects and building owners as one of valuable system for the renovated and newly office building. In this paper, we discussed the thermal stratification profile of pressurized plenum underfloor air distribution(UFAD) according to indoor setting temperature, diffuser number, diffuser type. For this, the space of office building(H corp.) is selected for measuring the air volume of underfloor diffuser and vertical temperature profile. As a result, the thermal stratification profile is influenced by the number and type of the underfloor diffuser and thermal storage character of the underfloor. Whereas indoor setting temperature have a lower significant impact on thermal stratification.

  • PDF

디퓨저/노즐을 이용한 압전형 마이크로 펌프의 펌핑 특성에 미치는 입출구 위치의 영향 (Effect of Inlet and Outlet Position on the Pumping Characteristics of a Diffuser/Nozzle Based Piezoelectric Micropumps)

  • 장훈희;김창녕;정진
    • 설비공학논문집
    • /
    • 제19권5호
    • /
    • pp.411-417
    • /
    • 2007
  • This study has been conducted to investigate pumping characteristics of diffuser/nozzle based piezoelectric micropumps. The micropumps include a piezo disk (an actuator), a chamber and a set of diffuser and nozzle. Flow in the current micropumps is controlled by a set of diffuser and nozzle, not by a nap valve. The diffuser/nozzle based micropumps are more reliable in operation and are easier in manufacturing than the flap valve based micropumps. The flow rates of the piezoelectric micropumps have been closely analyzed with a numerical calculation. It has been found that the positions of the inlet and outlet of the micropump can influence the performance of the diffuser/nozzle based piezoelectric micropumps. This study may provide fundamental understanding for the design and analysis of the piezoelectric micropumps.

CFD를 이용한 대형매장 냉열원 주변의 공기유동에 관한 연구 (A Study on the Airflow near the Cold Heat Source Using CFD in Merchandising Store)

  • 조성우;박민용;임영빈
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.629-634
    • /
    • 2005
  • This paper performed to predict vertical temperature distribution and air flow near cold heat source in the mass merchandising store. At the height of 150 cm, the vertical air temperature difference between the results of CFD and of measurement field showed $10\%$ near the refrigeration zone and $8.8\%$ near the freezing zone. Therefore, it regarded as appropriate for the using CFD to investigate airflow near the heat sources. The 3 kinds of CFD model were divided by the disposition of diffuser/exhaust and diffuser air temperature. At the refrigeration and freezing zone in the Model 2 and 3, the temperature difference between the front and the back of human model were showed $6.8^{\circ}C\;and\;3.9^{\circ}C$ with diffuser air temperature $17^{\circ}C$ and were showed $6.8^{\circ}C$ and $4^{\circ}C$ with diffuser air temperature $19^{\circ}C$.

다수의 취출구를 갖는 A/C덕트의 최적설계에 관한 연구 (A Study on the Optimum Design of Air-Conditioning Duct with Multiple Diffusers)

  • 김민호;이대훈
    • 한국자동차공학회논문집
    • /
    • 제10권5호
    • /
    • pp.98-106
    • /
    • 2002
  • The airflow characteristics of an air-conditioning duct with multiple diffusers were investigated through one-dimensional analysis, CFD simulation and experimental measurement. One-dimensional program based on Bernoulli's equation and minor loss equations was developed in order to evaluate the air distribution rate at each diffuser. In CFD simulation, three-dimensional flow characteristics inside air-conditioning duct were computed for incompressible viscous flow, adopting the RNG k-$\xi$turbulence model. Also, in an effort to equalize the discharge flow rate at each outlet, the optimization procedure has been performed to obtain the optimum diffuser area. In this process, square of difference between maximum discharge rate and minimum discharge rate is used as an object function. Diffuser area and discharge velocity are established as constraints. After optimization process, determined design variables are applied again in CFD simulation and experiment to validate the optimized result by one-dimensional program. Comparison with the experimental data of airflow rate distribution showed that the developed program seems to be acceptable and can be useful design tool for an automotive air-conditioning duct in an initial design stage.

수치해석을 이용한 바닥공조 시스템의 공기환경 평가 (Numerical Study on Indoor Air Quality Based on Age of Air for the Underfloor Air Distribution System)

  • 방승기;안혜린;이원근;문기선;김종률;이광호
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.40-46
    • /
    • 2016
  • In order to improve air quality of indoor environment, studies of the underfloor air distribution (UFAD) system for application in buildings are actively in progress based on temperature and air flow distribution. However, although the age of air is the major evaluation parameter, there has been very little study on this parameter for the UFAD system. In this study, we investigated the age of air to reach the air diffuser, which is installed at the bottom of the interior by the UFAD system. Computational fluid dynamics simulations showed no regular pattern to the maximum value of the age of air in accordance with air flow rate and the velocity at air diffuser. These factors can be deduced from air movement by considering that air emitted from air conditioners was rotated according to the bottom shape of the floor, and then, the age of air in the rotation center was increased. The average age of air of internal interior was reduced considerably as the flow velocity at the underfloor air diffuser was increased from 0.5 m/s to 1.0 m/s However, the age of air was not substantially affected with change in the air volume. Moreover, when the flow velocity at the underfloor air diffuser was higher than 1.0 m/s, the age of air showed no significant difference with change in air volume or height of measurement. These results imply that indoor air quality is more substantially influenced by flow velocity than air volume, and the appropriate flow velocity is 1 m/s or more.

미세기포 산기장치를 적용한 타워형 생물반응기의 산소전달 및 수력학적 특성 (Oxygen Transfer and Hydraulic Characteristics in Bubble Column Bioreactor Applied Fine Bubble Air Diffusing System)

  • 이승진;고경한;고명한;양재경;김용국
    • 대한환경공학회지
    • /
    • 제34권11호
    • /
    • pp.772-779
    • /
    • 2012
  • 본 연구에서는 원뿔형으로 개발된 미세기포형 산기관의 성능향상을 위하여 운용적 측면에서 실험과 전산모사적 방법을 이용하였다. 산기관 잠김깊이의 변화에 대해 성능실험이 용이한 실증 규모의 타워형 생물반응기에 산기관을 장착하여, 잠김깊이가 표준산소전달계수($K_{L}a_{20}$) 및 표준산소전달효율(SOTE) 등 산소전달 성능에 미치는 영향을 실험적으로 연구하였다. 또한, 2상 유동에 관한 유체역학적 전산모사를 이용하여 산기관 수와 잠김깊이에 대한 유동현상을 파악함으로써 산소전달 성능변화에 대한 원인을 규명하였다. 산소전달 성능실험결과, 산기관의 잠김깊이를 6 m에서 12 m로 증가시킴에 따라 표준산소 전달계수는 7% 증가하였으나 표준산소전달효율은 39~72% (5.6 %/m)로 대폭 상승하였다. 유동 해석결과, 산기관의 수가 증가함에 따라 공기 체적분율 및 공기와 시험수의 유속 모두 증가하였으며, 공기와 시험수의 유속 경향은 유사하게 나타났다. 잠김깊이가 증가함에 따라서 공기 체적분율, 공기 및 시험수의 유속은 조금씩 감소하는 경향을 나타냈다. 선회 병류유동은 기포류의 확산과 상승속도를 결정하는 주요 인자로서 선회강도가 과도하게 큰 경우에는 기포 체류시간과 체류량이 감소되므로 산소전달 성능을 저하를 예측할 수 있었다.

중형버스 다출구 덕트의 최적설계에 관한 해석적 고찰 (A Numerical Analysis on the Optimum Design of a Duct with Multiple Outlets in a Medium Bus)

  • 김민호;천인범;이대훈
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.223-233
    • /
    • 2002
  • The air distribution duct with multiple outlets is an essential part of automotive air-conditioning system In a bus. The estimation of airflow rate in an automotive air-conditioning duct is typically very complicate due to large variations in cross-sectional area and abrupt changes in flow direction, as well as unbalanced distribution of the flow. In this paper, the flow characteristic in a duct with multiple outlets is investigated through experiment, CFD simulation and a one-dimensional simulation. Numerical simulations have been performed for two simplified air conditioning ducts with multiple outlets used in a medium bus. The three dimensional Navier-Stokes code was used to evaluate the overall pressure, velocity Held, and distribution rate at each diffuser according to the change of various design parameters such as ratio of cross-sectional area and radius of bifurcated region. In addition, a one-dimensional program based on Bernoulli equation was developed to obtain optimized diffuser area required to equalize discharge flow rate at each outlet. As a result of this study, optimized diffuser area of design variable by one-dimensional program was very reasonable as compared to the trend deduced from CFD Simulation. Therefore, the simple and convenient one-dimensional analysis developed in this study can be applied in practical design procedure for air-conditioning duct.

수술실내 공기감염억제를 위한 공조용 급배기구 위치 선정에 관한 연구 (A Study on the Diffuser Location for the Reduction of Airborne Infection in Operation Room)

  • 권순정;주영철;김천숙
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제8권1호
    • /
    • pp.7-12
    • /
    • 2002
  • The air ventilation system of operation rooms has been studied to prevent the cross infection during the operation. Operation rooms and air ventilation systems of three University hospitals were investigated. The distribution of microbe was measured by cultivating air samples in the operation room. A two-dimensional model for the cross-section of an operation room was developed for the CFD(Computational Fluid Dynamics) analysis. The characteristics of air flow in the empty operation room and in occupied operation room were calculated by using a CFD program. The current diffuser location of an old hospital did not deliver the clean air to the operation part efficiently. A new method to locate diffusers that improve air venting with little increase of the cost of equipment was suggested.

  • PDF

냉난방 온도감지 디퓨져의 간극변화에 따른 기류분포 특성 (Air Distribution Performance According to the Gap Opening of a Temperature Controlled Diffuser)

  • 한화택;신민우;염철민;최선호
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.180-185
    • /
    • 2006
  • This study has been conducted in order to develop a temperature-controlled round pan diffuser with variable-openings. Flow visualization was performed to investigate the airflow patterns according to gap openings. The velocity profiles were measured using an omni-directional anemometer for two cases, i.e. a horizontal and a vertical discharge conditions. Numerical simulation also confirms there is a narrow range of gap openings where a horizontal discharge shifts to a vertical discharge. The air distribution performance index increases abruptly when the air discharge shifts from vertical to horizontal direction.

수중폭기용 노즐형 산기관 개발에 관한 실험적 연구 (Experimental Study on the Development of Nozzle-Type Diffusers for Submersible Aeration Process)

  • 임동렬;조남효
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.604-608
    • /
    • 2004
  • Experimental study was conducted to increase the oxygen transfer efficiency of air diffusers in clean water. By measuring the bubble size from the bubbly two-phase flow visualization with several air diffusers the size of air bubbles near the top surface of aeration tank seems to be independent on the diffuser types. Considering design parameters for the better breakup of larger bubbles around the air diffusers, advanced conceptual air diffusers using nozzle-type throat showing the higher oxygen transfer efficiencies were made.

  • PDF