• Title/Summary/Keyword: Air cap

Search Result 102, Processing Time 0.026 seconds

An Experimental Study on Transition and Film Boiling Heat Transfer of Impinging Water Jet (충돌수분류의 천이 및 막비등열전달에 관한 연구)

  • Ohm, Ki-Chan;Seo, Jeong-Yun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.2
    • /
    • pp.87-97
    • /
    • 1985
  • Experimental measurements of the heat flux to a upward impinging water jet on high heated test surface were obtained in the transition and film boiling regimes. Test variables were nozzle outlet velocity, subcooled water temperature and height of supplementary water. Boiling curve of this investigation is similar to a pool boiling curve, but it has one or two cap-shaped peaks in the transition regime. In the film boiling regime, the heat transfer rates are increased along with the increment of nozzle outlet velocity and subcooled temperature. There is optimum height of supplementary water for the augmentation of heat transfer Generalized correlations of boiling heat transfer are presented for maximum heat flux, minimum heat flux and $q_c$ at each supplementary height.

  • PDF

Application of High Resolution Land Use Data on the Possibility to Mitigate Urban Thermal Environment (고해상도 지표자료를 이용한 도시 열환경 완화효과 가능성에 관한 연구)

  • Lee, Kwi-Ok;Lee, Hyun-Ju;Lee, Hwa-Woon
    • Journal of Environmental Science International
    • /
    • v.18 no.4
    • /
    • pp.423-434
    • /
    • 2009
  • In recent years, the urban thermal environment has become worse, such as days on which the temperature goes above $30^{\circ}C$, sultry nights and heat stroke increase, due to the changes in terrestrial cover such as concrete and asphalt and increased anthropogenic heat emission accompanied by artificial structure. The land use type is an important determinant to near-surface air temperature. Due to these reasons we need to understand and improve the urban thermal environment. In this study, the fifth-generation Pennsylvania State University-National Center for Atmospheric Research Mesoscale Model(MMS) was applied to the metropolitan of Daegu area in order to investigate the influence of land cover changes and urban modifications increase of Albedo to the surface energy budget on the simulated near-surface air temperature and wind speed. The single urban category in existing 24-category U.S. Geological survey land cover classification used in MM5 was divided into 6 classes to account for heterogeneity of urban land cover. As a result of the numerical simulation intended for the metropolitan of Daegu assumed the increase of Albedo of roofs, buildings, or roads, the increase of Albedo (Cool scenario)can make decrease radiation effect of surface, so that it caused drops in ambient air temperature from 0.2 to 0.3 on the average during the daylight hours and smaller (or near-zero) decrease during the night. The Sensible heat flux and Wind velocity is decreased. Modeling studies suggest that increased surface albedo in urban area can reduce surface and air temperatures near the ground and affect related meteorological parameters such as winds, surface air temperature and sensible heat flux.

A Study of Carbonaceous Aerosols Measurement in Metropolitan Area Performed during KORUS-AQ 2016 Campaign (수도권 지역의 탄소 성분 에어로졸 측정 연구: KORUS-AQ 2016 캠페인 기간을 중심으로)

  • Jeong, Byeongju;Bae, Min-Suk;Ahn, Junyeong;Lee, Jeonghoon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.3
    • /
    • pp.205-216
    • /
    • 2017
  • Carbonaceous aerosols such as the equivalent black carbon (eBC), the elemental carbon (EC) and the organic carbon (OC) were monitored at the Seoul Olympic Park site ($37.521^{\circ}N$, $127.124^{\circ}E$) during the KORUS-AQ 2016 campaign using a Multi Angle Absorption Photometer (MAAP) and an OCEC Analyzer. Averaged mass concentrations of eBC, EC and OC were presented as $2.46{\pm}1.52{\mu}g/m^3$, $1.01{\pm}0.60{\mu}g/m^3$ and $4.85{\pm}2.60{\mu}g/m^3$, respectively. OC/EC ratio and mass absorption cross-section (MAC) of light absorbing aerosols were calculated as 2.32 and $14.8m^2/g$, respectively. Diesel OC concentrations were estimated from a source profile of diesel vehicles as well. eBC mass concentrations measured from May $26^{th}$ to May $27^{th}$, 2016 showed 40% higher than averaged eBC mass concentrations during campaign period. $PM_{2.5}$ concentrations measured in this period were also higher than average $PM_{2.5}$ concentrations. High eBC concentrations were observed from May $29^{th}$ to May $31^{st}$, 2016 and from June $9^{th}$ to June $11^{th}$, 2016, possibly due to morning rush hour and the effect of temperature inversion at night. Diurnal variations of eBC, EC and Diesel OC showed a typical pattern of metropolitan area. In the weekend, however, diurnal variations of eBC, EC and Diesel OC mass concentrations were different from those measured in the weekday. It is expected that this study can help to understand the relationship between carbonaceous aerosols in a metropolitan area.

Laboratory investigation of unconfined compression behavior of ice and frozen soil mixtures

  • Jin, Hyunwoo;Lee, Jangguen;Zhuang, Li;Ryu, Byung Hyun
    • Geomechanics and Engineering
    • /
    • v.22 no.3
    • /
    • pp.219-226
    • /
    • 2020
  • Unconfined compression test (UCT) is widely conducted in laboratories to evaluate the mechanical behavior of frozen soils. However, its results are sensitive to the initial conditions of sample creation by freezing as well as the end-surface conditions during loading of the specimen into the apparatus for testing. This work compared ice samples prepared by three-dimensional and one-dimensional freezing. The latter created more-homogenous ice samples containing fewer entrapped air bubbles or air nuclei, leading to relatively stable UCT results. Three end-surface conditions were compared for UCT on ice specimens made by one-dimensional freezing. Steel disc cap with embedded rubber was found most appropriate for UCT. Three frozen materials (ice, frozen sand, and frozen silt) showed different failure patterns, which were classified as brittle failure and ductile failure. Ice and frozen sand showed strain-softening, while frozen silt showed strain-hardening. Subsequent investigation considered the influence of fines content on the unconfined compression behavior of frozen soil mixtures with fines contents of 0-100%. The mixtures showed a brittle-to-ductile transition of failure patterns at 10%-20% fines content.

Heat transfer enhancement of finless TEFC induction motor frame by installing guide vanes (핀이 없는 전폐형 유도전동기 프레임의 정익 설치에 의한 열전달 향상)

  • Jeon, Chang-Seong;Go, Sang-Geun;Yun, Myeong-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.849-859
    • /
    • 1998
  • The heat generated in an induction motor is mostly dissipated through the frame. The study on the heat transfer characteristics of a newly manufactured finless TEFC(Totally Enclosed Fan Cooled) induction motor showed/that it had an unsuitable structure in view of the heat transfer. The angle of the cooling air flow was very large and the ribs disturbed the air flow and partially generated the wake region on the frame. In the wake region the temperature was very high. Thus the heat transfer coefficients were lower than those of the frame with fins. Also was investigated the heat transfer characteristics of the motor frame by installing various guide vanes in the fan-side end cap. An optimum heat transfer case was found and the average heat transfer coefficient of the frame was 70% higher and the average coil temperature measured by the resistance method was 9 deg. C lower than that of the frame which had no guide vanes.

Temperature History of the Concrete Corresponding to Various Curing Sheets in the Low Temperature (저온환경에서의 양생시트 변화에 따른 콘크리트의 온도이력 특성)

  • Baek, Dae-Hyun;Hong, Seak-Min;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.781-784
    • /
    • 2008
  • In this paper, insulating effect and strength development of concrete under low temperature are reported varying curing sheets. According to test results, in temperature -5$^{\circ}$C concrete subject to exposure and air cap condition, result in a frost damage at early age by a fall of below zero temperature. Mean while, the combination of PE film and non-woven fabric maintained around 3 $^{\circ}$C within first 24 hours since placement. For double bubble sheets, concrete temperature maintained above 7$^{\circ}$C due to its excellent heat insulating capability. As a result of core strength test, strength of specimens cured with viny + non-woven fabric and double bubble sheets had higher strength than strength of other specimens due to good heat insulation effect at early age.

  • PDF

Optical Cap Sensor for Magneto-Optic Near-Field Recording (MO 근접장 기록을 위한 광학 갭 센서)

  • Yoon, Yong-Joong;Park, Jae-Hyuk;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.3
    • /
    • pp.245-250
    • /
    • 2004
  • This paper proposes a new method of measuring an air interface distance between a solid immersion lens(SIL) applied magneto-optic technology and the disk surface. For applying near-field recording (NFR) technology to the magneto-optic storage devices for the next generation, it is positively necessary to maintain the small air gap under about 100㎚. We design an apparatus that consists of some optical components such as a prism, a polarizer and an analyzer. By using the Fresnel reflection coefficient equation, Jones matrices calculation and Malus's law, we establish a mathematical model for understanding the characteristics of the system. The simulations are based on the mathematical model and through the simulation results which is made with various cases we can estimate the performance of the new optical gap sensor system. Experimental results, which are also based on the mathematical model for specific cases, are in good agreement with simulated ones and demonstrate the possibility as the new optical gap sensor.

Evaluation of Inner Flow Characteristics of Oxygen Sensor for Vehicle Exhaust System (자동차 배기계용 산소센서 내부유동 특성 평가)

  • Han, Dae-Kwang;Suh, Ho-Cheol;Yee, Jurng-Jae;Kang, Jung-Ho;Han, Seung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.2
    • /
    • pp.47-54
    • /
    • 2012
  • An oxygen sensor installed in vehicle exhaust systems enables to measure the amount of oxygen in the exhaust gas, in which the measured data are collected and analyzed in ECU(Engine Control Unit). The oxygen sensor is exposed to the high speed exhaust gas at high temperature circumstance, so that protection caps are required not only to protect the susceptible measuring part, but also to provide the real time measurement without time delay. In this study, a new oxygen sensor with one protection cap was proposed, and the CFD analysis was carried out in order to compare the performance characteristics, such as flow speed and ratio of AOA(Age of Air), for the conventional and new oxygen sensor. The numerical results of CFD analysis provided the flow speed of 1.34m/s and the ratio of AOA of 3.43. The similar features obtained from the numerical results showed that the new oxygen sensor guarantees the same performance characteristics of the conventional ones.

Comparative Study on the Protective Functions of Clothes (의복의 보호론에 관한 이론적 고찰)

  • Lim Sook Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.9 no.3
    • /
    • pp.71-78
    • /
    • 1985
  • This research is designed to systemize the protection theory as well as to supplement the missing theory by organizing various studies on the protective functions of celothes by domestic and foreign scholers of clothing. Human environments is classified two standpoints : (1) Physical environments, and (2) man built psychological environments including socio-physical environments, socio-biological environments, behavioral environments, socio-psychological environments and institution environments. Clothes acting as a physical protection might be of (1) extreme air temperature: Parka; (2) high relative humidity: raincoat; (3) air movement: windbreaker; (4) radiation: space suit; (5) atmospheric pressure: deep sea diver suit; (6) mechanical agent: bullet proof vest; (7) physical agent: (8) chemical agent: (9) biological agent: surgeon's gown, cap, and mask. Also dresses act to support the body comfort, health and the well-being; corset for bad back patient, wrist band for people with weak wrist, bottom half of pressure suit for people with low blood pressure. Clothes acting as a psychological protection might be of (1) influence of magic and of spirits: (2) moral danger; (3) the general unfriendliness of the world as a whole; a reassurance against the lack of love. Clothes should provide the maximum of satisfaction in accordance with the full recognition of reality. The reality should aim at the formulation of general laws concerning the most pleasing forms, colors, and styles to suit. The complex physiological anatomical and psychological aspects of individual personalities.

  • PDF

A Comparison Study on Isoprene Emission Rates from White Oak (갈참나무로부터 발생되는 이소프렌의 배출속도 비교 연구)

  • Son, Youn-Suk;Kim, Jo-Chun;Kim, Ki-Joon;Lim, Yong-Jae;SunWoo, Young;Hong, Ji-Hyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.791-798
    • /
    • 2006
  • In order to investigate the NVOC (Natural Volatile Organic Compound) emissions from White Oak, the emission rates of isoprene were measured according to season, weather conditions, and the age of the tree. The analysis of seasonal emission rates showed that the emission rates were the highest during summer followed by spring and fall. The emission rates during summer were found to be nearly 8 times greater than those during fall. In addition, it was observed that the emission rates of isoprene depends on PAR and temperature. Moreover, the effect of age on the emission rates was studied, and the White Oak in the age range of $21{\sim}30$ had higher emission rates than that in the range of $41{\sim}50$. Accordingly, the current result indicates that the isoprene emissions are affected by both meteorological parameter and the age of a tree.