• 제목/요약/키워드: Air change rates

검색결과 159건 처리시간 0.042초

Air Change Rate Measurement Methods and Database

  • Lee, Kiyoung;Yukio Yanagisawa
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제11권E호
    • /
    • pp.1-12
    • /
    • 1995
  • In recent years the demand for energy conservation has resulted in "tight" buildings with decreased air change rates. Although a reduction in air change rates can save energy utilized for heating or cooling of dwellings, there is an increased concern for the air quality of the indoor environment where individuals spend most of their lifetime (Schwab et al., 1990).., 1990).

  • PDF

냉동냉장창고 침기방지장치의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Infiltration Prevent Devices in refrigerated Warehouse)

  • 곽현철;석호태;송승영;황혜주;안홍섭
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.55-62
    • /
    • 2002
  • In this paper, several types of infiltration prevention devices that are currently in use have been studied through experimental investigation. Firstly, the types of infiltration prevention devices were defined through investigating actual conditions of refrigerated warehouse in operates. Based on this investigation results, measured change of temperature and figured out air change rates of the type of infiltration prevention devices by using scale down model. After that, found the amount of air change rate in order to estimate the load of air change easily in facility plan.

유지제 혼입율 변화에 따른 콘크리트의 유동성 및 역학적 특성 (Liquidity and Mechanical Properties of Concrete by Fluidity Retention Agent Mix Rate Change)

  • 박병관;최성용;배장춘;노동현;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.89-92
    • /
    • 2008
  • This research analyzed the basic characteristics of unhardened concrete and the compression strength characteristics of hardened concrete according to liquidity retention agent mix rate change to improve the liquidity fluidity retention performance of high performance concrete, and produced the following results. The moment fluidity retention agent is added according to fluidity retention agent mix rate change, which increased fluidity retention agent mix rate, slump flow decreased, and in the case of slump flow according to the progress time change by the fluidity retention agent mix rates, the more fluidity retention agent mix rate increased, the lower slump flow change rate became. The moment fluidity retention agent is added according to fluidity retention agent mix rate change, fluidity retention agent mix rate increased compared to non-mixture of fluidity retention agent, and the air amount by progress time change by the fluidity retention agent mix rates slightly increased, however target range is still met and unit volume mass is inversely proportional to air amount. Compression strength according to age progress by the fluidity retention agent mix rates was shown to increase slightly with increase in fluidity retention agent mix rate, and yet the difference was not significant.

  • PDF

동시냉난방 시스템 에어컨의 냉매량 변화에 따른 고낙차 장배관 운전 신뢰성 평가 (Evaluation of the operating reliability on the concurrent heating-cooling system air conditioner for different refrigerant flow rates with high-head and long-line conditions)

  • 이승찬;김태안;태상진;정규하;문제명;김윤제
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.304-309
    • /
    • 2008
  • The heating and cooling performances of system multi-air conditioner for various refrigerant flow rates with high-head and long-line conditions are experimentally investigated. The maximum head and tube length were 110 m and 1000 m, and the two different adjustments of refrigerant flow rates were +20 % and -20 %, respectively. The experimental system was composed of 4 outdoor units with module systems, and 13 indoor units which were joined with the mode change unit by single-tube circuit. Field tests without indoor and outdoor temperature control were performed in a general office building with two different refrigerant flow rates. Especially, the oil level in the compressor was normally maintained at the safety zone. Experimental results were prepared on the p-h diagram.

  • PDF

실간환기량 측정을 위한 멀티추적가스법의 검증실험 (An Experiment on Verification of Multi-Gas Tracer Technique for Air Exchange Rate Between Rooms)

  • 한화택;조석효
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.99-104
    • /
    • 2007
  • Tracer gas technique is widely used to measure the ventilation rates and/or ventilation effectiveness of building spaces. However, the conventional method using a single tracer gas can measure only outdoor air change rates in a single zone. This paper deals with the multi-gas tracer technique to measure air exchange rates between rooms. Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Experiments are conducted in a simple two-room model with known airflow rates using tracer gases of SF6 and R134a. The concentration decays of two tracer gases are measured after simultaneous injections in each room. The governing equations are derived from the continuity and the mass balance of each room. The data reduction procedure are developed to obtain the inter-room airflow rates using the governing matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, smoothing, and etc, to improve the estimate and interpretation of the results.

  • PDF

공기보조식 (air-assisted) 플래쉬 분무의 분무 각 확대 특성 연구 (Analysis of spray cone angle of air assisted flash atomization)

  • 류태우;김세원;방병열
    • 한국분무공학회지
    • /
    • 제10권1호
    • /
    • pp.1-9
    • /
    • 2005
  • When the water jets heated up to the saturation temperature at a high line pressure are sprayed into a reduced (atmospheric) pressure through an air-assisted nozzle, the jets experience sudden exposure into a reduced pressure, get superheated and produce steam bubbles while atomization processes of jets are taking place. This process is called flash atomization. In this study the flash atomization of superheated water jets assisted by air has been studied. Sprays with flash atomization have been photographed at various water and air flow rates and water superheats. It has been found that the spray angle with flash atomization increases with water superheat and water flow rate but decreases with air flow rate. The degree of change of spray angle has been analyzed and correlated as a function of superheat, air and water flow rates.

  • PDF

상변화 축열계의 비정상 해석 (A Study on Two Dimensional Phase Change Problem)

  • 원성필;노승탁
    • 대한설비공학회지:설비저널
    • /
    • 제10권1호
    • /
    • pp.12-21
    • /
    • 1981
  • The Enthalpy Model was verified in order to analyze two- dimensional phase change problems. By using the Enthalpy Model, interface locations, frozen fraction rates, heat flux distribution rut cooled surfaces, and surface-integrated heat flux were purely numerically calculated in rectangular thermal storage units, whose initial condition was saturated liquid and phase change material was cooled on its boundaries by convective heat transfer. The calculations were performed for various Stefan numbers and Biot numbers. The effect on those dimensionless numbers were explained.

  • PDF

환기회수 및 부하율 변화에 따른 휘발성유기화합물 농도 감쇠 예측에 관한 연구 (Prediction of the Concentration Decay of Volatile Organic Compounds under Different Air Change Rates and Loading Factor Conditions)

  • 방승기;손장열;안병욱
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.505-513
    • /
    • 2005
  • We measured the time-dependent concentration of VOCs emitted from Ondol floor, furniture, and the wall made of various building materials. After obtaining results from the previous measurement, we developed the estimation equations of the concentration decay, and obtained the estimated graphs for the concentration decay under different air change rates and loading factor conditions by using the estimated equations. We conducted our tests by applying our measurements to real residences for 110 days in the case of furniture and for 40 days in the case of the floor. We also conducted experiments in the cases of various wall materials for 7 days which totaled 10 times. We used the GC/FID for experiments for real residences accord-ing to the specified procedures of the NIOSH 1501, and carried out experiments for wall materials according to the specified procedures of the ASTM 5116-97. When conducting experiments for wall materials, we set the temperature and relative humidity at $23^{\circ}C$ and $50\%$, respectively. We also set the air change rate and loading factor at 0.7/h and $1.617 m^2/m^3$, respectively. Our results showed that it is possible to predict proplrly the time-dependent concentration decay of VOCs by using logarithmic functions in both cases of experiments for real residences and for wall materials. Furthermore, we found that the concentration decay rate of VOCs increased rapidly as the air exchange rate increased while the concentration decay rate decreased as the loading factor increased.

Y-Jet 노즐에서의 혼합관 길이변화에 따른 분무특성 연구 (Change of Spray Characteristics with Mixing Port Length of Y-Jet Atomizers)

  • 송시홍;이상용
    • 대한기계학회논문집
    • /
    • 제18권11호
    • /
    • pp.3021-3031
    • /
    • 1994
  • Experiments have been performed to find out the effect of the mixing port length of Y-jet atomizers on the spray performance, using air and water as the test fluids. Water and air flow rates and drop sizes were measured at each injection pressure condition for different mixing port length. The air flow rate was almost unaffected by the change of the mixing port length. However, the water flow rate was relatively susceptible to the change of the mixing port length. The mixing point pressure was very much influenced by the mixing port length. Variations of spatial distribution of Sauter Mean Diameter (SMD, $D_{32}$) and the cross-section-averaged SMD ($D_{32,m}$) with different mixing port length and air/water mass flow rate ratio were examined. Generally, when the mixing port length was reduced, the mean drop size decreased and became spatially even.