• Title/Summary/Keyword: Air conditioning volume

검색결과 349건 처리시간 0.02초

반송동력과 건물층고 저감형 공조시스템 개발 (Development of HVAC System to Lower the Conveyance Energy and Building Height)

  • 김정엽;신현준
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.116-125
    • /
    • 2003
  • The new HVAC system to lower the conveyance energy and building height using IAV (Increasing Air Volume) technique is developed. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy, size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 per-centage.

Development of HVAC System to Lower the Conveyance Energy and Building Height

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권1호
    • /
    • pp.31-43
    • /
    • 2005
  • The new HVAC system is developed to lower the conveyance energy and building height using IAV(Increasing Air Volume) technique. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy. size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 percentage.

부하변동에 대한 바이패스 공조시스템의 특성 (The Characteristics of a Bypass Air Conditioning System for Load Variation)

  • 김보철;신현준;김정엽
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.240-246
    • /
    • 2002
  • Bypass air conditioning systems are divided into three types; an outdoor air bypass, a mixed air bypass and a return air bypass system. What makes the return air by pass system more effective is that it directs all of moist outdoor air through the cooling coil. The bypass air conditioning system can maintain indoor R.H (Relative Humidity) less than a conventional CAV (Constant Air Volume) air conditioning system by adjusting face and bypass dampers at part load. When a design sensible load (the ratio of sensible load to total sensible load) is 70 percent (at this time, RSHF (Room Sensible Heat Factor) . 0.7), indoor R.H was maintained 59 percent by the return air bypass system, but 65 percent by the conventional CAV air conditioning system (valve control system). The bypass air conditioning system can also improve IAQ (Indoor Air Quality) in many buildings where the number of air change is high.

퍼지 알고리즘을 이용한 정풍량 공조기의 고장 감지 및 진단 (Fault Detection and Diagnosis of a Constant Volume Air Handling Unit by a Fuzzy Algorithm)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.444-451
    • /
    • 2005
  • The fault detection and diagnosis technology may be applied in order to decrease the energy consumption and the maintenance cost of an air-conditioning system. In this study, partial faults for fans, coils, dampers, and sensors of a constant volume air handling unit were considered. A fuzzy algorithm was developed to detect and diagnose these faults. Diagnostic results by the fuzzy algorithm were compared with those by the model reference algorithm. The fuzzy algorithm showed better results in diagnostic accuracies.

요철형상의 CFD 해석을 통한 대용량 로타형 폐열회수열교환기 성능에 관한 연구 (Research on Performance of Large Rotor-type Heat Recovery Exchanger using CFD Analysis on Surface Corrugation)

  • 김동규;하병용;김근오;금종수;정석권
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.875-880
    • /
    • 2012
  • The field of the large volume heat exchanger for wasted heat recovery ventilation system is being expanded enormously seeing as the fact that the quantity of reducing energies are huge due to the large volume heat exchanger for wasted heat recovery system at large buildings and factories, which consume large amount of energies while it has been arising huge amount of losses in Korea because of the lack of technology. To develop large volume waste heat recovery heat exchanger, rotor type heat exchanger was simulated for the surface corrugation. Based on the simulation results produced $30,000m^3/h$ grade waste heat recovery, heat exchanger was performed for the actual experiment. In addition, performance tests exceed the capacity of a large waste heat recovery heat exchanger performance test methods proposed.

공동주택내 다분기챔버형 환기시스템 적용을 통한 풍량분배 개선효과에 관한 연구 (Performance Evaluation of Multidrop Chamber Ventilation System in Apartment)

  • 김성수;손장열
    • 설비공학논문집
    • /
    • 제21권10호
    • /
    • pp.545-552
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. And TAB process is applied to control the designed air volume with adjusting volume dampers and/or supply diffusers after fully installing the ventilation system. This process has been resulted increasing the initial cost for the residential ventilation system because of man-hour and accessories such as volume control damper or diffuser. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system.