• Title/Summary/Keyword: Air and water environment

Search Result 1,164, Processing Time 0.035 seconds

Estimation of Indoor Environment using CFD of Multi-Purpose System with a Solar Collector -Part 1, focused on floor area and number of ventilation- (태양열온수기 적용 냉난방시스템의 CFD를 이용한 실내환경 평가 -제1보 바닥면적과 환기횟수를 중심으로-)

  • Kim, Jong-Ryeol;Choi, Kyang-Hyan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.55-61
    • /
    • 2007
  • This paper has been conducted to estimate cooling capacity of the dehumidification tower using hot water from a solar water heating system as a energy source of regeneration process when the dehumidification and drying system is applied to room cooling. A solar water heating system was operated and indoor temperature distributions were simulated according to weather conditions when the concerned solution was used to dehumidify room air in the dehumidification tower. Through this simulation researches we found th following results ; It was found that air velocity through supply and return diffusers should be controlled because it can cause uncomfort in dwelling area. It was found that in the sunny morning temperatures of dwelling area 1 and 2 are higher than those of dwelling area 3 and 4. In this research all the calculation results of heating and cooling system supported by solar water heater have confirmed that its cooling capacity could not reach PMV 0, thermal comfort.

Derived Limits for Radiological Protection Against ionizing Radiation Based on ICRP-60 Recommendations

  • Jang, Si-Young;Lee, Byung-Soo
    • Nuclear Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.350-360
    • /
    • 2000
  • In Korea, the dose limits are reduced and are set at the ICRP-60 iimits. However, derived limits tabulated as MPC in air and water are still specified in Notice No.98-12. There are some discrepancies between the primary dose limits and MPCs in air and water. Therefore, in order to accept ICRP-60 recommendations fully, derived limits such as ALI, DAC, ECL for radiological protection against ionizing radiation based on ICRP-60 recommendations were calculated using modified methods of those of 10 CFR part 20, dose limits and committed effective dose coefficients of the Basic Safety Standards of the IAEA. The derived limits in this study were also compared with those prescribed in 10 CFR part 20 as well as MPCs of Notice No. 98-12 in order to analyze the impact of implementing derived limits on nuclear facilities. ECLs in air and water for the control of radioactive discharge into the environment in this study are shown to have lower values (i.e. more conservative), for most part, than those in Notice No. 98-12. Especially, for uranium elements, ECLs in water are approximately a magnitude in the order of two lower than those in Notice No.98-12.

  • PDF

Analysis of Treatment Efficiency of Cylinder-Shaped Filter for Construction Site Runoff Control (건설현장 탁수제어를 위한 원통형 여과장치의 처리효율 분석)

  • Choi, Jongsoo;Kong, Young-San;Lee, Jung-Min;Bang, Ki-Woong
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.532-538
    • /
    • 2014
  • A cylinder-shaped filter was developed to manage the runoff from construction sites. Compressed air was used for back-washing and pore sizes of filter were $23{\mu}m$ and $46{\mu}m$. The turbid water was prepared using sediments in construction sites. The grain size analysis showed that grains smaller than $38{\mu}m$ and larger than $335{\mu}m$ in size constituted 34.4 % and 37.6 %, respectively. Removal efficiency of the filter on turbidity, SS, COD, TN and TP showed 25~37%, 20~40%, 50~55%, 23~27% and 14~20%, respectively, whereas their removal efficiecy by using coagulant PAC showed 77~84%, 70~83%, 53~60%, 27~36%, and 59~75%, respectively. The filtration time was determined to be around 10 to 20 minutes. Back-washing for 10 seconds by pressurized air resulted in a satisfactory regeneration efficiency. According to the aforementioned test results, the cylinder-shaped filter is effective in reducing turbidity and would be suitable for practical application in construction sites and farms.

Friable Test and Risk Assessment for Asbestos in Soils using the Releasable Asbestos Sampler (RAS) (석면 비산 장비를 이용한 토양 중 석면 비산 특성 및 위해성 평가)

  • Kim, In Ja;Kim, Jeong-Wook;Ryu, Hyun Sik;Jung, Myung Chae
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.5
    • /
    • pp.68-74
    • /
    • 2012
  • The objective of this study is to examine a releasable asbestos sampler developed for measuring friable asbestos from soil to air controlled by wind velocity and water contents. Asbestos contaminated soil with 3.75% at the Sinsuk-asbestos mine was sampled, air-dried and sieved to 100 mesh, then homogenized during 24 hours' agitation. Various wind velocities, 1 m/s, 2 m/s, 3 m/s, and 5 m/s, were applied to evaluate releasable characteristics of the releasable asbestos sampler. In addition, soils with 1.0%, 3.4%, 4.4%, 11.0%, 16.2%, and 20.0% of water contents were also examined the amount of friable asbestos by the releasable asbestos sampler. Collected soil and air samples were analyzed by polarized light microscopy (PLM) and phase contrast microscopy (PCM), respectively. Those contents were applied to calculate an excess life cancer risk (ELCR). This study also discussed the relationship with risk assessment by a weeding scenario of activity based sampling (ABS) and field applied releasable asbestos sampler. The result was shown that friability of asbestos in soil increased with wind velocity and decreased with water content. In comparison with ELCR results, over 10E-4 of cancer risk was found in condition on < 5% water content and > 3m/s wind velocity.

Comparative Study on Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air-Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 비교연구)

  • Kim, Hyung-Tae;Song, Gen-Soo;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun;Kwon, Oh-Myung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1249-1255
    • /
    • 2011
  • In modern large-scale semiconductor manufacturing clean rooms, the energy consumed by the outdoor air-conditioning system during heating, humidification, cooling, and dehumidification of the incoming outdoor air represents about 45% of the total air-conditioning load required to maintain a clean-room environment. In particular, the energy required for humidification of the outdoor air in winter is very high. Therefore, evaluation and comparison of the energy consumption in key humidification systems, viz., steam-humidification and water-spray-humidification systems, used in outdoor air-conditioning systems would be useful to reduce the outdoor air-conditioning load in clean rooms. In the present study, an experiment with an outdoor air flow of 1000 $m^3$/h was conducted to compare the air-conditioning process and energy consumption in outdoor air-conditioning systems with electrodeboiler steam humidifiers and air-washer water spray humidification systems. The experimental results showed that the water-spray-humidification-type outdoor air-conditioning system consumed less electrical power than did the steam-humidification-type system and was more energy efficient during winter.

Characteristics of PM2.5 Carbonaceous Aerosol using PILS-TOC and GC/MS-TD in Seoul (PILS-TOC 및 GC/MS-TD를 이용한 서울시 대기 중 초미세먼지(PM2.5) 유기탄소의 특성 분석)

  • Park, Da-Jeong;Ahn, Joon-Young;Shin, Hye-Jung;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.5
    • /
    • pp.461-476
    • /
    • 2014
  • Continuous Water-Soluble Organic Carbons (WSOC) by the Particle Into Liquid Sampler - Total Organic Carbon (PILS-TOC) analyzer were measured at the Seoul intensive monitoring site from June 17 through July 5 in 2014. In addition, the 24 hour integrated PM2.5 collected by Teflon and Quartz filters were analyzed for water soluble ions by Ion chromatography (IC), WSOC by TOC from water extracts, organic carbon (OC), elemental carbon (EC) by carbon analyzer using the thermal optical transmittance (TOT) method, and mass fragment ions (m/z) related to alkanes and PAHs (Poly Aromatic Hydrocarbons) by Gas Chromatography-Mass Spectrometer-Thermal Desorption (GC/MS-TD). Based on the statistical analysis, four different Carbonaceous Thermal Distributions (CTDs) from OCEC thermal-gram were identified. This study discusses the primary and secondary sources of WSOC based on the Classified CTD, organic mass fragments, and diurnal patterns of WSOC. The results provide knowledge regarding the origins of WSOC and their behaviors.

The Analysis of heating performance of heat pump system for agricultural facility using underground air in Jeju area - Focused on the Jeju Area - (제주지역 지하공기를 이용한 농업시설용 히트펌프시스템의 난방 성능 분석 - 제주지역을 중심으로 -)

  • Kang, Youn-Ku;Lim, Tae-Sub
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.109-114
    • /
    • 2016
  • Purpose: The underground air is the warm air discharged from the porous volcano bedrock 30-50m underground in Jeju, including excessive humidity. The temperature of the underground air is $15-20^{\circ}C$ throughout the year. In Jeju, the underground air was used for heating greenhouses by supplying into greenhouses directly. This heating method by supplying the underground air into greenhouses directly had several problems. The study was conducted to develop the heat pump system using underground air as heat source for resolving excessive humidity problem of the underground air, adopting the underground air as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) and saving heating cost for agricultural facilities. Method: 35kW scale(10 RT) heat pump system using underground air installed in a greenhouse of area $330m^2$ in Jeju-Special Self-Governing Province Agricultural Research & Extension Services, Seogwipo-si, Jeju. The inlet and outlet water temperature of the condenser, the evaporator and the thermal storage tank and the underground air temperature and the air temperature in the greenhouse were measured by T type thermocouples. The data were collected and saved in a data logger(MV200, Yokogawa, Japan). Flow rates of water flowing in the condenser, the evaporator and the thermal storage tank were measured by an ultrasonic flow meter(PT868, Panametrics, Norway). The total electric power that consumed by the system was measured by a wattmeter(CW240, Yokogawa, Japan). Heating COP, rejection heat of condenser, extraction heat of evaporator and heating cost were analyzed. Result: The underground air in Jeju was adopted as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) in 2010. From 2011, the heat pump systems using underground air as a heat source were installed in 12 farms(16.3ha) in Jeju.

Improvement of Uncertainty for Gravimetric Flow Calibrator (10톤 용량의 중량식 교정장치에 대한 불확도 개선)

  • Lee, Dong-Keun;Park, Joo-Young;Lee, Haeng-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1042-1046
    • /
    • 2008
  • Both the weighing bridge and the diverter system is a important component in achieving a high accuracy liquid flow rate standard using a static gravimetric method. The weighing bridge is a tank which weighing collected flow with a load cells. The diverter is a moving device used to direct flow alternately along its normal course(by pass) or towards the weighing tank. The time needed for collection into the weighing tank is measured using a timer. So it is important to the diversion period is sufficiently fast and triggering point of timer which is determined the filling time. On this studies show that the measurement deviation of load cell and uncertainty of diverter system for changing diversion speed and triggering point was estimated in accordance with Guide to The Expression of Uncertainty in Measurement(ISO).

  • PDF

The energy-saving effect by controlling the number of operating chillers in university facility (대학시설에 대한 열원기기 대수 운전 제어의 에너지 절약 효과)

  • Lee, Je-Hyeon;Akashi, Yasunori;Kum, Jong-Soo;Kim, Dong-Gyu
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1043-1048
    • /
    • 2009
  • This paper proposes the new operation control method that let heat source system stop and circulate only hot water at low load, and verified the introduction effect. At first, we constructed simulation model of heat source system and examined the proposing method by using simulation model. At last, we examined the introduction effect of proposing method with actual building. As a result, the primary energy consumption of heat source system was reduced by about 13%.

  • PDF

Assessment of Evaporation Rates from Litter of Duck House (오리사 바닥재의 수분 증발량 평가)

  • Lee, Sang-Yeon;Lee, In-Bok;Kim, Rack-Woo;Yeo, Uk-Hyeon;Decano, Cristina;Kim, Jun-gyu;Choi, Young-Bae;Park, You-Me;Jeong, Hyo-Hyeog
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.5
    • /
    • pp.101-108
    • /
    • 2019
  • The domestic duck industry is the sixth-largest among the livestock industries. However, 34.3% of duck houses were the duck houses arbitrarily converted from plastic greenhouses. This type of duck house was difficult to properly manage internal air temperature and humidity environment. Humidity environment inside duck houses is an important factor that directly affects the productivity and disease occurrence of the duck. Although the humidity environments of litters (bedding materials) affect directly the inside environment of duck houses, there are only few studies related to humidity environment of litters. In this study, evaporation rates from litters were evaluated according to air temperature, relative humidity, water contents of litters, and wind speed. The experimental chamber was made to measure evaporation rates from litters. Temperature and humidity controlled chamber was utilized during the conduct of the laboratory experiments. Using the measured data, a multi linear regression analysis was carried out to derive the calculation formula of evaporation rates from litters. In order to improve the accuracy of the multi linear regression model, the partial vapor pressure directly related to evaporation was also considered. Variance inflation factors of air temperature, relative humidity, partial vapor pressure, water contents of litters, and wind speed were calculated to identify multicollinearity problem. The Multiple $R^2$ and adjusted-$R^2$ of regression model were calculated at 0.76 and 0.71, respectively. Therefore, the regression models were developed in this study can be used to estimate evaporation rates from the litter of duck houses.